Records from 2010 to 2026. Most recent: inspection, 19 July 2026.
Documentation record
Registered dimensions (L × B × D)126.8 ft × 27.0 ft × 12.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)126.8 ft × 27.0 ft × 12.0 ft
ITC tonnagegross 266 / net 79
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1996
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAROSE, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
266 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
79 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
19 July 2026
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 8441983
28 May 2026
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8324375
18 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8166005
3 June 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8150732
24 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7965291
13 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7785217
2 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675835
17 March 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7413052
8 March 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7418668
8 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170883
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108390
24 September 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7124822
16 April 2020
Administrative Inspection · Exemption · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6940168
17 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6664838
4 April 2019
Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6655905
2 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6463819
3 January 2018
In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6331990
13 June 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6174301
5 June 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6166560
9 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5902434
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 May 2026
No resolution recorded
An interconnected detection and alarm system must: be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d), vsl had detectors in crew accommodation, audible in hall/galley was heard, but no visual w/in the crew accommodation. Make system meet visual regulation.
46 CFR 181.450(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2026
Resolved
Exhaust piping shall be properly supported by non-combustible hangers or blocks. Multiple exhaust hangers were missing securing bolts.
46 CFR 182. 20-20 (Old T)
46 CFR 182. 15-20 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 29 May 2026
Resolution: Received adequate documentation that the exhaust hanger securing bolts were reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2025
Resolved
46 CFR 176.830 (a)
At each inspection all observed unsafe practices shall be corrected. Missing deck plate and unsecured deck plates in e/r.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2025
Resolved 18 June 2025
Resolution: Deck plates were corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2024
Resolved
A vessel must comply with the structure design requirements of ABS alumuium vessel rules if more than 100ft in length. Vessel has several punctures, fractures, and broken welds in the AFT transam area marked "CG"
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2024
Resolved 24 August 2024
Resolution: Cracked welds repaired and insert passed dye pen NDT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024
Resolved
Crew berthing and washing areas must now prominently display details concerning company policies how to report issues, and steps to respond to sexual assault and sexual harassment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 25 June 2025
Resolution: Vessel is under 100 gross tons and is not applicable for the SASH signage, but signage posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. Vessel did not have an interconnected fire detection system but was aware and on a wait list to have company install and update current detection system.
46 CFR 181.405(c)
46 CFR 181.450
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2023
Resolved 25 June 2025
Resolution: Interconnected system installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 March 2022
Resolved
Fire pump suction piping at elbow to the pump had a 3/8 inch hole that would not allow pump to self prime.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Elbow was replaced and operationally tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
Main engine RACOR filters did not have required plugs on sediment valves for main engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Required plugs installed on all RACOR filter valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 March 2022
Resolved
STBD Generator RACOR filters were leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2022
Resolution: Replaced filter bowl and leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Switch board was missing interlock bar.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 17 March 2022
Resolution: Crew replaced interlock bar as required during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 March 2022
Resolved
#1 MPDE control panel had evidence of water leaking from soft patch in overhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Soft patch was properly sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 March 2022
Resolved
Holes were discovered above #1MPDE exhaust and #4 MPDE air boxes and a cracked frame in the lazerette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Holes in overhead above #1 MPDE and air box above #4 MPDE were welded. Cracked frame in lazareete was cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 March 2022
Resolved
Crack was discovered on the Main deck mid body.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Mid body crack was V ground and welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
#1 MPDE has a leaking reduction gear cooler.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: New Coolers are on oder to be replaced when recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 March 2022
Resolved
Frequency gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 17 March 2022
Resolution: New Gauge was installed during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 March 2022
Resolved
Life floats life lines are deteriorating due to ultraviolet light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: All deteriorated life lines were replaced with new line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Steering gear hydraulic lines were made of non- standard type material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Hydralic lines were replaced with new equivelant hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Hydraulic tank fill line deck penetrations were not full
full welded allowing water intrusion.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: All tank fill connection were full pentration welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2022
Resolved
Leaking ballast piping was discovered in the generator room stdb side near OVHD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Piping was cropped and renewed as required.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 March 2022
Resolved
Fire plugs on main deck at hose nipples were deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Fire plug hose nipples were cut out and renewed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 March 2022
Resolved
Vessel transfer procedures were deteriorated and un-legible.
Every crew member must partic
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: New legible transfer procedures were posted at control panel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2022
Resolved
Drills were not being logged in ships log book.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2022
Resolved 21 March 2022
Resolution: Drills were logged as required in the ships log book.