MAURY USCG vessel records
← All vessels

REDONDO SPECIAL

Built
1956
Last inspected
29 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WUR3778
Flag
UNITED STATES
Maury page id
psix-43187

Documentation record

Registered dimensions (L × B × D)64.0 ft × 18.3 ft × 2.0 ft
Registered tonnagegross 29 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1956
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portREDONDO BEACH, CA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

29 April 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8089562
18 February 2025 Internal Structural Exam · Examination of Repairs · Vessel Attendance · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077694
24 July 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7966134
30 April 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7874018
15 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7681287
24 April 2023 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7674617
22 February 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7605844
23 June 2022 Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485421
22 February 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385651
8 March 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148423
25 January 2021 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7130659
5 November 2020 Appeal · Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7134663
8 June 2020 Deficiency Check · Appeal · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6966364
24 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6636196
26 February 2019 Hull Examination · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618770
26 February 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6362220
27 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6083414
25 January 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6058983
15 July 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6039153
29 May 2016 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5892573
29 May 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5893245
4 March 2016 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5793030

Deficiency record · 28

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 June 2023 Resolved
Each survival craft must be secured to vessel by a painter with a float free link permanently attached to vessel. MI observed weak link missing tag.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 15 June 2023
Resolution: MI received evidence that weak link was replaced and now has proper tag.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2023 Resolved
As appropriate for intended voyages, a vessel must carry up-to-date: charts, coast pilot, light list. MI observed expired references.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 22 June 2023
Resolution: Owner provided proof of up-to-date references.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2021 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel is over due for their Certificate of Inspection, vessel to have approved COI prior to the carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2021
Resolved 18 March 2021
Resolution: Completed COI inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2020 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with §181.425. Vessel must install an approved grease extraction hood and chemical fire extinguishing system. Plans for the system install must be approved and may be submitted to [email withheld]. 46 CFR 181.405
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 24 July 2024
Resolution: Vsl Installed approved system
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 July 2020 Resolved
The following spaces must be equipped with a fire detection and alarm system IAW 46 CFR 76: (b) all griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 46CFR181.425. Galley space found to be missing required fire supression system and grease extraction hood. Provide plan for installtion or request for consideration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 29 September 2020
Resolution: Veseel Owner routed request for consideration with alternate compliance recommendation. Request routed through command.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 June 2020 Resolved
FCC safety radiotelephony certificate is expired. Provide valid certificate or proper documentation from FCC for extension due to COVID-19. (47 CFR 80.401)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 29 September 2020
Resolution: Received copy of valid certificate from vessel owner; all satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2020 Resolved
Alcohol testing strips are expired. Provide valid alcohol testing strips IAW drug and alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 4 August 2020
Resolution: Recieved photographic documentation of the provided alcohol test swabs. Deficiency rectified satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 June 2020 Resolved
Light list no longer valid. Provide updated Light List.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 13 July 2020
Resolution: Vessel master provided updated copy.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 June 2020 Resolved
Coast Pilot is no longer valid. provide updated Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 13 July 2020
Resolution: Vessel Master provided updated copy.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 June 2020 Resolved
Abandon ship drills shall be conducted and logged once every three months. Provide log of conducted abandon ship drills.
Action required: 10 - Deficiency Rectified
Due 22 June 2020
Resolved 22 June 2020
Resolution: Conducted an abandonship drill as part of the annual inspection and v/o logged it in the vessel log to meet requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 June 2020 Resolved
All escape hatches and emergency exits shall be marked on both sides. Provide required marking for galley emergency exit inside the wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 13 July 2020
Resolution: Vessel master satisfactorily labeled emergency exit in the wheel house.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 June 2020 Resolved
Distress signal container shall be clearly marked "DISTRESS SIGNALS". Provide required container with required marking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 13 July 2020
Resolution: Provided properly labeled container.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 June 2020 Resolved
Placards containing instructions for donning and use of the life jackets on board must be posted in conspicuous place. Provide life jacket placard for all types of life jackets carried on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 21 July 2020
Resolution: V/O Emailed satisfactory photograph of the rectified def. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 February 2018 Resolved
Provide 7 additional adult and 1 child lifejackets. Vessel is restricted to 57 total persons on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 March 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2018 Resolved
Replace burnt-out stern light - make operational. Vessel restricted to daylight/high-visibility operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 March 2018
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 27 February 2017 Resolved
The Master was not enrolled in the DAPI program nor did he conduct pre-enrollment training
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 28 February 2017
Resolution: Master performed the pre-employment drug test and was enrolled in the DAPI program
Engineering › Steering Gear System › Hydraulic Hose
Issued 27 February 2017 Resolved
Steering malfunction caused by a hydraulic hose bursting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Vessel repaired hydraulic hose
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 February 2017 Resolved
Found seven adult lifejackets unserviceable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Updated CG-835 based on durernt number of lifejackets at 2018 annual.
Fire Fighting › Fire Pumps › Pressure
Issued 27 February 2017 Resolved
Tested fire pump while underway and pump was only able to produce 20 PSI
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 26 February 2018
Engineering › Fuel Oil Service System › Piping
Issued 29 May 2016 Resolved
Vessel experienced a loss of propulsion due to fuel pipeline related issues, vessel may not carry passengers until cleared by a Coast Guard Marine Inspector and a satisfactory underway sea trial.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Resolution: Vessel bled air from fuel lines, allowing main engine to satisfactory operate. No sail cleared.
Lifesaving › Lifebuoys › Immediately Available
Issued 4 March 2016 Resolved
Attach corrosion resistanct clip on water light life ring lanyard, iaw 46 CFR 180.70.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 13 April 2016
Resolution: Clip is installed
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 March 2016 Resolved
Prove bouyant apparatus line is U.V. resistant, iaw 46 CFR 137.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 13 April 2016
Resolution: Line is renewed
Engineering › Steering Gear System › Rudder
Issued 4 March 2016 Resolved
Repair rudder arm in way of hydraulic ram attachment, 46 CFR 176.05-35
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 13 April 2016
Resolution: Sttering tiller is renewed.
Documentation › Certificates/Documents › Stability Letter
Issued 4 March 2016 Resolved
Post Stability letter, iaw 46 CFR 176.306.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 13 April 2016
Resolution: Stability letter posted.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 4 March 2016 Resolved
Provide FCC operator permit, iaw 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 3 June 2016
Resolution: Verified operator had FCC license
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 March 2016 Resolved
Replace 03 missing/unsevicable adult life jakets, iaw 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 13 April 2016
Resolution: Life jackets have been renewed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 March 2016 Resolved
Renew retro reflective tape on 06 adult and 02 child PFD's as specified, iaw 46 CFR 164.019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 13 April 2016
Resolution: Retro has been renewed
Engineering › Bilge Water Management System › Not Operational
Issued 4 March 2016 Resolved
Fix bilge suction in salon. Demonstrate proper operation, iaw 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 7 March 2016
Resolution: bilge suction satisfactory demonstrated.

Ownership record