Records from 1996 to 2026. Most recent: inspection, 19 July 2026.
Inspection history · 60
19 July 2026
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 8441983
28 May 2026
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8324375
18 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8166005
3 June 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8150732
24 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7965291
13 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7785217
2 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675835
17 March 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7413052
8 March 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7418668
8 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170883
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108390
24 September 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7124822
16 April 2020
Administrative Inspection · Exemption · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6940168
17 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6664838
4 April 2019
Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6655905
2 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6463819
3 January 2018
In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6331990
13 June 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6174301
5 June 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6166560
9 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5902434
2 September 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5232610
28 August 2015
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5228205
19 August 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4959698
26 June 2012
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4357105
14 September 2011
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4149000
9 September 2011
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4140185
19 August 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4126879
5 August 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4106294
14 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4081617
11 January 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3924572
19 December 2010
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3913594
12 October 2010
Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3868556
22 March 2010
Construction Oversight
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3700666
4 September 2008
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3309608
29 September 2007
Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3068889
22 February 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2876530
6 October 2005
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2507596
29 November 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2249670
16 March 2004
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2025731
9 October 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1924825
30 August 2002
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1666655
26 March 2002
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1597429
16 October 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1074350
15 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468985
13 June 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456847
22 September 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338671
31 August 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1420192
29 April 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 770937
27 April 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 142859
27 April 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 211111
4 September 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 129853
4 September 1998
Damage Survey · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802618
10 August 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408141
22 August 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421387
12 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113747
19 March 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 774558
10 January 1997
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098023
7 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 98351
7 January 1997
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404291
6 September 1996
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447626
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 May 2026
No resolution recorded
An interconnected detection and alarm system must: be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d), vsl had detectors in crew accommodation, audible in hall/galley was heard, but no visual w/in the crew accommodation. Make system meet visual regulation.
46 CFR 181.450(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2026
Resolved
Exhaust piping shall be properly supported by non-combustible hangers or blocks. Multiple exhaust hangers were missing securing bolts.
46 CFR 182. 20-20 (Old T)
46 CFR 182. 15-20 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 29 May 2026
Resolution: Received adequate documentation that the exhaust hanger securing bolts were reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2025
Resolved
46 CFR 176.830 (a)
At each inspection all observed unsafe practices shall be corrected. Missing deck plate and unsecured deck plates in e/r.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2025
Resolved 18 June 2025
Resolution: Deck plates were corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2024
Resolved
A vessel must comply with the structure design requirements of ABS alumuium vessel rules if more than 100ft in length. Vessel has several punctures, fractures, and broken welds in the AFT transam area marked "CG"
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2024
Resolved 24 August 2024
Resolution: Cracked welds repaired and insert passed dye pen NDT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024
Resolved
Crew berthing and washing areas must now prominently display details concerning company policies how to report issues, and steps to respond to sexual assault and sexual harassment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 25 June 2025
Resolution: Vessel is under 100 gross tons and is not applicable for the SASH signage, but signage posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. Vessel did not have an interconnected fire detection system but was aware and on a wait list to have company install and update current detection system.
46 CFR 181.405(c)
46 CFR 181.450
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2023
Resolved 25 June 2025
Resolution: Interconnected system installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 March 2022
Resolved
Fire pump suction piping at elbow to the pump had a 3/8 inch hole that would not allow pump to self prime.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Elbow was replaced and operationally tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
Main engine RACOR filters did not have required plugs on sediment valves for main engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Required plugs installed on all RACOR filter valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 March 2022
Resolved
STBD Generator RACOR filters were leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Replaced filter bowl and leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Switch board was missing interlock bar.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 17 March 2022
Resolution: Crew replaced interlock bar as required during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 March 2022
Resolved
#1 MPDE control panel had evidence of water leaking from soft patch in overhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Soft patch was properly sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 March 2022
Resolved
Holes were discovered above #1MPDE exhaust and #4 MPDE air boxes and a cracked frame in the lazerette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Holes in overhead above #1 MPDE and air box above #4 MPDE were welded. Cracked frame in lazareete was cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 March 2022
Resolved
Crack was discovered on the Main deck mid body.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Mid body crack was V ground and welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
#1 MPDE has a leaking reduction gear cooler.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: New Coolers are on oder to be replaced when recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 March 2022
Resolved
Frequency gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 17 March 2022
Resolution: New Gauge was installed during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 March 2022
Resolved
Life floats life lines are deteriorating due to ultraviolet light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: All deteriorated life lines were replaced with new line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Steering gear hydraulic lines were made of non- standard type material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Hydralic lines were replaced with new equivelant hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Hydraulic tank fill line deck penetrations were not full
full welded allowing water intrusion.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: All tank fill connection were full pentration welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Leaking ballast piping was discovered in the generator room stdb side near OVHD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Piping was cropped and renewed as required.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 March 2022
Resolved
Fire plugs on main deck at hose nipples were deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Fire plug hose nipples were cut out and renewed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 March 2022
Resolved
Vessel transfer procedures were deteriorated and un-legible.
Every crew member must partic
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: New legible transfer procedures were posted at control panel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2022
Resolved
Drills were not being logged in ships log book.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Drills were logged as required in the ships log book.
Electrical › Electric Generation Source (service)
Issued 9 October 2003
Resolved
Over current devices on generators are required to be de-rated to 80% of full load capacity/rating. Additional name plate specifying the de-rated capacity required to be on generators. 46 CFR 183.10-5(f)(2)/46 CFR 183.320(b)(2).
The above requirement to be completed by 2004 dry dock period. LEGACY COMPONENT DESC: Generator
Due 26 March 2004
Resolved 19 March 2004
Resolution: New labels affixed to generators showing rating for 50 degree service.
Construction/Loadline
Issued 31 August 1999
Resolved
Install bilge high level alarm in rudder room and forward hold/pump room per 46 CFR 182.530.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Electrical
Issued 31 August 1999
Resolved
Properly mount new electrical cables in engineroom overhead.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Construction/Loadline
Issued 31 August 1999
Resolved
Repair broken/missing welds in aft corners of rudder room.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 31 August 1999
Resolved
Properly label distress signal container.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Engineering
Issued 31 August 1999
Resolved
Install machinery guards on all four engines.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 31 August 1999
Resolved
Replace port forward fuel vent flame screen.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Construction/Loadline
Issued 4 September 1998
Resolved
CROP OUT AND RENEW A MINUMIN OF 18"X18" INSERT IN THE SIDE SHELL STARBOARD FUEL #2 DAY TANK IN WAY OF FRAME 9. TANK SHALL BE GAS FREE AND CERTIFIED BY A MARINE CHEMIST. DUE TO A 4" INSET AND HOLE CAUSED BY A MOORING PILE.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998