Inspection history · 104
22 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4053299
22 August 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2756514
12 November 2005
Administrative Inspection · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2533129
11 November 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2542007
11 October 2005
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2519142
18 April 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2337179
28 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2349821
14 December 2004
MTSA/ISPS Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2408926
23 November 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2247125
19 April 2004
Internal Structural Exam · Periodic Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2043873
2 March 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2016569
29 January 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1996764
12 November 2003
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1949934
7 October 2003
Examination of Repairs · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1923413
22 September 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1909964
22 August 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1665111
21 February 2002
Internal Structural Exam · Hull Examination · COI Inspection · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488103
25 September 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074813
18 September 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458927
21 June 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077216
15 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 94400
5 January 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056804
14 December 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059264
22 November 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 824580
17 October 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459639
3 August 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 821477
29 June 2000
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 819918
24 June 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 464303
23 May 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406724
27 April 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 817350
17 April 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 277035
17 February 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461246
27 September 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406569
24 August 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115051
10 August 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 777002
14 April 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 467407
12 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1369022
29 January 1999
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1365018
10 September 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1457678
31 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 529524
18 March 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 462739
22 January 1998
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 412083
14 January 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 733338
10 January 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 500214
30 September 1997
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122107
11 July 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1113967
2 June 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1108840
10 April 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421295
30 December 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 475950
6 September 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 452089
4 June 1996
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1359149
27 May 1996
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1360528
20 April 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080206
8 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 471257
8 April 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404132
31 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 19135
14 March 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463221
20 December 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1181164
1 May 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 499891
15 April 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861213
27 March 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141420
27 March 1995
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1424071
22 March 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 825617
20 March 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868417
8 January 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 450385
16 March 1994
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855463
3 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 449557
23 December 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159470
29 November 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158712
4 November 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152697
15 July 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 493002
10 June 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 495507
20 April 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 452630
12 February 1993
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1144328
2 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 517717
22 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251071
13 August 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957495
29 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399770
28 March 1992
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268125
9 March 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1270977
18 January 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902510
9 June 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227624
5 June 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 900929
4 June 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236853
6 May 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 441939
2 February 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903650
23 October 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203689
22 March 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965763
17 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895040
20 January 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891158
11 April 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1034882
26 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329134
17 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324674
4 February 1987
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1006933
9 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295577
14 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000141
20 August 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989512
29 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290070
15 June 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 982133
12 June 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526338
21 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983706
5 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985915
27 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972833
1 February 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271891
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 18 April 2005
Resolved
Test cargo pump relief valves. Ensure proper operation.
Due 27 May 2005
Resolved 13 May 2005
Construction/Loadline › Markings › Load Line Mark
Issued 18 April 2005
Resolved
Repaint loadline marking in contrasting color to hull.
Due 27 May 2005
Resolved 28 April 2005
Resolution: Loadline repainted white.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 18 April 2005
Resolved
Stencile "OIL SERVICE" on cargo transfer hoses.
Due 27 May 2005
Resolved 18 April 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 April 2005
Resolved
Cover or blank off openings in electrical panelboard in generator house.
Due 27 May 2005
Resolved 28 April 2005
Resolution: All openings blanked off.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2005
Resolved
Replace missing light and light covers in overhead light fixtures in generator house. One missing light and cover by switchboard, one broken light cover at inboard doorway.
Due 27 May 2005
Resolved 30 April 2005
Resolution: Light over switchboard removed from service.
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2005
Resolved
Clean dirty generator windings. (Very oily)
Due 27 May 2005
Resolved 30 April 2005
Resolution: Windings cleaned.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 18 April 2005
Resolved
Replace overfill alarm light (red) on stbd. machinery house, inboard side.
Due 27 May 2005
Resolved 28 April 2005
Resolution: Red overfill light installed and proper operation demonstrated.
Engineering › Fuel Oil Service System › Valve
Issued 18 April 2005
Resolved
Stencile "EMERGENCY FUEL SHUTOFF" on remote shutdown pulls.
Due 27 May 2005
Resolved 28 April 2005
Resolution: Both shutdown pulls stenciled in black letters.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 April 2005
Resolved
Calibrate or replace air receiver gauges (3).
Due 27 May 2005
Resolved 28 April 2005
Resolution: Gauges renewed.
Stability › Weathertight Integrity › General
Issued 18 April 2005
Resolved
Provide weathertight seal on machinery house air vents and dampers by next drydock (Apr 2007).
Due 30 April 2007
Resolved 22 June 2011
Resolution: This activity was opened during data call while doing some housekeeping in MISLE. This vessel has been out of all open deficiencies have been removed //s// [name withheld], Sector New York, Civilian Marine Inspector, Ralph.e.savercool@uscg [phone withheld]
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 April 2005
Resolved
Provide legible Halon instructions on both machinery houses IVO Halon actuator controls.
Due 27 May 2005
Resolved 3 May 2005
Resolution: Instruction signs ordered; proof of purchase sent to MSO.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 18 April 2005
Resolved
Stencile "VAPOR" on VCS manifold terminals as required by 46 CFR 39.
Due 27 May 2005
Resolved 30 April 2005
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 18 April 2005
Resolved
Remove oil from deck underneath bow thruster engine.
Due 27 May 2005
Resolved 28 April 2005
Resolution: Oil removed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 April 2005
Resolved
Provide covers on two (2) junction boxes mounted on outboard side of bow thruster engine.
Due 27 May 2005
Resolved 30 April 2005
Resolution: Junction boxes installed satisfactorily.
Deck/Cargo › Vapor Control Systems
Issued 19 April 2004
Resolved
Replace Stud on starboard side VCS flange and paint spool piece IRT to 46 CFR 39-20.
Due 21 May 2004
Resolved 23 April 2004
Construction/Loadline › Structures
Issued 19 April 2004
Resolved
Insert plate IWO of fractures on #2 P/S and #5 Cargo tank as marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2004
Resolution: Insert was vaccum tested by ABS surveyor
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 April 2004
Resolved
Replace wastage longitudinals and stiffeners in #1 DB tank IWO last bay aft.
Due 21 February 2005
Resolved 3 January 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 April 2004
Resolved
Replace wastage longitudinals in #2 and #5 P/S DB tank as needed.
Due 21 February 2005
Resolved 3 January 2005
Resolution: Replaced wasted cargo tank under deck longitudinals in the double bottoms.
Electrical › Electrical Distribution System (service)
Issued 21 February 2002
Resolved
Various missing circuit breakers. Install blanks or install breakers. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 9 May 2002
Resolved 29 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 21 February 2002
Resolved
Missing vapor rtecovery approval letter. Vessel is working on getting a copy of letter. Letter# is on the COI LEGACY COMPONENT DESC: Cargo Monitor/Control System
Condition: Unknown
Due 10 June 2002
Resolved 22 August 2002
Resolution: Physical copy of letter not required due to MSC approval letter listed on COI.
Fire Fighting
Issued 18 September 2001
Resolved
PROVIDE COPY OF SERVICING REPORT ON ALL FIRE EXTINGUISHERS NO LATER THAN 25SEP01.
Condition: Unknown
Due 25 September 2001
Resolved 26 September 2001
Fire Fighting
Issued 18 September 2001
Resolved
REPLACE DISCHARGE HOSE ON BOTH HALON BOTTLES NO LATER THAN 25SEP01.
Condition: Unknown
Due 25 September 2001
Resolved 26 September 2001
Deck/Cargo
Issued 17 October 2000
Resolved
MAKE REPAIRS TO BOTH THERMAL FLUID HEATERS FLAME FAILURE AUDIO/VISUAL ALARMS, PRIOR TO PLACING THEM BACK TO OPERATIONAL STATUS.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Electrical
Issued 17 October 2000
Resolved
MAKE REPAIRS TO INBOARD GENERATOR.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Construction/Loadline
Issued 29 June 2000
Resolved
Prior to departure, make permanent repairs to Number 5 Port Wing Void in way of Frame 43 between second and third horizontal side shell frames, cropand renew side shell approx. 2'x 4' and swash bulkhead 2'x4'; complete to the satisfaction of the local OCMI or Class Surveyer and provide report.
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000
Lifesaving
Issued 29 January 1999
Resolved
CLEAN AND GASS FREE #4 PORT CARGO TANK AND #4 PORT WING BALLAST TANK FOR FURTHER INSPECTION.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Lifesaving
Issued 29 January 1999
Resolved
CLEAN AND GAS-FREE #5 PORT CARGO TANK AND #5 PORT WING BALLAST TANK FOR FURTHER INSPECTION.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Documentation
Issued 29 January 1999
Resolved
SUBMIT WRITTEN EXPLANATION TO EXPLAIN WHETHER ANY REPAIRS CONDUCTED WERE DUE TO CLASS STRUCTURAL FAILURES.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Construction/Loadline
Issued 29 January 1999
Resolved
CROP AND RENEW APPROXIMATELY 24" X 24" #5 PORT CARGO TANK BULKHEAD PLATING IWO #6 CARGO TANK LONGITUDINAL FRAM IWO FORWARD SWASH BULKHEAD IN BAY #6 OF#5 PORT WING BALLAST TANK.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Construction/Loadline
Issued 29 January 1999
Resolved
CROP AND RENEW APPROXIMATELY 18" X 7'6" #5 PORT CARGO TANK BULKHEAD PLATINGIWO #1 AND #4 CARGO TANK LONGITUDINAL FRAMES AND THE AFT BULKHEAD. CONDUCT DYE PENETRANT TEST OF AFT BULKHEAD IWO REPAIR TO PROVE INTEGRITY BETWEEN #5P C/T AND COFFERDAM PRIOR TO FITUP OF INSERT.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Deck/Cargo
Issued 29 January 1999
Resolved
LOCATE LEAK BETWEEN #4 PORT CARGO TANK & #4 PORT WING BALLAST TANK. MAINTAIN VALVE TO SEG. BALLAST PIPING IN A CLOSED CONDITION, LOCK & TAG OUTUNTIL REPAIRS ARE EFFECTED. MONITOR TANK & REPORT AT EACH LOADING/DISCHARGEPORT UNTIL LEAK IS LOCATED AND REPAIRS EFFECTED.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Construction/Loadline
Issued 29 January 1999
Resolved
REPAIR LEAK IWO #4 PORT CARGO EXPANSION TANK AND DECK PLATING WHERE HOLED.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Documentation
Issued 29 January 1999
Resolved
PROVE IN WRITING THE INTEGRITY OF SEGREGATED BALLAST SYSTEM PRIOR TO CONDUCTING BALLAST OPERATIONS INVOLVING #4 AND #5 PORT WING BALLAST TANKS.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Construction/Loadline
Issued 4 June 1996
Resolved
IN AFT PORT COFFERDAM, MAKE AND MAINTAIN A TEMPORARY CONCRETE BOX PATCH IN WAY OF 1" U-SHAPE FRACTURE AT RAT HOLE IN FORWARD END OF THE FIRST LONGITUDINAL OUTBOARD OF NOTCH IN BOTTOM PLATE. PERMANENT REPAIRS TO BE COMPLETED AT NEXT DRY DOCK.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Construction/Loadline
Issued 4 June 1996
Resolved
UNTIL PERMANENT REPAIRS TO THE FRACTURE IN THE PORT COFFERDAM ARE COMPLETEDTO THE SATISFACTION OF THE COGNIZANT OCMI, THE AFT PORT COFFERDAM SHALL BE VISUALLY EXAMINED FROM THE DECK DAILY AND THE CONDITION LOGGED IN THE VESSEL LOG. ANY FLOODING SHALL BE REPORTED THE THE COGNIZANT OCMI.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Engineering
Issued 8 April 1996
Resolved
REBRICK AN REPAIR REFRACTORY IN COMBUSTION CHAMBER AND ON THE BURNER ASSEMBLY IN PORT THERMAL FLUID HEATER PRIOR TO OPERATION OF SUBJECT MACHINERY.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Engineering
Issued 14 March 1996
Resolved
THERMAL FLUID HEATER INTERNALS TO BE VISUALY INSPECTED.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996
Resolved
TEST OVER-SPEED SHUT DOWN OF BOTH MAIN GENERATOR ENGINES IN THE PRESENSE OFA C.G. MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1996
Resolved 12 April 1996
Accommodation/Occupational Safety
Issued 14 March 1996
Resolved
MAKE REPAIRS OR REPLACE: RAILS AT TOP OF AFT PORT LADDER, AFT STDB CATWALKOVER DECK PIPING, AND LADDERS BETWEEN MACHINERY HOUSES UP TO CARGO MNFLD, FWD STBD SIDE OF CARGO MNFLD, FROM CARGO MNFLD TO TOP OF BOILER HOUSE, ON AFT PORT SIDE OF CARGO MNFLD, AND TO PORT BOILER HOUSE ENTRANCE.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996
Resolved
INSTALL INSULATION OR GUARD AROUND EXPOSED EXHAUST PIPING FROM MANIFOLDS ONINBOARD MAIN DIESEL GENERATOR.
Condition: Unknown
Due 15 April 1996
Resolved 25 March 1996
Construction/Loadline
Issued 14 March 1996
Resolved
DISPLAY VESSEL'S NAME AT THE TOP OF MACHINERY HOUSES. _x001C_ _x001C_ 46 C.F.R. 32.05-15
Condition: Unknown
Due 15 April 1996
Resolved 12 April 1996
Engineering
Issued 14 March 1996
Resolved
CONDUCT AN OPERATIONAL TEST OF AUTOMATION AND SAFETIES FOR BOTH THERMAL FLUID HEATERS IN THE PRESENSE OF A C.G. MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1996
Resolved 25 March 1996
Construction/Loadline
Issued 20 December 1995
Resolved
MAKE TEMPORARY REPAIR TO 6" CRACK IN AFT PORT VOID. AIR TEST TO BE WITNESSED BY USCG INSPECTOR.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 20 December 1995
Resolved
MAKE PERMANENT REPAIR TO 6" CRACK IN AFT PORT VOID LOCATED IWO INBOARD SEAMOF NOTCH AND BOTTOM PLATING, NO LATER THAN THE NEXT DRYDOCK.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Engineering
Issued 27 March 1995
Resolved
Re-install missing insulation for bow thruster engine exhaust manifolds.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 27 March 1995
Resolved
Make repairs to holed thermal fluild heater head tank return line. Heater is not to be used until repairs completed.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 27 March 1995
Resolved
Repair holed exhaust pipe inboard stbd cargo pipe engine and repair holed exhaust muffler on outboard cargo pump engine stbd house.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Documentation
Issued 27 March 1995
Resolved
Provide addendum No 2 to loading manual bearing USCG approval stamp dated 27FEB95 as per Stability letter dated 27FEB95.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Electrical
Issued 27 March 1995
Resolved
Replace burnt electric wiring on inboard thermal fluild heater in way of thermal temp probe. Heater not to be operated until repaired.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 27 March 1995
Resolved
Replace holed bow thruster muffler.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Documentation
Issued 29 May 1992
Resolved
PROVIDE MARINE SAFETY OFFICE NEW ORLEANS WITH MARINE SAFETY CENTER APPOVAL LETTER AND PLAN REVISIONS SUBMITTED 06MAY92 FOR INSTALLATION OF VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Engineering
Issued 28 March 1992
Resolved
Disconnect electrical connection and fuel oil piping to thermal fluid heaters. heaters may not be operated until safety devices are installed.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Deck/Cargo
Issued 4 June 1990
Resolved
DISCHARGE PRESSURE LIMITED TO 50 PSI UNTIL PERMANENT REPAIRS COMPLETED. A MINIMUM OF A TANKERMAN AND AN ABLE SEAMAN TO MONITOR DISCHARGE OF CARGO AT ALL TIMES.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Deck/Cargo
Issued 4 June 1990
Resolved
EFFECT PERMANENT REPAIRS AND HYDROSTATICALLY TEST LOADING MANIFOLD TO THE SATIFACTION OF THE COGIZANT OCMI.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Deck/Cargo
Issued 4 June 1990
Resolved
ISOLATE STBD FWD LOADING MANIFOLD AND FINISH CLEAN UP OF RESIDUAL OIL ON DECK PRIOR TO DEPARTURE. LOADING OF ADDITIONAL CARGO PROHIBITED UNTIL PERMANENT REPAIRS COMPLETED.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Deck/Cargo
Issued 4 June 1990
Resolved
ISOLATE ALL BROKEN GAUGE FITTINGS AND BLOWOUT LINES WITH PIPE PLUGS ON STBDFORWARD MANIFOLD PRIOR TO DISCHARGE OF CARGO IN HOUSTON. CONTACT MSO HOUSTON FOR A DISCHARGE MONITOR PRIOR TO OFFLOADING.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Navigation
Issued 20 January 1989
Resolved
PAINT NAVIGATION RUNNING LIGHTS SCREENS FLAT BLACK. 33 CFR84.09
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Engineering
Issued 20 January 1989
Resolved
RELOCATE REMOTE SHUT-OFF TO ACTUATE VALVE CLOSEST TO FUEL OIL DAY TANK IN BOW THRUSTER ROOM. 46 CFR 56.50-75.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Electrical
Issued 20 January 1989
Resolved
PROVIDE BLANK COVERS FOR OPEN BREAKER SPACES IN LOWER PANEL BOX ON MAIN SWITCHBOARD. 46 CFR 11.30-5.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Electrical
Issued 20 January 1989
Resolved
REPAIR OR REPLACE SYNCHROSCOPE ON MAIN SWITCHBOARD. 46 CFR 111.30-25(D)(3)
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Engineering
Issued 4 February 1987
Resolved
PROVE OPERATION OF ALL SAFETY, LIMIT AND COMBUSTION CONTROLS ON BOTH THERMAL FLUID HEATERS PRIOR TO PUTTING INTO OPERATION. (NOTE THE SAFETY RELIEF VALVES WERE TESTED 4FEB87, TAMPA, FL AND WITNESSED BY CG AT 1.50PM. THIS IS TO BE COMPLETED TO THE SATISFACTION OF OFFICER IN CHARGE, MI.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Documentation
Issued 29 July 1985
Resolved
PROVIDE EVIDENCE TO MARINE SAFETY OFFICE, PORT ARTHUR, TEXAS OF CURRENT CERTIFICATE OF DOCUMENTATION AND LOADLINE CERTIFICATE.
Condition: Unknown
Due 29 July 1985
Resolved 29 July 1985
Electrical
Issued 15 June 1985
Resolved
REPAIR AND CONDUCT AN OPERATIONAL TEST OF THE GENERATOR SWITCHBOARD REVERSEPOWER RELAYS AS REQUIRED BY 46 CFR 111.12-11.
Condition: Unknown
Due 15 June 1985
Resolved 15 June 1985
Unknown
Issued 21 May 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL MM2, DN644380 AND ARE TO BE COMPLIED WITH BY 24JUN85.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
INSTALL SHUT OFF VALVE AND CHECK VALVE IN DRAIN LINE FOR DRIP PANS PORT AND STARBOARD TO THE SATISFACTION FO THE COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
REPAIR OR REPLACE ALL DETERIORATED PV VALVES ON CARGO TANKS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
DEMONSTRATE PROPER OPERATION OF TEST PROCEDURES ON BOTH PORT AND STAR- BOARD BOILERS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
STENCIL EMERGENCY FUEL SHUTDOWNS FOR THERMAL FLUID HEATER GENERATORS PRIOR TO 24JUN85 TO THE SATISFACTION OF OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
INSTALL GLOBES ON LIGHTS IN GENERATOR ROOM TO SATISFACTION OF COGNIZANT OCMI
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
INSTALL FLOW CONTROL VALVES IN SIGHT GLASS OF ALL FUEL DAY TANKS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
REPAIR REVERSE CURRENT RELAYS LOW LUBE OIL SHUTDOWN OVERSPEED TRIPS AND HIGH WATER TEMPERATURE SAFTIES ON BOTH GENERATORS TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
INSTALL WING NUTS ON VENTILATION DAMPERS FOR FANS IN MACHINERY SPACE PROVIDE PROPER SUPPORT AND FASTENERS FOR WIRE THAT RUNS TO MUD CHEMICAL PUMP. BOTH ITEMS TO BE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
REMOVE PAINT FROM BEHIND GENERATOR SWITCHBOARD AND PROVIDE APPROVED PAINT IF PAINT IS TO BE STORED ON BOARD TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
INSTALL DRAINS IN PORT AND STARBOARD AFT DRIP PANS TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Deck/Cargo
Issued 27 February 1984
Resolved
OPEN FOR INTERNAL EXAM OR CONDUCT A HYDRO EXAM OF 3 AIR RECEIVERS.
Condition: Unknown
Due 27 February 1984
Resolved 27 February 1984
Unknown
Issued 27 February 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL MM-2 DN644380.
Condition: Unknown
Due 27 February 1984
Resolved 27 February 1984