Inspection history · 20
23 October 2024
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8023788
11 July 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7956007
7 November 2023
Examination of Repairs · Drydock Exam · Welding Related Inspections Qualification Testing · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7828019
12 July 2023
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7740709
8 November 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7591650
25 May 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7459098
8 December 2021
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7364841
30 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7359596
10 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7348760
2 July 2021
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7242237
20 April 2020
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6940014
28 October 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6843757
10 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6831913
18 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6825772
12 July 2018
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6476786
22 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6359910
30 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6315911
21 September 2017
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6271824
21 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6216288
5 July 2016
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5930536
05 - Radio Communications › N/A - No Subsystem › Facilities for reception of marine safety inform.
Issued 11 July 2024
Resolved
Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must Be equipped with a NAVTEX receiver conforming to the following performance standards: IMO Resolution A.525(13), as revised by IMO Resolution MSC.148(77) and ITU-R M.540-2 (all incorporated by reference, see § 80.7).
Vessel is not equipped with a NAVTEX receiver. Vessel is limited to no more that 100 NM from shore until a NAVTEX is installed and a new Communications Act Safety Radiotelephony Certificate is obtained.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2024
Resolved 24 October 2024
Resolution: Documents sent
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022
Resolved
Radio transmitting and receiving installations or radiotelephones are required on certain vessels carrying passengers. Details of the application of this requirement as well as the details of the installation shall be as set forth in the regulations of the Federal Communications Commission (47 CFR Chapter 1).
Marine Inspector discovered vessel's FCC Radio Safety Telephony Certificate and FCC Bridge-to-Bridge certificate are expired.
Renew both FCC certificates and have them posted on board.
46 CFR 184.25-1
47 CFR 80.1001/1005
47 CFR 80.901
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 14 November 2022
Resolution: New certificates on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2022
Resolved
A vessel must carry either a first aid kit approved under approval series160.041 or a kit with equivalent contents and instructions.
Marine Inspector discovered ammonia inhalants missing from first aid kit.
Provide ammonia inhalants for first aid kit and stow on board vessel.
46 CFR 184.710
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 16 November 2022
Resolution: New ammonia inhalants purchased and on board vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 July 2021
Resolved
46 CFR 183.01-15(a)
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition - (2) Flexible & portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring.
The three (03) battery chargers installed must have permanent wiring, and not be powered via outlets & extension cords.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 7 July 2021
Resolution: Vessel hard-wired the battery chargers to the distribution panel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 July 2021
Resolved
46 CFR 183.05-50(b)
Wiring joints and splices. (1) Wiring joints and splices shall be mechanically secure.
The port side generator battery charger is connected via electrical tape. Make a permanent splice that meets this part.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 7 July 2021
Resolution: Vessel made permanent splices without the use of electrical tape.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 July 2021
Resolved
46 CFR 181.405(c)
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with and independent modular smoke detection.
The main accommodation spaces below the main deck require smoke detection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 5 July 2021
Resolution: Vessel installed modular smoke detectors in the lower accommodation spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 July 2021
Resolved
46 CFR 184.220(a)
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas.
The oven must be fitted with a locking device to prevent the door from opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 5 July 2021
Resolution: Vessel installed a locking device to secure the oven door.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 July 2021
Resolved
46 CFR 184.220(d)
Grab rails must be installed on a cooking appliance when determined by the cognizant OCMI to be necessary for safety.
The oven is not fitted with any type of grab rail.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 5 July 2021
Resolution: Vessel installed grab rails around the perimeter of the oven.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 July 2021
Resolved
46 CFR 184.220(e)
Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range.
The stove has no devices to prevent pot movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 5 July 2021
Resolution: Vessel installed appropriate sea rails to prevent pot/pan movement.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 July 2021
Resolved
46 CFR 177.25-1
All vessels with crew members living on board shall be provided with crew accommodations of sufficient size, adequate construction, and with suitable equipment to provide for the protection and accommodation of the crew.
The port side refrigerator is not secured in place resulting an a crew/passenger hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 5 July 2021
Resolution: Vessel secured the refrigerator to the bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2021
Resolved
46 CFR 182.25-10(a)
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). A vessel of over 65' in length must have two (02) fixed power pumps at 50 GPM.
Engine room bilge failed to prime/operate and pump water from the machinery space bilge.
Action required: 10 - Deficiency Rectified
Due 9 July 2021
Resolved 2 July 2021
Resolution: Vessel crew replaced the bilge strainer, and operated the bilge pump for MIs to witness.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 July 2021
Resolved
46 CFR 184.710
A vessel must carry a first aid-kit approved under 160.041 or a kit with equivalent contents and instructions.
The first-aid kit contained expired eye wash, burn gel, and iodine.
Action required: 10 - Deficiency Rectified
Due 16 July 2021
Resolved 2 July 2021
Resolution: Vessel owner replaced the expired items prior to MI departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2020
Resolved
Shutoff, valves, installed so as to close against the fuel flow, must be fitted in the fuel supply line. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
Generator fuel supply did not have a emergency shutoff from outside of the generator space. Vessel is required to install an emergency shutoff to the satisfaction of a USCG Marine Inspector.
46 CFR 182.455)b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2020
Resolution: Vessel installed a remote emergency shutoff to both the port and starboard generators.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 April 2020
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Generators did not have sufficient guards to protect against personnel injury. Vessel is required to install guards to the satisfaction of a USCG Marine Inspector.
46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2020
Resolution: Vessel installed machinery guards on both generators.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 April 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Inspector observed a fuel leak in the piping to the fuel pump. Vessel required to conduct repairs to the satisfaction of a USCG Marine Inspector.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2020
Resolution: Vessel replaced wasted hose that was causing the leak with a new hose.
Engineering › Fuel Oil Service System › Hose
Issued 22 February 2018
Resolved
STBD MDE fuel supply hose, pinhole leak spraying atomized fuel in the air and on port MDE. Replace flex hose with a J-1942 as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 February 2018
Resolution: Witness satisfactory installation of a new F/O supply hose. Hose has been replaced with a ISO 7840 A-1 (221FR-6 SAE) hose. All sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 21 July 2017
Resolved
Vessel did not have crew on board vessel, unable to conduct drills, underway operations, verify safe manning, correct credentials, and DAPI.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 February 2018
Resolution: Conducted sat drills with vsl crew, checked all crew credentials, all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 21 July 2017
Resolved
Piping from vessels turbo chargers had no lagging on exhaust pipes immediately adjacent to turbo's. Install lagging to satisfaction of attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 30 November 2017
Resolution: Lagging installed as required, all sat.
Engineering › Pressure Vessel › Piping
Issued 21 July 2017
Resolved
Hydraulic hoses for deck equipment found to have wasted seathing. Replace to the satisfaction of the attending Marine Inspector. Real cite is 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 30 November 2017
Resolution: Installed new hoses are required, all sat.
Construction/Loadline › Structures › Door
Issued 21 July 2017
Resolved
Door at aft end of the house wasted and no longer weather tight. Replace at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Resolution: New water tight door installed, all test sat.
Fire Fighting › Portable Foam Applicators › General
Issued 5 July 2016
Resolved
Vsl does not have required firefighting equipment for the carriage of hazmat. 49 CFR 179.101
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2016
Resolved 21 July 2016
Resolution: Vessel operator provided required fire fighting equipment.
Stability › Weathertight Integrity › General
Issued 5 July 2016
Resolved
Weathertight door for accommodation space is wasted in multiple spaces. Fix and repair dor to satisfaction of attending marine inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 21 July 2016
Resolution: Vessel crew made required repairs to wethertight door.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 5 July 2016
Resolved
Crew could not demonstrate proper overspeed trips on generators. Must demonstrate overspeed as per John Deere recommendation to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 19 August 2016
Resolution: Crew replaced relay and demonstrated overspeed as per John Deere recommendation, test sat