Records from 1980 to 2005. Most recent: inspection, 20 May 2005.
Inspection history · 66
20 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363103
29 April 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345870
12 March 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2311494
14 December 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2259315
13 September 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2195055
17 June 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2101911
3 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087478
6 February 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2001777
30 January 2004
Deficiency Check · In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1991030
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996741
29 July 2003
ACP COI Oversight
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1832463
14 April 2003
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1762768
22 January 2003
Internal Structural Exam · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1706114
4 November 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1700655
20 October 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1738674
25 September 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1680152
1 July 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1639609
25 February 2002
Inclining Experiment · Deficiency Check · Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1490137
21 February 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1488019
2 November 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1472883
20 June 2001
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1068645
9 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1481300
15 September 2000
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1056181
5 September 2000
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1054559
2 August 2000
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1413787
6 June 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1412130
10 May 2000
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1389130
20 April 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1435073
11 April 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1048751
1 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1046150
28 September 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1376045
14 May 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1468066
25 March 1999
Deficiency Check · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1372506
27 October 1998
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 808819
12 September 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1381334
12 August 1998
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 796344
30 April 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1457556
26 March 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458508
12 February 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1433311
3 November 1997
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1116695
26 June 1997
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1416472
28 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 157144
29 January 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1104683
14 January 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1092270
10 June 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1360536
29 May 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 79411
30 April 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355664
29 April 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 125116
25 May 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1374387
18 April 1995
Initial Construction-Excluding Oversight
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1353697
27 September 1993
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398119
29 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 844035
29 June 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1154234
19 March 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 470
6 August 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1356137
4 December 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936777
19 August 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218253
27 June 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 903206
16 May 1989
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341414
15 October 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1015239
22 September 1986
Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1319088
15 March 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 472981
7 November 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990626
30 September 1985
Credit Drydock · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1293765
1 December 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275933
24 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279377
Operations/Management › Dedicated Clean Ballast Tanks › Preparation
Issued 17 June 2004
Resolved
Provide for review/compliance the Dedicated Clean Ballast Tank operations manual. Vessel shall not conduct cargo operations until review of this manual.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 June 2004
No resolution recorded
Vessel shall conduct Abandon ship and Fire drill prior to leaving port.
Action required: 17 - Rectify deficiencies prior to departure
Lifesaving › Lifeboat
Issued 30 January 2004
Resolved
Repair STBD #3 Lifeboat rudder and propeller blade to as original. Vessel is restricted to 15 total persons until completed. LEGACY COMPONENT DESC: Rudder/Tiller/Steering
Action required: 705 - Other - as specified
Resolved 2 February 2004
Resolution: Made all repairs to as original.
Lifesaving › Lifeboat
Issued 30 January 2004
Resolved
Label #3 and #4 lifeboats with "64 PERSONS" capacity. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 20 August 2004
Lifesaving › Inflatable Liferafts
Issued 30 January 2004
Resolved
Provide non-expired weak links for all life rafts according to manufacturer's instructions and NVIC 1-83 prior to sailing. LEGACY COMPONENT DESC: Weak Link
Action required: 705 - Other - as specified
Resolved 2 February 2004
Resolution: Provided non-expired weak links.
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 January 2004
Resolved
Renew all expired medications for the hospital space prior to sailing from San Diego, CA. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Resolved 4 February 2004
Resolution: Received documentation attesting to fact that expired meds were ordered and received.
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 January 2004
Resolved
Provide clothing lockers and blankets for each berth, one seat, and one table per 46 CFR 92.20-35. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 2 February 2004
Resolution: Provided lockers, blankets, seat, and table.
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 January 2004
Resolved
Provide one mattress missing for berth. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 2 February 2004
Resolution: Provided mattress.
Lifesaving › Lifeboat
Issued 30 January 2004
Resolved
Provide Lifeboat #4 provisions for inspection prior to sailing. LEGACY COMPONENT DESC: Provisions
Action required: 705 - Other - as specified
Resolved 2 February 2004
Resolution: All provisions inspected satisfactorily.
Lifesaving › Lifeboat
Issued 30 January 2004
Resolved
Repair to as original, port aft #4 Lifeboat exterior starboard door handle. LEGACY COMPONENT DESC: Exterior door
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 20 August 2004
Lifesaving › Inflatable Liferafts
Issued 30 January 2004
Resolved
Provide weak link size/capacity labels for all life raft weak links. LEGACY COMPONENT DESC: Weak Link
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 20 August 2004
Lifesaving › Visual Distress Signals (General)
Issued 29 July 2003
Resolved
Properly mark container "distress signals." LEGACY COMPONENT DESC: Marking
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Lifebuoys
Issued 29 July 2003
Resolved
Properly install liferings. LEGACY COMPONENT DESC: Stowage
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Fire Fighting › Fire Hoses › Condition
Issued 29 July 2003
Resolved
Replace failed fire hose.
Due 25 August 2003
Resolved 25 August 2003
Resolution: Removed and replaced.
Fire Fighting › Nozzles › Condition
Issued 29 July 2003
Resolved
Replace leaking fire nozzle.
Due 25 August 2003
Resolved 25 August 2003
Lifesaving › Rescue Boat Equipment
Issued 29 July 2003
Resolved
Provide tow line for rescue boat (either lifeboat 3 or 4).
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Launching Appliances
Issued 29 July 2003
Resolved
Realign forward shiv on lifeboat 1. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Lifeboat Equipment
Issued 29 July 2003
Resolved
Replace three missing liters of water and one parachute rocket for lifeboat 1.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Launching Appliances
Issued 29 July 2003
Resolved
Mouse shackles for lifeboats 1 and 2. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Lifeboat
Issued 29 July 2003
Resolved
Repair lower port forward grab rail bolt on lifeboat 1. LEGACY COMPONENT DESC: Handholds/Handrails
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Launching Appliances
Issued 29 July 2003
Resolved
Replace top two cotter pins for the aft davit on lifeboat 2. LEGACY COMPONENT DESC: Davit
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Lifeboat
Issued 29 July 2003
Resolved
Properly mark call sign on top of lifeboats 3 and 4. LEGACY COMPONENT DESC: Markings
Due 25 September 2003
Resolved 11 September 2003
Lifesaving › Lifeboat Equipment
Issued 29 July 2003
Resolved
Provide missing smoke signals for lifeboats 3 and 4. LEGACY COMPONENT DESC: Buoyant Smoke Signal
Due 25 September 2003
Resolved 11 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 22 April 2003
Resolved
Demonstrate proper operation of cargo pump emergency shutdown devices prior to carrying subchapter D cargoes.
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 17 June 2003
Resolution: Witnessed proper operation.
Electrical
Issued 14 April 2003
Resolved
Remove homemade splitter licated on outlet between auxilliary condensate pump motors.
Due 14 April 2003
Resolved 14 April 2003
Resolution: Removed.
Fire Fighting › Structural - A Class Divisions
Issued 14 April 2003
Resolved
Remove pantry side fusible link plug penetrations and install fusible link on galley side while maintaining the A class boundary in way of the fire shutter. LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Due 14 May 2003
Resolved 22 April 2003
Resolution: penetrations plugged sat.
Construction/Loadline › Structures
Issued 22 January 2003
Resolved
At next drydock make permanent steel repairs to overhead in shelter deck.
LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Due 6 June 2003
Resolved 22 April 2003
Resolution: Repairs made.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 22 January 2003
Resolved
Repair inoperative valve on OPDS#2 LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: Repair made.
Construction/Loadline › Structures
Issued 22 January 2003
Resolved
Repair broken welds at base of stowed anchor bracket (port side forward). LEGACY COMPONENT DESC: Spare Anchor Bracket
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: Repair made.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 22 January 2003
Resolved
Renew/repair dampers on ventilation to forward pump room. LEGACY COMPONENT DESC: Pumproom Ventilation
Condition: Improper/Lack of Maintenance
Due 22 February 2003
Resolved 14 April 2003
Resolution: Renewed.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 22 January 2003
Resolved
Renew mechanical seal on DFM pump (port forward OPDS stores). LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Due 22 February 2003
Resolved 14 April 2003
Resolution: Renewed.
Pollution Prevention/Response › Prevention Equipment
Issued 22 January 2003
Resolved
After completing scheduled maintenance on port and starboard MSDs in shelter deck, provide full technicians report as to condition and operation of systems. (33 CFR 159) LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Due 22 February 2003
Resolved 22 April 2003
Resolution: Proper maintenance and operation of MSD''s conducted and attested to.
Electrical › Electrical Distribution System (service)
Issued 22 January 2003
Resolved
Properly label all circuit breakers with amperage rating and circuit name: bridge breaker box and galley breaker box. (46 CFR 111.40-11) LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 22 February 2003
Resolved 14 April 2003
Resolution: circuit breakers labeled.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 January 2003
Resolved
Install heat shield or lagging on steam lines to winches: port mooring winch and aft mooring winch.
(46 CFR 32.02-15)
LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: installed lagging.
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 January 2003
Resolved
Provide stowage location and properly label location of PFDs on foc'sle for lookout watchstanders.
(46 CFR199.70(b)(2)
LEGACY COMPONENT DESC: Storage
Due 22 February 2003
Resolved 14 April 2003
Resolution: label provided.
Navigation › Piloting/Steering
Issued 22 January 2003
Resolved
Provide updated compass deviation table, major steel work has been conducted since last update.
(46 CFR 32.15-35 & 33 CFR 164.35)
LEGACY COMPONENT DESC: Compass Deviation Table
Due 22 February 2003
Resolved 14 April 2003
Resolution: updated deviation table.
Communications › Internal Communications System
Issued 22 January 2003
Resolved
Prove proper operation of power failure alarms to EOT and rudder angle indictor alarms on bridge.
(46 CFR113.35-5)
LEGACY COMPONENT DESC: Engine Order Telegraph System
Condition: Unknown
Due 22 February 2003
Resolved 22 April 2003
Resolution: Proved operation.
Fire Fighting › Structural - A Class Divisions
Issued 22 January 2003
Resolved
Make galley service line an "A" class fire boundary. Current drop down cage partition is not adequate.
(46 CFR32.57-10)
LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: Provided solid drop down partition.
Electrical › Electrical Distribution System (service)
Issued 22 January 2003
Resolved
Properly enclose electrical junction box above desk in stateroom #4 (bridge deck).
(46 CFR 111.81-1)
LEGACY COMPONENT DESC: Outlet Box
Due 22 February 2003
Resolved 14 April 2003
Resolution: Properly enclosed.
Deck/Cargo › Cargo Stowage
Issued 22 January 2003
Resolved
Complete U. S. Coast Guard inspection of entire cargo block to prior to carriage of Subchapter D cargoes. Cargo authority to be reinstated at satisfactory completion of inspection.
LEGACY COMPONENT DESC: All
Due 22 February 2003
Resolved 22 April 2003
Resolution: completed cargo block inspection.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 January 2003
Resolved
Provide machinery guards on the ships steam turbine generators and the D.O. cold start pump. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: machinery guards provided.
Electrical › Electric Supply System (service)
Issued 22 January 2003
Resolved
Remove dead end cables at numerous locations through out the ship. LEGACY COMPONENT DESC: Cable
Due 22 February 2003
Resolved 14 April 2003
Resolution: cables removed.
Fire Fighting › Structural - A Class Divisions
Issued 22 January 2003
Resolved
Make the emergency escape trunk a "A" boundary. LEGACY COMPONENT DESC: Bulkheads - Evacuation Stations
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: A boundary provided.
Electrical › Lighting (emergency)
Issued 22 January 2003
Resolved
Provide emergency lighting over the boiler control station, steering gear, and lazarette. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: emergency lighting provided.
Electrical › Lighting (emergency)
Issued 22 January 2003
Resolved
Label all the emergency lighting with a red "E". LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: Marked properly.
Engineering
Issued 22 January 2003
Resolved
Identify pipe on starboard reduction gear room in overhead.
Condition: Unknown
Due 22 February 2003
Resolved 14 April 2003
Resolution: Pipe removed.
Engineering › Diesel Engine (auxiliary)
Issued 22 January 2003
Resolved
Renew or repair the hotstarts for the OPDS generator.
Due 22 February 2003
Resolved 22 April 2003
Resolution: Hotstarts renewed.
Electrical
Issued 4 November 2002
Resolved
Properly secure all loose wiring throughout the shelter deck.
Due 4 January 2003
Resolved 22 January 2003
Electrical
Issued 4 November 2002
Resolved
Properly dead end or remove wiring at frame 76 main deck.
Due 4 January 2003
Resolved 22 January 2003
Pollution Prevention/Response
Issued 4 November 2002
Resolved
Fix cap on MSD port in shelter deck.
Due 4 January 2003
Resolved 22 January 2003
Resolution: Item fixed. Additional MSD requirements issued.
Fire Fighting › Structural Fire Protection - General
Issued 4 November 2002
Resolved
Make stuffing tube between fan room and shelter deck firetight. LEGACY COMPONENT DESC: Deckhouse Construction
Due 4 January 2003
Resolved 22 January 2003
Fire Fighting › Structural Fire Protection - General
Issued 4 November 2002
Resolved
Renew wasted area at base of bulkhead between fan room and ladder well to shelter deck. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Due 4 January 2003
Resolved 22 January 2003
Fire Fighting › Structural - A Class Divisions
Issued 4 November 2002
Resolved
Service all fire doors and prove proper closing operation. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 4 January 2003
Resolved 22 January 2003
Deck/Cargo
Issued 2 November 2001
Resolved
Prove proper operation of the remote reach rod for steam supply stripper #2in aft pump room.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: Corrected.
Deck/Cargo
Issued 2 November 2001
Resolved
Properly repair/replace priming valves on main cargo pumpms #2&3 in aft pump room._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Electrical
Issued 2 November 2001
Resolved
Properly repair all lights in all accomodation spaces.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: Corrected.
Documentation
Issued 2 November 2001
Resolved
Safety Radio Telegraph Certificate is expired.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Deck/Cargo
Issued 2 November 2001
Resolved
Prove proper operation of high and high high level alarms for cargo system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 22 January 2003
Resolution: Cargo authority removed, Sub D cargo authority pends completion of PORMS worklist items and full cargo block inspection.
Deck/Cargo
Issued 2 November 2001
Resolved
Remove temp. piping arrangement in aft pumproom leading from aft pump room bilge to machinery space and provide gas tight seal to bulkhead.
Condition: Unknown
Due 25 February 2002
Resolved 25 February 2002
Resolution: Corrected.
Electrical
Issued 2 November 2001
Resolved
Post instructions for aux. diesel generator CO2 system.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: Corrected.
Lifesaving
Issued 2 November 2001
Resolved
Prove proper operation of stbd, aft davit limit switch.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Deck/Cargo
Issued 2 November 2001
Resolved
Replace 90 degree elbow on discharge cargo pump #4. Doubler is not allowedand is leaking.
Condition: Unknown
Due 25 February 2002
Resolved 25 February 2002
Resolution: Corrected.
Deck/Cargo
Issued 2 November 2001
Resolved
Properly replace nut/bolt arrangement for suction strainer for main cargo pump in aft pump room. Nuts do not extend beyond bolt top at all.
Condition: Unknown
Due 25 February 2002
Resolved 25 February 2002
Resolution: Corrected.
Deck/Cargo
Issued 2 November 2001
Resolved
Hydrostaticly test to 1.5 times MAWP, all cargo system conduit on reels, orprovide documentation from USCG proving waiver of such.
Condition: Unknown
Due 25 February 2002
Resolved 25 February 2002
Resolution: Waiver provided
Accommodation/Occupational Safety
Issued 2 November 2001
Resolved
Properly repair bulkhead around door leading out from aft house near firestation #19.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Deck/Cargo
Issued 2 November 2001
Resolved
Repair/renew (fwd pump room) discharge gauge for HFO transfer pump discharge pressure gauge.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: corrected.
Deck/Cargo
Issued 2 November 2001
Resolved
Properly attach pressure sensor for HFO discharge in fwd pumproom. Wire band improper.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: Corrected.
Deck/Cargo
Issued 2 November 2001
Resolved
Repair leak from suction side for gauge sending tube in fwd pump room.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Electrical
Issued 2 November 2001
Resolved
Replace missing glass globes for lighting throughout ship.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Accommodation/Occupational Safety
Issued 2 November 2001
Resolved
Provide proper exhaust duct for new dryer exhaust duct in crew laundry.
Condition: Unknown
Due 17 December 2001
Resolved 25 February 2002
Resolution: Corrected.
Construction/Loadline
Issued 20 June 2001
Resolved
CROP & RENEW INSET ON STEM.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Navigation
Issued 20 June 2001
Resolved
MAKE REPAIRS TO STEERING GEAR PRIOR TO VSL GOING TO SEA UNDER IT'S OWN POWER; PROVIDE PROPOSAL TO OCMI HOUMS FOR TOWING VSL TO SHIPYARD PRIOR TO VSL TRANSITTING THE SHIP CHANNEL.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Unknown
Issued 6 June 2000
Resolved
CONTACT AND SCHEDULE WITH MSO HOUSTON TO CONDUCT INTERNAL STRUCTURAL EXAM OF MACHINERY SPACE DOUBLE BOTTOMS PRIOR TO RECEIVING CREDIT FOR INTERNAL STRUCTURAL EXAM.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 6 June 2000
Resolved
PROVIDE PAST AND CURRENT OIL ANALYSIS REPORTS
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 6 June 2000
Resolved
PROVIDE PAST AND CURRENT TAILSHAFT WEARDOWN READINGS
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 6 June 2000
Resolved
MAKE PERMANENT REPAIRS TO STARBOARD MAIN PROPULSION BOILER AS RELATED TO ITEMS NOTED IN FOSTER-WHEELER TEC REP REPORT DATED 31MAY00 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Construction/Loadline
Issued 6 June 2000
Resolved
CROP AND RENEW TO GOOD METAL FOWARD BULKHEAD AND STARBOARD LONGITUDINAL BULKHEAD IN FORWARD PUMPROOM AT PUMP LEVEL TO THE SATISFACTION OF ATTENDINGMARINE INSPECTOR
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Construction/Loadline
Issued 6 June 2000
Resolved
PROVIDE FORMAL GAUGING REPORT TAKEN FROM CURRENT DRYDOCK
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Electrical
Issued 10 May 2000
Resolved
SERVICE AND PROVE PROPER OPERATION OF BOTH GENERATOR REVERSE POWER RELAYS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Engineering
Issued 10 May 2000
Resolved
REPAIR LEAK ON SUPER HEATER DRAIN VALVE ON PORT BOILER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 2001
Resolved 25 February 2002
Electrical
Issued 10 May 2000
Resolved
LOCATE AND CLEAR GROUND FROM 120 VOLT BUS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Deck/Cargo
Issued 20 April 2000
Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN DEVICES ON ELECTRIC CARGO PUMPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 22 January 2003
Resolution: Cargo authority removed. Sub D cargo authority pends completion of PORMS worklist items and full cargo block inspection.
Electrical
Issued 20 April 2000
Resolved
PROVIDE COVER FOR LIGHT IN HOSPITAL HEAD AND PROVIDE FOR GENERAL CLEANING OF THE SPACE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Construction/Loadline
Issued 20 April 2000
Resolved
PROVIDE PROPER INSTALLATION OF ENGINE ROOM/MACHINERY SPACE BILGE ALARM ELECTRICAL WIRING. WIRING CURRENTLY SUPPORTED BY PLASTIC WIRE TIES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Lifesaving
Issued 20 April 2000
Resolved
RENEW FALLS ON PORT AND STARBOARD FORWARD LIFEBOAT DAVITS AND END FOR END FALLS ON AFT LIFEBOAT DAVITS. WEIGHT TEST ALL LIFEBOAT DAVITS IN THE PRESCENCE OF A CG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Engineering
Issued 20 April 2000
Resolved
REPAIR FUEL LEAK AT FLANGE ON FUEL OIL REGULATING LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 25 February 2002
Resolution: Corrected
Navigation
Issued 20 April 2000
Resolved
PROVIDE UPDATED CHARTS HOUSTON/GALVESTON AREA PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Deck/Cargo
Issued 20 April 2000
Resolved
HYDROSTATICALLY TEST FIXED CARGO LINES TO 1.5 TIMES MAWP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 22 January 2003
Resolution: Cargo authority removed. Sub D cargo authority pends completion of PORMS worklist items and full cargo block inspection.
Deck/Cargo
Issued 20 April 2000
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 22 January 2003
Resolution: Cargo authority removed. Sub D cargo authority pends completion of PORMS worklist items and full cargo block inspection.
Deck/Cargo
Issued 20 April 2000
Resolved
PROVE PROPER OPERATION OF THE ODME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 22 January 2003
Construction/Loadline
Issued 20 April 2000
Resolved
PROVIDE DEDICATED CLEAN BALLAST OPERATIONS MANUAL IAW 33CFR157._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 25 February 2002
Electrical
Issued 20 April 2000
Resolved
PROPERLY SEAL WIRE FROM CARGO TANK DEHUMIDIFIER AT AFT JUNCTION BOX. ENSUREWATER TIGHTNESS OF JUNCTION BOX AND PROVIDE METAL FASTENERS OF WIRE TO CABLE RUNS/TRAY AT THE HUMIDIFIER._x001C_ _x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Electrical
Issued 20 April 2000
Resolved
REPLACE FRAYED WIRE TO EMERGENCY EMBARCATION LIGHT AT STARBOARD AFT LIFEBOAT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 25 February 2002
Resolution: corrected
Electrical
Issued 20 April 2000
Resolved
PRIOR TO DEPARTING, CONDUCT SATISFACTORY TEST OF BOTH STEAM TURBINE GENERATOR OVERSPEED SAFETIES AND REVERSE POWER RELAYS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Lifesaving
Issued 20 April 2000
Resolved
PROVIDE 2 PORTABLE 02 AND FLAMMABLE GAS DETECTORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Fire Fighting
Issued 20 April 2000
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Fire Fighting
Issued 20 April 2000
Resolved
FREE UP HOSE REEL TO FIRE STATION #28.
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Fire Fighting
Issued 20 April 2000
Resolved
REPAIR VALVE AT #2 FIRE HOSE STATION AND PROVE PROPER OPERATION OF ALL OHTER STATIONS PRIOR TO SAILING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Engineering
Issued 20 April 2000
Resolved
PRIOR TO DEPARTING, CONDUCT SATISFACTORY TESTS OF THE BOILER SAFETY RELIEF VALVES AND BOILER AUTOMATION PROCEDURES 46 CFR 61.05-10._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 2001
Resolved 15 May 2000
Lifesaving
Issued 11 April 2000
Resolved
Renew forward lifeboat falls and weight test forward and aft lifeboat fallsat drydocking NLT 25 May 2000. 46 CFR 199.190(i)&(j).
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Lifesaving
Issued 1 March 2000
Resolved
RENEW FALLS AND WEIGHT TEST FORWARD LIFEBOATS AT COI NLT 30APR00._x001C_ 46CFR199.190(i)@(j)
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Navigation
Issued 14 May 1999
Resolved
Provide steering gear instructions in the engine room as per 46 CFR 35.40- 30.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Replace starboard forward lifeboat rudder as per 46 CFR 199.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Engineering
Issued 14 May 1999
Resolved
Repair and prove operation of DFM deep well pump on focsle weather deck. Current air diaphram pump is a temporary arrangement only as per 31.10- 17(e).
Condition: Unknown
Due 30 April 2001
Resolved 25 February 2002
Electrical
Issued 25 March 1999
Resolved
Due to recent installation of (2) steam turbogenerators, prove proper operation of mechanical and electrical trips for both turbogenerators priorto getting underway; 46 CFR 50.20-35, 46 CFR 50.05-10(a).
Condition: Unknown
Due 30 April 2001
Resolved 29 March 1999
Engineering
Issued 25 March 1999
Resolved
Repair, replace, or address bent stay in way of port boiler outboard burnerin double casing. Third party evaluation of stay is acceptable; 46 CFR 50.20-35.
Condition: Unknown
Due 30 April 2001
Resolved 31 March 1999
Engineering
Issued 25 March 1999
Resolved
Repair casing and stay (cracked welds) on STBD boiler on inboard after corner on front wall; 46 CFR 52.01-40._x001C_ _x001C_
Condition: Unknown
Due 30 April 2001
Resolved 31 March 1999
Engineering
Issued 25 March 1999
Resolved
Provide documentation from the boiler manufacturer (Foster Wheeler) addressing the warped STBD boiler transverse I-beam frame in way of the burner registers. Warpage on frame does not represent normal boiler service; 46 CFR 52.01-40._x001C_
Condition: Unknown
Due 30 April 2001
Resolved 29 March 1999
Accommodation/Occupational Safety
Issued 25 March 1999
Resolved
Provide approved plans for installation of replacement Turbogenerators 1 and 2.
Condition: Unknown
Due 30 April 2001
Resolved 25 February 2002
Resolution: Corrected.
Deck/Cargo
Issued 10 June 1996
Resolved
REPAIR/REPLACE THE FOLLOWING IG SYSTEM VALVES. 1. MAIN CIRC VALVE, 2. RECIRC VALVE, 3. #1 & #2 BLOWER INLET AND OUTLET VALVES. PROVE EACH VALVE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Deck/Cargo
Issued 10 June 1996
Resolved
REPAIR/REPLACE LOW LEVEL TO DECK SEAL ALARM AND PROVE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Deck/Cargo
Issued 10 June 1996
Resolved
MAKE REPAIRS/REPLACE #1 AND #2 IG SYSTEM BLOWERS AND PROVE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Documentation
Issued 30 April 1996
Resolved
SUBMIT TO LOCAL [name withheld] FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Unknown
Issued 30 April 1996
Resolved
PROVIDE ASME REPORT ON INSTALLED PRESSURE VESSELS INWAY OF OPDS SPACE.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Deck/Cargo
Issued 30 April 1996
Resolved
PROVE IG SYSTEM TO INCLUDE ALL SHUTDOWNS, PNEUMATIC VALVES, CONTOL PANELS, O2 ANAYLZER, ETC.
Condition: Unknown
Due 24 July 1996
Resolved 23 July 1996
Electrical
Issued 30 April 1996
Resolved
PROVIDE INDICATOR GUAGE FOR EMERGENCY GENERATOR FUEL TANK.
Condition: Unknown
Due 15 June 1996
Resolved 24 June 1996
Fire Fighting
Issued 30 April 1996
Resolved
PROVIDE TO LOCAL OCMI THE FLOW TEST DATA AND FOAM SYSTEM MANUAL REQUIRED BYCOMMENT (5), MARINE SAFETY CENTER, LTR: E1-9600136, DTD: 07FEB96
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Electrical
Issued 30 April 1996
Resolved
PROVE REVERSE POWER RELAY TO SSDG AFTER INSTALLATION TO REPLACE TEMPORARY TRIP INSTALLED
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Deck/Cargo
Issued 30 April 1996
Resolved
PROVE ALL CARGO STRIPPING PUMPS INWAY OF FORWARD AND AFTER PUMPROOMS. STEAM PIPING TO ALL PUMPS WAS WASTED/HOLED IN VARIOUS AREA'S, INCLUDING SUPPLY HEAD MANIFOLD'S.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Accommodation/Occupational Safety
Issued 30 April 1996
Resolved
MAKE REPAIRS AND PROVE OPERATION OF DISHWASHER INWAY OF CREWS GALLEY.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Unknown
Issued 30 April 1996
Resolved
COMPLETE REPAIRS AS NEEDED TO ALL VENT DUCTING INWAY OF FORWARD AND AFTER PUMPROOMS.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Documentation
Issued 30 April 1996
Resolved
PROVIDE CLASS APPROVED IGS MANUAL TO LOCAL OCMI.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Deck/Cargo
Issued 30 April 1996
Resolved
PROVE ALL CARGO PUMPS AND OPDS PUMPS SHUTDOWNS
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Unknown
Issued 30 April 1996
Resolved
PROVIDE A DIVERTER SHIELD TO OVERBOARD DISCHARGE PORTSIDE BELOW FORWARD LIFEBOAT.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Construction/Loadline
Issued 25 May 1995
Resolved
IN AFT PEAK TANK, CLEAN BILGE SUCTION STRAINER PRIOR TO ACTIVATION.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Construction/Loadline
Issued 25 May 1995
Resolved
PROVIDE COGNIZANT OCMI A COPY OF ALL HULL GAUGING REPORTS.
Condition: Unknown
Due 30 May 1995
Resolved 18 September 1995
Construction/Loadline
Issued 25 May 1995
Resolved
IN THE AFT PEAK TANK, FREE ALL LIMBER HOLES PRIOR TO ACTIVATION.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Engineering
Issued 25 May 1995
Resolved
PROVIDE THE COGNIZANT OCMI A COPY OF THE STERN TUBE LUBE OIL ANALYSIS AS DOCUMENTATION FOR NOT DRAWING THE TAILSHAFT PRIOR TO ACTIVATION.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 6 August 1992
Resolved
THE 150 FT LENGTHS OF FIRE HOSES LOCATED AT FIRE STATIONS #18 AND #19 MUST BE MANUFACTURED AS SUCH AND NOT TWO 75 FT LENGTHS ATTACHED TOGETHER.
Condition: Unknown
Due 7 August 1992
Resolved 7 August 1992
Lifesaving
Issued 6 August 1992
Resolved
CONDUCT WEIGHT TESTS FOR ALL LIFEBOAT DAVITS AND FALLS PRIOR TO VESSELS OPERATION.
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Unknown
Issued 19 August 1989
Resolved
VESSEL MUST COMPLY WITH THE REQUIREMENTS OF 33 CFR 157 PRIOR TO OPERATION AND NOT LATER THAN 19 AUGUST 1991.
Condition: Unknown
Due 19 August 1989
Resolved 19 August 1989
Deck/Cargo
Issued 30 September 1985
Resolved
CARGO LEVEL INDICATOR PANEL LOCATION IN SHELTER DECK IS NOT EXPLOSION PROOFOR INTRINSICALLY SAFE AND MUST BE REMOVED.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985
Resolved
RENEW EXPANSION JOINT ON AFT FIRE PUMP.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Electrical
Issued 30 September 1985
Resolved
MAKE OPERABLE THE INTAKE LOUVERS FOR THE EMERGENCY GENERATOR ROOM TO BE AUTOMATICALLY CONTROLLED UPON ENGINE START UP.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Electrical
Issued 30 September 1985
Resolved
MAKE OPERABLE "WRONG DIRECTION ALARM" AND REMOVE ON/OFF SWITCH (AT THE THROTTLES).
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985
Resolved
RENEW ALL LEAKING FIRE STATION HYDRANTS AS NEEDED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985
Resolved
SUBMIT FOR APPROVAL A FIRE CONTROL KEY PLAN.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985
Resolved
PROVIDE A WEATHERTIGHT ENCLOSURE ON THE WEATHER DECK TO STORE A DUPLICATE SET OF FIRE PLANS. THIS ENCLOSURE MUST BE PERMANENTLY MARKED.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Deck/Cargo
Issued 30 September 1985
Resolved
PERMANENTLY MARK THE EMERGENCY CARGO PUMP SHUT OFF VALVE.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Construction/Loadline
Issued 30 September 1985
Resolved
PROVIDE A MEANS OF CLOSURE ON THE FOREPEAK VENT AND THE FORWARD DEEP BALLAST TANK VENT ON THE FOCS'L DECK PRIOR TO CARGO VOYAGE.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Fire Fighting
Issued 30 September 1985
Resolved
REMOVE NON-EXPLOSION PROOF GENERAL ALARM BELL FROM SHELTER DECK PRIOR TO LOADING CARGO. REPLACE WITH AN EXPLOSION PROOF BELL.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985