Inspection history · 217
4 August 2026
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8455249
4 August 2026
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8464241
13 April 2026
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8347136
9 April 2026
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8345069
2 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8289291
2 January 2026
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8289355
10 October 2025
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8250485
15 January 2025
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8064440
30 December 2024
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8056972
7 November 2024
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8031915
3 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8029208
22 August 2024
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7986690
15 June 2024
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7935460
15 June 2024
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7943850
13 June 2024
Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7934404
20 May 2024
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7915544
17 January 2024
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7851101
3 January 2024
Internal Structural Exam · In-Service Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7845235
17 December 2023
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7840081
3 October 2023
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7850966
10 June 2023
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7712801
15 May 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7689466
1 April 2023
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7661512
2 March 2023
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7644444
14 February 2023
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7636475
24 January 2023
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7630419
6 July 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7498210
28 June 2022
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7492426
18 June 2022
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7483883
25 April 2022
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7437813
25 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439803
14 March 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7411389
4 March 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7405408
4 January 2022
In-Service Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7392048
16 December 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7376009
17 November 2021
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7353474
4 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7188874
12 April 2021
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7173954
17 March 2021
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7158085
27 January 2021
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7132773
13 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7057037
11 September 2020
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7056374
11 September 2020
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7057569
26 June 2020
Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6988050
24 June 2020
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6985819
25 May 2020
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6960527
11 December 2019
Drydock Extension · COI Inspection · DAPI Audit · Administrative Inspection · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6875643
15 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6790201
9 July 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6743392
14 May 2019
Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6684372
20 March 2019
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6646782
22 February 2019
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6630327
10 January 2018
Deficiency Check · In-Service Inspection · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6361443
19 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6291506
31 August 2017
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6256200
30 August 2017
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6255317
18 January 2017
Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6063800
14 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5940776
3 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5868259
14 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5854169
12 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5852666
7 January 2016
Examination of Repairs · In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5809667
8 October 2015
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5739525
9 September 2015
Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5719612
21 July 2015
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5191083
25 March 2015
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5090331
24 March 2015
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5089718
17 March 2015
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5085352
20 February 2015
Administrative Inspection · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5071865
17 February 2015
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5070876
6 January 2015
Drydock Exam · Examination of Repairs · In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5050028
29 December 2014
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5045680
19 November 2014
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5026774
19 November 2014
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5027481
16 September 2014
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4984699
7 July 2014
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4913731
21 June 2014
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4894725
20 June 2014
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4893932
19 June 2014
Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4893200
14 April 2014
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4836453
20 March 2014
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4819733
19 March 2014
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4819654
14 February 2014
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4799966
8 January 2014
Internal Structural Exam · Annual Inspection · Drydock Extension
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4779587
21 November 2013
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4756714
11 October 2013
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4734963
10 October 2013
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4732683
19 June 2013
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4624732
19 June 2013
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4633384
16 June 2013
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4622889
7 September 2012
Deficiency Check · Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4434836
26 July 2012
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4669577
24 July 2012
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4390920
24 July 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4391416
11 June 2012
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4340675
9 January 2012
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4239006
13 October 2011
Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4167925
8 October 2011
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4163936
17 September 2011
Damage Survey · Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4149094
20 July 2011
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4088236
29 December 2010
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3917519
26 December 2010
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3916376
26 December 2010
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3919642
25 December 2010
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3916403
19 December 2010
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3913485
16 February 2010
Examination of Repairs
Physical examination · Commandant (CG-5P-TI) · Activity 3684933
4 February 2010
Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3675417
27 April 2009
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3469328
27 April 2009
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3474153
14 April 2009
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3452535
17 December 2008
Annual Inspection · Internal Structural Exam · Special · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3394873
6 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3339518
29 January 2008
Annual Inspection · Drydock Extension
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3138875
22 June 2007
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2973164
12 March 2007
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2891496
19 December 2006
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2992347
16 March 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2569484
8 April 2005
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3095352
15 March 2005
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2278545
29 September 2004
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2209351
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977872
3 December 2003
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1958417
21 July 2003
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1860334
13 January 2003
Annual Inspection · Drydock Extension
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1729466
29 March 2002
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1599545
29 January 2002
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1482109
29 March 2001
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1458839
20 December 2000
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1062774
5 December 2000
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1457854
29 November 2000
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 34712
14 March 2000
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1048501
22 March 1999
Initial Construction-Excluding Oversight
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1467113
30 July 1998
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 122207
1 May 1998
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 59832
9 April 1998
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 22716
18 March 1998
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 775314
18 March 1998
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1110336
5 March 1997
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 473788
26 December 1996
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1095194
17 January 1996
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1183523
10 August 1995
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1192810
10 April 1995
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 843736
20 April 1994
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 851662
21 October 1993
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 643336
18 October 1993
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2004
28 May 1993
Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 839588
16 May 1993
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1147544
12 May 1993
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 146509
23 April 1993
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1373837
2 April 1993
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1389619
8 January 1993
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1452923
5 October 1992
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1243803
11 July 1992
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 956005
20 June 1992
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 948153
31 May 1992
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 144535
12 May 1992
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 494530
11 May 1992
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 350555
8 May 1992
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1261846
28 April 1992
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1268908
19 April 1992
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1403545
4 April 1992
Damage Survey · Examination of Repairs
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1252949
21 November 1991
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1248047
8 October 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 483664
24 June 1991
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1215644
16 May 1991
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1222940
7 May 1991
Damage Survey
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1227246
19 April 1991
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1214069
5 April 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 923532
28 March 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1218493
27 March 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1215731
15 February 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1224529
11 February 1991
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 904678
7 February 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1215165
17 January 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1240604
23 December 1990
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 917026
1 December 1990
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1223005
8 September 1990
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 902759
5 September 1990
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 927159
22 August 1990
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1238503
21 May 1990
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 899876
26 April 1990
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1230090
22 April 1990
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1222170
4 January 1990
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 900147
14 October 1989
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 890705
8 August 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1348836
21 June 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1044524
17 May 1989
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1352170
16 May 1989
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 888143
18 April 1989
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1349208
6 April 1989
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 887411
7 March 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1199603
2 February 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1036734
25 January 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1207064
24 January 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 895636
9 January 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1044728
6 July 1988
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 894551
5 July 1988
Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 891918
29 April 1988
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1346862
29 December 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1008011
28 December 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1008010
28 October 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1019648
27 October 1987
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1018500
16 July 1987
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1325426
27 April 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1018217
14 April 1987
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1308894
5 March 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1009340
11 February 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1012589
7 January 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1318539
6 January 1987
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1318702
6 May 1986
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 985602
29 April 1986
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1308783
24 April 1986
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1296402
15 April 1986
Damage Survey
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1307687
30 December 1985
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1318179
22 October 1985
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1300408
2 October 1985
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1300738
19 April 1985
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1290665
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 May 2024
Resolved
The general strength of the hull must be sufficient for the draught corresponding to the freeboard assigned and must be approved by the Commandant. Ships build and maintained in conformity with the requirements of a classification society may be recognized by the commandant as possessing adequate strength. Vessel reported a 4-6" crack in the dividing bulkhead of the #6/#7 Port Ballast tank. Vessel is to survey entire #6/#7 Port Ballast tank bulkhead to determine overall condition/thickness and to make proper repairs to good metal in Marblehead, OH. Repairs must be to the satisfaction of the Coast Guard and Class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2024
Resolved 22 May 2024
Resolution: Repair completed and NDT conducted; all Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 May 2024
Resolved
"Mushroom" vent closures on stbd quarter are seized. Correct to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2024
Resolution: Received objective evidence of properly functioning vent closures.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 15 May 2023
Resolved
Pipe, tubing, pipe joining fittings, and piping system components, shall meet material and standard requirements of subpart 56.60 and shall meet the certification requirements of part 50 of this subchapter. Vessel master discovered a wasted hole in #7 STBD Ballast tank piping. Vessel to proceed to Marine City, MI to replace Straub Coupling with 12" welded ring double until permanent repairs can be made during next winter lay-up (2024).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 29 May 2023
Resolution: Received class report attesting to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 April 2023
Resolved
Two rivets located on the lap of frame #31, located about 12' above the turn in the #1 Port ballast tank, are loose and leaking water into the tank. Repair to the satisfaction of Class/Coast Guard prior to conducting commercial operations after transiting to Cleveland, Ohio for repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2023
Resolved 2 April 2023
Resolution: ABS Surveyor Tozzi, inspected and accepted the repairs as satisfactory. The deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 25 April 2022
Resolved
Vessel is discharging water into the stbd pump room, near the stbd #9 ballast tank. Vessel is to make permanent repairs and stop the water intrusion into the pump room prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2022
Resolved 25 April 2022
Resolution: Received class surveyor report attesting to the crop/renew of wasted sounding piping and the capping it off to prevent further water intrutsion. (attached)
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 March 2022
Resolved
Cracks noted on bulkheads between balast tanks #2 & #3 Port, #4 & #5 Port, and #2 & #3 Starboard. Repair damage to the satisfaction of Coast Guard or Class, prior to departing MSU Cleveland's zone.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2022
Resolved 17 March 2022
Resolution: ABS Cleveland, inspected and approved repairs as being satisfactory. Deficiency is cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2022
Resolved
ALL WIRES MUST BE TERMINATED IN AN ENCLOSURE. MULTIPLE DEAD END, EXPOSED WIRES WERE LOCATED IN THE OVERHEAD WIRE RACKS AT THE FORWARD END OF THE PORT TUNNEL. WIRES DISCONNECTED FROM SERVICE SHOULD BE PULLED THROUGH WIRE RUNS AND REMOVED OR TERMINATED IN A JUNCTION BOX.
46CFR111.60-11(a)
Action required: 705 - Other - as specified
Due 2 March 2023
Resolved 2 March 2023
Resolution: Deaded wired have been removed or terminate in an appropriate enclosure. The deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 November 2021
Resolved
A survey shall be made when a defect is discovered which
affects the efficacy of equipment, or whenever any
important repairs are made. The survey shall insure the
repairs have been effectively made, the material and
workmanship of repairs are satisfactory, and that the
vessel complies with the regulations in this subchapter.
The vessels Starboard #4 & #5 ballast tank have free communication of water. Make repairs and test to
the satisfaction of Class prior to departing, Presque Isle, MI.
Action required: 705 - Other - as specified
Resolved 16 December 2021
Resolution: recieved ABS survey atttesting to repairs
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 September 2020
Resolved
CO2 was expended during a fire. Replace spent CO2 to meet the requirements of the COI, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2020
Resolved 13 September 2020
Resolution: County Fire replenished and reinstalled CO2 bottles IAW the vessel's COI. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2020
Resolved
After the vessel experienced a fire in the generator space, must prove proper operation of the generators and vital systems prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2020
Resolved 13 September 2020
Resolution: Generators and associated equipment tested satisfactory. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 March 2020
Resolved
#8 Port Ballast Tank frame #167 box patch: Submit repair proposal to the cognizant OCMI for approval of permanent repairs. Repairs shall be completed to the satisfaction of the attending CGMI/Class Surveyor prior to 28FEB2021.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 February 2021
Resolved 16 March 2021
Resolution: completed during winter lay-up. supporting docs are uploaded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 March 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2020
Resolved 14 May 2020
Resolution: COI Inspection complete.
Deck/Cargo › Ballast › Pumps
Issued 22 February 2018
Resolved
Ballast pump excessively leaking while in operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2018
Resolved 26 February 2018
Resolution: Repacked ballast pump shaft
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 February 2018
Resolved
06 Hatch closing devices missing. Replace in kind.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2018
Resolved 26 February 2018
Resolution: Repaired and replaced hatch closures
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 October 2017
Resolved
Vessel crew identified 2 small cracks in the lower inboard section of the bulkhead separating ballast tanks #6 and #7. Vessel authorized to transit to Marblehead, OH to complete final repairs to the satisfaction of the MSU Toledo Marine Inspector and Class Surveyor.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 16 February 2018
Resolution: Multiple plates were used to repair bulkhead and water was used in adjacent void for testing. The test method filled the adjacent tank with 10 ft of water. The insert measured 52’’ in height vertically. The inserts were subjected to 4.3 PSI hydrostatic.
Construction/Loadline › Structures › Door
Issued 29 February 2016
Resolved
Service all wtd's, renew gaskets, adjust dogs as appropiate and provide documented verification by Master or First Mate of satisfactory calk testing . Report to be provided to Sector Buffalo, NY.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 14 July 2016
Resolution: Inspected all exterior watertight doors. All were found to be in satisfactory condition, and the deficiency was cleared.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 February 2016
Resolved
Portable Fire extinguishers brackets throughout barge require securing pins or appropriate lead seal for brackets and replace rubber bumpers where missing.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 12 April 2016
Resolution: Portable fire extinguishers have the appropriate seals and are securely fit into their brackets. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 29 February 2016
Resolved
Both port and starboard side cables for lifting arm swing davits require renewal wire splices & cables found in poor unservicable condition.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 12 April 2016
Resolution: Port & Starboard swing davits have new cable and turnbuckel assemblies attached. Deficiency cleared.
Construction/Loadline › Hull › Weld
Issued 29 February 2016
Resolved
v & weld of the #7 Starboard aft bulkhead
Due 24 March 2016
Resolved 24 March 2016
Resolution: Received notification from class, POC and shipyard attesting to sat completion.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 October 2015
Resolved
Make permanent repairs to inboard longitudinal bulkhead/tanktop connection angle at frame 127 in the starboard walking tunnel where temp repairs exist (2 fractures)
Condition: Improper/Lack of Maintenance
Due 1 February 2016
Resolved 8 February 2016
Resolution: Insert satisfactory, Hydro test completed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 October 2015
Resolved
Make permanent repairs by insert to temporary repair at longitudinal bulkhead/tanktop transition within the starboard walking tunnel at frame 143 inboard side where a doubler exists.
Due 1 February 2016
Resolved 8 February 2016
Resolution: Insert satisfactory, Hydro test completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 September 2015
Resolved
Bulkhead between port ballast tanks #4 and #5 had an approximately 6" crack along the bottom.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 9 September 2015
Resolution: Visually inspected repair from #4 BT, then from #5 BT w/4' of water in BT #4. Repairs are Sat. Removed deficiency.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2015
Resolved
Repair bent stbd aft railing IWO work boat
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Hand rail has been re-welded and stiffened, all sat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 March 2015
Resolved
Provide proof of annual liferaft servicing and install servicing decal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2015
Resolution: Witnessed servicing of liferafts at Samsel Supply, CO, Cleveland, OH. Rafts are onboard and stowed correctly, all sat.
Lifesaving › Immersion Suits › Marking
Issued 11 March 2015
Resolved
Service all immersion suit zippers and properly stencil vessel name
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Immersion suits, serviced and labeled correctly, all sat.
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 March 2015
Resolved
Repair sound powered phone enclosure door handle located in forward bow thruster room.
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Phone has been repaired and tested, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 March 2015
Resolved
Replace improper portable hand fire extinguisher bracket in forward bow thruster room.
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Bracket re-newed, all sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 March 2015
Resolved
Starboard aft embarkation station light and switch inoperable, replace wasted parts and prove proper operation.
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Light works as designed, all sat.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 March 2015
Resolved
Provide positive closures (latches) to forward paint locker manual ventilation closures, repair door latch to eliminate gap when closed
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: Closures installed, all sat. Gasket installed on door, all sat.
Engineering › Pressure Vessel › Relief Valve
Issued 11 March 2015
Resolved
Prove proper operation of pressure relief valve on tunnel service UPV located in froward bow thruster room.
Action required: 705 - Other - as specified
Due 30 March 2015
Resolved 25 March 2015
Resolution: R/V tested, all sat. 125 psi.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 January 2015
Resolved
Forward Paint Locker is protected with a Fixed Manual CO2 system. Ventilation closures are activated upon destruction of heat sensitive fusible links. There are no means to operate the closures manually from outside the space. Requirement written to provide a reliable means to close the two ventilation dampers from outside the space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2015
Resolved 2 March 2015
Resolution: Ventilation dampers installed external to the space.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 June 2014
Resolved
Permanent repairs to be completed and accepted by an attending ABS surveyor and an attending representative of OCMI of Sector Detroit to cracks found in the two starboard dividing bulkheads. One located in ballast tanks #2 S and #3 S and one in #5 S and #6 S. See activity summary for details.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 21 June 2014
Resolution: Attended vessel verified all repairs to #2/3 and #5/6 tank transverse blkhds satisfactory. Witnessed test of the slope plate transition to ballast bulkhead longitudinal fracture below #13 deck hatch by ballast tank filling. All sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 April 2014
Resolved
Cracks were found along the bulkhead seperating #6 and #7 starboard ballast tanks. Make repairs to satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2014
Resolution: Marine Inspector inspected and witnessed water testing of repairs along with Class surveyor. Repairs are satisfactory and deficiency is cleared.
Construction/Loadline › Hull › Side Shell
Issued 16 June 2013
Resolved
Two cracks, one 6" and one 12", were noted on the shell plate of the #9 port ballast tank.
Action required: 705 - Other - as specified
Due 16 June 2013
Resolved 16 June 2013
Resolution: Upper 6" crack received exterior fillet weld only while the lower crack received interior and exterior full penetration weld. Def. cleared.
Construction/Loadline › Hull › Hull Plating
Issued 24 July 2012
Resolved
Make repairs to hull plating in #3 p/s ballast tank underneath frame #51.
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 20 August 2012
Resolution: Vessel added cement box patch to hull plating in #3 port ballast tank
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2011
Resolved
Conduct permanent repairs to a pin hole and one 6-inch fracture on the bottom of the bulkhead between the #4 and #5 ballast tanks to the satisfaction of a CG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 13 October 2011
Resolution: Flooded #4 port ballast tank 2 foot past fracture. Observed for 10 minutes with no issues.
Construction/Loadline › Hull › Transverse Frame
Issued 29 December 2010
Resolved
Make permanent repairs to 12" vertical weld fracture, angle bracket vertical fracture, and permanent repairs to 3 broken rivets by way of #43 STBD frame below the weather deck at tank top deck level as noted in CG-835 and Sector Sault Permit to Proceed upon arrival into Huron, OH. To the satisfaction of the attending CG Marine Inspector or Class Surveyor.
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 1 January 2011
Resolution: Vertical and angle bracket weld fractures gouged and rewelded. Weldment laid around bolts.
Construction/Loadline › Hull › Side Shell
Issued 26 December 2010
Resolved
Make permanent repairs to ring welded rivets IWO stbd anchor pocket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 1 March 2011
Resolution: Accepted repairs authorized by class
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2009
Resolved
Transverse bulkhead separating # 4 & 5 ballast tanks contained numerous inserts and appeared wasted. Issued 835 requiring owner to perform gauging.
Condition: Improper/Lack of Maintenance
Due 30 May 2009
Resolved 13 May 2009
Resolution: Report performed and submitted 5/13. Readings revealed some deterioration but overall were above 75% per ABS Part 7 Section 4. Fleet engineer agreed to continue to monitor this issue.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 17 December 2008
Resolved
Prior to operation of the Luddel deicing boiler demonstrate proper operation of the alarms and shut downs IAW 46 CFR 63.15-7. Currently the water heating boiler would not restart following the testing of the flame failure alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2009
Resolution: Received an email from the chief engineer verifying proper operation of the deicing boiler alarms and shut downs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 12 March 2007
Resolved
FWD paint locker 100 system removed. Issued requirement to reinstall.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 20 March 2008
Lifesaving › Inflatable Liferafts › Markings
Issued 17 March 2005
Resolved
Install liferaft launching instruction placards near both liferafts. Fax or mail letter, signed by the Master, to MSD [name withheld] indicating that the placards are in place.
Condition: Unknown
Due 17 April 2005
Resolved 19 April 2005
Resolution: Received e-mail from vessel rep [name withheld] indicated new placards were installed
Construction/Loadline › Hull
Issued 21 July 2003
Resolved
Make repairs and complete all repair work-list items as issued in activity narrative dated 29July2003. All pending items must be completed prior to vessel receiving a Credit Dry-Dock Examination. All repairs to be to the satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: Stiffener
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 18 March 2004
Resolution: All repairs completed at Bay Shipbuilding Corp, Sturgeon Bay, WI to the satisfaction of ABS.
Lifesaving › Lifebuoys
Issued 4 April 2003
Resolved
renew batteries in lifebuoy lights LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2003
Resolution: New batteries installed
Electrical › Electrical Distribution System (service)
Issued 4 April 2003
Resolved
Remove old vent duct on top of anchor windless resistor bank LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2003
Resolution: Removed old vent cover.
Engineering › Bilge Water Management System › Piping
Issued 4 April 2003
Resolved
Cap off 4" pipes, which run from pump room to upper aft machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2003
Resolution: Blank flanges installed in lines.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 April 2003
Resolved
Label or place an "Not an Exit" sign in both port and stbd cargo void spaces.
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 20 April 2003
Resolution: Received faxed letter from [name withheld], Jr. [name withheld] indicating that a "not an exit sign" has been installed in both tunnels.
Electrical › Lighting (service)
Issued 13 January 2003
Resolved
Replace missing covers (glass or plastic) on all light fixtures in FWD anchor room and in both storm tunnels. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 20 April 2003
Resolution: Received faxed letter from [name withheld], Jr [name withheld] indicating that all fixtures have globes.
Lifesaving › Lifebuoys
Issued 29 March 2002
Resolved
Rejected one life ring. Corrected on the spot.
Condition: Damaged By Earlier Event
Due 29 March 2002
Resolved 29 March 2002
Resolution: Replaced.
Accommodation/Occupational Safety
Issued 22 March 1999
Resolved
Provide specifications to CG that indicate that the fiberglass ladder stepsused up forward are approved for use on inspected vessels or replace with steps that are steel or equivalent.
Condition: Unknown
Due 30 April 1999
Resolved 4 June 1999
Accommodation/Occupational Safety
Issued 2 April 1993
Resolved
REPAIR THE VENT COVER TO THE FORWARD GALLEY.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 2 April 1993
Resolved
BLANK THE OPENINGS IN DISTRIBUTION PANEL L-13, FORWARD HOUSE PASSAGEWAY.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 2 April 1993
Resolved
DEMONSTRATE OPERATION OF THE NAVIGATION LIGHT AUDIBLE AND VISUAL ALARMS.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993
Resolved
MARK THE ENTRANCE TO THE SPACE CONTAINING THE CO2 MANIFOLD IAW 46 CFR 97.37-13(a).
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993
Resolved
MARK THE SPAR DECK FIRE STATIONS AND THE FIRE STATION ON THE MAIN DECK IN THE FORWARD HOUSE IAW 46 CFR 97.35-15(a).
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993
Resolved
PROVIDE A PROPER BAILER FOR THE #2 LIFEBOAT.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993
Resolved
PROVIDE MANROPES FOR THE #1 LIFEBOAT OF SUFFICIENT LENGTH TO MEET 46 CFR 94.25-15(b)._x001C_ _x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 2 April 1993
Resolved
REPAIR OR REMOVE THE MAGNETIC COMPASS ON THE "TEXAS DECK".
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 2 April 1993
Resolved
PROVIDE A LATCH ON THE DISTRIBUTION PANEL IN THE DUNNAGE ROOM COMPANIONWAY.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 2 April 1993
Resolved
SET AND SEAL SAFETY VALVE IN THE PRESENCE OF A CG MARINE INSPECTOR PRIOR TOOPERATING AUX BOILER.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 2 April 1993
Resolved
MAKE PERMANENT REPAIRS TO LEAKING TUBES (2) IN THE BOTTOM END OF THE AUX BOILER AND HYDRO TO 1.5 MAWP PRIOR TO PLACING BOILER IN SERVICE. HYDRO TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 2 April 1993
Resolved
REPAIR OR RENEW THE FOLLOWING FLEXIBLE APPLIANCE CORDS: GALLEY TOASTER,_x001C_ HOT PLATE, PORT TUNNEL HEATER, FORWARD HOUSE EXTERIOR LIGHTS, AND STARBOARDTUNNEL HEATER (FRM 83)._x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 2 April 1993
Resolved
REPAIR THE SOUND POWERED PHONE CORD AT THE AFT WINDLASS STATION (INSULATIONDAMAGED WHEN PINCHED IN COVER, EXPOSING WIRING).
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993
Resolved
DEMONSTRATE OPERATION OF THE GENERAL ALARM BELL AT FRM 131, STARBOARD TUNNEL.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Documentation
Issued 2 April 1993
Resolved
SUBMIT A FIRE PLAN TO OCMI BUFFALO FOR APPROVAL. PLAN MUST CONTAIN THE INFORMATION REQUIRED BY 46 CFR 97.36.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993
Resolved
MARK ALL FIRE MAIN BRANCH LINES AND CUTOUT VALVES IAW 46 CFR 97.37-10.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993
Resolved
MARK THE LIFERAFT STATIONS IAW 46 CFR 97.37-40.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993
Resolved
STENCIL LIFEBOATS ON EACH SIDE AS REQUIRED BY 46 CFR 97.37-37.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 19 April 1992
Resolved
DO NOT OPERATE YOUR AUXILIARY BOILER UNTIL A HYDRO, AUTOMATION TESTS, AND SAFETY VALVE TESTS ARE ACCOMPLISHED UNDER THE SUPERVISION OF A COAST GUARD MARINE INSPECTOR, AND IN NO CASE LATER THAN 15DEC92.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Lifesaving
Issued 19 April 1992
Resolved
CONTACT A COAST GUARD MARINE INSPECTOR NOT LATER THAN 30 JUNE 1992 AND MAKEVESSEL AVAILABLE FOR AN INSPECTORS RIDE._x001C_
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Electrical
Issued 19 April 1992
Resolved
REPLACE TWO EMERGENCY LIGHTS AND DEMONSTRATE THEIR PROPER OPERATION IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR NOT LATER THAN 30 APRIL 1992.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Construction/Loadline
Issued 4 April 1992
Resolved
CROP AND RENEW FRAMES 1 TO 4 PORT AND 1 TO 3 STARBOARD IN FOREPEAK IN WAY OF 12 FT WATERLINE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR ATNEXT DRYDOCKING FOR ANY REASON BUT NO LATER THAN 31JUL93.
Condition: Unknown
Due 4 April 1992
Resolved 4 April 1992
Construction/Loadline
Issued 7 May 1991
Resolved
REPAIR RIVETS IN WAY OF DOUBLE-RIVETED LAP SEAM FRAMES 66-68 AND WEB FRAME 67 FIRST SHELF BELOW MAIN DECK 3 PORT BALLAST TANK NEXT VISIT DULUTH BUT NOLATER THAN 21MAY91.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Engineering
Issued 22 August 1990
Resolved
REPAIR LEAKING HYDRAULIC SEAL IN BOW THRUSTER. UNIT IS TO BE SECURED IF OILIS DISCHARGING INTO WATER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 26 April 1990
Resolved
PRIOR TO USE, AND IN NO CASE LATER THAN 01 DECEMBER 1990, MAKE PERMANENT REPAIRS TO THE REFRACTORY IN THE DONKEY BOILER TO THE SATISFACTION OF A U S COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 22 April 1990
Resolved
PROVIDE MEANS OF TESTING EMERGENCY LIGHTS IN ENGINEROOM WITHOUT LOSS OF PROPULSION PLANT.
Condition: Unknown
Due 22 April 1990
Resolved 22 April 1990
Engineering
Issued 22 April 1990
Resolved
PERFORM HYDRO OF AUX BOILER AND DEMONSTRATE PROPER OPERATION OF AUTOMATION.
Condition: Unknown
Due 22 April 1990
Resolved 22 April 1990
Lifesaving
Issued 22 April 1990
Resolved
PROVIDE SMOKE ALARMS FOR ALL STATEROOMS.
Condition: Unknown
Due 22 April 1990
Resolved 22 April 1990
Electrical
Issued 22 April 1990
Resolved
PROVIDE EMERGENCY LIGHTS FOR BOTH TUNNELS (DUAL LIGHTS AT CENTER OF TUNNEL AND ONE LIGHT AT EACH END OF TUNNEL).
Condition: Unknown
Due 22 April 1990
Resolved 22 April 1990
Engineering
Issued 6 April 1989
Resolved
PLACE PORT AND STARBOARD JERGUSON LIGUID LEVEL INDICATORS BACK IN PROPER OPERATION.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Deck/Cargo
Issued 6 April 1989
Resolved
PROCURE AND PLACE ON BOARD AN OILY WASTE SHORE DISCHARGE FLANGE AS DISCRIBED IN 33CFR155.430. UPON COMPLETION NOTIFY IN WRITING TO OCMI CLEVELAND,OHIO.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Engineering
Issued 14 April 1987
Resolved
HYDRO TEST AUX BOILER, TEST COMBUSTION CONTROLS AND SET SAFETY VALVE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
REMOVE FUEL OIL TRANSFER HOSES FROM VESSEL OR DEMONSTRATE COMPLIANCE WITH THE REQUIREMENTS IN 33 CFR 155.800.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Electrical
Issued 14 April 1987
Resolved
INSTALL RED FLASHING LIGHTS AND ADDITIONAL GENERAL ALARM BELLS IN THE MAIN MACHINERY SPACES. BELLS: PORT & STBD LOWER LEVE, FWD LIGHTS: SHAFT ALLEY FWD OF MAIN BOILERS, OPS DECK & GENERATOR FLAT MAIN DECK LEVELS
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987