NRC DEFENDER is a 1958 oil recovery. The Coast Guard has recorded 15 inspections since 2016, most recently in February 2026, along with 9 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2026. Most recent: inspection, 4 February 2026.

Built
1958
Last inspected
4 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCB9039
Flag
UNITED STATES
Maury page id
psix-43614

Documentation record

Registered dimensions (L × B × D)198.0 ft × 46.0 ft × 12.5 ft
Registered tonnagegross 942 / net 942
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG B ZIGLER CO · MERMENTAU, LA, UNITED STATES · built 1958
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 April 2026 · expires 28 February 2027
Service, as the file records itOil Recovery
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it942 - Regulatory (Subpart C or D), Gross Ton
942 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

4 February 2026 Cargo Tank Internal · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8300783
19 November 2025 COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8259953
4 November 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8029167
2 February 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7861409
2 November 2023 Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7819476
15 November 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7594717
18 October 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7335678
14 January 2021 Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125146
16 November 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7096722
4 November 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6849146
16 January 2019 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611199
22 October 2018 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6566096
15 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6297390
28 October 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6031422
8 January 2016 Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5794084

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2025 Resolved
All tanks not vented to atmosphere must be constructed and tested in accordance with part 54 of this subchapter. Generator fuel tank had missing fuel vent. 46 CFR 31.30-1 46 CFR 58.50-10(c)(3)
Action required: 705 - Other - as specified
Resolved 16 March 2026
Resolution: Fuel tank replaced with proper venting.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 19 November 2025 Resolved
The pressure vacuum relief valve shall be of a type and size approved by the Commandant for the purpose Intended. The tank flame screens on 1P, 2S, 3P, and 5P were not in serviceable condition. 46 CFR 32.20-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 December 2025
Resolution: Identified tanks had new flame screens satisfactorily installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 November 2025 Resolved
An offshore oil barge with a cargo capacity of 250 or more barrels must have – a mechanical means of closing each drain and scupper within the coaming. Scupper plugs were missing throughout the barge’s containment openings. 33 CFR 155.310(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 December 2025
Resolution: New mechanically fastened plugs for containment installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 November 2025 Resolved
When the vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the vessel sinks. 46 CFR 31.36-1 46 CFR 199.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2025
Resolution: New hydrostatic release properly installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 November 2025 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Barges EPIRB registration reflects incorrect 12 man capacity, correct to 16. 46 CFR 31.36-1 46 CFR 199.510 46 CFR 80.1061(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2025
Resolution: New EPIRB registrated updated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2019 Resolved
Vessel stern light was battery operated. Battery located in hazardous location, vessel representative removed battery.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 November 2019
Resolution: Battery was removed during the inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 October 2018 Resolved
Remote manual pull stop for prime mover cargo pump inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: cable maintenance performed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 October 2018 Resolved
Flame screens for ullage opening holed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 October 2018 Resolved
Openings in handrails cannot be secured when not in use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2018
Resolution: Vessel rep. installed shackles to secure hand rail chains.

Casualty record · 1

11 November 2005Major Marine Casualty · role: Cargo Recipient · serious marine incident, as classified · activity 2542007
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.