This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)220.0 ft × 52.0 ft × 12.0 ft
Registered tonnagegross 1,418 / net 1,418
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAVONDALE SHIPYARDS INC · AVONDALE, LA, UNITED STATES · built 1962
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationNo Operation - PM · issued 14 August 2007 · expires 30 September 2008
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1418 - Regulatory (Subpart C or D), Gross Ton 1418 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 39 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 8 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
towable rig collided with vessel on 18Jan05 and caused damages to hull.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 January 2005
Resolution: Cleared CG835 on 25JAN05 to satisfaction of the attending Coast Guard Inspector. see act #2279077 for details
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 August 2004Resolved
Replace broken Circut Breakers, #2 Heating Circulating Pump, and the Heater Contr4ol Alarm panel breaker prior to energizing the switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Electrical › Electric Generation Source (service) › Generator
Issued 11 August 2004Resolved
Generator Screens built up with grease and dirt, also internals of the generator will need cleaning prior to the use of the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 11 August 2004Resolved
Exhaust system lower level of the machinery room, clean entire system. To include all vents prior to vent system use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Engineering › Fuel Oil Service System › Valve
Issued 11 August 2004Resolved
The F/O crossover valve stbd side machinery room, repair/replace prior to use of any machinery, currently valve handle inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Deck/Cargo › Cargo Heating › General
Issued 11 August 2004Resolved
Insulation on Thermal Fluid Lines where missing, replace prior to the use of the Heating System.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Deck/Cargo › Cargo Heating › General
Issued 11 August 2004Resolved
Thermal fluid oil tank vent mising flame screen. Replace prior to use of system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Label all shut downs with what equipment they shut down. Generator chut down requires a raised sign. Thermal Fluid Heater shut down also requires raised sign.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 August 2004Resolved
#2 Cargo Tank aft expansion dome. Replace stbd hatch prior to any cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2004
Resolved 19 August 2004
Construction/Loadline › Penetrations › Gasket
Issued 11 August 2004Resolved
Port side aft of machinery room, void hatch, replace or repair dogs and clean knife edge on hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 19 August 2004
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 August 2004Resolved
Provide gauge readings on all ullage tops currently wastage indicates low thickness. or proove that these are just rain shields.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 17 August 2004
Resolution: The ullage openings are just rain shields verified by original prints of the vessel.
Documentation › Manuals/Policy Documentation
Issued 15 July 2003Resolved
Provide barge cargo piping diagram. LEGACY COMPONENT DESC: Transfer Procedures
Condition: Unknown
Due 15 August 2003
Resolved 24 July 2003
Documentation › Certificates/Documents
Issued 29 August 2002Resolved
Provide new COFR and Certificate Of Documentation reflecting any and all vessel name changes including changes of owner and operator. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Due 28 December 2002
Resolved 3 January 2003
Documentation › Certificates/Documents
Issued 29 August 2002Resolved
Provide Coast Guard Marine Safety Center with the following for stability and structural evaluation: 1. Tank characteristics including volume and capacity. 2. Documentation that raised tank trunk is suitable for the max design pressure iaw ABS Rules. 3. Calculations for intact and damage stability.
Condition: Unknown
Due 28 December 2002
Resolved 7 April 2003
Construction/Loadline
Issued 20 July 1998Resolved
Vesel damaged in collision 13JUL98, damage to stbd #1 void from the 7'_x001C_ draft mark extending to deck knuckle. 25' of side shell including deck knuckle. Vessel permitted to discharge cargo (sulfur) at CYTEC and proceedto Elmwood DD Harvey detail for gas free and repairs. Transit unloaded._x001C_
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Construction/Loadline
Issued 4 June 1998Resolved
REPLACE THE FORWARD PULL STATION CABLE WITH PROPER CABLE.
Condition: Unknown
Due 4 July 1998
Resolved 23 June 1998
Engineering
Issued 26 May 1992Resolved
PROVIDE INSTRUCTION BOOKLET FOR THERMAL FLUID HEATER AS PER _x001C_ 46 CFR 63.05-95 (B)
Condition: Unknown
Due 26 June 1992
Resolved 10 June 1992
Deck/Cargo
Issued 26 May 1992Resolved
PROVIDE WRITTEN PROOF ATTESTING THE FACT THAT CARGO PIPING AND HOSES AND _x001C_ SAFETY VALVE (S) HAVE BEEN TESTED IN ACCORDANCE WITH 33 CFR 154.500.
Condition: Unknown
Due 26 June 1992
Resolved 10 June 1992
Deck/Cargo
Issued 22 July 1982Resolved
HAVE CARGO TANKS MADE GAS FREE AND MAKE AVAILABLE TO U.S. COAST GUARD FOR INTERNAL EXAM PRIOR TO LOADING OF CARGO AND NOT LATER THAN 22AUG82.
Condition: Unknown
Due 22 August 1982
Resolved 22 July 1982
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.