Inspection record

Last inspected 29 June 2026
…with no type recorded25
Operational controls None recorded without a removal date
Years with a record 45 calendar years (1982–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1864 - Regulatory (Subpart C or D), Gross Ton 1864 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-45635
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 109

29 June 2026 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8418326
18 September 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8236553
16 October 2024 Administrative Inspection · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8019879
2 August 2023 Administrative Inspection · Internal Structural Exam · In-Service Inspection · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7758901
21 November 2022 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7595405
18 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7433131
15 October 2021 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7327225
17 September 2020 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7055245
16 October 2019 MTSA Verification · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6832353
19 June 2018 COI Inspection · Examination of Repairs · In-Service Inspection · MTSA Verification · Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6449607
15 March 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6372625
25 August 2017 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6247252
31 May 2017 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6155285
10 May 2017 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6141363
4 May 2017 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6139125
22 November 2016 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6045033
1 November 2016 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6032453
15 September 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6005964
2 December 2015 Examination of Repairs · MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5772104
5 June 2015 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5143144
5 May 2015 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5115068
19 November 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5027193
11 August 2014 Annual Inspection · Internal Structural Exam · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4945619
11 January 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4783844
13 December 2013 Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4769005
9 August 2012 COI Inspection · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4403789
13 July 2012 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4375657
20 June 2012 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4348149
5 June 2012 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4333670
11 April 2012 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4283663
1 November 2011 Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4180304
1 July 2011 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4061857
8 December 2010 MTSA Verification · Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3905154
25 June 2010 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3774517
17 June 2010 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3767429
1 June 2010 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3749339
10 May 2010 Construction Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3734945
12 March 2010 Construction Oversight · Welding Related Inspections Qualification Testing
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3694760
22 September 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3600327
16 July 2009 Welding Related Inspections Qualification Testing · Periodic Inspection · Hull Examination · MTSA Verification · Cargo Tank Internal · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3536367
13 February 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3417209
30 October 2008 Annual Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3353962
14 September 2007 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3033535
18 December 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2842833
4 December 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2833579
13 October 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2797527
30 January 2006 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2575855
19 January 2006 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2573701
27 December 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2556739
28 November 2005 Periodic Inspection · MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2538387
14 July 2005 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2426430
8 July 2004 MTSA Verification · Re-Inspection · Internal Structural Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2126483
27 February 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2014496
10 October 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1925707
23 July 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1855680
28 August 2002 COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1665564
18 May 2001 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471249
24 April 2001 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1061829
21 December 2000 Deficiency Check · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1395603
4 December 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 116022
4 December 2000 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 824304
11 October 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391404
13 August 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375882
6 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775913
22 June 1999 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441525
23 February 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1368988
9 September 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378457
4 September 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 53890
5 February 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390707
24 March 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465296
4 April 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1079034
10 February 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1407612
24 March 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 827862
21 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 486106
12 May 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1171025
15 March 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1165289
8 November 1993 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847968
25 March 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1151103
1 April 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 956686
19 March 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1261566
1 March 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995342
31 July 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 916422
12 April 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239937
21 September 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306531
14 August 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044120
2 June 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1196025
2 May 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 330217
2 May 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1030696
1 March 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 503558
12 October 1988 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886875
14 April 1988 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1036607
8 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 466040
24 February 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 468728
19 November 1987 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1334228
30 July 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1025942
13 July 1987 Examination of Repairs · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1024866
8 July 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1013067
2 April 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 500580
25 September 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 462281
25 September 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1312132
31 May 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302185
13 March 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 522137
12 June 1985 Re-Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981561
2 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290879
16 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975091
9 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285136
30 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280884
14 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968174
25 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972112

Deficiency record · 67

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 October 2024 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. 46 CFR 32.60-1(a) Marine Inspector noticed an isolated area of pitting on port side bow rake deck more than 1/8" deep. Marine Inspector noticed a crack in the forward starboard side saddle. Repair identified areas to the satisfaction of attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2024
Resolution: Conducted a visual exam of all repairs and witnessed air test at 1.0 PSI. Test satisfactory. Examined repairs of saddle. All SAT.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2017 Resolved
Vessel has thru-hull penetration/crease in #1P wing void sideshell, approximately 3' above unloaded waterline, approximately 8' forward of kevel. Temporary patch has been applied and is holding. Vessel is prohibited from any operations pending submission of repair/transit plan.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2017
Resolved 10 May 2017
Resolution: Verified repair; 5' X 3' insert at #1P wing void & 1.5' X 4' insert at #1S wing void via internal/external visual examination; no discrepancies noted. Witnessed satisfactory air test of both repairs.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 22 November 2016 Resolved
Cracked weld on inlet water pipe for the external cargo cooling/vapor compression system.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2016
Resolved 23 November 2016
Resolution: Repaired and proved proper operation
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 7 December 2015 Resolved
Vessel does not have written procedures for periodic safety tests for the cargo refrigeration system. Written testing procedures that state the setpoint, precautions, equipment status, etc must be provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 22 November 2016
Resolution: Reviewed company's safety test procedures for barge automation.
Construction/Loadline › Hull › Bracket
Issued 11 May 2015 Resolved
# 2 hopper space crop and renew keel plate transverse member at joint to keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 5 June 2015
Resolution: Vessel replaced wasted structural membes with new steel.
Construction/Loadline › Hull › Side Shell
Issued 11 April 2012 Resolved
Barge had a 20 by 20 inch insert welded and a visual inspectioin along with an air test (1.5) was performed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 April 2012
Resolution: Witnessed by MSU Port Arthur MI
Construction/Loadline › Hull › Weld
Issued 10 December 2010 Resolved
Crop and renew diagonals in bow rake to good metal, crop holes in collision bulkhead to good metal (min 18"x 18")
Due 10 January 2011
Resolved 18 January 2011
Resolution: Verified the completion of required repairs. Witnessed satisfactory air test of the bow rake.
Documentation › Markings/Placards › Warning Signs
Issued 8 December 2010 Resolved
Emergency stop on upper catwalk is not labeled; 46cfr64.93
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: Labeled emergency stop on upper catwalk
Engineering › Fuel Oil Service System › Hose
Issued 8 December 2010 Resolved
Fuel hoses on cargo pumps are dry rot; 46cfr56.60-25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: Renewed hoses
Documentation › Markings/Placards › Warning Signs
Issued 8 December 2010 Resolved
Vapor line not stenciled; 46cfr98.25-15
Action required: 705 - Other - as specified
Resolved 10 December 2010
Resolution: Stenciled pipe
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 8 December 2010 Resolved
Provide and install cargo valve for STBD header
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: installed cargo valve
Construction/Loadline › Hull › Weld
Issued 8 December 2010 Resolved
#2 port kevel is wasted, renew
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: kevel renewed
Construction/Loadline › Hull › Weld
Issued 8 December 2010 Resolved
considerable wastage on center upper structure, crop and renew as required. to include forward section where angle is detached from cradle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: Upper structure stiffeners renewed, framing under vapor tank renewed
Construction/Loadline › Hull › Weld
Issued 8 December 2010 Resolved
hopper bulwarks and stiffeners show considerable wastage; crop and renew as required
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: renewed portions of bulwarks and stiffeners
Construction/Loadline › Hull › Weld
Issued 8 December 2010 Resolved
renew brackets for the compressor liquid return line between cargo tanks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: renewed brackets
Construction/Loadline › Hull › Weld
Issued 8 December 2010 Resolved
Crop and renew to good metal decking forward of bulwark
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: renewed decking, PSI test satisfactory
Deck/Cargo › Cargo Refrigeration › General
Issued 11 September 2009 Resolved
Unable to conduct operational test of the refrigeration plant until cargo system is readied for operation. Perform operational test of the refrigeration system to include alarms and shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2009
Resolution: Obsvd sat test of alarms and shutdowns on refrigeration system.
Engineering › Compressed Air System (control) › Valve
Issued 11 September 2009 Resolved
Identified air leak for the pneumatic operations on the STBD vapor line emergency shutoff valve. Make repairs or renew valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2009
Resolved 15 October 2009
Resolution: Reviewed documents which provided proof of purchase and installation of the 4" vapor line pnuematic operated emergency shufoff valve. Post instalation function test was sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 September 2009 Resolved
Identified no guards or heat shields IVO of both cargo pump's exhaust systems. Provide guards on exhausts of both cargo pumps IAW 46 CFR 92.25-15.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 October 2009
Resolved 22 September 2009
Resolution: Obsvd lagging on cargo pump''s exhaust systems.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 September 2009 Resolved
Navigation lights not available for inspection. Perform functional test of navigation lights.
Action required: 705 - Other - as specified
Due 11 October 2009
Resolved 22 September 2009
Resolution: Obsvd sat performance of navigation lights.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 September 2009 Resolved
Observed faulty valve and missing activation chain for the emergency decontamination shower. Make repairs or renew valve and provide new activation chain.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2009
Resolution: Installed new handle to valve to operate shower. Obsvd sat operation of decontamination shower.
Construction/Loadline › Hull › Side Shell
Issued 30 October 2008 Resolved
1/2" hole in #3 port wingvoid side shell approximately 3' from bottom.
Condition: Damaged By Earlier Event
Due 31 October 2008
Resolved 31 October 2008
Resolution: 18"x18"x3/8" insert. Witnessed satisfactory air test.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 14 September 2007 Resolved
Cargo Relief Valves are expired on their 4 year test. Stbd side has been replaced and Prt side due to be replaced within 30 days. Issued 835 for deficiency. 46CFR98.25-95. (Extension granted on 12OCT07 to 28OCT07)
Due 28 October 2007
Resolved 1 November 2007
Resolution: All port side relief valves have been replaced and a certified report has been received. All SAT
Construction/Loadline › Structures › Superstructure
Issued 13 October 2006 Resolved
Port side bracket of ladder to observation platform is wasted and broken. Properly weld ladder to vessel bulwarks.
Due 13 December 2006
Resolved 8 December 2006
Resolution: Permanent repairs made at Vessel Repair in Port Arthur, TX.
Construction/Loadline › Structures › Air Pipe
Issued 13 October 2006 Resolved
Crop & renew ballast piping between #3 port side void and #3 stbd void.
Due 13 November 2006
Resolved 22 November 2006
Resolution: Received shipyard report that the ballast piping has been cropped and renewed to original construction.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 30 November 2005 Resolved
Repair, as original, # 2 upper saddle on stbd side
Due 30 December 2005
Resolved 21 December 2005
Deck/Cargo › Cargo Refrigeration
Issued 23 July 2003 Resolved
Repair wasted base of refrigeration alarm panel box. LEGACY COMPONENT DESC: Alarm panel box
Condition: Improper/Lack of Maintenance
Due 24 July 2003
Resolved 24 July 2003
Documentation › Markings/Placards
Issued 23 July 2003 Resolved
Re-paint vessel name/hailing port.
Due 24 July 2003
Resolved 24 July 2003
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 23 July 2003 Resolved
Provide respirators and EEBA as required for anhydrous ammonia barge transfer ops.
Due 24 July 2003
Resolved 24 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 23 July 2003 Resolved
Provide test reports for all P/V and vacuum relief valves on No. 1P and 1S cargo tanks by 30 AUG 03.
Due 30 August 2003
Resolved 30 August 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 23 July 2003 Resolved
Repair leak in flex hose at intercooler.
Due 30 August 2003
Resolved 28 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 August 2002 Resolved
Make steel repairs to catwalk and railings. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 28 August 2002 Resolved
Make steel repairs to base of ladder at port side midship (access to tank tops). LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Engineering › Diesel Engine (auxiliary)
Issued 28 August 2002 Resolved
Prove proper operation of port engine emergency shutdown LEGACY COMPONENT DESC: Air Silencer
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Navigation › Collision/Grounding Avoidance
Issued 28 August 2002 Resolved
Paint running light shields and make repairs as necessary. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 28 August 2002 Resolved
Replace light cover above engines/cargo pumps. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Deck/Cargo
Issued 24 April 2001 Resolved
MAKE PERMANENT REPAIRS TO CARGO PIPE LINE PRIOR TO NEXT LOAD OR NLT 24MAY01- WHICHEVER IS SOONER, AS PER 46 CFR 56.
Condition: Unknown
Due 24 May 2001
Resolved 28 August 2002
Resolution: New cargo piping installed/tested prior to COI.
Deck/Cargo
Issued 24 April 2001 Resolved
GAUGING REPORT IS REQUIRED FOR ENTIRE CARGO PIPE LINE PRIOR TO NEXT LOAD ORNLT 24MAY01 - WHICHEVER IS SOONER.
Condition: Unknown
Due 24 May 2001
Resolved 28 August 2002
Resolution: Gauging conducted for cargo pipeline that was not replaced.
Lifesaving
Issued 11 October 2000 Resolved
Provide proper securing device/strap (metal) for compressor oil tank/rack.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Deck/Cargo
Issued 11 October 2000 Resolved
Repair/replace support housings to stbd side cargo manifold shutdown valves.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Deck/Cargo
Issued 11 October 2000 Resolved
Provide proper securing device to portside alarm panel door.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Engineering
Issued 11 October 2000 Resolved
Repair/replace muffler to stbd pump prime mover (wastage).
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
Install proper light bulb in bow light fixture.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Deck/Cargo
Issued 10 February 1996 Resolved
REPLACE VAPOR/LIQUID MANIFOLD END SPOOL PIECES.
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Deck/Cargo
Issued 10 February 1996 Resolved
REPAIR/REPLACE INSULATION TO PIPING DAMAGED BY HYDRO-CLEANING.
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Construction/Loadline
Issued 10 February 1996 Resolved
DERUST AFT VOID HATCH COVER AND RISER, REPLACE GASKET
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Deck/Cargo
Issued 10 February 1996 Resolved
REPAIR/REPLACE TO ORIGINAL, SUPPORTS TO SHUTDOWN VALVES LOCATED ON ENDS OF LIQUID AND VAPOR LINES/MANIFOLD.
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Deck/Cargo
Issued 10 February 1996 Resolved
REPAIR/REPLACE TO ORIGINAL, CARGO HEADER PIPING DECK SUPPORTS.
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Deck/Cargo
Issued 10 February 1996 Resolved
REPAIR/REPLACE TO ORIGINAL, GUIDES FOR EMERGENCY SHUTDOWN CABLE
Condition: Unknown
Due 10 February 1996
Resolved 10 February 1996
Unknown
Issued 24 March 1995 Resolved
55 GALLON OIL DRUM ON DECK NOT SECURED. CORRECTED.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 24 March 1995 Resolved
VESSEL HAD 2 B-II PORTABLE FIRE EXTINGUISHERS ONBOARD. VESSEL REQUIRED TO HAVE 4 B-II FIRE PORTABLE EXTINGUISHERS ON BOARD. CORRECTED.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Lifesaving
Issued 24 March 1995 Resolved
CARGO INFORMATION CARD FOR ANHYDROUS AMMONIA(MSDS) NOT POSTED. CORRECTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 24 March 1995 Resolved
STARBOARD CARGO TANK PRESSURE GAUGE NOT WORKING. MAKE PERMANENT REPAIRS NOLATER THAN 07APR95.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 24 March 1995 Resolved
3" CRACK IN MAIN DECK KNUCKLE ON STERN ABOUT 1' PORT OF BARGE CENTERLINE. MAKE TEMPORARY REPAIRS PRIOR TO DEPARTURE. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF THE LOCAL OCMI NO LATER THAN 26MAY95.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Deck/Cargo
Issued 24 March 1995 Resolved
PROVIDE PROOF OF PROPER OPERATION OF EMERGENCY SHUT-OFF. CORRECTED.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Unknown
Issued 15 March 1994 Resolved
HAVE AIR RECEIVER MADE AVAILABLE FOR INTERNAL INSPECTION OR HYDRO TEST.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Deck/Cargo
Issued 2 May 1989 Resolved
HYDROSTATICALLY TEST THE BARGE SERVICE AIR LINES.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989 Resolved
TEST THE CARGO TANK RELIEF VALVES IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989 Resolved
REMOVE WASTED INSULATION IN WAY OF THE CARGO LIQUID AND VAPOR LINES FOR INSPECTION OF THE PIPING.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989 Resolved
PROVIDE GUARDS FOR THE WATER CIRCULATING PUMP COUPLINGS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989 Resolved
RENEW THE SOUNDING TAPE SLIP TUBES.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Construction/Loadline
Issued 14 April 1988 Resolved
CROP AND RENEW VARIOUS SIDE CHORDS AND ASSOCIATED INTERNALS IWO P&S WING VOIDS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988 Resolved
CROP AND RENEW VARIOUS BOTTOM LONGITUDINALS IWO THE CARGO TANKS HOPPER AREATO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Deck/Cargo
Issued 30 July 1987 Resolved
TEST THE OPERATION OF THE REMOTE SHUTDOWN OF THE CARGO TRANSFER PUMP ENGINEPRIOR TO TRANSFER OF CARGO.
Condition: Unknown
Due 30 July 1987
Resolved 30 July 1987
Construction/Loadline
Issued 25 September 1986 Resolved
EFFECT PERMANENT REPAIRS TO HOLE IN PORT SIDE BILGE KNUCKLE, AFTER RAKE.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Unknown
Issued 30 May 1984 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE PATCO 50, DN510493.
Condition: Unknown
Due 30 May 1984
Resolved 30 May 1984
Unknown
Issued 30 May 1984 Resolved
TEST SAFETY VALVES AT REQUIRED PRESSURE.
Condition: Unknown
Due 30 May 1984
Resolved 30 May 1984

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.