Records from 1981 to 2025. Most recent: inspection, 14 August 2025.
Inspection history · 74
14 August 2025
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8192798
4 June 2024
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7926860
12 July 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7740700
20 July 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7516025
27 June 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7488972
24 March 2021
COI Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7162524
25 June 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6986260
21 May 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6957529
24 May 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011605
23 April 2018
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6397561
21 February 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6091795
5 February 2016
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5807940
6 April 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5095857
29 April 2014
Welding Related Inspections Qualification Testing · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4847712
10 March 2014
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4811334
3 December 2013
In-Service Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4762137
9 April 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4277303
14 June 2010
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3760922
23 June 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3510691
15 July 2008
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3267495
19 June 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2961219
30 May 2006
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2664827
23 June 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2400275
24 August 2004
Periodic Inspection · MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2175269
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961068
14 August 2003
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1875703
18 June 2002
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1632521
20 June 2001
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1379359
9 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058836
14 November 2000
Type not recorded
No type recorded · Station Coos Bay · USCG Northwest District (CGD-NW) · Activity 1517816
11 February 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434989
17 February 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395111
18 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 455259
13 February 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1368614
14 February 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1368051
14 February 1996
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360362
2 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 757850
24 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 196871
17 November 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457215
3 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665483
12 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150228
18 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 464670
18 November 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469418
5 August 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 489729
19 November 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140031
19 November 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934254
17 July 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 449111
27 November 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236490
20 November 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236745
16 November 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243858
18 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 490129
25 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 462434
23 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 500255
22 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 521625
1 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469338
16 November 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214009
3 April 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 501339
18 November 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208644
10 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337291
27 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337107
19 November 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333457
9 July 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 489819
4 June 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 475298
5 May 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 505638
8 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 526918
20 November 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328688
28 May 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 537657
12 December 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 448023
20 November 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999673
26 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976010
22 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975656
29 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278196
19 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274653
2 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968733
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 July 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 degrees F., shall be suitably insulated where necessary to preclude injury to personnel. Vessel does not have lagging on exhaust. Install lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 21 July 2023
Resolution: MI verified both prime movers had adequate lagging on exhaust piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 July 2023
Resolved
Exhaust pipe installations must conform to the requirements of ABYC P-1. The exhaust system shall be designed and installed to prevent rain water from entering the engine through the exhaust system under normal operating conditions. Vessel's aft auxiliary engine did not have exhaust flapper preventing rain water from entering exhaust. Repair/ replace exhaust flapper.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 21 July 2023
Resolution: MI verified exhaust flapper was replaced on aft prime mover
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2023
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Servicing report for forward portable fire extinguisher was expired. Provide servicing report for both fire extinguishers on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 21 July 2023
Resolution: MI verified forward portable fire extinguisher was satisfactorily serviced
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 July 2023
Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Forward prime mover was missing machinery guards. Install machinery guard on inboard side of engine's rotating machinery.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 21 July 2023
Resolution: MI verified machinery guards were installed on forward prime mover
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2023
Resolved
The tank overfill alarm required by paragraph (a) of this section must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in the cargo deck area.Both light indicators did not light while alarm was sounding. Repair/replace lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 21 July 2023
Resolution: MI witnessed high level and overfill lights operational
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 May 2020
Resolved
Vessel is required to maintain annual inspections to keep the issued COI valid. Vessel was issued COI on 05 February 2016, and the last inspection was was completred on 25 April 2018. The vessel was found to be operating without a valid COI. Vessel is prohibted from operating until it obtains a new COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2020
Resolution: Conducted COI inspeciton and not-for-credit ISE. Issued vessel COI that will expire 28FEB2021. Vessel to undergo COI, drydock, ISE, and CTIE by drop dead date (28FEB2021).
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 25 April 2018
Resolved
Each cargo tank must have liquid overfill protection arrangements. Marine Inspector found the high level and overfill alarms to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2018
Resolved 27 April 2018
Resolution: Verified overfill devices were operating properly in accordance with regulations.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 25 April 2018
Resolved
The operator of a vessel shall provide transfer procedures. Marine Inspector found the operator unable to provide current transfer procedures.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2018
Resolved 27 April 2018
Resolution: Verified vessel had transfer procedures on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 April 2018
Resolved
When because of a change in the character of the vessel or vessel's route, equipment, etc., the vessel does not comply with the requirements of the Certificate of Inspection previously issued. Marine Inspector found the COI to have been issued to a previous owner and operator and not the current owner/operator.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2018
Resolved 27 April 2018
Resolution: Issued Certificate of inspection reflecting current owner/operator.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 April 2018
Resolved
At least 30 days prior to the expiration of the Certificate of Inspection, a vessel shall notify the Coast Guard if the vessel will be required to be reinspected for certification or will be operated in such a manner as to not require a Certificate of Inspection. Marine Inspector found vessel to have been sold and a new Certificate of Documentation issued on 22JUN17. The vessel was unable to provide a Certificate of Inspection with the current owner and operators.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2018
Resolved 27 April 2018
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 25 April 2018
Resolved
Vessel must have a current Certificate of Financial Responsibility. Operator was unable to provide a COFR to the Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2018
Resolved 27 April 2018
Resolution: Vessel provided valid COFR
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 April 2018
Resolved
The vessel response plan must include a list of tank barges covered by the plan. Marine Inspector found the plan containing the vessel vessels name in lieu of the vessels current name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 27 April 2018
Resolution: Vessel provided list of tank barges approved under plan.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2018
Resolved
Handrails must be maintained in good condition.
Marine inspector found the a handrail with broken welded attachment points on the stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 25 June 2020
Resolution: Handrails found to be in good condition.
Deck/Cargo › Towing › Chocks
Issued 25 April 2018
Resolved
Barge must fit fitted with ground tackle as deemed necessary. Marine Inspector found a damaged cleat on the starboard stern.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 25 June 2020
Resolution: Cleat replaced and in good condition.
Engineering › Compressed Air System (start air) › Piping
Issued 25 April 2018
Resolved
Piping systems must be suitable for the service intended. Marine Inspector found a damage compressed air line in the vicinity of the barge house.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 27 April 2018
Resolution: Verified air piping leak fixed
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 April 2018
Resolved
Every barge shall have its name or number displayed so it can be seen from either side. Marine Inspector found only the previous barge name on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 25 June 2020
Resolution: Name and number on both sides of vessel. Name and number on stern of vessel. Old name was still hard affixed but not visible due to paint. The old name will be removed at drydock in FEB 2021.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 25 April 2018
Resolved
Engine must have an operable RPM gauge.
The cargo pump engine RPM gauge is not operating properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 27 April 2018
Resolution: Verified RPM gague operable
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2018
Resolved
Piping whose temperatures exceeds 150F shall be suitably insulated where necessary to preclude injury to personnel. Marine Inspector found cargo pump exhaust piping missing insulation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 25 June 2020
Resolution: Insulation installed on cargo pump exhaust pipe.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 25 April 2018
Resolved
Piping whose temperatures exceeds 150F shall be suitably insulated where necessary to preclude injury to personnel. Install protective lagging on steam piping in locations where it is damaged or missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 25 June 2020
Resolution: Steam piping disconnected. Steam system to be removed fully at drydock in FEB2021.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 18 June 2002
Resolved
Install rising stem valve on cargo pipeline. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 20 June 2011
Resolved 15 July 2008
Resolution: Verified proper installation of rising stem valve.
Construction/Loadline
Issued 20 November 1990
Resolved
REPAIR CRACK IN # 1 STBD CARGO TANK AND ADJACENT TANKS PRIOR TO REPAIR. CONTACT A COAST GUARD MARINE INSPECTOR UPON COMPLETION OF REPAIRS. REPAIRS MUST BE VISUALLY INSPECTED AND AIR-TESTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR/USCG.
Condition: Unknown
Due 20 November 1990
Resolved 20 November 1990
Construction/Loadline
Issued 27 February 1988
Resolved
OFFLOAD REMAINING CARGO AND PROCEED TO SHIPYARD FOR REPAIRS TO COLLISION DAMAGE TO PORT BOW. NO CARGO IS TO BE LOADED UNTIL REPAIRS ARE COMPLETED TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR. VESSEL IS NOT TO LEAVE [name withheld] ZONE UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 27 February 1988
Resolved 27 February 1988
Construction/Loadline
Issued 19 October 1982
Resolved
EFFECT REPAIRS TO DAMAGED SIDE SHELL PLATING AND STRUCTURAL MEMBERS IN FOR-WARD RAKE. DETERMINE DAMAGE IN FORWARD STBD WING TANK AND REPAIR.
Condition: Unknown
Due 19 October 1982
Resolved 19 October 1982