Records from 1985 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 97
17 March 2026
COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296063
16 August 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8218500
16 June 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8168029
13 February 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8083780
16 September 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8003738
13 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7911637
12 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7790501
20 March 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662861
2 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7619298
16 May 2022
Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7451885
24 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7157985
1 February 2021
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134027
28 April 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6946118
14 April 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6938927
23 March 2020
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930550
3 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6827169
1 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6732051
7 May 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6678653
7 May 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6680657
10 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6537149
18 July 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6483915
26 June 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6456892
15 May 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384267
13 July 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6208384
7 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6146865
13 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6101830
4 April 2016
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829245
12 June 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4836458
21 May 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4283471
24 January 2012
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4231865
5 January 2009
Examination of Repairs · Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3388913
4 June 2008
Re-Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3191465
31 May 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2930585
27 February 2007
Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2873329
5 April 2006
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2613910
2 June 2005
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2351351
8 April 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2323925
29 March 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2322482
26 October 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2228987
21 October 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2225765
15 October 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2224266
1 October 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2268058
15 June 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2185585
4 June 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2088973
6 February 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001926
14 November 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1948109
28 October 2003
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1937702
19 October 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1947822
29 May 2003
Annual Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1798993
23 April 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1776069
6 December 2002
In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1718677
13 July 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1648583
22 May 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1619417
27 March 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1598055
12 April 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412266
11 April 2001
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1075107
18 April 2000
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1441689
29 March 2000
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1441688
14 May 1999
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1461977
20 April 1998
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1453472
2 June 1997
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1109268
22 April 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1383504
25 April 1996
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1414616
3 August 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1188949
26 April 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1180211
6 July 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 862303
17 May 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 859297
14 April 1994
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385222
27 May 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1370635
29 April 1992
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1260420
4 December 1991
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1252796
24 June 1991
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1216195
19 April 1991
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1220946
6 March 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 998117
19 February 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 915719
14 December 1990
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 917155
6 May 1990
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 916250
7 February 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 907172
8 January 1990
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1243506
24 November 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1230935
18 November 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1242277
17 November 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1218264
26 September 1989
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 898412
12 September 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1040698
20 July 1989
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1210345
13 May 1989
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195515
13 April 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 899224
27 September 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 902247
26 May 1988
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 889369
22 February 1988
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1330008
6 January 1988
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1010132
16 September 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1005921
28 May 1987
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1028768
10 April 1987
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1021212
6 June 1986
Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1296883
10 September 1985
Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1297454
20 May 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1291074
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2024
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI found gauge was broken and the pressure from the fire hose to be insufficient. Replace gauge and adjust pressure on fire pump to meet current regulations. Notify MI once corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 16 May 2024
Resolution: Received video of the fire pump functioning correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found missing guards on one generator and fire pump. Replace missing guards and notify MI once corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 16 May 2024
Resolution: Received an email from the owner with picture's of the deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found several dead-end wires in the engine room and a missing rack lamp with exposed wire. Properly dead-end wires and notify MI once corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 16 May 2024
Resolution: Received an email from the owner with picture's of the all deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 May 2023
Resolved
CO2 system was found to not secure machinery equipment. Reinstall CO2 activated machinery shutdowns.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: Global fire reinstalled CO2 activated machinery shutdowns, witnessed test, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2023
Resolved
02 ring buoy life lines found to be wasted, renew or replace ring buoy lines.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: 02 lifebuoys replaced by owner.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 May 2022
Resolved
Vessel's general alarm (GA) is inoperable. Repair or replace the GA so that it may adequately alert the berthing area occupants of emergency to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2022
Resolution: Witnessed a satisfactory test of a newly installed PA system in the two passenger berthing hallways.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 May 2022
Resolved
Emergency lighting in the forward berthing and galley is missing. Install adequate emergency lighting in the galley and forward berthing areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Witnessed satisfactory test of emergency lighting in both passenger berthing hallways and galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 May 2022
Resolved
The sight-glasses for the 03 diesel fuel tanks were missing their associated guards. Replace the missing guards to the satisfaction of the attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 2 June 2022
Resolution: Vessel installed new guards on sightglasses.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022
Resolved
Remove outlet extender and install permanent outlets in wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 2 June 2022
Resolution: Vessel replaced with a UL approved surge protector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2022
Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. The vessel's fire hydrant's valve has a broken handle. Replace the hydrant valve handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 2 June 2022
Resolution: Vessel installed new valve with new handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2022
Resolved
Vessel found to have an active fuel leak at the base of the sight gauge on the STBD reserve fuel tank. Tank shall not be in service until leak is repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 13 May 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 March 2021
Resolved
Prove proper operation of starboard sie fuel shutoff valve reach rod, access hatch stuck shut.
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 24 March 2021
Resolution: Hatch opened.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2021
Resolved
Install spanner wrench at fire hose station. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 March 2021
Resolved
Provide accurate instructions for the deployment of the fixed fire system to include "pull pin". Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 13 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 March 2021
Resolved
Install vent closures for machinery space. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Fabricated and installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2021
Resolved
Clean galley vent ducting. Due 24Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2021
Resolved
Install light switch cover on galley pantry light switch. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 26 March 2021
Resolution: Cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2021
Resolved
Install blank cover on DC panel. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Switch installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 March 2021
Resolved
Prove proper operation of stern light. Due 24Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Bulb replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 March 2021
Resolved
Make life floats float free. Cleared on the spot.
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 24 March 2021
Resolution: Stowed properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 March 2021
Resolved
Properly label ring buoys with vessel name. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2021
Resolved
Plug hole in machinery space bulkhead where identified. Due 24April2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Cover installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 March 2021
Resolved
Provide distress signals IAW 46CFR180.68. Due 24Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 March 2020
Resolved
Repair or replace the 02 worn life buoys as identified, to include: retro-relfective tape, all lines, and vessel name as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2020
Resolution: Repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 March 2020
Resolved
Provide FCC Marine Radio Operator Permit for all required licensed crew members. Vessel may not operate more than 1000 feet from shore until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 28 April 2020
Resolution: Provided FCC certs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 March 2020
Resolved
Fire pump gauge was indicating an output pressure of approximately 20 PSI. Fire pump is required to provide a pressure output of at least 60 PSI. Prove that fire pump is able to provide a pressure output of at least 60 PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2020
Resolved 28 April 2020
Resolution: Gauge installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 March 2020
Resolved
Provide proof that vessel is enrolled in an approved drug testing consortium for the year 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2020
Resolved 28 April 2020
Resolution: DAPI profe provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 March 2020
Resolved
Vessel's life floats were marked with the wrong vessel's name. Replace the inappropriate vessel name with the correct vessel name on both life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2020
Resolved 28 April 2020
Resolution: Marked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 23 March 2020
Resolved
Provide vessel with a waste management plan and post in an appropriate area on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2020
Resolved 28 April 2020
Resolution: WMP Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Resolved 14 April 2020
Resolution: Vessel rep provided one-line drawing, Sector San Diego reviewed and placed in permanent file.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Resolved 3 October 2019
Resolution: Educated vessel captain.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Remove extension cord supplying galley coffee pot.
Action required: 10 - Deficiency Rectified
Resolved 3 October 2019
Resolution: Coffee pot was moved and extension cord removed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 October 2019
Resolved
Provide 03 fuel tanks with heat resistant tubing and a self closing device. As per Safety Alert 08-19.
Action required: 705 - Other - as specified
Resolved 14 April 2020
Resolution: Vessel rep provided photographs of new sight glasses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Provide Bus A and Bus B panels in engine room with covers to close open access to panels.
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 15 January 2020
Resolution: Vessel rep provided photo of sheet metal guards bolted in to place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Provide blank cover for all missing breakers and sheet metal knock-outs from engine room and galley panels.
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 15 January 2020
Resolution: Vessel rep provided photos of breaker blanks installed in panels.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2019
Resolved
Provide galley with smoke detector as per Sector San [name withheld] Policy #20.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Received picture of installed smoke detector.
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 3 October 2019
Resolved
Clean galley hood casing and vent ducting as per Sector San [name withheld] Policy #20. Establish procedure for cook to clean/inspect hood ducting at least quarterly.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Received photo of cleaned vent ducting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Clean heavy dust/lint from inside galley distribution panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2020
Resolution: Vessel rep provided photographs of cleaned out panel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 July 2019
Resolved
Provide vessel with additional 06 distress signals
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2019
Resolution: Vessel rep provided additional flares
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 July 2019
Resolved
Properly tighten fuel hose connection on both generators
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2019
Resolution: Fuel hoses were properly tightened
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 July 2019
Resolved
Renew fuel hose feeding the port generator Raycor filter
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2019
Resolution: New hose was provided for the port generator
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2019
Resolved
Prove proper operation of life float light
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2019
Resolution: Life float light battery was replaced and functioned properly
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 July 2019
Resolved
Prove operation of fire pump at 60 PSI gauge reading
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: New pressure gauge was installed and tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2019
Resolved
Provide forward bunk compartment with visual high water alarm indicator
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Visual indicator was repaired.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 1 July 2019
Resolved
Provide smoke detectors for all bunk rooms
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Additional smoke detectors were installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 July 2019
Resolved
Provide simple instructions for discharge of CO2 system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Instructions were posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 July 2019
Resolved
Prove operation of port main engine L/O pressure gauge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: new sending unit was installed and gauge operated correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019
Resolved
Provide switchboard with interlock device for generators and shore power
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Interlock device was installed correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2019
Resolved
Remove fuel from port generator and stbd main Raycors
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Fuel was cleaned out.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Provide vessel with updated FCC Safety License
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Safety license was renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Provide vessel with updated FCC Station License
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Station license was renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Provide vessel with FCC Bridge-to-Bridge License
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Bridge-to-bridge license was renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Provide FCC operators permit for licensed masters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 28 April 2020
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2019
Resolved
Label (04) life float paddles with vessel's name
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Paddles were labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 July 2019
Resolved
Attached retaining cable to forward bunk room hatch
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Retaining cable was attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2019
Resolved
Label forward bunk room hatch "ESCAPE" on inside and "EMERGENCY EXIT, KEEP CLEAR" on outside
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Hatch was properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2019
Resolved
Label "FUEL SHUTOFF VALVES" WITH 1 inch lettering
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Fuel shut-offs were labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2019
Resolved
Provide vessel with first aid kit as per 46 CFR 160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: CG approved first aid kit was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 1 July 2019
Resolved
Provide lazarette with copper piping and provide suctions pipes with suitable strainer
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 6 August 2019
Resolution: Laz bilge piping was restored to original and strainer was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 July 2019
Resolved
Replace engine compartment bilge piping where temporary patch was applied
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 11 October 2019
Resolution: Removed soft patch - pipe condition serviceable (operationally tested bilge suction - SAT).
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Provide vessel with and post for crew and passengers to view the following documents: COI, Stability Letter, Waste Management Plan, and two types of life jacket donning placards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 11 October 2019
Resolution: Docs/Certs posted.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
CLSN: Vsl is not broadcasting a Call Sign, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 April 2020
Resolution: Verified.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 18 July 2018
Resolved
Properly de-commision the starboard wing fuel tank and provide a repair plan for approval prior to use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2018
Resolution: starboard wing fuel tank is properly de-commisioned.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 July 2018
Resolved
Properly label label all life savings equipment onboard
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2018
Resolved 20 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 July 2018
Resolved
Conduct underway emergency prior to carriage of passengers for hire.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2018
Resolved
Provide vessel name on stern and forward port and starboard side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 5 July 2018
Resolution: Name was put on vessel.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 12 June 2018
Resolved
Provide final servicing certificate for fixed fire system to include fire detection system/heat detector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2018
Resolved 28 April 2020
Resolution: Repaired.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 12 June 2018
Resolved
Prove galley hood fire system is installed & tested per manufacturer specifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2018
Resolved 28 April 2020
Resolution: Serviced.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 June 2018
Resolved
Provide FCC license (marine operator permit).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2018
Resolved 28 April 2020
Resolution: Provided.
Communications › Public Address System › Announcing Station
Issued 12 June 2018
Resolved
Prove proper operation of PA system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2018
Resolved 28 April 2020
Resolution: Operational.
Fire Fighting › Fire Hoses › Condition
Issued 7 June 2017
Resolved
Replace both fire hoses. Fire hoses found to be leaking due to cracked liner.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Resolution: Vessel owner replaced both hoses; MI witnessed operational test of fire hoses.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 June 2017
Resolved
Fixed fire serviceing last conducted on 13Jul2016. Provide proof of valid fixed fire extinguishing system servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: Owner provided satisfactory proof of installed Fire Servicing Report conducted on 27Jun2017 by Breakwater.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 4 April 2016
Resolved
Provide emergency escape hatch markings for 02 emergency hatches.
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 20 April 2016
Resolution: Owner stenciled escape hatch marking for 02 emergency hatches.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 April 2016
Resolved
Destroy 2 damaged lifejackets and remove them from vessel.
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 April 2016
Resolution: Corrected while on board. No replacements were necessary as vessel had more than required.
Lifesaving › Lifefloat › Float-free Link
Issued 4 April 2016
Resolved
Connect sea painter to all lifefloats to the vessel via the weak-link.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2016
Resolved 4 April 2016
Resolution: Corrected while on board during inspection.
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 21 May 2012
Resolved
Prove proper operation of the gerneral alarm system prior to carrying passengers for overnight occomidations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2012
Resolved 22 May 2012
Resolution: Proved proper operation of the gerneral alarm system.
Fire Fighting › Fire Pumps › Power Source
Issued 21 May 2012
Resolved
Prove proper operation of the power driven fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2012
Resolved 22 May 2012
Resolution: Proved proper operation of the power driven fire pump.
Stability › Incline Test › General
Issued 23 February 2009
Resolved
Send weight results to MSC and if over the 2% limit a Incline test is reqiuired
Action required: 705 - Other - as specified
Resolved 16 October 2009
Resolution: Requirement carried over to new CG-835 with specific instructions for deadweight survey and incline exam as per MSC.
Stability › Watertight Integrity › General
Issued 5 January 2009
Resolved
Remove ventilation in the lower section of the Collision Bulkhead
Action required: 705 - Other - as specified
Resolved 1 June 2009
Resolution: Ventilation opening removed and bulkhead made watertight. Sector LA-LB verified at 1 JUN 2009 annual inspection.
Fire Fighting › Grease Extraction Hood › General
Issued 5 January 2009
Resolved
Renew galley grease extraction hood and install proper hood, NFPA fan and NFPA 17 wet extinguishing system. Vsl has one year from the 23 Feb. 2009 to comply
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 24 May 2010
Resolution: Vessel installed new galley grease extraction hood.
Stability › Watertight Integrity › General
Issued 5 January 2009
Resolved
Provide weight for all piping/materials removed
Action required: 705 - Other - as specified
Resolved 16 October 2009
Resolution: Requirement carried over to new CG-835 with specific instructions for deadweight survey and incline exam as per MSC.
Fire Fighting › Fire Hoses › Condition
Issued 4 June 2008
Resolved
Provide (2) 50 foot fire hoses IAW 46 CFR 181.320
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Resolution: 02 50 foot fire hoses provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 June 2008
Resolved
Provide machinery guards for p/s MDE's IAW 46 CFR 177.960
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 12 June 2008
Resolution: Machinery guards for both port and starboard MDE''''''''s provided.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 June 2008
Resolved
Provide ventilation covers for engine room ventilation IAW 46 CFR 177.960.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 12 June 2008
Resolution: Ventilation covers provided.
Fire Fighting › Grease Extraction Hood › General
Issued 4 June 2008
Resolved
Remove light fixture and wiring from galley hood exhaust IAW 177.620 (e).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 12 June 2008
Resolution: Light fixture and wiring removed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 4 June 2008
Resolved
Provide covers for electrical outlet and light switch in galley stowage compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 12 June 2008
Resolution: Covers for electrical outlets and light switch provided.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 4 June 2008
Resolved
Provide acceptable means of recovery for a helpless person IAW 46 CFR 180.208.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 12 June 2008
Resolution: Means of recovery for a helpless person provided.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2007
Resolved
Make permanent repairs to wasted plywood hull, starboard side bow/beam.
Due 14 March 2007
Resolved 14 March 2007
Construction/Loadline › Hull › Keel
Issued 27 February 2007
Resolved
Repair fiberglass area approx 1.5' on keel/aft where previous repair is failing.
Due 27 February 2007
Resolved 14 March 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 27 February 2007
Resolved
Re-install or properly cap off watermaker thru hull in laz.
Due 27 February 2007
Resolved 14 March 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 February 2007
Resolved
Repair fwd bulkhead in laz, stbd side near exhaust.
Due 27 February 2007
Resolved 14 March 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 27 February 2007
Resolved
Ensure PVC fresh water pipe bulkhead penetrations meet 46CFR182.40-1 (old-T)
Due 1 April 2007
Resolved 26 March 2007
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 27 February 2007
Resolved
Properly terminate/plug fuel valves were sight glass had been removed.
Due 27 February 2007
Resolved 14 March 2007
Fire Fighting › Grease Extraction Hood › General
Issued 5 April 2006
Resolved
Ensure galley hood fire extinguishing system is properly serviced as per 46 CFR 176.810(5) NLT 05MAY06.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 2 May 2006
Resolution: System was serviced and documented to the satisfaction of the attending Marine Inspector.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 April 2006
Resolved
Provide markings to emergency escape hatches per 436 CFR 185.606 NLT 05MAY06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 2 May 2006
Resolution: The emergency escape hatch in the galley was marked to the satisfaction of the attending Marine inspector.
Lifesaving › Lifefloat › Painter
Issued 5 April 2006
Resolved
Life floats not properly stowed. The lines between the apparatus is not long enough to allow each to float without stacking up. Provide proper stowage per 46 CFR 180.137(e)(3) NLT 05MAY06.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 2 May 2006
Resolution: The life floats were stowed properly to the satisfaction of the attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 June 2005
Resolved
Provide proof of current enrollment in drug & alcohol program (46 CFR 16).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 9 June 2005
Communications › Audible Communications › Horn/Whistle
Issued 2 June 2005
Resolved
Provide operational sound producing devices. Horn inop & bell missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 9 June 2005
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 2 June 2005
Resolved
Properly stow one of inflatable liferafts. Raft was on dock post-servicing, awaiting re-installation. Vessel restricted to 25 passengers on Oceans route until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2005
Resolution: Liferaft found properly stowed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 June 2005
Resolved
Prove proper operation of 2nd (emergency) generator. Vessel restricted to Zone 1 route until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 2 June 2005
Resolved
Prove proper operation of inop smoke detector in berthing accommodation. Vessel restricted from overnight passengers until corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2005
Lifesaving › Lifebuoys › Quantity
Issued 2 June 2005
Resolved
Provide required number of life rings--01 ring missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 June 2005
Resolved
Replace batteries in 01 life-float light with proper type (with expiration dates).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2005
Resolved 9 June 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 June 2005
Resolved
Replace missing/outdated items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2005
Resolved 9 June 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 June 2005
Resolved
Provide proper draft markings IAW 46 CFR 185.602. Correct prior to completion of next credit dry-dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 26 March 2007
Documentation › Markings/Placards › Warning Signs
Issued 8 April 2005
Resolved
Properly mark emergency escape hatches in all bunkrooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 26 April 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 April 2005
Resolved
Ensure all bulkhead penetrations in engine room are properly filled in.
Condition: Unknown
Due 15 April 2005
Resolved 26 April 2005
Stability › Watertight Integrity › General
Issued 8 April 2005
Resolved
Ensure forward bunk room emergency escape hatch is operational.
Condition: Damaged By Earlier Event
Due 15 April 2005
Resolved 26 April 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 8 April 2005
Resolved
Service discharged fire extinguisher.
Condition: Unknown
Due 15 April 2005
Resolved 2 June 2005
Resolution: New extinguisher on-board.
Construction/Loadline › Hull › Side Shell
Issued 8 April 2005
Resolved
Submit repair proposal for all fiberglass work performed on vessel. Starboard side amidships hull had apparent damage in need of repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 12 April 2005
Resolution: Operator plans on removing exposed problem area and cut back to find good wood, repair as needed and reglass. Repair proposal reviewed and approved.
Communications › Radio Communications
Issued 4 June 2004
Resolved
Install a NAVTEX Receiver and provide updated FCC safety radio certificate.
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 4 June 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 June 2004
Resolved
Provide First Aid Kit
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 10 June 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 4 June 2004
Resolved
Provide fire extinguishers (B-I and (6) B-II) and servicing certificate.
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 10 June 2004
Fire Fighting › Miscellaneous Items
Issued 4 June 2004
Resolved
Provide smoke detector systems in accomodation spaces.
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 7 June 2017
Resolution: Provided smoke detector systems.
Accommodation/Occupational Safety
Issued 4 June 2004
Resolved
Label Emergency Exits in accomodation spaces.
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 10 June 2004
Resolution: Labelled emergency exits.
Operations/Management › Drills/Instruction
Issued 4 June 2004
Resolved
Conduct fire and man overboard drills.
Action required: 705 - Other - as specified
Due 9 June 2004
Resolved 10 June 2004
Resolution: Conducted satisfactory drills.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 4 June 2004
Resolved
Provide updated FCC Safety Radio Certificate and provide FCC exemption letter for distress frequency receiver
Action required: 705 - Other - as specified
Due 1 February 2005
Resolved 29 March 2005
Resolution: FCC granted exemption certificate for distress frequency receiver.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 October 2003
Resolved
Remove exhaust system to determine extent of wood damage. Vessel has wet exhaust system in place.
Action required: 705 - Other - as specified
Due 12 May 2004
Resolved 12 May 2004
Resolution: Removed existing exhaust system and replaced it.
Operations/Management
Issued 28 October 2003
Resolved
Submit repair proposal for the wood and electrical damage. Include extent of damage and wiring diagram.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 10 June 2004
Resolution: Submitted repair proposal to [name withheld] 4, 2004, [name withheld] inspected electrical components. All satisfactory.
Operations/Management
Issued 28 October 2003
Resolved
Conduct underway check ride
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 10 June 2004
Resolution: Completed satisfactory check ride during annual inspection.
Operations/Management
Issued 28 October 2003
Resolved
All inspections tests and installations are to be completed to the safisfaction of the OCMI
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 28 October 2003
Operations/Management
Issued 28 October 2003
Resolved
Vessel is restricted from operating until satisfactory completion of all the above items.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 28 October 2003
Electrical › Electric Supply System (service)
Issued 29 May 2003
Resolved
Repair/replace electrical cable leading from main distribution panel to stbd engine in way of port stringer near transmission. Repairs must be carried out in accordance with 46 CFR 183. LEGACY COMPONENT DESC: Cable
Due 13 June 2003
Resolved 29 May 2003
Fire Fighting › Miscellaneous Items
Issued 29 May 2003
Resolved
Replace battery in aft bunkroom smoke detector.
Due 13 June 2003
Resolved 29 May 2003
Fire Fighting › Grease Extraction Hood
Issued 29 May 2003
Resolved
Service fixed fire fighting system for galley hood.
Due 29 June 2003
Resolved 29 May 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 29 May 2003
Resolved
Clean grease from galley hood.
Due 29 June 2003
Resolved 29 May 2003
Fire Fighting › Ventilation Systems
Issued 29 May 2003
Resolved
Install vent closures for engine room vents located main deck, aft of house.
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 29 May 2003
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 May 2003
Resolved
Renew 18 adult PFDs, passenger count reduced to 25, total person reduced to 29.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 29 May 2003
Resolved
Make collision bulkhead watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2003
Resolved 29 May 2003
Electrical › Electric Supply System (service)
Issued 29 May 2003
Resolved
Remove "romex" electrical cable from wheelhouse overhead. Replace with calbe that compies with 46 CFR 183. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 29 June 2003
Resolved 29 May 2003
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Provide spacers between lifefloats.
Due 13 June 2003
Resolved 30 May 2003
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Provide two paddles per lifefloat that comply with regulations. Marked with vessel name and fastened inside lifefloat.
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 30 May 2003
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Mark lifefloats with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 30 May 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 May 2003
Resolved
Mark liferings with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2003
Resolved 30 May 2003
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Lifefloats not stowed properly. Weak link must be secure to vessel and painter attached to lifefloat.
Action required: 705 - Other - as specified
Due 29 June 2003
Resolved 30 May 2003
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Provide waterlight for each lifefloat. Waterlights are to be float free and secured to lifefloats.
Action required: 705 - Other - as specified
Due 29 June 2003
Resolved 30 May 2003
Construction/Loadline › Penetrations
Issued 23 April 2003
Resolved
Provide a sea valve at the through hull penetration for the fish hold refrigeration unit condensor cooling water discharge on the starboard side in the engine-room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2003
Resolved 30 April 2003
Electrical
Issued 27 March 2002
Resolved
Loose electrical wires in engine room space
Due 5 April 2002
Resolved 28 March 2002
Resolution: Loose wires secured in engine room space.
Deck/Cargo
Issued 27 March 2002
Resolved
Forward hatches were not properly secured.
Condition: Improper/Lack of Maintenance
Due 5 April 2002
Resolved 28 March 2002
Resolution: Secured forward hatches with chain.
Electrical
Issued 27 March 2002
Resolved
Openings in distribution panel in engine room space.
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 22 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2002
Resolved
Loose cap on port holding tank
Condition: Improper/Lack of Maintenance
Due 5 April 2002
Resolved 28 March 2002
Resolution: Tightened the cap on port holding tank.
Construction/Loadline › Hull
Issued 27 March 2002
Resolved
Wasted zinc platings on bottom plating LEGACY COMPONENT DESC: Bottom Plating
Due 5 April 2002
Resolved 28 March 2002
Resolution: Replaced zinc platings.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 March 2002
Resolved
Ventilation openings to accomodation space.
Condition: Improper Installation
Due 5 April 2002
Resolved 28 March 2002
Resolution: Plugged both openings in collision bulkhead.
Engineering › Fuel Oil Service System
Issued 27 March 2002
Resolved
Fuel tank gauge not properly installed in accordance with 46CFR182.440(7) LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 22 May 2002
Resolved 22 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 March 2002
Resolved
Piping underneath accomodation space penetrated forepeak. Piping no longer in service.
Due 28 April 2002
Resolved 9 April 2002
Engineering › Electric Propulsion System
Issued 27 March 2002
Resolved
Starboard valve in engine room space not secured.
Condition: Placed in Improper Service
Due 28 April 2002
Resolved 9 April 2002
Communications › Alarms/Indicators
Issued 27 March 2002
Resolved
Lacked high level alarm in forward anchor chain space. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Due 5 April 2002
Resolved 9 April 2002
Engineering
Issued 27 March 2002
Resolved
Vessel not gas tight due to various openings in engine room space.
Condition: Improper/Lack of Maintenance
Due 28 April 2002
Resolved 9 April 2002
Construction/Loadline
Issued 12 April 2001
Resolved
PLUG HOLE IN ENGINEROOM AFT BULKHEAD MID BILGE AREA
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 12 April 2001
Resolved
CAP THROUGH-HULL FITTING INHULL, STARBOARD SIDE ENGINEROOM.
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
INSTALL EPIRB IN A FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 12 April 2001
Resolved
PROPERLY CONNECT BILGE SCREEN TO BILGE FOOT IN AFT BUNROOM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 12 April 2001
Resolved
INSTALL SMOKE DETECTORS IN THE ACCOMODATION SPACES IAW 46 CFR 181.400(E)
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Accommodation/Occupational Safety
Issued 12 April 2001
Resolved
PROPERLY MARK THE FORWARD BUNKROOM EMERGENCY ESCAPE HATCH IAW 46CFR185.606.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 12 April 2001
Resolved
INSTALL A GAGE ON FIREPUMP IAW 46 CFR 181.300(B)
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 12 April 2001
Resolved
INSTALL PROPER SUPPORTS FOR WIRING IN ENGINEROOM.
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
VESSEL IS RESTRICTED TO THE CARRIAGE OF 41 PERSONS ON BOARD UNTIL A RULL COMPLEMENT OF LIFEJACKETS ARE PROVIDED.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 12 April 2001
Resolved
PROVIDE PROOF OF OPERATION OF FIRE PUMP AT NO LESS THAN 60 PSI IAW 46 CFR 181.300.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 12 April 2001
Resolved
COMPLETE INSTALLATION OF CLEATS, RAILINGS AND DECK HAUSER PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
POST AN INFLATABLE SURVIVAL CRAFT PLACARD IAW 46 CFR 185.518.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 12 April 2001
Resolved
CAP PIPE OPENING THROUGH HULL ON PORT SIDE ENGINEROOM
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 12 April 2001
Resolved
PROVIDE PROOF OF CREW TRAINING DRILLS.
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
PROVIDE PROOF OF REGISTRATION OF THE 406 MHZ EPIRB WITH NOAA.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Engineering
Issued 12 April 2001
Resolved
MAKE ENGINE RPM GAGES ON OPERATING STATION CONTROL PANEL OPERABLE.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Electrical
Issued 12 April 2001
Resolved
PROVIDE A SUITABLE GUARD FOR THE BOW LIGHTING FIXTURE IAW 46 CFR 183.410(A)
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Electrical
Issued 12 April 2001
Resolved
MAKE OPERABLE THE EMERGENCY LIGHTING IN THE FORWARD BUNKROOM.
Condition: Unknown
Due 18 April 2001
Resolved 19 April 2001
Engineering
Issued 12 April 2001
Resolved
INSTALL FLAME INPINGEMENT BOWL ON THE FUEL FILTERS IAW 46 CFR 182.455(B)(6)
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Navigation
Issued 12 April 2001
Resolved
PROVIDE THE NAVIGATION PUBLICATION: INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
PROVIDE A THIRD RING LIFE BUOY IAW 46 CFR 180.70
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
INSTALL A 60 FT LENGTH OF LINE ON RING LIFE BUOY.
Condition: Unknown
Due 12 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 April 2001
Resolved
PROVIDE 96 TABLETS OF ASPIRIN IN THE FIRST AID KIT.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Documentation
Issued 18 April 2000
Resolved
RENEW FCC CERTIFICATES ( RADIO STATION, RADIO TELEPHONY AND BRIDGE-BRIDGE)
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 18 April 2000
Resolved
POST OPERATING INSTRUCTIONS FOR FIXED FIR EXTINGUISHING SYSTEMS IN E/R AND GALLEY.
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 18 April 2000
Resolved
PROVE PROPER OPERATION OF BILGE ALARM IN LAZARETTE.
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Engineering
Issued 18 April 2000
Resolved
LABEL INBOARD FUEL SHUT OFF VALVES
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 18 April 2000
Resolved
RAISE CO2 CYLINDER W/ 2" SPACE BETWEEN CYLINDER AND DECKIAW 46 CFR 181.410(C)(6)
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Lifesaving
Issued 18 April 2000
Resolved
CORRECTLY INSTALL WEAK LINK
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 18 April 2000
Resolved
INSTALL AUTOMATIC SHUTDOWN ON BOTH SUPPLY FANS TO E/R IAW 46 CFR 181.410(B)(10) TO ACTIVATE ON CO2 DISCHARGE
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Lifesaving
Issued 18 April 2000
Resolved
PROVIDE EVIDENCE OF LOGGING EMERGENCY DRILLS, TESTS, & TRAINING IAW 46 CFR 185.420, 185.702, 185.520, 185.524 & 185.720-726. LOG FOR 90 DAYS FOR REVIEW.
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Accommodation/Occupational Safety
Issued 18 April 2000
Resolved
REPLACE STBD WINDOW GLASS
Condition: Unknown
Due 2 June 2000
Resolved 21 June 2000
Accommodation/Occupational Safety
Issued 29 March 2000
Resolved
REPLACE GREY WATER OVERBOARD DISCHARGE PVC PIPE SECTION BETWEEN STBD VALVE AND THRU HULL PENETRATION.
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Construction/Loadline
Issued 29 March 2000
Resolved
PROPERLY FASTEN LONGITUDINAL STIFFENER IN PORTSIDE FROEPEAK.
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Construction/Loadline
Issued 29 March 2000
Resolved
REPAIR/REPLACE ROTTEN OVERHEAD BEAMS & STIFFENERS IN LAZARETTE IWO FWD BULKHEAD.
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Construction/Loadline
Issued 29 March 2000
Resolved
MAKE PROPER REPAIRS TO FRACTURE AT STEM
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Construction/Loadline
Issued 29 March 2000
Resolved
MAKE REPAIRS TO MAIN DECK DECK IWO E/R AND LAZARETTE.
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Navigation
Issued 29 March 2000
Resolved
MAKE PERMANENT REPAIRS/REPLACEMENT TO STBD RUDDER
Condition: Unknown
Due 18 April 2000
Resolved 21 June 2000
Fire Fighting
Issued 14 May 1999
Resolved
COMPLETE INSTALLATION OF FIXED FIRE EXTINGUISHING SYSTEM IN ENGINE SPACE.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 14 May 1999
Resolved
COMPLETE INSTALLATION OF GALLEY HOOD FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 14 May 1999
Resolved
COMPLETE INSTALLATION OF FIRE DETECTION SYSTEM FOR ENGINE SPACE.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Electrical
Issued 22 April 1997
Resolved
Provide and install suitable trays for and secure batteries under steering console in accordance with 46 CFR 183.350(e)
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Navigation
Issued 22 April 1997
Resolved
Re-mount anchor and masthead light to comply with nav rules. (72 COLREGS, rule 22)
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 25 April 1996
Resolved
Make permanent repairs to rails on vessel's upper and lower deck per proposal provided 25APR96 prior to 31MAY96. No passengers may be carried onthe upper deck prior to making installation. All work shall be to the satisifaction of the attending Marine Inspector.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 17 May 1994
Resolved
REPAIR SEAL ON ESCAPE HATCH FROM FORWARD CABIN.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 17 May 1994
Resolved
ATTACH FUEL TANKS IN LAZARAT TO COMMON BONDING STRAP.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 17 May 1994
Resolved
OPEN SPLICES IN WIRING THROUGHOUT VESSEL TO BE PLACED IN JUNCTION BOXES.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 17 May 1994
Resolved
RANGE LIGHT BULBS NEED COVERS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994
Resolved
UPDATE CHARTS 46 CFR 185.20-35.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994
Resolved
UPDATE LIGHT LIST 46 CFR 185.20-35.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
REPLACE FUEL TANK VENT HOSES IN LAZARAT WITH PERMANENT PIPING.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Lifesaving
Issued 17 May 1994
Resolved
RENEW PENDANTS ON LIFEFLOAT 46 CFR 160.010-3. ATTACH OARS TO SIDES OF LIFEFLOAT 46 CFR 180.15-10. LIFEFLOAT SHALL BE REMOVED FROM VESSEL UNTIL IN SERVICEABLE CONDITION.
Condition: Unknown
Due 31 July 1994
Resolved 18 May 1994
Lifesaving
Issued 17 May 1994
Resolved
3 MORE HAND RED FLARES REQUIRED 46 CFR 180.35-5.
Condition: Unknown
Due 31 July 1994
Resolved 18 May 1994
Electrical
Issued 17 May 1994
Resolved
EXPOSED BULB / BAD WIRING IN PANTRY FORWARD OF GALLEY TO BE REPAIRED, AND BROUGHT UP TO STANDARD.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
EXTEND EXHAUST DUCT TO BOTTOM OF COMPARTMENT IN ENGINEROOM_x001C_ 46 CFR 132.20-45.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994
Resolved
STERNLIGHT NEEDS TO BE SECURELY MOUNTED. STERNLIGHT WIRING TO BE REPLACED WITH APPROVED WIRING.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Construction/Loadline
Issued 14 April 1994
Resolved
GRIND BACK GLASS ON KEELSON, JUST UNDER KEEL COOLER, JUST FORWARD OF KEEL COOLER, AND APPROXIMATELY 24" AFT OF BEGINNING OF KEELSON. GRIND BACK GLASS AT CHINE, APPROXIMATELY 18" AFT OF MSD OVERBOARD DISCHARGE OPENING. MAKE ALL AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 14 April 1994
Resolved 18 April 1994
Unknown
Issued 19 April 1991
Resolved
MOVE THE GASOLINE STORAGE RACKS TO THE STERN OF THE VESSEL, MODIFYING THE RACKS FOR A MAXIMUM STORAGE OF 10 CANS.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 14 December 1990
Resolved
PROVIDE NAME AND ADDRESS OF NEW OWNER AND OPERATOR.
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Documentation
Issued 14 December 1990
Resolved
PROVIDE DOCUMENT WITH NAME OF NEW OWNER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Documentation
Issued 14 December 1990
Resolved
POST CERTIFICATE OF INSPECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Electrical
Issued 14 December 1990
Resolved
ON ALL ELECTRIC BILGE PUMPS THROUGHOUT, REPLACE WIRING TO GOOD MARINE _x001C_ PRACTICE, HOOK UP HOSES, ETC._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Electrical
Issued 14 December 1990
Resolved
PUT COMMECTION IN HEATER WIRING IN CABIN B IN A JUNCTION BOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Electrical
Issued 14 December 1990
Resolved
IN FOOD STORAGE AREA, REMOVE OR CORRECT WIRING JUNCTION FOR LOUDHAILER_x001C_ SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Electrical
Issued 14 December 1990
Resolved
REPLACE BILGE SUCTION AND SCREEN IN FORWARD COMPARTMENT UNDER AFT STATEROOMS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Electrical
Issued 14 December 1990
Resolved
IN STARBOARD HEAD, PUT BLOWER CONNECTION IN JUNCTION BOX._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Unknown
Issued 14 December 1990
Resolved
ON EMERGENCY FUEL SHUTOFFS IN ENGINE ROOM; MAKE TWO CENTER REACH RODS AS ONE PIECE; TIGHTEN BOLTS ON TWO OUTBOARD HANDLES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1990
Resolved 14 December 1990
Documentation
Issued 6 May 1990
Resolved
PROVIDE AND POST THE FCC SAFETY RADIOTELEPHONY CERTIFICATE PRIOR TO THE CARRIAGE OF MORE THAN 6 PASSENGERS.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Electrical
Issued 18 November 1989
Resolved
REMOVE OR PROPERLY TERMINATE ALL DEAD ENDWIRING IN THE ENGINE ROOM. COMPLETE PRIOR TO 18DEC89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Accommodation/Occupational Safety
Issued 18 November 1989
Resolved
PROPERLY MARK ALL EMERGENCY ESCAPE HATCHES ON BOTH SIDES, "EMERGENCY EXIT, KEEP CLEAR", PER 46 CFR 185.30-15, COMPLETE PRIOR TO 18DEC89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Navigation
Issued 18 November 1989
Resolved
PROVIDE 200 MM SHIPS BILL PER NAV RULES ANNEX III. COMPLETE PRIOR TO 18DEC89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Electrical
Issued 18 November 1989
Resolved
REMOVE ALL INSERVICE EXTENSION CORDS FROM THE ENGINE ROOM. COMPLETE PRIOR TO 25NOV89, OR GETTING UNDERWAY.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Electrical
Issued 18 November 1989
Resolved
RECONNECT ALL LOOSE/MISSING ELECTRICAL BONDING STRAPS IN THE ENGINE ROOM. COMPLETE PRIOR TO 18 DEC 89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Fire Fighting
Issued 18 November 1989
Resolved
PROPERTY ALIGN FIRE MAIN DECK STATION OUTLETS, CURRENT ARRANGEMENT HAS HOSEDISCHARGING VERTICALLY, COMPLETE PRIOR TO 18DEC89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Accommodation/Occupational Safety
Issued 18 November 1989
Resolved
REPLACE FLEXIBLE HOUSE ON THE FIRE PUMP DISCHARGE PIPING WITH SAME MATERIALOR RIGID PIPING WITH SUITABLE FITTINGS COMPLETE PRIOR TO 18DEC89.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Construction/Loadline
Issued 12 September 1989
Resolved
SUBMIT PROPOSAL FOR INSTALLATION OF SLIDING PLEXIGLASS DOORS TO ENCLOSED DECK AT AFT SECTION OF VESSEL. UNTIL DOORS ARE APPROVED AND PROPERLY INSTALLED, DOORS ARE TO BE LOCKED IN AN OPEN POSITION WHILE PASSENGERS ARE ON VESSEL.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
COMPLETE INSTALLATION AND DEMONSTRATE PROPER OPERATION OF GENERATOR AND ELECTRICAL POWER PANEL GAGES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Unknown
Issued 26 May 1988
Resolved
INSTALL 30 X 30 MESH FLAME SCREEN FOR ALL FUEL TANK VENTS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 26 May 1988
Resolved
PROVE WHERE THE SOLID BALLAST IS LOCATED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 26 May 1988
Resolved
PROVIDE AT LEAST 42" HIGH RAILS AROUND PERIMETER OF VESSEL WITH A MAXIMUM DISTANCE BETWEEN COURSES OF 12 INCHES.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 26 May 1988
Resolved
PROVE THAT THE ENCLOSED SPACE ON THE FANTAIL WAS INCLUDED IN THE STABILITY CALCULATIONS. IN THE INTERIM, NO TARP, CANVAS OR CLEAR VINYL MAY BE IN- STALLED AROUND THE FANTAIL.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Engineering
Issued 28 May 1987
Resolved
INSTALL METAL BOWL PROTECTORS ON RACOR FILTERS FOR MAIN ENGINES AND GENERATORS
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Electrical
Issued 28 May 1987
Resolved
INSTALL BLANDS IN BREAKER OPENINGS IN BREAKER BOX ON AFT ENGINE ROOM BULKHEAD
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Documentation
Issued 28 May 1987
Resolved
HAVE THE VESSELS CERTIFICATE OF DOCUMENTATION AMENDED TO SHOW THE OWNERS CURRENT ADDRESS
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987
Resolved
PROVIDE LIGHTS FOR 16 ADULT AND 5 CHILDRENS LIFE PRESERVERS. IN THE INTERIM NOT MORE THAN 50 ADULTS AND 2 CHILDREN MAY BE CARRIED.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987