Inspection history · 103
28 May 2026
Vessel Attendance · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8373580
14 November 2025
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8268548
12 February 2025
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8078705
10 December 2024
MARPOL Annex VI Survey · Drydock Exam · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8035175
29 July 2024
MARPOL Annex VI Survey · Examination of Repairs · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7969992
30 May 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7947215
29 May 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7947298
21 May 2024
Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7895587
19 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7846906
27 February 2023
Deficiency Check · Periodic Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7642547
1 September 2022
In-Service Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7548509
31 May 2022
Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7464582
10 November 2021
MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7331804
8 January 2021
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7121509
17 April 2019
Cargo Tank Internal · COI Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6664738
27 February 2019
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6633969
27 February 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6638072
16 October 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6563829
27 August 2018
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6503823
18 September 2017
Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6270270
27 April 2017
Periodic Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6114536
10 August 2016
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5969247
5 November 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5757875
1 June 2015
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5141489
14 May 2014
Hull Examination · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4858422
6 September 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4707538
23 August 2013
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4694482
28 December 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4517963
10 September 2012
Periodic Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4436894
30 April 2012
Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4298454
1 September 2011
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4169729
20 December 2010
Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3913773
17 December 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3915298
16 November 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3892447
7 September 2010
DAPI Audit · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3829201
6 September 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3590013
27 May 2009
COI Inspection · Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check · Ballast Water Examination · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3487196
18 October 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3348914
2 September 2008
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3316007
2 September 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3316146
20 August 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3303994
13 August 2008
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3297559
30 July 2008
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3284176
26 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3249639
13 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3234533
19 February 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3149738
25 July 2007
MTSA Verification · Ballast Water Examination · Periodic Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3006626
22 June 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3004444
21 May 2007
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2936638
29 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2695486
31 May 2006
Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2665831
6 February 2006
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2580022
2 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2709538
27 July 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2441551
6 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2417428
28 June 2005
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2406732
22 April 2005
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2340902
10 November 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2258892
18 August 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2174378
15 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2295192
29 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2055247
8 April 2004
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2025328
2 June 2003
Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2037865
15 May 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1794116
20 June 2001
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1067496
24 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 156140
10 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1088683
10 June 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 44913
29 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 104990
11 September 1995
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394376
21 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 649017
9 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 187881
9 October 1994
COI Inspection · Deficiency Check · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177529
19 September 1994
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446118
15 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 172301
15 September 1994
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451969
13 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 34888
18 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70365
23 December 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160440
24 November 1993
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849463
21 January 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1132671
21 January 1993
Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141673
20 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117775
25 November 1992
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960478
23 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266075
15 January 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1269722
23 December 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255262
21 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72382
14 November 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911623
21 March 1990
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221724
26 January 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923077
14 January 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888242
6 December 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897443
23 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017639
23 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318790
18 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007612
9 July 1987
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1336713
5 December 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001644
12 February 1986
Deficiency Check · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301086
19 February 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1283718
12 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279643
21 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966939
15 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963312
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2026
Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements; Can be inspected at the tank for proper operation prior to each loading.
Crew was not able to test the overfill devices. Crew will familiarize themselves with testing procedures and demonstrate proper testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 4 June 2026
Resolution: Crew familiarized themeselves with the testing procedures for highlevel and overfill alarms and were able to demostrate in front of MI.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 May 2026
Resolved
Each generator must meet the applicable requirements for construction and and testing in section 4-8-3 of the ABS Steel Vessel Rules.
The low lube oil alarm for the #2 generator was not functioning as intended. A faulty sensor was the cause.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 4 June 2026
Resolution: A faulty sensor was discovered and replaced on the #2 generator. Alarm and shutdown witnessed by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 May 2026
Resolved
The inspection for certification shall include an inspection of the structure, boiler, and other pressure vessels and machinery. Upon inspection of the thermal fluid heater a gauge was broken and inoperable. Operator will replace the gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 4 June 2026
Resolution: Gauges on thermal fluid heater were replaced, witnessed by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 January 2024
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors...whose temperature exceeds 150F., shall be suitably insulated where necessary to preclude injury to personnel.
MI observed lagging not covering all areas on the exhaust piping, as well as indication of an exhaust leak.
46CFR32.35-1
46CFR56.50-1(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2024
Resolved 1 February 2024
Resolution: Lagging was installed on all areas of generator exhaust piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2024
Resolved
All tank vessels are subject to the regulations contained in subchapter J (Electrical Engineering). Repairs and replacements to electrical installations must in kind must comply with either subchapter J or those in effect when the vessel was built.
MI observed a junction box for the anchor windlass was not properly mounted.
46CFR31.35-1
46CFR110.01-3(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2024
Resolved 1 February 2024
Resolution: Junction box was properly installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 May 2022
Resolved
Vessels that operate in salt water must be inspected in accordance with the intervals set forth in table 31.10-21(a. Where table 31.10-21(a) indicates a 2.5 year examination interval, it means a vessel must undergo two examinations within any fire year period. No more than three years may elapse between any two examinations.
After administrative review, vessel internal structural exam inspection dates were found expired.
Vessel shall not operate until internal structure exam credit has been granted.
46CFR31.10-21(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 8 June 2022
Resolution: Credit ISE granted until 31 DEC 2022, to sync with anticipated drydock credit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 8 January 2021
Resolved
Ventilator openings shall be provided with efficient weathertight closing appliances.
Replace wasted gasket on the forward starboard natural ventilation cover.
46CFR42.15–45(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 14 January 2021
Resolution: Wasted gasket on the forward starboard natural ventilation cover was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 January 2021
Resolved
Exhaust pipe installations must conform to the requirements of ABYC P–1 and part 1, section 23 of NFPA 302
Repair exhaust leaks on noted on 1 and 2 service generators.
46CFR58.10–5(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 14 January 2021
Resolution: Caterpillar reps. replaced wasted exhaust gaskets in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 January 2021
Resolved
Efficient guard rails or bulwarks must be fitted on all exposed parts of the freeboard and superstructure.
Crop out and renew wasted stanchions noted.
46CFR42.15-75(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 14 January 2021
Resolution: GMR rewelded 4 wasted stantions.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2019
Resolved
Provide diver's report of condition of hull after grounding. To the satisfaction of the attending U.S. Coast Guard Marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2019
Resolved 1 March 2019
Resolution: Divers inspection indicated no damage to hull.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 27 August 2018
Resolved
The vessel has a letter from the COTP Sector St. Petersburg for an alternative to the requirements for annual hydrostatic testing of cargo piping approved under 33CFR156.107. However, the vessel did not make arrangements for testing of the high pressure alarm during this annual inspection as indicated by the exemption letter. This test shall be conducted and witnessed by a marine inspector prior to next discharge. 33CFR156.170(c)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2018
Resolved 7 September 2018
Resolution: Witnessed bench test of high pressure alarm while in the shop and witnessed proper installation of the high pressure switch after testing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2018
Resolved
The ring, lines and letters of the vessel's load line shall be painted in white or yellow on a dark ground. The deck line, plimsol, and load line markings on the barge's side were rusted and no longer of contrasting color. 46CFR31.25-1 46CFR42.13-40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2018
Resolved 7 September 2018
Resolution: MI witnessed properly painted deck line, plimsol, and load linme marking on the barges port side while moored.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 August 2018
Resolved
All access openings in the bulkheads shall be fitted with doors so that the whole structure is of equivalent strength to the unpierced bulkhead and weather-tight when closed. The gasket to the forward, port Thermal Fluid Heater Room door was wasted and no longer ensuring weather-tight integrity of the opening. 46CFR31.25-1 46CFR42.15-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2018
Resolved 7 September 2018
Resolution: The gasket to the forward, port Thermal Fluid Heater Room Door was replaced to the satisfication of the attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 27 August 2018
Resolved
The Officer in Charge, Marine Inspection must be notified before alterations or modifications that deviate from approved electrical plans. The starting batteries, cables, and battery charger for the two port side motors powering the generators have been replaced with a temporary arrangement that do not meet the original approval of the electrical starting system.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 8 November 2018
Resolution: Witnessed replacement of batteries and assiciated cable for the starting arrangements for the two port side engines powering the generators back to original design. Temporary arrangements have been removed.
Engineering › Pressure Vessel › Relief Valve
Issued 12 May 2017
Resolved
Provide proof of pressure vessel relief valve testing and pressure gauge calibration IAW 46 CFR 54.15-5
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 June 2017
Resolution: Provided calibration and testing certificates for each vavle.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2017
Resolved
Install protective covering over exhaust manifold on harbor generator IAW 46 CFR 56.50-1(k)
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 12 May 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 28 April 2017
Resolved
Provide proof of required testing for the thermal fluid expansion tank relief valve IAW 46 CFR 54.15-10
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 28 April 2017
Resolved
Prove proper operation of the starboard thermal fluid heater IAW 46 CFR 61.30-20
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 April 2017
Resolved
Prove proper operation of the ventilation louvers IAW 46 CFR 95.16-30
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Construction/Loadline › Markings › Load Line Mark
Issued 28 April 2017
Resolved
Place deck mark on side of vessel IAW load line certificate; IAW 46 CFR 32.07-5
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Fire Fighting › Structural - Horizontal Zones › General
Issued 28 April 2017
Resolved
Prove air tightness of generator engine machinery space IAW 46 CFR 95.16-30
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Construction/Loadline › Hull › Weld
Issued 27 April 2017
Resolved
Aft three frame gussets in the port aft void are bent and cracked. Repair as original to the satisfaction of the attending marine inspector IAW 46 CFR 31.10-21
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 3 May 2017
Resolution: Cropped and renewed.
Deck/Cargo › Cargo Stowage › General
Issued 27 April 2017
Resolved
Repair fallen insulation on cargo tank IAW 46 CFR 153
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Operations/Management › Vessel Activity › Other
Issued 27 April 2017
Resolved
Make 4P and 4S wing tanks available for inspection IAW 46 CFR 31.10-21
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Construction/Loadline › Structures › Deck Plating
Issued 10 August 2016
Resolved
Replace cracked/rusted aft port deck pipe cap IAW 46CFR 31.10-32.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2016
Resolved 12 September 2016
Resolution: Replaced cracked deck pipe crack.
Construction/Loadline › Structures › Ventilators
Issued 10 August 2016
Resolved
Replace starboard side goose neck fuel vent ball on top of house IAW 46CFR 31.10-32.
Due 7 September 2016
Resolved 12 September 2016
Resolution: Replaced fuel vent ball.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 10 August 2016
Resolved
Renew/calibrate cargo high pressure trip sensor and gage IAW 33CFR 156.170c.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2016
Resolution: Renewed and proved date of high pressure trip sensor.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 10 August 2016
Resolved
Renew cargo room supply vent piping due to multiple holes in piping IAW 46CFR32.60-20c.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2016
Resolution: Renewed cargo room supply vent.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 10 August 2016
Resolved
Replace Thermal Fluid Heater compartment supply fans and dampeners IAW 46CFR32.60-20c.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2016
Resolution: Replaced both supply fans.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 10 August 2016
Resolved
Repair exhaust leak on both center generator prime movers IAW 46CFR58.10-10.
Due 7 September 2016
Resolved 12 September 2016
Resolution: Repaired exhaust leak and tested gen sat.
Engineering › Gas Turbine (propulsion/auxiliary-electric) › Seal
Issued 1 June 2015
Resolved
Determine cause and repair fuel leak on #2 sea service generator. IAW 46 CFR 58.10-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2015
Resolution: Deficiency corrected prior to CG inspectors departing, determined to be loose fuel filter connection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 1 June 2015
Resolved
Properly label fuel shutoff station for port side cargo pumps. IAW 46 CFR 32.50-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2015
Resolution: Fuel shut station is now properly labeled.
Deck/Cargo › Cargo Heating › General
Issued 1 June 2015
Resolved
Visual inspection of thermal fluid heater #2 revealed incomplete combustion of fuel resulting in buildup of carbon in combustion chamber. Replace fuel nozzle and clean out combustion chamber. IAW 46 CFR 61.30-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2015
Resolution: TFH fuel nozzle was overhauled by tech, tests run and found to be all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 June 2015
Resolved
Conduct annual maximum working pressure on cargo discharge piping prior to discharging cargo. IAW 46 CFR 35.35-70 (b)
Action required: 10 - Deficiency Rectified
Due 1 June 2015
Resolved 21 November 2019
Resolution: Def corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 June 2015
Resolved
Conduct cargo pump pressure gage test to ensure accuracy prior to discharging cargo. IAW 46 CFR 35.35-70(c)
Action required: 10 - Deficiency Rectified
Due 1 June 2015
Resolved 21 November 2019
Resolution: def corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 1 June 2015
Resolved
Conduct annual test on cargo pump relief valves at pressure to which they are set to open prior to discharging cargo. IAW 46 CFR 35.35-70(d)
Action required: 10 - Deficiency Rectified
Due 1 June 2015
Resolved 21 November 2019
Resolution: Def corrected
Deck/Cargo › Ballast › Vents
Issued 1 June 2015
Resolved
Repair / Replace ball valve on #3 wing tank. IAW 46 CFR 45.133
Action required: 705 - Other - as specified
Due 1 July 2015
Resolved 26 June 2015
Resolution: Ball valve has been replaced with new.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 June 2015
Resolved
Provide guard for lens on light on transverse bulkhead starboard side forward of thermal fluid heater space. IAW 46 CFR 111.75.20(b)
Action required: 705 - Other - as specified
Due 1 July 2015
Resolved 26 June 2015
Resolution: Guard provided for the light.
Construction/Loadline › Hull › Bottom Plating
Issued 20 December 2010
Resolved
Proplery determine that the bottom hull plating has sustained no damage, during the UTV FALCON grounding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2010
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2008
Resolved
Repair 1" hole IWO #1 Stbd. ballast tank at frame #25 no later than vsl's next scheduled dry-docking.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 26 May 2009
Resolution: Cropped and renewed area during dry docking.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 July 2008
Resolved
Multiple temporary repairs to be completed at next drydock (est. May 2009). Temp repairs include multiple fractures in the ballast tank bhd IWO #2 P/S cargo tanks. Temp repairs consisted of drill stops, re-welds, and doublers. See MISLE activity 2936638 for previous temporary repairs made.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 August 2008
Resolution: Vsl rep submitted satisfactory photos of repairs and dye penetrant NDT.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 July 2008
Resolved
Repair proposal to be submitted to cognizant OCMI in reference to the permanent repairs to be conducted at dry dock for the previously authorized temporary repairs. Proposal to also address long-term outlook on repairs to barge.
Due 18 August 2008
Resolved 17 June 2009
Resolution: Temporary repairs replaced, area cropped and renewed during dry docking.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 July 2005
Resolved
PROVIDE LIGHT COVERINGS FOR FWD STORE ROOM LIGHT FIXTURES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 July 2005
Resolved
REPAIR EMERGENCY ESCAPE LIGHT IN FWD STORAGE ROOM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 27 July 2005
Resolved
AUDIT TRANSFER PROCEDURES & PROVE COMPLIANCE WITH 33 CFR 155.720.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 27 July 2005
Resolved
PERFORM HYDROSTATIC TESTING OF CARGO PIPING & GAUGE CALIBRATION.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 31 May 2006
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 27 July 2005
Resolved
PROVIDE A COPY OF SOPEP APPROVAL LETTER.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Deck/Cargo › Cargo Heating › General
Issued 27 July 2005
Resolved
PROVIDE COVER FOR THERMAL OIL MANIFOLD JUNCTION BOX IN CARGO PUMP ROOM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Deck/Cargo › Cargo Heating › General
Issued 27 July 2005
Resolved
RENEW CARGO GAUGES AS NECESSARY.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2005
Resolved
PAINT NAV LIGHT BACKING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Engineering › Fuel Oil Service System › Hose
Issued 27 July 2005
Resolved
REPLACE FUEL HOSE TO NO. 1 SEA SERVICE GENERATOR/PRIME MOVER & INSTALL CHAFFING GEAR AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2005
Resolved
REPLACE EYE WASH BOTTLES THROUGHOUT VSL AS NECESSARY.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 23 August 2005
Construction/Loadline › Hull › Hull Plating
Issued 22 April 2005
Resolved
Repair fractured bottom plating IWO port and stbd skegs prior to carriage of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2005
Resolution: Repairs complete. reference Activity 2340902
Deck/Cargo › Cargo Heating › General
Issued 10 November 2004
Resolved
Make repairs to the #1 thermal fluid heater fuel oil pressure switch prior to operating for cargo operations.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 24 November 2004
Deck/Cargo › Cargo Heating › General
Issued 18 August 2004
Resolved
Replace all four thermal fluid hoses on the vent pipe in the No. 1 cargo void due to damage sustained during a fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 18 August 2004
Resolved
Replace lagging on vent pipe and tank top due to damage sustained in fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 April 2004
Resolved
Provide MSC approved test procedures for Thermal Fluid Heaters (2). 46CFR63.10-1
Due 30 June 2004
Resolved 20 August 2004
Electrical › Electric Supply System (service) › Transformer
Issued 2 June 2003
Resolved
Submit the hazardous location plan of the vessel's electrical equipment installations.
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 31 May 2006
Engineering
Issued 9 October 1994
Resolved
Test relief valves for air receivers 292150, 292147 and 292149.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Navigation
Issued 9 October 1994
Resolved
Prove operation of port navigation light.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Deck/Cargo
Issued 9 October 1994
Resolved
Make operational test of anchor.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Engineering
Issued 9 October 1994
Resolved
Open air receivers #292350, #292147 and #292149 for inspection.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Construction/Loadline
Issued 19 September 1994
Resolved
CONDUCT INTERNAL STRUCTURAL EXAM AND DRYDOCK TO EXAMINE HULL DAMAGE. MAKE PERMANENT REPAIRS TO DAMAGED AREA FORWARD STARBOARD, FOREPEAK.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Construction/Loadline
Issued 15 September 1994
Resolved
You are directed to proceed at earliest possible time directly to Uncle Sam, Louisiana to discharge cargo and then proceed to the nearest anchorage.
Condition: Unknown
Due 17 September 1994
Resolved 19 September 1994
Construction/Loadline
Issued 15 September 1994
Resolved
You are restricted from any further cargo operations and non-emergency movement until a Coast Guard Marine Inspector approves a damage assessment and repair proposal.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Electrical
Issued 24 November 1993
Resolved
Properly dead-end electrical cable at port nav. light.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Engineering
Issued 24 November 1993
Resolved
Remove rags, trash bags & misc items throughout generator room & forepeak (housekeeping)
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Accommodation/Occupational Safety
Issued 24 November 1993
Resolved
Properly secure skinner valves servicing #1 generator.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Electrical
Issued 24 November 1993
Resolved
Provide light fixture covers for missing light installation throughout beltway tunnel, over looking generator in generator room & at bottom of ladder_x001C_to generator room.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Construction/Loadline
Issued 21 January 1993
Resolved
PROCEED TO 1ST ST WHARF TO EFFECT PERMANENT REPAIRS TO 6" X 4" HOLE IN THE PORT BOW AT THE 13' DRAFT MARK.
Condition: Unknown
Due 30 January 1993
Resolved 26 January 1993
Electrical
Issued 23 December 1991
Resolved
REPAIR CIRCULATING FAN BLADE ON MAIN SHIP'S GENERATOR.
Condition: Unknown
Due 23 December 1991
Resolved 23 December 1991
Navigation
Issued 23 December 1991
Resolved
REPAIR STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 23 December 1991
Resolved 23 December 1991
Electrical
Issued 26 January 1990
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUT-DOWN FOR 100 KW GENERATOR AS PER 46 CFR 111.10-5 (OLD J).
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Electrical
Issued 26 January 1990
Resolved
LABEL ALL ELECTRICAL BREAKERS ON LIGHTING PANEL ON MAIN SWITCHBOARD AS PER 46 CFR 111.30-5.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Deck/Cargo
Issued 26 January 1990
Resolved
PROVIDE PROPER RELIEF VALVE FOR TOP AIR RECEIVER (HOU80-000228) IN FORCASTLE HAWSER LOCKER AS PER 46 CFR 54.15. AIR RECEIVER IS TO REMAIN ISOLATED UNTIL COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Construction/Loadline
Issued 6 December 1988
Resolved
REPLACE OR RENEW ALL MISSING OR BROKEN DOGS ON TOPSIDE HATCH COVERS. THIS INCLUDES CARGO HATCHES, ACCESS HATCHES THROUGH CARGO HATCHES, AND MACHINERYSPACE HATCHES. 46 CFR 97.15-20(A)(1).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Deck/Cargo
Issued 6 December 1988
Resolved
RENEW WASTED SECTION OF WASHDOWN PUMP DISCHARGE LINE LOCATED IN AFT PUMP ROOM. LINE CURRENTLY HAS SOFT PATCH. 46 CFR 91.25-10(A).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 6 December 1988
Resolved
RENEW HATCH COVER TO MIDSHIPS DISCHARGE BELT ROOM. (BETWEEN NO. 5 & 6 CARGOHATCHES) 46 CFR 97.15-20(A)(1).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 6 December 1988
Resolved
STENCIL FLUSH DECK REACH RODS VALVES ON FOCSEL AND PROVIDE ACCESS WRENCHES.46 CFR 56.50-1(G)(2)(II) AND (II).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 6 December 1988
Resolved
REPLACE MISSING COVER FOR STBD SIDE FOCSLE GOOSENECK. 46 CFR 56.50-85(A)(6).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 6 December 1988
Resolved
STENCIL EMERG VENT SHUTDOWN SWITCH LOCATED AT TOPSIDE ENTRANCE TO GENERATOR ROOM.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Electrical
Issued 6 December 1988
Resolved
REPLACE MISSING GROUND FAULT INDICATOR LIGHTS ON MAIN SWITCHBOARD. 46 CFR 111.05-21,23 AND 25.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Electrical
Issued 6 December 1988
Resolved
PLACE COVERS ON INCANDESCENT LIGHTS ON FRONT AND BACK OF MAIN SWITCHBOARD.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Accommodation/Occupational Safety
Issued 6 December 1988
Resolved
REPLACE MISSING SECTION OF RAILING ON STBD. SIDE NEXT TO STERN NOTCH. 46 CFR 92.25-90(A).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 6 December 1988
Resolved
RENEW GASKET ON STBD FOCSLE HATCH COVER. 46 CFR 97.15-20(A)(1).
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Deck/Cargo
Issued 6 December 1988
Resolved
PLACE CORRECT RELIEF VALVES ON 3 AIR CANNON AIR RECEIVERS. AND DEMONSTRATE PROPER OPERATION OF THESE, AND 2 STARTING AIR RECEIVERS RELIEF VALVES. 46 CFR 54.15-10(A)
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Construction/Loadline
Issued 18 September 1987
Resolved
BEFORE LOADING CARGO OR DEPARTING THE MISSISSIPPI RIVER AND ITS TRIBUTARIES, EFFECT REPAIR TO COLLISION DAMAGE ON STARBOARD BOW IN WAY OF COLLISION BULKHEAD.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Electrical
Issued 12 February 1986
Resolved
INSTALL REMOTE REACH RODS FOR FUEL OIL SERVICE TANK AND FUEL OIL DAY TANK.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Electrical
Issued 12 February 1986
Resolved
REPAIR AND PROVE OPERATION OF AFT VENTILATION MOTORS AND SHUT-DOWNS.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Construction/Loadline
Issued 15 December 1982
Resolved
(REQUIREMENT D1, CONTINUED) WHERE NEEDED TO ALLOW EXAMINATION OF POSSIBLE DAMAGE BY A COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 December 1982
Resolved 15 December 1982
Construction/Loadline
Issued 15 December 1982
Resolved
MAKE PERMANENT REPAIRS, AND PLACE IN GOOD WORKING ORDER THE PORT FORWARD LOADING DOOR LOCATED BETWEEN FRAME 40 AND 44.
Condition: Unknown
Due 15 December 1982
Resolved 15 December 1982
Construction/Loadline
Issued 15 December 1982
Resolved
OPEN AND CLEAN TO BARE METAL, PORT FORWARD BALLAST TANKS IN WAY OF FRAMES 19 THRU 40 OUTBOARD REMOVING EXISTING FLOW COAT AND PROVIDING STAGEING
Condition: Unknown
Due 15 December 1982
Resolved 15 December 1982