Records from 1997 to 2026. Most recent: inspection, 19 February 2026.
Documentation record
Registered dimensions (L × B × D)130.4 ft × 26.0 ft × 11.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)130.4 ft × 26.0 ft × 11.1 ft
ITC tonnagegross 236 / net 70
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
236 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 44
19 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8315277
8 May 2025
Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8131870
8 February 2024
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7861795
31 January 2024
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7858641
2 February 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7631056
16 March 2022
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7412916
17 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7199042
17 March 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6927788
15 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6643361
5 March 2018
Internal Structural Exam · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6368904
12 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762505
17 October 2014
COI Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5006960
17 June 2014
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4891513
6 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4335518
6 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4335543
3 June 2012
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4332486
3 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4349261
22 October 2010
Administrative Inspection · Re-Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3875219
1 October 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3865133
22 October 2008
Hull Examination · Internal Structural Exam · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3349403
29 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3089307
16 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2909080
24 February 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2877206
24 October 2006
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2807279
14 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2504131
3 October 2005
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2507847
3 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2509332
4 May 2005
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2348579
1 May 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2353061
19 November 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2244226
7 September 2004
Damage Survey · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2189137
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977658
12 November 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1946565
22 October 2003
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1933684
14 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1845729
15 November 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1676581
1 November 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447160
15 February 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059000
14 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101993
20 March 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 637807
1 March 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 215174
5 November 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434952
5 November 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432025
14 November 1997
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381074
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 May 2025
Resolved
Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system.
Ventilation shutdown was inoperable.
46 CFR 176.810
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2025
Resolution: MIs verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 May 2025
Resolved
Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and
weather decks. Two holes found in the hull. Require inspection of cutout; fit up; back gouge; and final NDT.
46 CFR 176.802
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2025
Resolution: MIs verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 May 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: MIs verified repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2025
Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant, and be custom engineered to meet the requirements of this section. Remote CO2 pull boxes require labeling.
46 CFR 181.410
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: MIs verified repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 May 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Inadequate guards around #1 MDE and sewage pump motor.
46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: MIs verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 May 2025
Resolved
life float—Approved under approval series 160.027 or other standard specified by the Commandant; w/subdivision — 100% life float capacity for POB.
Vessel is limited to max 50 POB until replacement of one
unserviceable life float due to deteriorated lines and netting.
46 CFR 180.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: MIs verified repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have interconnected system. Vessel to submit a written plan to the OCMI on how it will meet this requirement within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 23 February 2023
Resolution: Plan submitted and reviewed by CIV Donley. SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2023
Resolved
Except as noted in paragraph (d) of this section, the data shall be stamped directly on the pressure vessel. The data shall be legibly stamped and shall not be obliterated during the service life of the pressure vessel. In the event that the portion of the pressure vessel upon which the data is stamped is to be insulated or otherwise covered, the data shall be reproduced on a metal nameplate. This plate shall be securely attached to the pressure vessel. The nameplate shall be maintained in a legible condition such that it may be easily read. The data plate on vessel's port air receiver was missing. No other means to identify pressure vessel's required data could be found by vessel rep.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 24 February 2023
Resolution: Witness vessel crew install new pressure vessel with proper stamp/data plate
Fire Fighting › Nozzles › Location
Issued 3 June 2012
Resolved
Place noxzzles on all fire hoses at stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2012
Fire Fighting › Fire Hoses › Connections
Issued 3 June 2012
Resolved
Hook up all required fire hoses to stations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2012
Construction/Loadline › Structures › Trunk
Issued 3 June 2012
Resolved
G/W leaking crack on STBD jet drive engine exhaust
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2012
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 3 June 2012
Resolved
Renew broken vertical pipe at lube oil storage tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 3 June 2012
Resolved
Replace all missing light covers in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2012
Stability › Watertight Integrity › General
Issued 3 October 2005
Resolved
Make permanent repairs to vessel, IWO Stbd side shell and Bottom plating. Also included in repairs, make permanent repairs to Port inbd Main engine and clutch, to include shafting and propeller.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 October 2005
Resolution: Damage satisfactory repaired and inspected by [name withheld]