MAURY USCG vessel records
← All vessels

STC 2313

Built
1968
Last inspected
12 September 2017
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 12 September 2017
…with no type recorded30
Operational controls None recorded without a removal date
Years with a record 24 calendar years (1985–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46035

Documentation record

Registered dimensions (L × B × D)245.0 ft × 54.0 ft × 12.5 ft
Registered tonnagegross 1,808 / net 1,808
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE BRIDGE COMPANY · NASHVILLE, TN, UNITED STATES · built 1968
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1808 - Regulatory (Subpart C or D), Gross Ton
1808 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 75 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 10 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 75

12 September 2017 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6265030
7 February 2008 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3143804
14 March 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2887852
22 February 2007 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2876722
5 January 2006 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2561942
1 November 2004 Annual Inspection · MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2232231
25 June 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2130746
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966289
24 November 2003 Internal Structural Exam · Cargo Tank Internal · COI Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1945170
29 August 2003 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1889923
16 February 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1749510
20 November 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1708203
28 October 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1697153
7 January 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1476066
5 July 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1370286
11 March 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 28382
22 August 2000 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1401306
16 June 2000 Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 818926
4 April 2000 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 444296
14 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 490174
22 September 1999 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1035431
12 September 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 783924
6 January 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 126180
2 November 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404631
9 June 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470155
29 October 1997 Deficiency Check · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1119809
11 September 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1442623
13 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 25913
24 March 1997 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441195
19 March 1997 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1100466
27 January 1997 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1102601
17 October 1996 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1159009
23 October 1995 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1191353
3 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 456443
13 April 1995 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 847428
12 December 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 447155
2 December 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 161266
29 November 1994 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 867016
22 June 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 211842
7 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 505069
1 December 1993 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 849110
13 September 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 504260
19 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 524645
8 April 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1148662
18 February 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 531194
30 December 1992 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1140993
4 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 218965
3 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 3804
21 November 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 528001
18 August 1992 Examination of Repairs · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1269929
19 May 1992 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 948376
24 January 1992 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254842
30 October 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942151
21 October 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 487940
23 September 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 444093
2 May 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 463672
12 April 1991 Examination of Repairs · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1242639
21 August 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923923
11 July 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910284
3 May 1990 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 909589
24 April 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1229330
26 March 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909493
23 February 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218308
17 January 1990 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1233407
22 September 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1310184
2 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 462031
12 April 1989 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1350382
27 February 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1337043
10 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 524531
26 December 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 449459
9 April 1987 COI Inspection · Hull Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1310659
23 January 1986 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 996189
7 November 1985 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 992558
22 October 1985 Credit Drydock · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 993849
8 January 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1286069

Deficiency record · 40

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 February 2007 Resolved
Provide metal enclosure for prime mover in accordance with 46 CFR 32.25-5 within 30 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 14 March 2007
Resolution: Metal enclosure provide for prime mover in accordance with 46 CFR 32.25-5
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 February 2007 Resolved
Demonstrate proof of means to eliminate liquid condensate in vapor piping - no drain lines noted (46 CFR 39.20-1(a)(4)) within 2 weeks
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 14 March 2007
Resolution: Drain installed in lowest portion of VSC line . 46 CFR 39.20-1(A)(4)
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 February 2007 Resolved
Amend cargo transfer procedures and graphs to reflect max flow rates for VCS.
Condition: Improper Installation
Due 8 April 2007
Resolved 29 March 2007
Resolution: Cargo Transfer Procedures and graphs amended to reflect limitations set by MSC VCS approval letter.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 January 2006 Resolved
Machinery guard at prime mover did not cover the last 8 inches of rotating machinery.
Condition: Improper Installation
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 January 2006 Resolved
Exhaust guard at prime mover was missing a diamond shaped section from the center of the guard.
Condition: Unknown
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2006 Resolved
Navigation light screens were green vs. matte black.
Condition: Improper/Lack of Maintenance
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2006 Resolved
Extension cords used to power navigation lights had exposed wiring at the connections due to a damaged caused by a tow break away.
Condition: Damaged By Earlier Event
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 January 2006 Resolved
Stenciled warnings to confined spaces were severely faded and need repainting.
Condition: Improper/Lack of Maintenance
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 6 January 2006 Resolved
Support at the exhaust end of vapor piping was severely wasted.
Condition: Improper/Lack of Maintenance
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 January 2006 Resolved
Cable runs along the stripping line were attached with plastic ties.
Condition: Improper Installation
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2006 Resolved
Battery/light installation on the bow was not an approved lighting fixture.
Condition: Placed in Improper Service
Due 6 January 2006
Resolved 6 January 2006
Resolution: Removed the battery/light.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 6 January 2006 Resolved
The emergency shut down pull station was installed at the bow vs. mid length or 100 feet.
Condition: Improper Installation
Due 6 February 2006
Resolved 12 January 2006
Resolution: Correction notice provided by Higman Marine.
Construction/Loadline › Hull › Hull Plating
Issued 20 November 2002 Resolved
fracture found iwo #2 stbd wing void at water line.
Action required: 705 - Other - as specified
Resolved 21 November 2002
Resolution: an 18"X18"X3/8" insert iwo damage
Construction/Loadline
Issued 2 November 1998 Resolved
OLD INSERT CRACKED APPROX. 10 INCHES FROM SIDE SHELL COLLISION. INSERT WAS FOUND NOT PROPER (SQUARE CORNERS, 10IN BY 10IN) CROP AND RENEW.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Construction/Loadline
Issued 2 November 1998 Resolved
HATCH DOG BROKEN WHEN OPENED FOR INSPECTION BY SHIPYARD. RENEW SAME.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Deck/Cargo
Issued 2 November 1998 Resolved
GAUGE STICK FOR HIGH/OVERFILL ALARM/SHUTDOWN FOUND WITH WATER IN TUBE HAMPERING PROPER OPERATION. BLOW WATER CLEAR OF TUBES.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Construction/Loadline
Issued 11 September 1997 Resolved
CONDUCT CARGO TANK INTERNAL EXAM AT NEXT GAS FREE, BUT NLT 9 NOV 97._x001C_
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Deck/Cargo
Issued 11 September 1997 Resolved
REPLACE FLAME SCREEN ON VAPOR LINE VENT RISER.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Engineering
Issued 11 September 1997 Resolved
REPLACE FLAME SCREEN ON F/O TANK.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Deck/Cargo
Issued 11 September 1997 Resolved
repair hatch ears on #1 stbd void.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Deck/Cargo
Issued 11 September 1997 Resolved
make vapor line open for inspection.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Deck/Cargo
Issued 11 September 1997 Resolved
REMOVE/REPLACE FLAME SCREENS ON ALL PAINTED GOOSENECKS._x001C_
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Engineering
Issued 11 September 1997 Resolved
PROVIDE SHUTOFF VALVE ON SUPPLOY FUEL LINE FOR PRIME MOVER AND REPLACE FLEXIBLE HOSE ON SUPPLY LINE.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 24 April 1990 Resolved
PRIOR TO LOADING CARGO, MAKE PERMANENT REPAIRS TO DAMAGED AREAS IN #1 PORT WING VOID AND #2 PORT WING VOID IN WAY OF UNAUTHORIZED CEMENT BOX PATCHES.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 24 April 1990 Resolved
MAKE PERMANENT REPAIRS TO BROKEN BOTTOM LONGS AT THE AFT BULKHEAD BRACKETS AND LOOSE FRAME DIAGONALS IN THE FORWARD RAKE VOID.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 24 April 1990 Resolved
MAKE PERMANENT REPAIRS TO BUCKLED WEB FRAMES #2, #3, AND #4 IN #2 STARBOARDWING VOID.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Deck/Cargo
Issued 23 February 1990 Resolved
REMOVE OR MAKE OPERABLE ALL (3) DECK CABLE WINCHES IN WAY OF BROKEN BRAKES,BROKEN LOCKING PINS, HOLED/JAGGED HAND WHEELS IN ACCORDANCE WITH 46USC3313(B).
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Construction/Loadline
Issued 23 February 1990 Resolved
EFFECT REPAIRS TO THE APPROX 15" FRACTURE AT STERN TRANSOM DECK KNUCKLE APPROX 6 FT INBOARD OF PORT SIDE IN ACCORDANCE WITH 46USC3313(B).
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Deck/Cargo
Issued 23 February 1990 Resolved
PROVE SATISFACTORY OPERATION OF THE STEAM HEATING RELIEF VALVE IN ACCORDANCE WITH 46CFR61.15-5(C).
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Deck/Cargo
Issued 23 February 1990 Resolved
PROVIDE PROOF OF SATISFACTORY TESTS ON CARGO LINES, GUAGES AND RELIEF VALVEIN ACCORDANCE WITH 33CFR156.170/155.820.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Deck/Cargo
Issued 23 February 1990 Resolved
GAS FREE AND MAKE AVAILABLE FOR INTERNAL AND EXTERNAL INSPECTION ALL CARGO TANKS IN ACCORDANCE WITH 46USC3313(B). STRUCTURE AND TANKS TO BE CHECKED FOR STRESS/FATIGUE FAILURE AND DAMAGE POSSIBLY RESULTING FROM BARGE BEING OVERLOADED FROM 15FEB90 THRU 23FEB90.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Deck/Cargo
Issued 23 February 1990 Resolved
REPLACE ALL CARGO TANK AND SLOP TANK P/V VALVES WITH P/V VALVES THAT ARE COMPATIBLE WITH ACRYLONITRILE IN ACCORDANCE WITH 46CFR151.55-1(E), AND MAKEALL P/V VALVES AVAILABLE FOR INSPECTION. (PRESENT CARGO/SLOP TANK P/V VALVES ARE OF BRASS CONSTRUCTION).
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Deck/Cargo
Issued 22 September 1989 Resolved
PROVIDE COPY OF APPROVED PLANS FOR THE INSTALLED VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 22 September 1989
Resolved 22 September 1989
Documentation
Issued 12 April 1989 Resolved
PROVIDE/INSTALL POLLUTION PLACARD ON BARGE.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Deck/Cargo
Issued 12 April 1989 Resolved
PERFORM HYDRO TEST ON CARGO PIPING AND TEST RELIEF VALVE OR PROVIDE DOCU- MENTATION OF RECENT TEST.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Deck/Cargo
Issued 8 January 1985 Resolved
CONDUCT TEST TO CARGO HANDLING EQUIPMENT PRIOR TO NEXT CARGO OPERATION.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Deck/Cargo
Issued 8 January 1985 Resolved
REPAIR PRESSURE GAGE TO HYDRAULIC ACCUMULATOR ON DIESEL ENGINE START SYSTEM
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Deck/Cargo
Issued 8 January 1985 Resolved
REPAIR PRESSURE GAGES ON ALL HYDRAULIC LINES TO CARGO PUMPS.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Deck/Cargo
Issued 8 January 1985 Resolved
REPAIR CARGO PUMP DISCHARGE PRESSURE GAGES ON ALL PUMPS.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Deck/Cargo
Issued 8 January 1985 Resolved
RENEW WIRE ON STB BOW WINCH.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985

Recorded names · 1

MMI-303 (2003–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record