MAURY USCG vessel records Sign in
← All vessels

NORDIC HAWK

NORDIC HAWK is a 1997 tank ship. The Coast Guard has recorded 27 inspections since 1997, most recently in December 2011, along with 10 deficiencies and 4 operational controls.

Records from 1997 to 2011. Most recent: inspection, 27 December 2011.

Built
1997
Last inspected
27 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9131149 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
466921
Flag
BAHAMAS, THE
—
Maury page id
psix-466921

Inspections, by type

…with no type recorded13
Years with a record 14 calendar years (1997–2011)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it151475 - Dead Weight, Ton
174349 - Displacement, Ton
80187 - Regulatory (Subpart C or D), Gross Ton
80187 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 27

27 December 2011 COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4213283
26 November 2010 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3898896
5 May 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3468319
25 October 2008 ISPS II Exam · COC-TVE Annual · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3351149
22 June 2007 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2954089
15 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2888384
24 August 2006 Ballast Water Examination · ISPS II Exam · STCW 95 Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2758827
23 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2757764
13 June 2005 ISPS III Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2383718
5 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2379441
7 October 2004 NPV Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2215669
6 September 2004 ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2190246
11 May 2004 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2066354
11 March 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2024485
5 February 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2000853
3 June 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1808937
24 March 2002 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1597360
21 March 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1495779
13 March 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1601510
15 May 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1064202
26 March 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 288521
26 March 2001 Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061312
26 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 276301
28 January 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 794683
26 January 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425049
19 December 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 411168
19 December 1997 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 780913

Deficiency record · 10

Electrical › Electric Supply System (service) › Cable
Issued 26 November 2010 Resolved
0950 - Electrical equipment in general - Special precautions shall be taken when electrical cables are installed in hazardous areas that introduce the risk of fire or explosion in the event of an electrical fault. The PSCO observed fractures and temporary repairs on the outboard side of the electrical conduits which intersect at the forward most junction box. - SOLAS II-I Reg. 45 (2009 Cons.)
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 20 June 2011
Resolution: Vessel submitted documentation from class attesting to the repairs.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 26 November 2010 Resolved
1810 - Cargo area segregation - The inert gas system shall be so designed, constructed, and tested. Where the steam lines penetrate the deck water seal there has been a failure of the external plating. The crew has conducted a non class approved temporary repair using epoxy and a small plate with bolt to secure it in place. - FSS Code Chapt. 15 2.1.2
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 20 June 2011
Resolution: Vessel submitted documentation from class attesting to the repairs.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 5 May 2009 Resolved
Vessel requested inbound LOD for INOP Echo Depth Sounder. 33 CFR
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2009
Resolution: Rec''d Tech report all sat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 October 2008 Resolved
Battery for light on Starboard bridge wing lifebuoy is expired. Provide new battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 3 October 2009
Communications › Internal Communications System › Portable Radios
Issued 25 October 2008 Resolved
Batteries for portable VHF radios are expired. Provide new batteries for radios.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 3 October 2009
Lifesaving › Lifeboat Equipment
Issued 11 May 2004 Resolved
port life boat spray curtain pump inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 13 May 2004
Deck/Cargo
Issued 24 March 2002 Resolved
INCINERATOR PANEL FURNACE THERMOCOUPLE TEMPERATURE GAUGE INOPERABLE. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN LEGACY COMPONENT DESC: INCINERATOR PANEL FURNANCE
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2002
Resolved 5 April 2002
Resolution: LOSMS RECIEVED A REPORT OF REPAIR ON THE GUAGE
Documentation
Issued 19 December 1997 Resolved
PROVIDE PROOF OF VRP BEING ON BOARD PRIOR TO DISCHARGING CARGO AND IN NO CASE LATER THAN 23DEC97
Condition: Unknown
Due 23 December 1997
Resolved 22 December 1997
Deck/Cargo
Issued 19 December 1997 Resolved
HAVE CLASS PROVE PROPER OPERATION OF TEMP GAUGE AND HIGH TEMP ALARM ON IGS PRIOR TO DISCHARGING CARGO AND IN NO CASE LATER THAN 26DEC97
Condition: Unknown
Due 26 December 1997
Resolved 22 December 1997
Deck/Cargo
Issued 19 December 1997 Resolved
PROVIDE PROOF OF SPAN GAS ON BOARD AND COPY OF LOG SHOWING CALIBRATION OF IGS O2 ANALYZER PRIOR TO DISCHARGING CARGO AND IN NO CASE LATER THAN 26DEC97.
Condition: Unknown
Due 26 December 1997
Resolved 22 December 1997

Ownership record