Records from 2006 to 2022. Most recent: inspection, 28 November 2022.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
28 November 2022
MTSA Verification · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7595772
22 February 2022
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396267
30 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7345593
6 August 2020
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7025781
10 October 2019
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6831704
29 April 2019
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6672715
27 November 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6587768
15 September 2017
COI Inspection · Examination of Repairs · Drydock Exam · Cargo Tank Internal · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6265826
27 June 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5945899
3 March 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826267
4 January 2016
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5790690
18 December 2015
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5782332
2 December 2014
Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5032911
21 December 2013
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4772735
5 November 2013
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4747805
26 November 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4489285
2 November 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4181166
27 September 2011
MTSA Verification · COI Inspection · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4155558
17 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4085938
14 December 2010
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3909798
7 July 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3788544
30 January 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3673778
30 January 2010
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3674663
7 August 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3558235
29 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3549658
29 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3549809
15 December 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3376672
16 April 2008
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3185771
14 November 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3097756
23 May 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2938515
13 November 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2819784
26 September 2006
Cargo Tank Internal · Internal Structural Exam · Hull Examination · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2787364
22 August 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2756210
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 10 October 2019
Resolved
Vessel equipped with a vapor control system and high-level and overfill alarm meeting 46 CFR 39.2007 (as referenced by 46 CFR 39.2009(a)). Starboard #3 cargo tank alarm actuator incorrectly activated the overfill alarm prior to activating the high-level alarm. System required to properly actuate at #3 cargo tank.
Action required: 10 - Deficiency Rectified
Resolved 10 October 2019
Resolution: Prior to the end of the inspection the equipment was serviced and proper function was demonstrated.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 14 November 2007
Resolved
Provide satisfactory documentation or evidence that the vessel’s cargo pump engine meets the requirements of 46CFR111.105-31 for installation within a class 1, division 1 location or submit a satisfactory proposal for relocation of the engine outside of the hazardous location by 01Aug2008.
D8 Policy Ltr 02-2007 (CH-1) dtd 15Aug2007
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 11 October 2011
Resolution: Engine was modified to meet 46 CFR 111.105-31
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 September 2006
Resolved
Vessel owners are to prove that cargo pump engine unit is in complete compliance with 46 CFR 111.105-31(l).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 14 November 2007
Resolution: Issued 01 new (CG-835) requirement for the vessel''s cargo pump prime mover not being in compliance with 46CFR111.105 with a compliance date of 01Aug2008 IAW D8 Policy ltr 02-2007 (CH-1) dtd 15Aug2007.