Records from 1982 to 2022. Most recent: inspection, 19 September 2022.
Inspection history · 82
19 September 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7562311
23 March 2022
Deficiency Check · Internal Structural Exam · Administrative Inspection · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7416752
8 May 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6950743
8 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6951271
6 February 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6903956
2 February 2020
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6911602
26 November 2019
Internal Structural Exam · Damage Survey · Drydock Exam · MTSA Verification · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6863140
8 August 2019
Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6776878
22 February 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6630286
17 November 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308764
20 April 2017
Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6128842
9 November 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6038393
22 October 2015
Administrative Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5748893
27 October 2014
Examination of Repairs · Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5011560
18 November 2013
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4754684
15 October 2013
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4732773
4 December 2012
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4495708
28 November 2012
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4493064
6 August 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4403230
26 March 2012
Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4272011
9 August 2011
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4111445
13 August 2010
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3823166
2 May 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3729603
26 March 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3703593
14 August 2009
Spot Check · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3565005
27 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3462059
25 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2724710
26 January 2005
MTSA Verification · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2280788
28 June 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2115174
17 February 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2007582
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998686
6 May 2003
Administrative Inspection
Administrative · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1787841
7 February 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1737015
26 April 2002
Damage Survey · Examination of Repairs
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1607338
22 January 2002
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1480136
17 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 41217
17 July 2001
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405232
16 February 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059413
19 January 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447028
28 January 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401171
9 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458607
14 July 1998
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472123
19 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 128143
28 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419877
24 January 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400482
23 January 1997
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464662
19 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086144
26 January 1996
Deficiency Check · COI Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428524
14 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1190078
8 June 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377435
22 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 757911
13 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 118444
13 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 191287
27 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 34847
22 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135689
15 June 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465149
13 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 88386
13 April 1994
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 857156
9 June 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1150858
25 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136238
11 September 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 528973
24 June 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 953311
8 January 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951157
5 January 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258273
13 September 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353298
18 June 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897869
15 November 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914948
15 August 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215078
4 December 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907206
9 June 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891589
1 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208222
13 June 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890779
29 May 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308374
7 October 1986
Damage Survey · Examination of Repairs
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1322797
5 October 1986
Damage Survey
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1315278
9 July 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310133
11 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300075
14 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295481
20 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982073
28 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970886
10 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963960
3 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272266
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 23 March 2022
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine.
When tested, the port aft prime mover did not shutdown after pulling the emergency shutdown.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2022
Resolved 24 March 2022
Resolution: Tested the manual shutdown, tested satisfactorly.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 March 2022
Resolved
Hull and deck houses shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
02 Pin holes were found within the bow rake into the next aft void, 02 pin holes were found on the tank tops into the voids surrounding the cargo tanks, and 03 vertical supports had cracked welds in #2 port wing void. Provide USCG Inspectors a repair plan and conduct approved permanent repairs. Temporary repairs in the form of a doubler plate was approved by USCG Inspector. Affect permanent repairs within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 20 April 2022
Resolution: Witnessed satisfactory repair of the collision bulkhead in the form of an 18"x30" insert with a satisfactory NDT via hose test.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 March 2022
Resolved
Hull and deck houses shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
MI discovered a pipe spanning the width of the aft cargo tank void that had rusted and broke free from the STBD bulkhead. Pipe is resting on top of the cargo tank. Make permanent repairs to secure and repair pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2022
Resolved 24 March 2022
Resolution: Pipe was removed and capped off to prevent water intrusion.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 March 2022
Resolved
Hull and deck houses shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
01 pin hole were located on the FWD port side, 02 pin holes were located on the FWD STBD side. Provide repair plan to include and conduct approved permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2022
Resolved 24 March 2022
Resolution: Doubler plates used to cover wasted pin holes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2022
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards.
There was an opening present in the switchboard which present an electrical shock hazard. Install required amount of blanking plates.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2022
Resolved 24 March 2022
Resolution: Opening closed using a blank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2022
Resolved
Each switchboard must have a voltmeter to show the generator voltage of each phase.
Voltmeter on the switchboard would fluctuate from 50V to 240V while generator was running.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2022
Resolved 24 March 2022
Resolution: New gauge installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 March 2022
Resolved
Gears, couplings, flywheels, and all machinery capable of injuring personnel shall be provided with adequate covers or guards.
Inspector noticed the STBD FWD Prime mover did not have a guard over the belt, vessel rep replaced on the spot and installed the guard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2022
Resolved 23 March 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Dead end wiring was discovered in the bow rake as well as in the generator room. Remove/properly enclose the wire ends to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2019
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Marine inspectors found openings in the switchboard which pose an electrical shock hazard to personnel. Install blank covers on openings in switchboard to remove shock hazard to personnel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2019
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2019
Resolved
Barge's draft marks are no longer visible in contrasting color on the bow and stern. Have draft marks re-painted in contrasting color to ship's hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2019
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Batteries are required to be contained in a battery box per 46 CFR 111.15-5. Batteries were found in generator room out on deck not in a proper containment. Place the batteries in a box meeting regulations or remove from barge.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2019
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2019
Resolved
Name of barge is only marked on the stern. Name/number of the barge is required to be marked so that it can be read from either side of the vessel. Provide marking meeting 46 CFR 32.05-15 so the name of the barge can be read from either side.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2019
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 February 2019
Resolved
Marine inspectors discovered water leak onto generator. Electrical equipment is required to be protected from dripping liquids. Remove leak and prevent drip hazard onto generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2019
Resolved 26 February 2019
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 28 October 2015
Resolved
Vessel's starboard cargo pump engine has radiator leak so MI was unable to witness engine running or emergency shutdown. Demonstrate proper operation of engine and emergency shutdown in presence of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2015
Resolved 28 October 2015
Resolution: MI attended and witnessed satisfactory operation of engine and emergency shutdown.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 22 October 2013
Resolved
Lights shall be operable to show if a ground is present in the system. Replace lamps (or repair wiring if needed) to show the presence a ground in the system when the Ground detection button is depressed.
Action required: 705 - Other - as specified
Due 23 November 2013
Resolved 18 November 2013
Resolution: Item resolved, ground detection is operational.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 22 October 2013
Resolved
Currently there are several openings on the switchboard. There should be no areas on the switchboard were a crew member would be able to put an appendage or object into. Openings in switchboard need to be covered and non accessible to passengers. Provide covers and screws/bolts to contain all areas of switchboard from potential hazards.
Action required: 705 - Other - as specified
Due 23 November 2013
Resolved 18 November 2013
Resolution: Item resolved, no current openings on switchboard
Engineering › Steam Boiler (auxiliary/waste heat) › Feed pipe
Issued 28 November 2012
Resolved
Replace thermal fluid heater flexible hose line in the fixed piping line as needed.
Action required: 705 - Other - as specified
Due 28 December 2012
Resolved 2 December 2012
Resolution: Vsl replaced hose. Conducted operational test of thermal fluid heater. All sat. Inspection complete. CG835 cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 August 2009
Resolved
Properly secure all three portable fire extinguishers.
Action required: 705 - Other - as specified
Due 18 September 2009
Resolved 1 September 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 August 2009
Resolved
Provide proper servicing report for portable extinguishers IAW NFPA.
Action required: 705 - Other - as specified
Due 18 September 2009
Resolved 1 September 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 August 2009
Resolved
Submit cargo piping drawings and specifications to MSC for approval.
Action required: 705 - Other - as specified
Due 10 October 2009
Resolved 27 October 2009
Resolution: MSC Approval letter received.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 February 2004
Resolved
Repair or replace AMP meter on battery charger in machinery space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Resolution: AMP meter replaced.
Construction/Loadline › Structures › Manhole
Issued 17 February 2004
Resolved
Renew or replaced hinge/bolts on forward rake access coaming/hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Resolution: Bolts replaced and tightened.
Construction/Loadline › Penetrations › Pipe Flange
Issued 17 February 2004
Resolved
Cap or crop and plug out of service 1" pipes that penetrate both forward and aft tank top covers near cargo piping on tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 19 February 2004
Resolution: Pipes capped.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 January 2002
Resolved
Replac shattered light globe stbd side house outside door.
Condition: Unknown
Due 22 January 2002
Resolved 23 January 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 January 2002
Resolved
Replace missing break glass hammer on activation controls.
Condition: Unknown
Due 22 January 2002
Resolved 22 January 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 January 2002
Resolved
Aft cargo pump engine, replace L/O drain line, currently worn beyond service.
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Deck/Cargo › Cargo Heating
Issued 22 January 2002
Resolved
Replace missing drain plug in thermal fluid heating tank. Drain valve is missing its plug.
Condition: Improper/Lack of Maintenance
Due 23 January 2002
Resolved 23 January 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 22 January 2002
Resolved
Replace wasted valve handle on the aft cargo pump discharge line.
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 22 January 2002
Resolved
Replace both flame creens and screen attaching collars on the F/O tank vents, port side of house, currently plastic flame creen collars installed and one wasted.
Condition: Improper/Lack of Maintenance
Due 23 January 2002
Resolved 23 January 2002
Navigation
Issued 22 January 2002
Resolved
Straighten stbd bow navigation light stand, currently bent. LEGACY COMPONENT DESC: Navigation Ligtht Stands
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 January 2002
Resolved
Fwd cargo pump engine re-install F/O supply line bracket and mount back to deck, currently F/O line loose.
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Deck/Cargo
Issued 17 July 2001
Resolved
Clean and gas free #1 cargo tank and associated voids and make repairs to thermal fluid heater lines to the satisfaction of the attending CG Marine Inspector.
Condition: Unknown
Due 17 August 2001
Resolved 8 August 2001
Deck/Cargo
Issued 17 July 2001
Resolved
Demonstrate all TFH safetys to the satisfaction of the attending CG Marine Inspector.
Condition: Unknown
Due 17 August 2001
Resolved 8 August 2001
Deck/Cargo
Issued 17 July 2001
Resolved
Vessel to proceed to Uncle Sam, as is, to replace #1 cargo pump.
Condition: Unknown
Due 17 August 2001
Resolved 8 August 2001
Construction/Loadline
Issued 19 January 2001
Resolved
REWELD THIRD TRUSS FROM FORWARD WELD TO LONG AS NEEDED IN 3 STARBOARD COMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW BOTTOM LONG IN CARGO TANK COFFERDAM VOID LOCATED IN PORT FORWARD SIDE.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW OUTBOARD LONG AND CORNER BRACKET IN BOW VOID, STARBOARD COMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW SECOND LONG FROM THE TOP IN BOW VOID, STARBOARD AFT COMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW TWO OUTBOARD LONGITUDINALS AND VERTICAL BRACKETS IN BOW VOID, PORT COMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW THIRD FRAME AFT, TOP OUTBOARD LONGITUDINAL IN BOW VOID, PORTCOMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW 45 DEGREE ANGLE BRACKET IN BOW VOID, PORT COMPARTMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW FORWARD OUTBOARD CORNER TOP LONGITUDINAL IN STARBOARD NUMBER1 VOID.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 January 2001
Resolved
CROP AND RENEW AFT OUTBOARD CORNER BRACKET, SECOND FROM THE BOTTOM, IN NUMBER 2 STARBOARD VOID. ALSO PUMP OUT VOID.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 8 June 1995
Resolved
PROVIDE GAUGINGS AND REPAIR PROPOSAL FOR PERMANENT REPAIRS TO COAMING OF AFT HOPPER TRUNK IN VICINITY OF HOLES.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 8 June 1995
Resolved
REPAIR WASTED GOOSENECK VENTS ON ALL VOIDS.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 8 June 1995
Resolved
PROVIDE NDT RESULTS AND REPAIR PROPOSAL AS NECESSARY FOR WASHED OUT WELDS ON DECK, PORT AND STBD AFT CORNERS, IN VICINITY OF DOUBLER PLATE UNDER MOORING BUTTONS.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Deck/Cargo
Issued 8 June 1995
Resolved
MAKE FORWARD CARGO PUMP ENGINE TO STOP WHEN REMOTE SHUTDOWN IS PULLED. CARGO IS NOT TO BE TRANSFERED THROUGH FORWARD CARGO PUMP UNTIL REMOTE SHUTDOWN IS OPERABLE.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Deck/Cargo
Issued 5 January 1992
Resolved
PRIOR TO LOADING ANY CARGO MAKE REPAIRS TO THE CARGO PIPING INBOARD OF MANIFOLD, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1992
Resolved 5 January 1992
Construction/Loadline
Issued 18 June 1991
Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS IN PORT SIDE OF WEATHER COVER AND INAREA AROUND AFT CARGO HATCH TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Construction/Loadline
Issued 18 June 1991
Resolved
DRYDOCK BARGE AND MAKE AVAILABLE FOR INSPECTION TO EVALUATE EXTENT OF DAMAGE IN PORT HULL OF BOW VOID.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Deck/Cargo
Issued 18 June 1991
Resolved
REMOVE LAGGING AND INSULATION FROM PORT SIDE OF #2 CARGO TANK TO DETERMINE EXTENT OF SULFER CONTAMINATION AND LOCATION OF LEAK IN STERN TANK.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Construction/Loadline
Issued 18 June 1991
Resolved
PROVIDE ATTENDING MARINE INSPECTOR WITH REPAIR PROPOSAL FOR DAMAGES FOUND IN BOW VOID AND #2 CARGO TANKS PRIOR TO INITIATING REPAIRS.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Construction/Loadline
Issued 9 June 1989
Resolved
STENCIL 'DANGER KEEP OUT' ON CARGO TANK HATCH COVERS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Fire Fighting
Issued 9 June 1989
Resolved
INSTAL BRACKET FOR FIRE EXTINGUISHER.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Deck/Cargo
Issued 9 June 1989
Resolved
REMOVE EXCESSIVE OIL FROM BILGE IN THERMAL FLUID HEATER ROOM
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989
Resolved
DEMONSTRATE PROPER OPERATION OF S/S GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Documentation
Issued 13 June 1988
Resolved
SUBMIT VESSEL'S DOCUMENT TO DOCUMENTATION OFFICE NEW ORLEANS FOR CORRECTION OF VESSEL'S LENGTH
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Unknown
Issued 5 October 1986
Resolved
MAKE THE BOW RAKE AND #1 STARBOARD VOID GAS FREE AND AVAILABLE TO A COAST GUARD MARINE INSPECTOR PRIOR TO DEPARTING HOUSTON, TEXAS.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Unknown
Issued 5 October 1986
Resolved
DISCHARGE ALL CARGO FROM ALL CARGO TANKS PRIOR TO DEPARTING ARCO DOCKS, HOUSTON, TEXAS.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986