Records from 2010 to 2026. Most recent: inspection, 12 January 2026.
Inspection history · 91
12 January 2026
Annual Inspection · Deficiency Check · MSP Select Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8293833
24 November 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8273172
3 April 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8104890
20 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8096958
15 March 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8096686
24 October 2024
MSP COI Oversight · MTSA/ISPS Verification · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8031432
30 August 2024
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7992587
26 August 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7989713
1 August 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7971991
14 May 2024
Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7912127
4 March 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7873509
26 February 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7871173
21 February 2024
MSP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7862514
20 February 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7990464
26 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7842458
19 December 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7840675
30 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7831821
29 November 2023
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7837664
27 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7830064
22 August 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7774151
10 August 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7764969
26 July 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7752560
14 June 2023
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7714971
17 May 2023
Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 7691089
2 May 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7679236
1 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7662819
30 March 2023
MTSA/ISPS Verification · MSP Periodic Oversight · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7625665
27 January 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7627869
26 January 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7648889
25 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627288
18 January 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7623077
18 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7623104
20 December 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7611233
4 December 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7604110
24 November 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7599237
8 November 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7591465
8 November 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7591474
8 November 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7591486
2 September 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7558168
12 August 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7531545
8 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7528414
13 July 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7505650
11 June 2022
Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7476375
11 May 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7448569
25 April 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7437384
1 March 2022
Annual Inspection · Deficiency Check · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7404011
31 January 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7388053
26 January 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7385776
23 January 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7384724
21 January 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7383830
10 August 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7282381
30 July 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7272697
23 July 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7265538
4 June 2021
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7215230
18 May 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7218250
13 March 2021
Type not recorded
No type recorded · Activities Europe · Activity 7164487
4 February 2021
Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7134282
31 January 2021
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7133537
30 January 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7137886
27 October 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7084916
27 October 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7084959
4 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7050111
3 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7055886
30 August 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7047713
2 March 2020
Type not recorded
No type recorded · Activities Europe · Activity 6922818
10 January 2020
COI Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6886734
7 January 2019
MSP Annual Oversight · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6605508
13 December 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6598707
26 November 2018
ACP Additional Oversight – Risk Assessment
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6586947
24 September 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547194
29 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6596085
27 February 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6362431
6 February 2018
MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6342722
29 January 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6343684
14 December 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6324224
14 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6240366
18 May 2017
Type not recorded
No type recorded · Activities Europe · Activity 6149898
7 February 2017
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6083778
25 October 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6029773
13 September 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5999453
29 August 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5986089
14 June 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5908658
7 June 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5900363
31 March 2016
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5844147
18 March 2016
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5835738
9 March 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5829722
2 March 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5825215
25 February 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5821560
30 January 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5816150
21 January 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5801308
20 January 2016
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5908564
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 January 2026
Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. LPCO2 Instruction Manual and posted instructions state that the stop valve should normally be open. Inspectors discovered the valve in the closed position. Vessel's crew stated they normally keep this valve closed and there is a small placard at the fire control station instructing the crew to open the valve. 74 SOLAS (97) II-2/21 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2026
Resolution: Stop valve opened SMS updated to reflect keeping valve open
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 January 2026
Resolved
Any required fixed fire detection and fire alarm system with manually. Inspectors discovered that fire panel for loop eight was in fault. In addition numerous smoke detectors were missing their covers in the cargo spaces and above the #3 generator. 74 SOLAS (97) II-2/13.1.1 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 14 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the
service for which they are intended and shall be so installed and protected as to reduce to a minimum reduce to a minimum any danger to persons on board. Inspectors noticed #5 generator oil leaks on governor and main rear seal. 74 SOLAS (04) II-1/26.1 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 14 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 November 2025
Resolved
Each cargo vessel must carry at least one rescue boat. Vessel self reported their fast rescue boat main shaft bearing failed, class notified, sourcing parts.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2025
Resolved 26 November 2025
Resolution: Recevied satisfactory class report attesting to the repair.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 22 November 2024
Resolved
MI found that the stern door was secured and watertight when closed but vessel's crew was unable to properly secure the door with locking pins on the port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2025
Resolved 4 February 2025
Resolution: Vessel has provided evidence of repairs to the vessel’s cargo door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
The main engine's electronic control from bridge and engine control room is inoperative. Only local control of engine remains. Provide report from recognized organization providing analysis of the cause of failure and statement regarding fitness for service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Vessels engine controls were repaired, class report attached
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 13 July 2022
Resolved
Vessel will sail short 1 x Oiler as required by COI. Master states crew member has quit for personal reasons and company will be unable to fill position prior to scheduled departure of 17JUL.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2022
Resolved 9 August 2022
Resolution: A replacement for this oiler position was provided onboard during the port call in Corpus Christi, Texas on 8/1/22. However, the day prior (7/31/22), it is reported than 2 other oilers departed the vessel. New 835 issued on 8/9/22 by MSU Port Arthur.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 May 2022
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should ensure that each ship is: manned with qualified, certificated, and medically-fit seafarers in accordance with national and international requirements.
The vessel is currently short 3 of the required crew , 2 ABs and 1 Oiler, as specified on the Certificate of Inspection. Additionally, 1 of the 2 ABs currently missing from the crew, has been missing since 25 April.
The company is to conduct an internal investigation into their processes regarding their obligations under US law and the ISM Code, to ensure the safe manning of the vessel. Complete internal investigation and develop corrective actions within 90-days, have ready for RO review at the next annual verification of the DOC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 August 2022
Resolution: CVC rep in attendance at DOC audit confirmed satisfaction of deficiency as witnessed by ABS Lead Auditor. Audit report still pends.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 18 March 2022
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. STBD side embarkation ladder showing signs of dry rot and/or deterioration at the eye splice.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2022
Resolved 8 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 June 2021
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under §164.35(a), a second marine radar system that operates independently of the first. Vessel's 9 GHz (S-band) radar inoperable.
33 CFR 167.37(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2021
Resolution: Deficiency Cleared by ACS/RO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2021
Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operating at full power in all weather conditions including heavy weather, an adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of the machinery. Any other machinery space shall be adequately ventilated appropriate for the purpose of that machinery space.
The PLC cabinet, inboard side, within the reefer container transformer room, overheats in hot ambient conditions and needs the cabinet doors open with a fan blowing in to keep the equipment operating. Crew placed welded/cardboard covers over original ventilation ports and installed a temporary flexible ventilation system to directly discharge on PLC cabinet.
74 SOLAS (04) II-1/35
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 1 March 2021
Resolution: DNV-GL Class Report 1555940-1 acceptance as Condition of Class. The ventilation arrangement for the PLC cabinet is to be improved using additional cabinet exhaust and room cooling to keep the cabinet closed at all times.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 4 February 2021
Resolved
Except as specified in paragraph 3 of this regulation, any ships of 10,000 gross tonnage nd above shall be
fitted with oil filtering equipment complying with paragraph 7 of this regulation.
OWS circulation pump/motor unit failed while conducting OWS testing, thus rendering the unit unusable.
MARPOL I/14.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 26 February 2021
Resolution: Received DNV-GL Class report 1555940-1 attesting to the crew reconditioned the pump and motor. Operational testing found good.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 February 2021
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
Emergency switchboard 220V system has a ground on the L1 phase.
74 SOLAS (04) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 26 February 2021
Resolution: Received DNV-GL Class report 1555940-1 attesting to the crew isolated the low insulation in 1EF204 deck lighting distribution circuit, repaired and tested good.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2021
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
3 sensors on the lube oil filter and 2 in the pipe tunnel have the main cable pulled out from the base, exposing the internal wires.
74 SOLAS (04) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 26 February 2021
Resolution: Received DNV-GL Class report 1555940-1 attesting to the crew repaired all loose cable glands.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 4 February 2021
Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom.
Notated multiple waste storage bins were constructed of combustible materials on upper weather deck between superstructure and open deck.
74 SOLAS (97) II-2/18.5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 26 February 2021
Resolution: DNV-GL Class Report 1555940-1 acceptance as Condition of Class. "The combustible waste storage bins on weatherdeck are to be replaced with non-combustible materials, unless they are suitably marked for carriage of wet waste, glass bottles and metal cans.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 February 2021
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be prescribed in tables 44.1 and 44.2.
Structural fire protection in battery room and paint locker severely deteriorated, not in compliance with fire ratings required by table 44.1.
74 SOLAS (97) II-2/44.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 26 February 2021
Resolution: Received DNV-GL Class Report 1555940-1 attesting to the boundary insulation at the lower portion of battery room, paint locker and CO2 room bulkheads were all repaired/renewed and fastened
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 25 October 2016
Resolved
AB [name withheld] (Mariner ref# [withheld]) missing MMC at last port of call.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 26 October 2016
Resolution: National Maritime Center issued a duplicate MMC and will FEDEX to the company.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 March 2016
Resolved
Fixed fire detection system continuously fails. Vessel to submit corrective action report to initiate permanent solution. Submit CAR ot OCMI by 31MAR2016.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 31 March 2016
Resolution: CAR submitted. Scanned into documents: CAR END-010
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 18 March 2016
Resolved
Vessel had port state control deficiencies that were not documented in SMS. Vessel could not provide any written guidance regarding how to document externally identified non-conformities. Vessel must document the non-conformities and provide written documentation of policy to OCMI by 31MAR2016.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 31 March 2016
Resolution: Received correspondence clearing def. Scanned into vessel documents ENDURANCE PSC 2-27-16
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 9 March 2016
Resolved
After failed attempts at repair in Fremantle, WA, 835 cleared/reissued to allow vessel to sail to Singapore to replace the system. S-VDR to be replaced prior to sail from Singapore.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2016
Resolved 16 March 2016
Resolution: Capsule and components replaced.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 2 March 2016
Resolved
Vessel SVDR is not operating properly. Make repair and provide technician report attesting that the SVDR is fully operation. Complete requirement to the satisfaction of FEACT.
Condition: Design Flaw
Due 8 March 2016
Resolved 9 March 2016
Lifesaving › Launching Appliances › Falls
Issued 25 February 2016
Resolved
Hydraulic rams on the free fall lifeboat davit are not functional leaving vessel without an adequate secondary means of launching the lifeboat. Repair and demonstrate proper operation prior to departure from Singapore, prior to 24MAR2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 7 June 2016
Resolution: Resovled by class report BT3152107.
Lifesaving › Launching Appliances › Padeye
Issued 20 January 2016
Resolved
Free fall lifeboat retaining bridle padeye's are wasted and enlongated. Replace or repair padeye's to origional condition
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2016
Resolution: Witnessed satisfactory repairs and satisfactory load test of bridle.
Construction/Loadline › Penetrations › Flange Pad
Issued 20 January 2016
Resolved
2nd Deck port fwd ballast tank vent piping is wasted at tank top intersection. Repair as origional.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2016
Resolved 28 January 2016
Resolution: Witnessed satisfactory repairs to piping