Records from 1997 to 2019. Most recent: inspection, 11 June 2019.
Inspection history · 52
11 June 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6710585
22 November 2016
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6045508
12 April 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5852822
4 December 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5775641
10 September 2015
Periodic Inspection · Deficiency Check · SIP Initial Entry · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5742508
29 July 2015
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5199630
21 April 2015
Load Line/Change of Employment · Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5108683
16 April 2015
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5149422
3 April 2015
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5097673
5 March 2015
Load Line/Change of Employment · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5079630
2 May 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4848373
29 March 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4274881
8 February 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263724
12 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3890072
18 March 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3721657
8 June 2009
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3498862
29 May 2009
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3489801
12 January 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392775
25 March 2008
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3171157
20 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3118700
24 July 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3006113
16 July 2007
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2997235
2 May 2007
Hull Examination · Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2920949
26 February 2007
Drydock Extension
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2879205
19 January 2006
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2568034
29 March 2005
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2322193
13 December 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2260355
26 November 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2248246
27 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014276
20 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014260
13 January 2004
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1993001
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1964313
6 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1741035
18 November 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1707105
18 November 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1707118
17 November 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1706639
27 May 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1623375
20 February 2002
Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1487927
12 October 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 177067
7 March 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 287932
6 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391508
26 February 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1058558
26 January 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439151
22 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 766251
21 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 196991
21 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 440569
21 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279177
31 January 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464907
4 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803088
5 February 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1430641
13 March 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421465
5 February 1997
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1374864
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 April 2016
Resolved
COI is valid for 5 years. COI expired on 05 APR 16. Vessel has been taken out of service and not permitted to operate until the vsl reveives a COI and DDX inspection. Cargo tanks are to remain gas free.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2026
Resolution: VESSEL OOS AND HAS NO COI, SOLD FOR SCRAP OR FLOATING PIER.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 10 September 2015
Resolved
Provide valid and current Certificate of Financial Responsibility (COFR) - 33CFR138.65
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: COFR is valid and current.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 September 2015
Resolved
Proved valid and current Vessel Response Plan (VRP) – 33CFR155.1030
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Vessel has valid and current VRP.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 September 2015
Resolved
Provide current transfer procedures – 33CFR155.720
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2015
Resolution: Vessel provided transfer procedures and PIC list.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 10 September 2015
Resolved
Proved proof of annual cargo relief valve bench testing – 46CFR35.35-70(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Vessel provided proof of annual cargo relief valve bench testing.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 September 2015
Resolved
Proved proof of annual cargo pressure gages calibrations – 46CFR35.35-70(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Vessel has all new cargo pressure gages with all required paperwork.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 September 2015
Resolved
Proved proof of annual cargo pipe testing to 150% the MAWP and properly label cargo pipes with test date and MAWP -33CFR156.170
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Witnessed annual cargo pipe and hose testing to 150%.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 September 2015
Resolved
Proved proof of annual vapor tightness test for VCS/venting lines – 46CFR35.35-70(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: Vessels main header/VCS has been blanked off and taken out of service. Vessel will no longer require it as it will carry only certain D/E cargoes.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 10 September 2015
Resolved
Demonstrate proper operation of all emergency shut downs to cargo pump prime mover – 46CFR32.50-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Witnessed operation of all emergency shut downs on cargo pump prime mover.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 10 September 2015
Resolved
Demonstrate proper operation of all High Level/OverFlow alarms and indicators – 46CFR39.20-9
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Witnessed satisfactory operation of all High Level and Overfill alarms and indicators.
Deck/Cargo › Cargo Heating › General
Issued 10 September 2015
Resolved
Demonstrate proper operation of thermal fluid heater iaw with onboard test procedures – 46CFR61.30-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: Vessel's thermal fluid heater has been blanked off and will no longer be used.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 September 2015
Resolved
Replace all flexible fuel hoses on cargo pump prime mover with USCG Approved J-1942 hoses. 46CFR56.60-25
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: All flexible hoses on cargo pump prime mover have been replaced with approved J-1942 hoses and inspected by attending MI.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 10 September 2015
Resolved
Demonstrate proper operation and test sets (overspeed protection and low lube oil) of thermal fluid heater generator - 46CFR111.12(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: Thermal fluid heater has been blanked off and will no longer be used.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 September 2015
Resolved
Demonstrate proper operation of installed ground detection system – 46CFR111.05-21
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Witnessed proper operation of installed ground detection system.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 10 September 2015
Resolved
Provide proof of High Velocity P/V valve bench testing and proper operation – 46CFR38.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: Main header for vapor contol has been blanked off and is no longer in use.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 September 2015
Resolved
Demonstrate proper operation of required navigation lights – 33CFR81
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Witnessed proper operation of all required navigation lights.
Documentation › Markings/Placards › Warning Signs
Issued 10 September 2015
Resolved
Ensure proper warning lights and signs are posted – 46CFR35.30-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Verified proper warning lights and signs are posted.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 September 2015
Resolved
Identify and repair excessive oil leak in way of exhaust manifold from cargo pump prime mover – 46CFR31.10-17(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: Cargo pump prime mover overhauled and witnessed operational test with no oil leaks.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 September 2015
Resolved
Ensure all on deck electrical boxes for High Level/Over Flow alarms and indicators are proper installed for Class 1 Div 1 standards – 46CFR111.105-3
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2015
Resolution: All on deck electrical boxes are properly installed to Class I Div I standards.
Construction/Loadline › Structures › Deck Plating
Issued 21 April 2015
Resolved
Crop and renew the main deck in four locations IWO the bow rake where the internal diagonals punctured the deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Stiffener
Issued 21 April 2015
Resolved
Crop and renew approximately 15 diagonal frames IWO the bow rake due to excessive deflection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 April 2015
Resolved
Crop and renew the deck longitudinals in approximately 8 locations in the bow rake where sheared IWO the connections with the diagonal frames.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2015
Resolved
Crop and renew the deck transverse beam IWO the #1 chord, port side due to a complete break.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2015
Resolved
Properly repair or crop and renew the bottom transverse beam IWO the #1chord,port side where fractured.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2015
Resolved
Crop and renew the bottom transverse beam IWO the #1 chord, stbd side due to a complete break.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2015
Resolved
Properly repair or crop and renew the bottom transverse beam IWO the #2 chord, stbd side due to a partial fracture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Stiffener
Issued 21 April 2015
Resolved
Properly repair or crop and renew approximately 3 stanchions IWO the #1 chord at their attachment point with the bottom transverse beam due to fractures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Weld
Issued 21 April 2015
Resolved
Properly repair numerous fractured welds throughout the bow rake.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2015
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 April 2015
No resolution recorded
Properly repair or crop and renew approximately 5 bottom longitudinals between the #3 chord and the aft bulkhead of the bow rake due to fractured welds.
Action required: 705 - Other - as specified
Due 21 March 2016 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bracket
Issued 21 April 2015
No resolution recorded
Crop and renew 2 gussets which join the bottom longitudinals to the aft bulkhead on the stbd side of the bow rake due to excessive deflection.
Action required: 705 - Other - as specified
Due 21 March 2016 — due date passed with no resolution recorded
Deck/Cargo › Towing › Towline
Issued 5 March 2015
Resolved
Emergency Towline and towing gear was not installed onboard. required vessel rep to complete installation of emergency towline prior to issuance of load line exemption
Action required: 705 - Other - as specified
Resolved 6 March 2015
Resolution: Attended vessel and witnessed satisfactorily installed towing gear and emergency towline.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 March 2015
Resolved
Discovered stern wrap was full of water due to tank cleaning, and that the bow was filled with approximately 6 inches of water , required vessel rep to pump out the excess water prior to operations.
Action required: 705 - Other - as specified
Resolved 6 March 2015
Resolution: Attended vessel and witnessed minimal water left in both spaces.
Documentation › Markings/Placards › Official Number (US)
Issued 5 March 2015
Resolved
Official number and name were missing from stern of vessel, required vessel rep to stencil name and official number on stern of vessel prior to operations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2015
Resolution: Bayou blue dock QA rep confirmed stenciling of vessel name and official number on stern of vessel via email.
Deck/Cargo › Cargo Heating › General
Issued 2 May 2014
Resolved
In the presence of a USCG Marine Inspector prove proper operation of all alarms and safeties of the Thermal Fluid Heater. Prior to operation of the Thermal Fluid Heater.
Action required: 705 - Other - as specified
Resolved 4 December 2015
Resolution: Not applicable. Thermal fluid heater has been blanked off and is no longer in use.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 May 2009
Resolved
4 hatch covers on wing void hatches have some spots of severe rust and have rusted away metal thats around the gasket to make it water tight. With the rusted away metal, void is not water tight; must be repaired as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 8 June 2009
Resolution: Witnessed sat replacement.
Construction/Loadline › Hull › Side Shell
Issued 29 May 2009
Resolved
Deck knuckle and side shell on starboard side wing void #3 has about a 3' long by 3 1/2" deep smooth inset. Must crop out and renew to orginal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 8 June 2009
Resolution: Wittnessed sat repair.
Deck/Cargo › Cargo Heating › General
Issued 16 July 2007
Resolved
Vessels Thermal fluid heaters internal oil pressure increasing and causing system to burp.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 24 July 2007
Resolution: Thermal fluid heater tested and satisfactory . In compliance with Cfr 46 -61.30-20
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 May 2007
Resolved
Vessel not allowed to use new section of VCS on barge until inspected to meet MSC approved plans by attending inspector.
Action required: 705 - Other - as specified
Resolved 11 December 2007
Operations/Management › Port and Waterways Safety
Issued 1 March 2002
Resolved
Red warning signal (red flag) not painted appropriate color. LEGACY COMPONENT DESC: Warnings Sign
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 4 March 2002
Resolution: Repainted warning sign red.
Documentation
Issued 26 January 2001
Resolved
REVISE TRANSFER PROCEDURES TO INCLUDE OVERFILL DEVICES.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Deck/Cargo
Issued 26 January 2001
Resolved
REPLACE PLASTIC FLAME SCREEN RETAINER RINGS ON FUEL TANK VENTS WITH METAL RETAINERS.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Deck/Cargo
Issued 26 January 2001
Resolved
REPAIR NON-RISING STEM VALVE OPEN/CLOSED POSITION INDICATOR ON #1 PORT CARGO TANK.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW APPROX. 6' OF NO.1 & NO.2 CHANNEL STOCK STIFFENER WITHINTHE NO.6 PORT WING VOID. (LOCATED AFT OF FORWARD BULKHEAD AND DOWN FROM MAIN DECK)
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW APPROX. 10' OF PORT MAIN DECK ROUNDED SHEAR STRAKE, LOCATED 9' AFT OF THE NO.6 PORT WING FORWARD BULKHEAD.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
GRIND AND REWELD 4" CRACK LOCATED 3" BELOW MAIN DECK ON PORT STERN RADIUS CORNER.
Condition: Unknown
Due 9 February 1999
Resolved 9 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW APPROX. 20' OF NO. 1 & NO.2 SIDE SHELL STIFFENERS WITHINTHE NO.6 PORT WING VOID.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW MAIN DECK STIFFENER LOCATED ON PORT SIDE OF FORWARD RAKE.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW NO.2 THRU NO.7 TRIPPING BRACKETS ON BOTTOM LONGITUDINALSLOCATED WITHIN THE FORWARD RAKE, PORT SIDE.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 5 February 1999
Resolved
CROP-OUT AND RENEW APPROX. 3' OF NO.3 & NO.4 BOTTOM LONGITUDINALS FORWARD OF AFT BULKHEAD WITHIN FORWARD RAKE. (3" X 5" X 3') (PORT SIDE OF RAKE)
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999