Records from 2006 to 2026. Most recent: inspection, 24 July 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
24 July 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8445406
12 May 2026
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8358767
14 April 2026
Administrative Inspection · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8349624
14 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7865734
7 June 2021
Examination of Repairs · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7202053
19 August 2019
SIP Initial Entry · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6788755
19 June 2018
MTSA Verification · Construction Oversight · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6449334
4 May 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6136521
10 May 2016
Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5870715
6 August 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5204755
18 September 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4986710
16 September 2014
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4985005
16 September 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4997395
3 September 2014
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4972271
5 June 2014
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4870332
15 January 2014
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4783372
14 November 2013
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4752774
21 July 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4670674
13 December 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4502186
13 September 2012
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4443731
16 July 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4377708
14 February 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4251874
22 August 2011
COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4123951
28 May 2010
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3750135
12 June 2009
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3501974
18 July 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3271654
28 September 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062762
31 July 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3014479
22 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2859949
22 January 2007
MTSA Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2860056
24 October 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2807117
10 October 2006
Initial Construction-Excluding Oversight · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2797721
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2026
Resolved
The current standards established by the American Bureau of Shipping in effect at the time of construction of the vessel shall be used. Vessel reported allision with anchor buoy of a foreign chemical tank vessel while mooring. Buoy hit the midship of the barge on the starboard side. Survey report to assess damage and testify to condition of vessel prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 24 July 2026
Resolved 24 July 2026
Resolution: TPO report attested to satisfactory condition of vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2024
Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. Barge sustained hull damage during allision with another barge. Vessel restricted from movement pending TPO survey.
Condition: Damaged By Earlier Event
Due 14 February 2024
Resolved 14 February 2024
Resolution: Received TPO report; all sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 September 2014
Resolved
As per 46 CFR 31.05-5, Progressive Barge Lines(owner) failed to maintain the Certificate of Inspection(COI) aboard vessel. The original COI must remain aboard vessel at all times for the vessel to be considered certified for the carriage of dangerous cargoes.
Action required: 705 - Other - as specified
Due 18 September 2014
Resolved 17 September 2014
Resolution: Owner located and returned the original COI to the vessel. COI is now onboard and verified by attending marine inspector.
Construction/Loadline › Structures › Trunk
Issued 16 September 2014
Resolved
As per 46 CFR 2.90-1, Progressive Barge Lines(owner) is to submit Commandant approved plans for the installation of tankerman shelters located on top of tank trunks. Failure to provide proof of approved plans requires immediate removal of shelters and verification to Coast Guard Marine Inspector that shelters are removed.
Action required: 705 - Other - as specified
Due 16 October 2014
Resolved 17 September 2014
Resolution: Owner submitted approved construction drawings and approval letter from MSC allowing tankerman shelter.
Deck/Cargo › Cargo Heating › General
Issued 5 June 2014
Resolved
Cannot use Thermal Fluid Heater until a test of the system has been conducted by an CG Marine Inspector. The TFH shall remain tagged out until Marine Inspector approval.
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 3 September 2014
Resolution: Successfully witnessed test of all alarm and safety limits on thermal fluid heater. Tests were conducted by a Volcanic representative.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 10 October 2006
Resolved
SOPEP approval letter prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2006
Resolved 22 January 2007