Records from 1997 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 42
14 May 2026
COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8372822
13 January 2026
Deadweight Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8296078
24 September 2025
Simplified Stability Test · Deficiency Check · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8240147
6 September 2024
Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7997820
18 April 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7671338
27 January 2023
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7628562
5 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7604106
3 February 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7390308
15 November 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7357357
8 June 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7284284
24 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7162262
19 January 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7126903
9 April 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6937681
18 March 2020
DAPI Audit · Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6927725
31 July 2019
DAPI Audit · Administrative Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6768695
18 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6754775
10 January 2019
DAPI Audit · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6608846
25 January 2018
Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6344371
9 February 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087842
12 April 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5854530
5 January 2016
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5792599
18 January 2012
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4226903
20 January 2011
DAPI Audit · Annual Inspection · Hull Examination · Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3929164
28 January 2010
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3671955
26 January 2009
COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3399068
5 November 2008
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3358051
16 January 2008
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3131824
9 January 2007
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2852908
12 January 2006
COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2565406
23 February 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2011913
20 January 2004
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1988981
10 February 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1748928
10 January 2003
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1748961
5 December 2002
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1715078
11 January 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1492198
12 January 2001
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1423500
7 March 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1046305
17 February 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815391
20 January 2000
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1399286
8 January 1999
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1473517
13 January 1998
Initial Certification · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383753
13 November 1997
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463333
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 January 2023
Resolved
Scope of drydock and internal structure examinations: an internal structure exam consists of a complete examination of the vessel's main strength members which include major internal framing, hull plating and planking, voids and ballast, cargo and fuel oil tanks. Fuel tank is inaccessible for inspection and must be made available for inspection. Owner to devise plan for fuel tank inspection no later than 10FEB23. Marine inspector must inspect fuel tank once available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 24 September 2025
Resolution: Vessel has installed new CG approved fuel tank. See activity # 7997820
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 January 2023
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed for the hull material condition. The hull has several areas of concern of pitting and corrosion of the aluminum bottom. Owner to devise plan to prove corrosion is within acceptable limits as per structural design standards in 46 CFR 177.300. Submit plan to OCMI no later than 10FEB23. Marine inspector must be present for hull gauging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 15 October 2025
Resolution: Hull repair plans accepted and repairs completed to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 January 2023
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel could not demonstrate the exterior leak test. The vessel needs to conduct the exterior "leak" test and overpressure "stress" test IAW Sector Honolulu Work Instruction 07 in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2023
Resolved 15 October 2025
Resolution: New collar installed and tested IAW Sector Honolulu WI 7
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 January 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission as set forth in 47 CFR part 80. Communications Act Safety Radiotelephony Certificate is expired since April 2021. Owner to acquire certificate to attending marine inspector w/n 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 30 January 2023
Resolution: new license issued
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 31 January 2023
Resolution: Refresher training held and proof of attendance submitted to OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 January 2023
Resolved
Ring life buoys: a vessel must carry one floating waterlight unless it is limited to daytime operations. Vessel is not limited to daytime operations and the waterlight is extinguished; must replace the battery in the waterlight for the ring life buoy prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2023
Resolved 31 January 2023
Resolution: waterlight replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2023
Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 in subchapter Q of this chapter. The life ring was unserviceable with rips and cracks. Vessel rep replaced onscene, cleared deficiency.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2023
Resolved 27 January 2023
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2023
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing of fire protection equipment to the marine inspector. The Fireboy and onboard 40BC's were not serviced. Additionally the required 10BC was not onboard. Third party was present and installed a new 10BC onboard and serviced the Fireboy and 40BC. Deficiency rectified onscene; however future inspections require servicing to be done annually and before the CG inspection.
Action required: 10 - Deficiency Rectified
Due 30 January 2023
Resolved 27 January 2023
Resolution: Replaced and serviced during inspection
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 January 2023
Resolved
The floating waterlight must be attached around the body of the life float by a 10mm (3.8 inch) lanyard, resistance to deterioration from ultraviolet light and at least 5.5 meters (18 feet) in length. Current lanyard is 3 ft and not attached around body of float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 31 January 2023
Resolution: line replaced and installed properly
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 January 2023
Resolved
The master may allow reduced crew for limited or special operating conditions subject to the approval of the OCMI. In accordance with Sector Honolulu Work Instruction 31, reduced manning, the deckhand may enter the water while moored or at anchor during in-water passenger activity if provisions in the instruction are met; vessel is not equipped with sufficient required portable oxygen. Vessel is not authorized to have the deckhand enter the water until adequate portable oxygen is onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 31 January 2023
Resolution: oxygen refilled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel was underway emitting white smoke from the stern and engine is not operating as designed. Owner to identify maintenance/repair plan for the engine issues and submit proposal to local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2022
Resolved 13 December 2022
Resolution: tested and inspected, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The jet drive has a steady water stream flowing into the vessel. Owner to identify issue and submit proposal to local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2022
Resolved 13 December 2022
Resolution: Seal was replaced, no longer leaking.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 5 December 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be
examined to see that there is no excessive accumulation
of oil or other matter that might create a fire hazard,
or clog bilge pumping systems. Vessels bilge and bilge pumps are covered in oil, owner to clean bilges to OCMI
satisfaction.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2022
Resolved 13 December 2022
Resolution: bilge cleaned out, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2022
Resolved
Each ring life buoy on a vessel must Be approved in accordance with § 160.050 in subchapter Q of this chapter. Ring buoy grab line and retro-reflective tapes are not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: New ring buoy installed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. No stern light.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: Installed unobstructed all around light for stern light.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 February 2022
Resolved
A suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Except on a vessel limited to daytime operations, the compass must be illuminated. The compass is not illuminated. Vsl restricted to daylight operations until compass has illumination.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: Replaced magnetic compass with illumination. Tested sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 February 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Iodine and Aspirin expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: Replaced with unexpired Iodine and Aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 February 2022
Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for lifefloats and buoyant apparatus must meet the following specifications:Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddle is broken in half and retro-reflective is unserviceable.
Vessel is limited in operation to not more than 3 miles from shore and not more than 20 miles from a harbor of safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2022
Resolved 17 February 2022
Resolution: New paddles onboard with vessel name and new retroreflective tapes installed on the lifefloat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2021
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the required testing of portable, semi-portable, and fixed fire extinguishing equipment. Vessel has not had fire fighting equipment serviced in the last year.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2021
Resolution: Owner provided proof the fire fighting equipment had been serviced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 March 2021
Resolved
n a vessel of at least 26 feet in length a visual and audible alarm must be provided at the operating station to indicate high water in a machinery space bilge. Machinery space bilge high level alarm does not result in visual or audible alarm at the operating station.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2021
Resolution: The bilge high level alarm was repaired and the audible alarm sounded at the operating station.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 March 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicators at the operating station for automatic bilge pumps are not operational.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2021
Resolution: The bilge high level alarm was repaired and the visual indicator was seen at the operating station.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 March 2021
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in
which they are employed. Vessel needs to complete 1.25
MAWP collar inflation pressure test.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: Vessel completed 1.25 MAWP collar inflation pressure test.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 March 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel does not have a splint.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 25 March 2021
Resolution: The vessel has a splint in the first aid kit.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 March 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The vessel's EPIRB battery is expired and needs to be replaced. No restrictions are put on the vessel because it's route does not allow the vessel to go more than 3 miles from shore. The vessel is equipped with a 12 person life float as per their COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2020
Resolution: The EPIRB was replaced.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 10 January 2019
Resolved
Vessel was not marked with vessel name or hailing port per 46 CFR 67.123
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2019
Resolution: Vessel properly marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 January 2019
Resolved
Excess coolant and oil in bilges. Remove excess liquid and clean bilges to the satisfaction of the marine inspector in accordance with 46 CFR 176.830.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2019
Resolution: Bilges cleaned of excess fluids.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 January 2019
Resolved
Vessel's VHF radio was not hooked up to enable DSC capabilities. Ensure DCS VHR radio installed and operational Per 47 CFR 80.1101.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2019
Resolution: VHF DSC radio operational.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
VHF Radio was not operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2016
Resolution: VHF Radio mic was not installed correctly.
Construction/Loadline › Hull › Bottom Plating
Issued 20 January 2011
Resolved
Make repairs to hull plating (inset) port side amidships. Repair fractured welds port/stbd spray rails amidships. Repairs to be made to rtn hull to original scantling.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 27 January 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 January 2011
Resolved
Prove operation of high water alarm. (46 CFR 182.530(a)).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 January 2011
Resolved
Prove operation of pre-engineered fire extinguishing system. (engine shutdown, override, alarm, and indicator lights). (46 CFR 181.420).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 January 2011
Resolved
Install manual pull cable. (46 CFR 181.420(a)(2)).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2011
Communications › Alarms/Indicators › High Water Alarm
Issued 20 January 2011
Resolved
Install high water alarm indicator light. (46 CFR 182.530(a)).
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 4 February 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 January 2011
Resolved
Install auto bilge pump operating indicator light. (46 CFR 182.530(3)(c)).
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 4 February 2011
Lifesaving › Lifefloat › Float Free
Issued 20 January 2011
Resolved
Prove float free arrangement.
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 21 January 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2010
Resolved
Bilge wiring not supported in engine compartment.
Due 28 February 2010
Resolved 25 June 2010
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 January 2010
Resolved
Perform satisfactory drills.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 25 June 2010
Personnel › Training › First Aid/CPR
Issued 28 January 2010
Resolved
Provide proof of first aid/CPR training.
Due 28 February 2010
Resolved 25 June 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 January 2010
Resolved
Replace 2 unserviceable lifejackets.
Due 28 February 2010
Resolved 25 June 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 January 2010
Resolved
Each internal baffle for the sponsoon failed the test prescribe in MTN01-08.
Due 28 February 2010
Resolved 25 June 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 January 2010
Resolved
Renew wasted clamps at stbd transom.
Due 28 February 2010
Resolved 25 June 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 26 January 2009
Resolved
Re-attach lifelines on the starboard side sponson.
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 23 February 2009
Lifesaving › Lifefloat › Netting
Issued 26 January 2009
Resolved
Re-weld net ring on life float.
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 23 February 2009
Engineering › Fuel Oil Service System › Gauge
Issued 26 January 2009
Resolved
Prove fuel gauge.
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 23 February 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 January 2008
Resolved
Renew renew cracked, jagged edged wind screen forward of stearing station.
Action required: 705 - Other - as specified
Due 17 February 2008
Resolved 4 March 2008
Resolution: Removed wind screen.
Lifesaving › Lifefloat › Float-free Link
Issued 16 January 2008
Resolved
Provide correct weak link for painter connection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2008
Resolved 17 January 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 January 2008
Resolved
Renew 5 adult PFD's
Due 17 January 2008
Resolved 17 January 2008
Lifesaving › Lifefloat › Quantity
Issued 16 January 2008
Resolved
Provide primary lifesaving for 50% of the total persons on board. Vessel currently has a 12 person lifefolat. COI lists 24 passengers and 2 crew.
Action required: 705 - Other - as specified
Due 17 February 2008
Resolved 4 March 2008
Resolution: Reduced total persons to 24. Change reflected on COI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 January 2007
Resolved
Prove fire extinguisher bracket is proper for the fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2007
Resolved 19 March 2007
Lifesaving › Lifebuoys › Quantity
Issued 9 January 2007
Resolved
Renew the life ring and lines.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Lifesaving › Lifefloat › Painter
Issued 9 January 2007
Resolved
Renew launcher and painter line for life float.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 January 2007
Resolved
Prove fixed fire fighting system servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 January 2007
Resolved
Provide four (4) Type I lifejackets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 January 2007
Resolved
Provide documentation for servicing of portable fire extinguisher.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 January 2007
Resolved
Provide a hydrostatic release for the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 January 2007
Resolved
Prove navigation lights.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 19 January 2007
Construction/Loadline › Hull › Side Shell
Issued 9 January 2007
Resolved
Repair rub rail on the sponson on the port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 19 January 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 9 January 2007
Resolved
Repair lifelines on the starboard side.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2007
Resolved 19 January 2007
Construction/Loadline › Hull › Bracket
Issued 9 January 2007
Resolved
Repair broken hull to sponson connector on the bow.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 19 March 2007
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2007
Resolved
Make the bilge area forward to the engine and below the fuel tank accessible for inspections. Renew as original platting as needed.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 19 March 2007
Construction/Loadline › Structures › Superstructure
Issued 9 January 2007
Resolved
Repair broken wind screen.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 19 March 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 12 January 2006
Resolved
Remove matting from passenger foot straps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2006
Resolved 10 November 2006
Fire Fighting › Fire Bucket › Availability
Issued 12 January 2006
Resolved
Prove fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2006
Resolved 10 November 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 January 2006
Resolved
Prove bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2006
Resolved 10 November 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 January 2006
Resolved
Prove nav lights.
Due 12 February 2006
Resolved 10 November 2006
Construction/Loadline › Hull › Hull Plating
Issued 12 January 2006
Resolved
Repair pitting in jet drive housing.
Due 12 February 2006
Resolved 10 November 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 January 2006
Resolved
Update first aid kit.
Due 12 February 2006
Resolved 12 January 2006
Engineering › Bilge Water Management System
Issued 20 January 2004
Resolved
Prove proper operation of high water alarm to CG inspector. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Due 5 February 2004
Resolved 17 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 January 2004
Resolved
Provide (1) child and (1) adult CG approved lifejackets. Passenger count is restricted to 20 max, until lifejackets are provided. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 17 February 2004
Resolved 17 February 2004
Navigation › Piloting/Steering
Issued 20 January 2004
Resolved
Provide US Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Improper/Lack of Maintenance
Due 5 February 2004
Resolved 17 February 2004
Construction/Loadline › Hull
Issued 20 January 2004
Resolved
Make proper repairs to forward port baffle and conduct baffle test IAW MSO inspection note #22 to the approval of CG inspector. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 21 February 2004
Resolved 17 February 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 January 2003
Resolved
Provide first aid kit IAW 46CFR184.710. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 10 February 2003
Resolved 10 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 January 2003
Resolved
Provide hiking strap IAW MSO Honolulu inspection note #22. LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 10 February 2003
Resolved 10 February 2003
Lifesaving › Buoyant Apparatus
Issued 10 January 2003
Resolved
Make proper repairs to lifefloat IAW manufacture specs.
Condition: Unknown
Due 10 February 2003
Resolved 10 February 2003
Lifesaving › Lifebuoys
Issued 10 January 2003
Resolved
Prove proper operation of waterlight for ring life buoy IAW 46CFR180.70. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Due 10 February 2003
Resolved 10 February 2003
Navigation › Piloting/Steering
Issued 10 January 2003
Resolved
Provide US Coast pilot, current chart, tide tables, Tidal current tables and international rules to the road. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Due 10 February 2003
Resolved 10 February 2003
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2002
Resolved
Submit repair proposal for cracks in port and starboard bow.
Condition: Unknown
Due 5 December 2002
Resolved 5 December 2002
Construction/Loadline
Issued 20 January 2000
Resolved
Replace plastic drain plug with suitable metallic plug NLT 2FEB00.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Construction/Loadline
Issued 20 January 2000
Resolved
Renew MDE sea valve NLT 2FEB00.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000