MAURY USCG vessel records Sign in
← All vessels

MR. CADE

MR. CADE is a 2003 passenger vessel (inspected). The Coast Guard has recorded 56 inspections since 2003, most recently in May 2026, along with 21 deficiencies, 1 operational control and 2 casualty investigations between 2015 and 2021.

Records from 2003 to 2026. Most recent: inspection, 12 May 2026.

Built
2003
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9307774 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH4027
659848
Flag
UNITED STATES
338173000
Maury page id
psix-659848

Inspections, by type

…with no type recorded9
Years with a record 22 calendar years (2003–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)143.3 ft × 29.8 ft × 12.5 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)143.3 ft × 29.8 ft × 12.5 ft
ITC tonnagegross 363 / net 108
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
363 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
108 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4027MMSI 338173000 · active · compulsorily equipped · granted 23 March 2024, expires 3 April 2034
WDB5803MMSI 369335000 · cancelled · compulsorily equipped · granted 2 November 2013, cancelled 26 March 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOL LIGHTNING Passenger (Inspected) · MISLE 445102 · 8 March 2022 · activity 7418668HERO Passenger (Inspected) · MISLE 484407 · 8 March 2022 · activity 7418668LADY ALYSE Offshore Supply Vessel · MISLE 7766 · 12 December 2015 · activity 5810644

Inspection history · 56

12 May 2026 Administrative Inspection · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8371943
11 March 2025 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8089386
26 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7942756
28 May 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7921982
21 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7773126
16 August 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7769953
5 June 2023 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7703986
31 May 2023 Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7703957
19 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7433695
4 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7424517
8 March 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7418668
3 February 2022 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7390148
21 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7371292
2 December 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7360838
2 December 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7379576
27 August 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7297191
17 June 2021 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7288305
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108441
27 May 2020 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6961559
22 April 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6941771
16 December 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6874346
1 November 2019 Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6847318
15 February 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6638835
7 November 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6576346
4 October 2018 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6564382
12 September 2018 Hull Examination · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6537852
31 October 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6298480
13 October 2017 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6287137
5 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118611
24 January 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6076490
1 February 2016 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5807414
12 December 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5810644
20 October 2015 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5747300
16 October 2015 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5746369
27 July 2015 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5198789
25 July 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5198783
27 August 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4967275
14 December 2011 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4207140
7 December 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4202617
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200222
28 September 2011 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4156636
27 September 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4155817
21 December 2010 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914486
15 December 2009 Drydock Exam · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3650438
18 November 2008 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3365239
10 December 2007 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3117422
23 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2914021
23 February 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879597
2 February 2007 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867950
23 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806469
1 December 2005 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2543645
15 February 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2308209
10 February 2005 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2290279
3 June 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087390
2 February 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1998616
17 November 2003 COI Inspection · Inclining Experiment · Construction Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1949410

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. #1 MDE had a severe oil leak on the outboard aft of the engine causing a constant flow of hot oil onto the engine electrical components and directly into the bilge. *** Vessel is authorized to proceed directly to New Iberia for repairs to #1 MDE. Vessel shall not operate #1 MDE unless an emergency occurs. Vessel shall inform MSD Lafayette of location of repairs*** 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2023
Resolution: Witnessed new #1 MDE installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2023 Resolved
At each initial and subsequent inspection of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Port generator had an oil leak from the rear of the prime mover that splashed onto the electrical wires and components. 46 CFR 176.804(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2023
Resolution: Generator had rear seal replaced. Witnessed op test. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Switchboard panel had an active ground. 46 CFR 183.200
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2023
Resolved 30 August 2023
Resolution: Ground was identified and replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Distribution panel in generator space has a blank missing for one of the breakers. 46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 August 2023
Resolution: Vessel installed blank to cover open access.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 August 2023 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead. Watertight door entering lazarette had 1/2"-1" gap on 02 dogs. 46 42.15-10(a)
Action required: 10 - Deficiency Rectified
Due 17 August 2023
Resolved 17 August 2023
Resolution: Tightened loose dogs on water tight dooor, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 April 2022 Resolved
Each Vessel operating on a Coastwise route must be provided with life floats of an aggregate capacity that will accommodate at least 100 percent of the total number of persons on board. Life rafts are currently removed for servicing and to accommodate work on engine. Coast Guard will verify in person that life rafts are properly installed. Cite 45CFR180.204(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Properly maintained inflatable liferafts were installed with new detachable links. Inspection paperwork was verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating neccesary requirements. Number two engine currently removed for work. Cite: 46CFR182.200(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Rebuilt engine was installed. Operation tests performed including remote shut downs. All guages were functional from all operating stations.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 December 2021 Resolved
he construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel sustained multiple gashes in the port side hull area after striking a Single well structure. Vessel is to return back to Venice to make repairs. 46 CFR 177.100 60/C
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 February 2022
Resolution: Conducted examination of hull repairs, all sat. Verified all navigation equipment was in good working order. Received tech report of installation and tests of new fire panel on bridge.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 December 2019 Resolved
A vessel must have a valid Certificate of Documentation. Vessel does not have a valid COD on board. IAW 46 CFR 67.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 15 January 2020
Resolution: Current COD now onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 December 2019 Resolved
A vessel must carry accurate and up-to-date navigation publications. Vessel does not have updated Nav rules and currents publications. IAW 46 CFR 184.420(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 17 January 2020
Resolution: Vessel has new Nav rules book and electornic version of the current publications.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2019 Resolved
Wire connections must be made in an enclosure. The water column wires are cut. IAW 46 CFR 183.340(g).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 15 January 2020
Resolution: Water column gauges / alerts were no longer used. They were attached to older engines which have been replaced. Newer Engines use sensors alarming on bridge to temperature issues. Gauges and wiring were removed and discarded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019 Resolved
Code 1301: Repairs and alterations that affects the safety of the vessel must not be made without the approval of the OCMI, except during emergency. Repairs include, but are not limited to replacement of propulsion equipment or systems. Vessel propeller servicing the main diesel propulsion engine number 1 (portside-outboard engine) lost a blade while operating, resulting in excess vibration. Properly replace propeller as in kind and also must submit via email to [email withheld] a written statement from vessel designer/manufacturer that vessel can be safely operated on 3 engines without compromising the safety operational envelope of the vessel while carrying cargo and persons.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2019
Resolved 27 May 2020
Resolution: Vessel replaced #1 propeller to the satification of the Marine Inspector during Drydock/ Hull/ ISE exam.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 February 2016 Resolved
Vessel is reporting both Port propellers caught up on the rocks during grounding. Vessel must prove safe operation prior to departing EPS dock Venice, LA to Superior shipyard, Golden Meadow, LA for dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 February 2016
Resolution: Rcvd Master's letter and voyage plan for transit to dry dock.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 February 2016 Resolved
Vessel is to proceed to emergency dry dock and conduct damage survey in dry dock at Superior Shipyard, Golden meadow, LA and make all neccessary repairs prior to departure to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 November 2017
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 21 October 2015 Resolved
Replace exhaust lagging and missing bolt on #1 MDE. Vessel representative had it removed to for replacement, not completed at time of inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 October 2015
Resolution: Exhaust lagging and missing bolt replaced.
Fire Fighting › Ventilation Systems › Fans
Issued 21 October 2015 Resolved
Clean excessive residue on port generator exhaust fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 October 2015
Resolution: Port generator exhaust fan cleaned.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 21 October 2015 Resolved
Repair watertight bulkhead penetration from removed wire spaces between generator & rudder room with same material as existing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 October 2015
Resolution: Watertight bulkhead penetration repaired to watertight integrity.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 October 2015 Resolved
Replace seal on treated sewage lift pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 11 November 2015
Resolution: Seal replaced and system tested no leaks.
Construction/Loadline › Hull › Hull Plating
Issued 28 September 2011 Resolved
Tire bracket caused wear on hull plating. Crop and renew
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 September 2011
Resolution: New plate installed to the satisfaction of ABS Surveyor
Navigation › Piloting/Steering
Issued 17 November 2003 Resolved
Provide approved steering system plans.
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 16 January 2004
Resolution: Provided.
Engineering
Issued 17 November 2003 Resolved
Provide approved Oily Water Separator plans.
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 28 January 2004
Resolution: Provided.

Casualty record · 2

12 December 2015Routine · role: Involved in a Marine Casualty · activity 5810644
2 December 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7379576
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.