Records from 1983 to 2011. Most recent: inspection, 14 February 2011.
Inspection history · 118
14 February 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3945221
5 February 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3942669
7 December 2010
ISM Oversight · ACP Periodic Oversight
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3906399
3 December 2010
Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3903634
24 October 2010
Type not recorded
No type recorded · Activities Europe · Activity 3876950
24 September 2010
Type not recorded
No type recorded · Activities Europe · Activity 3868049
30 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3685160
29 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3549611
28 July 2009
ACP Annual Oversight
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3542938
5 December 2008
MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3375178
4 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3374123
7 March 2008
COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 3153655
17 January 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3327426
16 July 2007
MTSA/ISPS Verification · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2996905
31 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2731466
19 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2718389
11 May 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2646868
1 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2638029
27 April 2006
MTSA Verification · Ballast Water Examination · ACP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2635139
25 April 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2637631
29 March 2006
Damage Survey
Physical examination · Activities Europe · Activity 2611661
23 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539736
30 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2479389
6 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2416622
3 May 2005
Ballast Water Examination · ACP Annual Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2344800
29 April 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2352805
13 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2333340
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2127435
31 August 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2190624
23 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2043741
21 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2049633
20 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2049050
20 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2050006
19 April 2004
ACP COI Oversight
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2047351
24 December 2003
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1969105
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972218
19 September 2003
In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1908126
18 March 2003
Cargo Tank Internal · MARPOL Annex V Examination · Internal Structural Exam · ACP COI Oversight · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1903851
24 February 2003
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1746275
19 January 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1907232
24 April 2002
Annual Inspection · ACP COI Oversight
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1608767
18 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 153499
10 April 2001
Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1395684
10 March 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1446888
19 January 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 666604
8 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 18890
8 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 214489
13 May 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460301
1 April 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 148302
1 April 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461128
8 January 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 809673
19 August 1998
Hull Examination
Physical examination · Activities Europe · Activity 1408149
27 May 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1364746
15 May 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390773
1 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770768
26 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196858
24 November 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 222276
3 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 166910
3 August 1997
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1117313
1 August 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392742
28 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 157144
12 July 1996
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1089024
9 July 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1442422
7 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21459
4 December 1995
Hull Examination
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 875314
23 August 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404000
7 July 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 137022
10 June 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1188170
2 June 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 73078
11 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 57098
19 August 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416029
29 September 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848763
13 September 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834664
19 August 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158946
17 August 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134469
20 May 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362771
30 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 215624
30 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 221462
20 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354532
19 November 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2033
3 September 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1244976
16 July 1992
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 958388
13 July 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 951467
8 July 1991
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933075
19 April 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 900166
30 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932977
10 November 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931830
29 October 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933089
13 September 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1222997
8 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904547
11 July 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1224208
29 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222867
24 May 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928360
1 September 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352548
24 July 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038361
24 May 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 897424
11 May 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 462571
26 October 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199091
22 September 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1043679
21 August 1988
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349770
18 March 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1336590
24 February 1988
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332260
15 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329732
21 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010829
15 July 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1325213
21 May 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332902
13 May 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1331515
13 February 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311763
28 May 1986
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1297708
26 October 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294526
5 October 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 515745
28 April 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 983623
8 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976877
18 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974367
23 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283174
6 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281871
5 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281870
17 February 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278271
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 July 2006
Resolved
Vessel primary and secondary radars occasionally trip off. Vessel is required to have a technician report and follow up examination prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2006
Resolution: Recieved technician report regarding radars. Report states, radars are working properly. 4AUG06
Engineering › Bilge Water Management System › Valve
Issued 27 April 2006
Resolved
Wasted Fire Pump/Ballst discharge valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2006
Resolved 11 May 2006
Resolution: Cleared by class (ABS) report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 March 2006
Resolved
The tanker's 3 CM X-band radar is inoperable.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 21 April 2004
Resolved
Overseas Marilyn to prove in writing to this office that atleast two persons of the engineer watch are physically in the machinery control space during restricted navigation of the Mississippi. 33CFR165.810(f)(1) One of which must consist of a licensed engineer.
Due 28 April 2004
Resolved 28 April 2004
Resolution: Received class survey from ABS and letter from Chief Engineer.
Engineering
Issued 10 April 2001
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR OR ABS SURVEYOR. VESSEL IS RESTRICTED TO DOMESTIC VOYAGES ( AND MUST RETAIN ALL OILY WASTES ) UNTIL PROPER OPERATIONOF THE OWS IS PROVEN.
Condition: Unknown
Due 10 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 13 May 1999
Resolved
Replace the following natural air vents on bow. Starboard side going to focs'l locker, port side to focs'l locker and port side to forepeak tanks.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 13 May 1999
Resolved
Replace retrotape on bottom on lifeboats.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 13 May 1999
Resolved
Make repairs to emergency generator space louvers. Demonstrate proper operation.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Electrical
Issued 13 May 1999
Resolved
Provide approved switchboard mat for in front of control room switchboard.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 13 May 1999
Resolved
Repair the following CO2 discharge lines. #4 hold forward discharge into hold, #2 hold both vents into hold, #5 hold forward vent line where rusted through in way of hold injection pipe.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Navigation
Issued 13 May 1999
Resolved
Prove proper operation of buzzer alarm on navigation light panel. Alarm sounds when light or fuse is out and inoperable.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Engineering
Issued 9 July 1996
Resolved
TEST & LOG SETTING OF ECONOMIZER SAFETY VALVE.
Condition: Unknown
Due 9 August 1996
Resolved 11 July 1996
Lifesaving
Issued 9 July 1996
Resolved
CONDUCT WEIGHT TEST ON PORT LIFEBOAT.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Electrical
Issued 9 July 1996
Resolved
PROVE OPERATION OF LOW LUBE OIL SHUTDOWN OF EMERGENCY GENERATOR.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Electrical
Issued 9 July 1996
Resolved
PROVE OPERATION OF LOW LUB OIL SHUTDOWN ON #1 SSDG.
Condition: Unknown
Due 9 July 1996
Resolved 9 July 1996
Engineering
Issued 4 December 1995
Resolved
WHILE AT SEA, TEST AND SET ECONOMIZER SAFETY VALVE. FAX RESULTS TO MIO EUROPE. INCLUDE: TIME, DATE, LIFTING PRESSURE, RE-SEATING PRESSURE, CHIEFENG'S SIGNATURE, MASTER'S SIGNATURE AND STAMP.
Condition: Unknown
Due 4 January 1996
Resolved 11 December 1995
Lifesaving
Issued 23 August 1995
Resolved
CONDUCT WEIGHT TEST PORT AND STBD LIFEBOATS IN PRESENCE OF MARINE INSPECTOR. THE ABOVE REQUIREMENT IS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] NLT 31OCT95.
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 29 September 1993
Resolved
PROVIDE APPROVED PLANS FOR THE INSTALLED FIXED C02 SYSTEM.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Fire Fighting
Issued 29 September 1993
Resolved
PROVIDE APPROVED FIRE PLAN FOR THE ENGINEROOM PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Engineering
Issued 13 July 1992
Resolved
SET AND LOG PRESSURE OF WASTE HEAT BOILER SAFETY VALVE, HAVE MARINE INSPECTOR SEAL AT NEXT AVAILABLE U. S. PORT.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Accommodation/Occupational Safety
Issued 13 July 1992
Resolved
REPAIR AND OR REMOVE AIR COMPRESSOR AND AIR RECIEVER AS SOON AS POSIBLE BUTNO LATER THAN 31 AUG 1993.
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Lifesaving
Issued 8 September 1990
Resolved
PROVE PROPER OPERATION OF STARBOARD LIFEBOAT WINCH CLUTCH AND BRAKE. SEE 46 CFR 94.35 (B)(4)(I),(II) AND (III).
Condition: Unknown
Due 8 September 1990
Resolved 8 September 1990
Lifesaving
Issued 11 July 1990
Resolved
OPEN LIMIT SWITCHES AND CONTROLLERS FOR INSPECTION. (STARBOARD LIFEBOAT ONLY).
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Electrical
Issued 11 July 1990
Resolved
REMOVE PLASTIC TIE STRAPS IAW IEEE THROUGHOUT THE VESSEL. SPECIFICALLY, LIFEBOAT LIMIT SWITCHES AND DRY STORES AREA.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Engineering
Issued 11 July 1990
Resolved
CONDUCT TEST OF OVERSPEED TRIP ON MAIN ENGINE AND PLACE RESULTS IN MACHINERY LOG. CUBMIT OVERSPEED TRIP RPM TO [name withheld].
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Engineering
Issued 11 July 1990
Resolved
TEST AUXILLARY WASTE HEAT BOILER SAFETY VALVE AND LOG RESULTS IN MACHINERY LOG.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Lifesaving
Issued 11 July 1990
Resolved
WEIGHT TEST STARBOARD LIFEBOAT AT NEXT U.S. PORT IN PRESENCE OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Construction/Loadline
Issued 11 July 1990
Resolved
REPAIR HOLED HANDRAIL ON STRABOARD FORECASTLE.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Electrical
Issued 11 July 1990
Resolved
PROVE PROPER OPERATION OF THE HIGH JACKET WATER TEMPERATURE ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Construction/Loadline
Issued 11 July 1990
Resolved
REPAIR HOLED HANDRAIL ON FORECASTLE ACCESS LADDER.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Deck/Cargo
Issued 24 May 1990
Resolved
MAKE PERMANENT REPAIRS TO SUCTION PIPING FOR THE OILY WATER SEPERATOR. THIS ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] LATER THAN 14JUL90.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Electrical
Issued 24 July 1989
Resolved
REPAIR TWO INOPERATIVE GENERAL ALARM BELLS; ONE LOCATED IN MAIN DECK STARBOARD SIDE PASSAGEWAY, ONE LOCATED IN "B" DECK ATHWARTSHIPS PASSAGEWAY.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Lifesaving
Issued 24 July 1989
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO LEAVING PORT.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Fire Fighting
Issued 21 August 1988
Resolved
CONDUCT HYDRO TEST ON BOTH LARGE SCUBA BOTTLES.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Engineering
Issued 21 August 1988
Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIP, LOW LUBRICATING OIL PRESSURE AND HIGH JACKET WATER TEMPERATURE ALARMS/TRIP ON THE MAIN ENGINE.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Fire Fighting
Issued 21 August 1988
Resolved
CO-LOCATE FIREHOUSE BOXES WITH APPROPRIATE FIRE HYDRANTS AT STATIONS 8,9,1820,21 & 23.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Fire Fighting
Issued 21 August 1988
Resolved
HAVE QUALIFIED SERVICE REPS INSTALL KIDDE FLEX LOOPS FOR CARGO HOLD DELAYEDRESERVE BANK OF CYLINDERS. PRIOR TO DEPARTURE LISNAVE, FLEX LOOPS OR GAS TIGHT SOLID PLUGS MUST BE INSTALLED. IN ANY CASE, FLEX LOOPS MUST BE INSTALLED PRIOR TO LOADING ANY CARGO.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Lifesaving
Issued 21 August 1988
Resolved
MODIFY INSTALLATION OF L/B DAVIT LIMIT SWITCHES SO THAT ONCE ACTIVATED, SWITCH REMAINS ACTIVATED UNTIL DAVIT IS LOWERED BELOW ACTIVATION POINT.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Electrical
Issued 21 August 1988
Resolved
PROVE PROPER OPERATION OF JACKET WATER SENSORS ON THE NUMBER 1 SHIP SERVICE GENERATOR AND THE EMERGENCY GENERATOR.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Lifesaving
Issued 21 August 1988
Resolved
REPORT RESULTS OF FIRE AND BOAT DRILLS CONDUCTED WITHIN 24 HOURS OF DEPARTURE LISNAVE.
Condition: Unknown
Due 21 August 1988
Resolved 21 August 1988
Deck/Cargo
Issued 21 May 1987
Resolved
THE NEW DECK AIR RECEIVER, SERIAL #D-9150, IS NOT TO BE USED UNTIL THE PROPER DOCUMENTATION IS SUBMITTED AS PER 46 CFR 54.01-5(E). A HYDROSTATIC TEST AT 150% OF THE MAXIMUM ALLOWABLE WORKING PRESSURE MUST BE COMPLETED PRIOR TO THE TANK BEING STAMPED BY A MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Accommodation/Occupational Safety
Issued 13 February 1987
Resolved
TEST ECONOMIZER (WASTE HEAT BOILER) SAFETY RELIEF VALVE IN PLACE. VALVE ISTO RELIEVE AT NO MORE THAN 135 PSI. SUBMIT WRITTEN AFFIDAVIT TO [name withheld], TEXAS DESCRIBING TEST RESULTS.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Construction/Loadline
Issued 23 October 1984
Resolved
CROP AND RENEW THREE (3) FORWARD FRAMES AND THE DAMAGED ADJACENT BULKHEAD ON THE PORT SIDE IN THE NO. 3 CARGO HOLD.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984
Construction/Loadline
Issued 23 October 1984
Resolved
PERMANENTLY REPAIR THE FRACTURED SEAM ON THE PORT SIDE, AFTER BULKHEAD IN THE NO. 2 CARGO HOLD.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984
Construction/Loadline
Issued 23 October 1984
Resolved
PERMANENTLY REPAIR THE FRACTURED SEAM ON FRAMES 131, 132, AND 133 IN THE NO. 3 CARGO HOLD.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984
Construction/Loadline
Issued 23 October 1984
Resolved
RENEW THE SIDE SHELL AS NECESSARY BETWEEN FRAMES 132 THROUGH 134.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984