MAURY USCG vessel records Sign in
← All vessels

WILMINA

WILMINA is a 1997 tank ship. The Coast Guard has recorded 42 inspections since 1998, most recently in January 2010, along with 19 deficiencies and 8 operational controls.

Records from 1998 to 2010. Most recent: operational control imposed, 21 January 2010.

Built
1997
Last inspected
21 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9151840 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
469589
Flag
NORWAY
—
Maury page id
psix-469589

Inspections, by type

…with no type recorded22
Years with a record 12 calendar years (1998–2010)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it47975 - Convention (Subpart B), Net Ton
149775 - Dead Weight, Ton
174237 - Displacement, Ton
79494 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 42

21 January 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3673788
23 October 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3350197
23 January 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3134788
9 December 2007 MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Annual · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3108218
2 February 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2866280
23 October 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2806440
9 July 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2707181
19 May 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2653650
10 April 2006 COC-TVE Renew · ISPS I Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2617086
9 April 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2620774
4 April 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2616446
8 March 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2598307
7 March 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2602884
10 August 2005 NPV Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2457327
3 August 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2450436
8 April 2005 Ballast Water Examination · COC-TVE Annual
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2327557
27 July 2004 MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2146871
24 July 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2145512
2 April 2004 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2036360
5 February 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2000853
8 May 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1819535
11 March 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1755957
22 November 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709457
19 November 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709006
10 October 2002 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1690086
10 October 2002 Security Inspection
Physical examination · Aids to Navigation Team Long Island Sound · USCG Northeast District (CGD-NE) · Activity 1765981
20 August 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663938
20 August 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1699529
17 July 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1647699
20 April 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1604687
28 March 2002 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598691
16 February 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1489848
14 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075507
17 March 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 288025
17 March 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1366236
28 March 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276038
15 February 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275065
15 February 2000 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 815638
6 February 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 425361
12 March 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 28297
14 January 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 411883
14 January 1998 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1111219

Deficiency record · 19

Navigation › Collision/Grounding Avoidance › Radar
Issued 21 January 2010 Resolved
Inbound: 21JAN2010 The vessel was granted a Letter of Deviation to enter the Port of Corpus Christi with an inoperable secondary radar. The following restrictions are required: daylight transit, tug assist.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2010
Resolution: 31JAN2010: After reviewing the technician''s report from Kongsberg Maritime Inc., the restriction on the vessel is released.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 9 December 2007 Resolved
The portable Flammable vapor detection equipment could not be properly calibrated.
Due 16 December 2007
Resolved 23 January 2008
Resolution: Received proper documentation satisfying the requirement.
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2007 Resolved
Prior to entering the port of Corpus Christi, DNV reported the M/V Wilmina had a crack at the bottom bilge plating at frame 61.The sea water leakage is now contained /stopped by temporary fitting. Class report states that permanent repairs must be conducted prior to next cargo load. Vessel may not enter a U.S. Port without a written report from DNV attesting to the permanent repairs of the hull
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2007
Resolved 12 April 2007
Resolution: Received a class report from DNV dated 13FEB2007 verifying that satisfactory permanent repairs were made while vessel was in dry-dock. 01 deficiency cleared. 0 deficiencies remain outstanding. Class report is attached.
Fire Fighting › Fire Main › Condition
Issued 8 April 2005 Resolved
Make permanent repairs to soft patch on fire main in way of #2 pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting main fire pump outlet pipe renewed and found in order.
Lifesaving › Launching Appliances › Falls
Issued 8 April 2005 Resolved
Life raft and rescue boat davit wires renewed July 2002 and there is no record of end for end at 30 months. Correct to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting liferaft and rescue boat davit wires have been turned end to end. In addition, a new procedure has been implemented in the planned maintenance system on board and in order.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 April 2005 Resolved
Ops manual chapter 3 has no appendix A, which is required for the master's hand over. Correct to Satisfaction of RO designated by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting appendix A (i.e.,manual Masters'' hand over checklist) to be provided on board no later than 4/30/05.
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 8 April 2005 Resolved
Two life jackets on bridge missing lights, whistles and markings. Corrected on spot.
Due 8 April 2005
Resolved 8 May 2005
Resolution: corrected on spot
Fire Fighting › Fire Hoses › Condition
Issued 8 April 2005 Resolved
Unable to prove proper operation of fire monitors due to flooding of engine room bilge by holed fire main and leaking seals. Prove proper operation to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting fire monitors were tested upon completion of fire main repairs and found satisfactory.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 8 April 2005 Resolved
Confined space entry permit system not always being used. Master made ballast tank inspection at relief with no permit. Ballast tank inspection 01/06/2005. Correct to the satisfaction of RO designated by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Non conformity issued during audit; company should ensure that all personnel involved in SMS have an adequate understanding of rules & regulations, codes.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 April 2005 Resolved
Hot work permits not being utilized as required by ops manual chapter 7. Vessel sand blasting tanks and making weld repairs to ballast tanks. Correct to the satisfaction of RO designated by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting to proper procedures to be implemented/utilized by vessel; NC issued for lack of record keeping.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 8 April 2005 Resolved
Company is updating SMS on a regular basis, but vessel is not implementing changes as evidenced by use of forms and check lists that are several revisions old. Perform additional external audit to satisfaction of RO designated by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting old revisions of checklist have been removed and replaced with new revisions.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 April 2005 Resolved
Vessel failed to report cracks in ballast tanks and main deck holed firemain using procedures in chapter 8 of ops manual. Correct to the satisfaction of RO designated by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting temporary repairs have been affected; permanent repairs to be affected points to be gauged and rewelded no later than 30 May 05.
Operations/Management › Ballast Water Managment › Extraordinary Condition Claims
Issued 8 April 2005 Resolved
Vessel has 5 cracks located in ballast tank 1p, 6p, 6s that have not been reported to class. Class to make inspection of all ballast tanks and submit copy of approved repair plan to MSO Philadelphia.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 10 April 2005
Resolution: Received class report attesting temporary repairs have been affected; permanent repairs to be affected points to be gauged and rewelded no later than 30 May 05.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 8 April 2005 Resolved
Vessel failed to report hazardous condition (cracks in cargo tanks) to USCG prior to arrival in US waters.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2005
Resolved 8 April 2005
Resolution: Received class report attesting temporary repairs have been affected; permanent repairs to be affected points to be gauged and rewelded no later than 30 May 05.
Fire Fighting › Combustible Materials › Insulation
Issued 2 April 2004 Resolved
STEAM TURBINE CARGO PUMP #1 FLANGE SHEILDING MUST BE REPLACED OR RENEWED. TEMPORARY SHIELDING IN PLACE AT PRESENT. LEGACY COMPONENT DESC: Insulation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2004
Resolved 27 July 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 2 April 2004 Resolved
MSD NEEDS TO BE PROPERLY MARKED AND PLACARDED AS PER 33 CFR 159.55(A)
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2004
Resolved 27 July 2004
Navigation › Collision/Grounding Avoidance
Issued 17 July 2002 Resolved
Vessel departed the Port of New York with an inoperable radar. Fax tech report attesting to proper repairs, prior to entering next US port. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2002
Construction/Loadline › Markings
Issued 28 March 2002 Resolved
Loadline to be re-painted in contrasting color to the vessel's hull color. LEGACY COMPONENT DESC: Load Line Mark
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2002
Resolution: WITNESSED SATISFACTORY LOADLINES. LOADLINES PAINTED IN CONTRASTING COLOR, WHITE ON DARK RED HULL.
Deck/Cargo
Issued 15 February 2000 Resolved
IAW SOLAS 74/78 ch.II-2 reg. 62 vessel must demonstrate proper operation of inert gas generator and all alarms and shutdown devices.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000

Ownership record