PACIFIC QUEEN
PACIFIC QUEEN is a 1944 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in March 2026, along with 45 deficiencies and 3 casualty investigations between 2016 and 2025.
Records from 2016 to 2026. Most recent: inspection, 27 March 2026.
- Built
- 1944
- Last inspected
- 27 March 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 45 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2016–2025
Identity
278349
WDK2568
43654
Flag
UNITED STATES
Maury page id
psix-43654
Inspections, by type
…with no type recorded3
Years with a record
11 calendar years (2016–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 9.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFELLOWS & STEWART INC · WILMINGTON, CA, UNITED STATES · built 1944
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 28
27 March 2026
In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8325839
8 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8294083
29 April 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8127404
29 April 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8140150
30 January 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8072464
2 December 2024
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8049323
6 August 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7991531
3 April 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889637
28 March 2024
Deadweight Survey · Inclining Experiment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7886691
6 December 2023
Construction Oversight · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7833796
12 June 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7802645
29 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7643385
17 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7596027
6 May 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7445560
1 December 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7360242
21 November 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7357162
22 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7180518
9 January 2020
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886389
21 November 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6853969
8 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830976
24 April 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6669306
1 March 2018
Annual Inspection · Deficiency Check · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6365026
5 December 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6318542
14 November 2017
Hull Examination · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6298531
13 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6123635
3 November 2016
Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6034887
8 June 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5901403
19 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5857603
Deficiency record · 45
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 March 2026
Resolved
Vessel's CO2 system was being serviced, provide servicing certificate once complete.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 March 2026
Resolved
Provide galley escape hatch with placard "EMERGENCY ESCAPE, KEEP CLEAR"
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2026
Resolved
Aft stateroom fire extinguisher found to be undersized (10-B:C), replace extinguisher with larger sized 2-A type.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 27 March 2026
Resolved
HF and Satcom phone to be inoperable. Prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 March 2026
Resolved
Renew 02 life rings that were found to be un-serviceable.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 April 2025
Resolved
Vessel experienced failures on both generators while underway. Troubleshoot fuel system and make corrective repairs. Prove proper operation of both generators prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 December 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port generator had a raw water leak on the pump. Fix leak and notify local OCMI once repairs are complete.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 December 2024
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. in compliance with 181.410. Vessel's CO2 system was not fully installed. Fully install CO2 system and notify local OCMI to conduct operational test of system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with
energized parts. Dead end wires found in engine compartment. Remove dead end wiring and update electrical plan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found 2 open circuits slots on starboard side breaker panel under the main helm. Properly encase the breaker panel and notify local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 December 2024
Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Electronic propulsion controller installed on vessel. QFA and DVTP not provided and test not completed. Provide QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP in the presence of local OCMI inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2024
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. Spanner wrench missing. Provide spanner wrenches.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2024
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 65 feet in length carrying more than 49 passengers must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Current nozzle on board vessel is plastic and does not meet 162.027. Provide nozzle that meets 162.027.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2024
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. 01 life ring buoys on board vessel are missing Type II retro-reflective material. 1 life ring buoy retro-reflective material is worn. Add/replace retro-reflective type material on all 02 life ring buoys
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2024
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. Eight life jackets were not marked with appropriate retro-reflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. Passenger count reduced to 34.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Generator box secured to shore power cable. Remove gen box and properly mount.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2024
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Wire in fore peak not supported every 24 inches. Provide supports for wiring every 24 inches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024
Resolved
Vessel was found with the A/C condensation line backflowing into a drainage pan and releasing a large quantity of water into the forward passenger berthing over several bunks. Install check valve or secure new piping system in away that prevents the line from backflowing into the vessel berthing.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 March 2023
Resolved
After March 24, 2019, a person may not employ or engage any individual on a national voyage that is required to hold an MMC unless that individual maintains a current medical certificate. 02 of the vessel's licensed crew members do not have evidence of a valid medical certificate. Provide evidence of valid medical certificates for the affected crew members. The affected crew mates may not stand in a licensed Master or Mate position on the vessel until this deficiency is rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 March 2023
Resolved
Provide accurate instructions for the release of the galley fixed fire extinguishing system in the vicinity of the manual operation station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2023
Resolved
Ring buoy lifeline was attached to the floating water light. Have a lifeline attached directly to the body of a ring buoy with at least 60 feet of line. This lifeline shall not be attached directly to the floating water light. Have a lanyard of 3-6 feet securing the water light around the body of the buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 March 2023
Resolved
Vessel's first aid kits are expired. Provide a valid first aid kit to the vessel or replace the expired components of the first aid kits. All expired components must be removed from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023
Resolved
Provide additional chaffing gear to the hydraulic hoses for the steering system that rubs against the steering hydraulic arms during operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2022
Resolved
All vessels holding a Certificate of Inspection must undergo an annual inspection with the three (03) months before and after each anniversary date. Vessel's required annual exam window lapsed on 15 APR 2022. Vessel operator was informed by the USCG Marine Inspector on required inspection window for vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2022
Resolved
The fire pump outlet must be fitted with a pressure gauge. Observed pressure gauge without protected cover over analog reader. Must repair to satisfaction of USCG Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 May 2022
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent it's loss. No securing device was on the hatch cover to the fore peak at the time of the inspection. Must correct to the satisfaction of the USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2021
Resolved
Both generators were found with unapproved fuel hose with single hose clamps at connections. Provide both generators with correct fuel piping/hose.
Options are: 1) install hard ferrous piping or copper tubing from manifold to generator, with USCG type A1, A2, B2, or B3 fuel rated hose, double hose clamped, less than 30" in length for final termination to generator. OR 2) install SAE J-1942 hose with SAE J-1475 fittings from manifold to generator.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2021
Resolved
02 fire extinguisher brakets were found with zip-ties holding latching mechanism together. Provide approved fire extinguisher brackets for crew bunk room and aft passenger bunk room.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2021
Resolved
One pipe and one electrical penatration were found to be non-vapor tight. Make aft engine compartment bulkhead vapor tight.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 April 2021
Resolved
The 2x12 lumber used for ladder steps was found to be broken/missing. Repair top two steps of ladder leading from crew bunk room.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2021
Resolved
Provide new placard or re-paint emergency fuel shutoff.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 April 2021
Resolved
Engine room escape ladder was not properly fastened to the escape trunk of the compartment. Properly mount engine room escape ladder.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 April 2021
Resolved
Forepeak hatch was found without a chain. Provide forward hatch with captive chain.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2021
Resolved
Vessel had multiple VHF radios, with only one which had LAT/LONG & MMSI information entered. Label specific VHF DSC radio which has LAT/LONG/MMSI, "DISTRESS RADIO"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020
Resolved
OLD BELZONA PATCH DISCOVERED ON RAW WATER SUPPLY PIPING DURING INSPECTION. PROVIDE REPAIR PLAN TO OCMI FOR THE PERMANENT REPAIR OF THE RAW WATER SUPPLY PIPING FOR THE PORT MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020
Resolved
REPLACE RETRO-REFLECTIVE TAPE PORT SIDE RING LIFE BUOY.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020
Resolved
ENSURE FORWARD AND STARBAORD SIDE RING LIFE BUOY HAVE VESSEL NAME IN CLEARLY LEGIBLE LETTERS.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 April 2017
Resolved
Provide vent covers for E/R vents
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 April 2017
Resolved
Install 2 blanks at 110v breaker panel under helm
Navigation › Piloting/Steering › Marine Charts
Issued 13 April 2017
Resolved
Provide current charts for area of operation
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 April 2017
Resolved
Provide current Coast Pilot
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 13 April 2017
Resolved
Provide draft marks at next drydock
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 April 2016
Resolved
Provide fire extinguisher bracket for extinguisher in galley.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 April 2016
Resolved
Provide update light list and coast pilot.
Casualty record · 3
8 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5901403
5 December 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6318542
29 April 2025Routine · role: Involved in a Marine Casualty · activity 8140150
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.