Records from 2004 to 2025. Most recent: inspection, 27 March 2025.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 March 2025
Resolved
Have a nozzle that has a 1/2 inch solid stream orifice or a combination nozzle approved by the Commandant in
accordance with § 162.027-6 of this Chapter. The nozzle must be bronze or another material that has strength and
corrosion resistance properties equal to those of bronze. Fire hose nozzle did not provide adequate stream of water when tested. Replace nozzle and provide test to the satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 2 April 2025
Resolution: Vessel installed new nozzle.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 March 2025
Resolved
Each hydrostatic release unit, other than a disposable unit, must be serviced: Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 2 April 2025
Resolution: New hydrostatic release installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 March 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Stbd shaft drip identified at more than a drip every 2 seconds. Shaft seal drip was deemed excessive. Adjust shaft seal packing to satisfaction of attending marine inspector. Vessel correct on site to a drip every 10 seconds.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2025
Resolution: Vessel adjusted packing on site.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 March 2025
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel provided four alcohol test strips on site.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 27 March 2025
Resolution: Vessel repalced expired test strip with four new alcohol test packets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 February 2025
Resolved
During sea trial active water ingress was observed in the fore peak space coming from the starboard side frame (sistered) second aft from the bow. Submit a repair proposal to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 20 March 2025
Resolution: MSD Santa Barbara completed a satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 March 2024
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Vesse's fixed power pump did not achieve suction during bilge manifold suction test. Troubleshoot and repair bilge pump motor and provide test of bilge suction system to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Replaced motor start controller. Tested all mainfold suction points. All Sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 March 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel master did not have radio operator permit. Provide valid radio operator permit to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 26 March 2024
Resolution: Vessel master provided proof of valid radio operator permit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2024
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. Vessel had only 6 of the required 7 child sized life jackets on board. Vessel provided the additional (1) child size life jacket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
Resolution: Vessel provided the missing (1) child size life jacket
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessel had adult life jackets stored with children life jackets. Vessel separated the adult from children life jackets and relabeled the benches.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
Resolution: Vessel seperated adult and children jackets and relabeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Starboard fuel shutoff valve did not close completely when tested. Adjust valve and demonstrate proper operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Vessel adjusted fuel shut off and demonstrated proper operation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 March 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel's aspirin was expired. Provide current medications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Vessel provided new aspirin.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 March 2023
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Lazarette hatch cover was missing captive chain. Provide means to secure its loss.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Vessel provided a cord to act as a hatch retaining device.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 January 2022
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements:
(1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license.
(2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. Vessel master did not have a FCC radio operator permit.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 25 February 2022
Resolution: Vessel master provided his permit.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 January 2022
Resolved
Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. The alarm must be audo and visual at the operating station. Installed bilge alarm audible not functioning properly. Repair and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 23 February 2022
Resolution: Vessel repaired and demonstrated operation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 January 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Rot was observed in the engine room overhead on both the port and starbaord sides, on the outboard starboard side engine mounts, in the lazarette overhead throughout, and in the lazarette vertical support stanchion on the starbaord side. Remove rot to good wood. Treat remaining wood. If necessary, provide repair proposal for any areas where decay was ectesnive enough to require removal of large amounts of wood.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 23 February 2022
Resolution: Vessel scraped and treated areas.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 April 2021
Resolved
Life floats found with fraying grab lines, vessel name faded on oars, and missing the tether line between the two forward rafts. Provide tether line, oars stenciled with vessel name, and serviceable grab lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 15 April 2021
Resolution: Vessel tethered forward floats together, replaced grab lines and re-stenciled vessel name on oars.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 April 2021
Resolved
Provide battery box cover for batteries located in forward stores.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 15 April 2021
Resolution: Vessel provided battery box cover.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 April 2021
Resolved
Provide covers for lighting fixtures located in the forward stores and bunk room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 15 April 2021
Resolution: Vessel provided covers for lighting fixtures.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 April 2021
Resolved
Provide first aid kit containing all items listed in 46 CFR 160.041.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 15 April 2021
Resolution: Vessel ordered additional items for first aid kit.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2021
Resolved
Remove or modify galley mats obstructing means of escape from bunkroom. Bunkroom is not accessible to passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 15 April 2021
Resolution: Vessel cut out mat areas to allow egress.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 January 2021
Resolved
Treat rot on frame under port and starboard shafts in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 January 2021
Resolution: Rot was scraped and treated with 4 coats of penetrating epoxy and 1 coat of epoxy primer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2021
Resolved
Vessel is to complete a sea trial prior to carrying passengers for credit drydock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2021
Resolution: Vessel completed post dry dock sea trails, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 June 2020
Resolved
Provide proper amount of flares.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2020
Resolution: Flares provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2020
Resolved
Prove proper operation of bilge alarm system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Bilge alarm system working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 June 2020
Resolved
Provide proper weak link for life floats.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Weak link provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 June 2020
Resolved
Provide proper lines for water lights on all 3 life floats.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Proper lines provided for water lights on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 June 2020
Resolved
Provide dunnage between stacked life floats.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Dunnage provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2020
Resolved
Provide proper length of throw line on ring buoy with a corrosion resistant clip.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Throw line with clip rovided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2020
Resolved
Provide documentation of galley hood consideration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: Recieved letter.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2020
Resolved
Mount extinguisher in galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2020
Resolution: Extinguisher mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2020
Resolved
Provide non-combustible waste bins in accommodation spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: Metal trash cans provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 June 2020
Resolved
Repair fire hose nozzle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: Fire hose nozzle repaired.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 June 2020
Resolved
Provide proper size bell.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: Bell provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2020
Resolved
Repair steering gear block assembly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: Steering gear block repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 June 2020
Resolved
Provide FCC operators permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: FCC operator's permit verifed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2020
Resolved
Provide proof of fire boy servicing and testing for unit in gen. rm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: O/O removed fire boy as its not required due to genset being under 50hp.
Lifesaving › Lifefloat › Serviceable
Issued 11 April 2018
Resolved
Repair bird damage to life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 16 August 2018
Resolution: Damage repaired.
Lifesaving › Lifefloat › Painter
Issued 11 April 2018
Resolved
Renew painter lines for life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 16 August 2018
Resolution: Painter lines renewed.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 11 April 2018
Resolved
Connect GPS to VHF-DSC radio or install VHF-DSC radio with built-in GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 16 August 2018
Resolution: Installed new radio.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2018
Resolved
Update first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 11 April 2018
Resolution: First aid kit updated.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 April 2018
Resolved
Properly log man-overboard, fire, and abandon ship drills and epirb test.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 11 April 2018
Resolution: Log book updated.
Stability › Weathertight Integrity › General
Issued 8 February 2017
Resolved
Install closure devices on E/R hatch to prevent loss of hatch to sea.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 30 March 2017
Construction/Loadline › Hull › Hull Plating
Issued 27 January 2017
Resolved
Prior to carrying passengers, determine source of forepeak flooding and make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 8 February 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 January 2017
Resolved
Make vessel/crew available for MOB drill.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Engineering › Bilge Water Management System › Hose
Issued 27 January 2017
Resolved
Double-clamp bilge pumping system hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Engineering › Bilge Water Management System › Hose
Issued 27 January 2017
Resolved
Replace bilge suction hose in E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 January 2017
Resolved
Provide current copies of U.S. COast Pilot & USCG Light List
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 27 January 2017
Resolved
Make collision bulkhead watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 27 January 2017
Resolved
Prove proper operation of port main engine.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Communications › Radio Communications › EPIRB
Issued 27 January 2017
Resolved
Mark expiration date on EPIRB hydro release
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 February 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 December 2016
Resolved
Laz: genset exhaust hose configuration is casuing crimping & chafing of hoses. Re-configure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 December 2016
Resolved
Laz: move FireBoy engine shut-down controls to dry space iaw mfg instructions.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 27 January 2017
Resolution: Relocated to storage closet in aft port area of bunkroom
Stability › Unintentional Flooding › General
Issued 27 December 2016
Resolved
Secure bait tank pump in E/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Engineering › Bilge Water Management System › Pump
Issued 27 December 2016
Resolved
E/R: secure portable bilge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 December 2016
Resolved
E/R: repair leaking wet exhaust junction (stbd side outboard_.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 December 2016
Resolved
E/R: plug all openings in genset panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Construction/Loadline › Hull › Side Shell
Issued 27 December 2016
Resolved
Bunk Room: install inspection ports on stbd side as on port.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 27 January 2017
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 December 2016
Resolved
Explain (and ensure Master is aware) of how to operate MSD valves/discharge configuration.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Stability › Unintentional Flooding › General
Issued 27 December 2016
Resolved
Bunkroom: stbd aft upper level: determine source of standing water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 6 January 2017
Resolution: Water was determined to be entering void via vent in gunwale.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 5 April 2016
Resolved
E/R: All electrical panels must close securely.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 April 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 April 2016
Resolved
Provide results for pre-employment drug testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016