Records from 1981 to 2006. Most recent: inspection, 23 June 2006.
Inspection history · 82
23 June 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2689096
20 June 2005
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2396817
11 April 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2331422
7 December 2004
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2291247
9 March 2004
Annual Inspection · Internal Structural Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2021541
4 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1956842
2 April 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1766915
25 May 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1621751
8 April 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1602069
25 September 2001
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425241
15 August 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1069175
16 June 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448311
11 June 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448310
4 April 2001
COI Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391528
19 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 136399
4 April 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1365764
27 September 1999
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1033988
9 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 117517
12 March 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453557
5 March 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1105590
5 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438867
10 February 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 59434
30 July 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 153211
19 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 496293
26 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123759
10 April 1998
COI Inspection · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454619
5 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 464613
14 January 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664394
23 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446538
24 June 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469492
18 June 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1112125
13 March 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107074
18 June 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 144887
22 April 1996
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1080838
11 April 1996
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 885246
8 October 1995
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 881123
31 May 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 645171
16 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464042
7 March 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 29575
30 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367232
16 June 1994
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1331109
15 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 645159
18 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 480778
16 February 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1164275
1 February 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163222
6 July 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 540610
14 January 1993
Deficiency Check · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1137308
30 December 1992
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1141129
20 November 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 645144
14 November 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 503126
16 September 1992
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 950755
24 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448399
27 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957942
13 March 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954165
30 April 1991
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1217342
13 April 1991
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906879
22 February 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920922
9 January 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 927526
10 December 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 533287
10 June 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 484079
21 February 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 506056
2 January 1990
Examination of Repairs · Damage Survey · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 921535
16 August 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044328
31 July 1989
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 893498
3 March 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 472283
8 February 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1034114
13 January 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201246
29 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 494946
25 March 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300665
15 July 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 447845
4 March 1987
COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1316218
14 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 509939
25 November 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 453192
10 November 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 442583
10 September 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 519624
13 July 1986
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 986629
29 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299230
25 April 1986
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1306488
1 April 1986
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1305293
17 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271350
14 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964678
12 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969608
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 March 2004
Resolved
Prior to carrying cargo present the vesel for internal structural examination.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 18 March 2004
Construction/Loadline › Hull › Stiffener
Issued 9 March 2004
No resolution recorded
#1 port void, found server corrisiosin with several bottom longs wasted through, crop and renew swash bulkhead as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004 — due date passed with no resolution recorded
Construction/Loadline › Hull › Stiffener
Issued 9 March 2004
No resolution recorded
Bow void, pickup welds as marked and crop and renew bottom bracket at starboard side bilge knuckle at bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Construction/Loadline › Hull › Stiffener
Issued 9 March 2004
No resolution recorded
#2 starborad crop and renw aft WTB where crushed and crop and renew rolled bottom longs in way. Repair cargo tank leak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Construction/Loadline › Hull › Side Shell
Issued 9 March 2004
No resolution recorded
#1 starboard, repair cargo leak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 March 2004
No resolution recorded
Crop and renew swash bulkhead as marked in #2 port void, bay 2
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Construction/Loadline › Hull › Side Shell
Issued 9 March 2004
No resolution recorded
Gauge and reweld area on inset in #2 port void, bay 7 as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 March 2004
No resolution recorded
Crop and renew swash bulkhead as marked in #3 port void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 September 2001
Resolved
Remove temp patch, clean, gouge and reweld leaks on cargo tank weld seams.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Construction/Loadline
Issued 25 September 2001
Resolved
Crop and renew 8 10' sections of side long in voids #2 and # 3 stbd and #3 port.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Construction/Loadline
Issued 4 April 2001
Resolved
REPLACE GASKETS AS NEEDED ON VOID HATCH COVERS PORT AND STARBOARD SIDE.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Deck/Cargo
Issued 4 April 2000
Resolved
MAKE PERMANENT REPAIRS TO VENT PIPE ON NUMBER 1 CARGO TANK DOME, WHERE PIPEMEETS DOME. CROP AND RENEW PIPE AS NEEDED.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Fire Fighting
Issued 10 April 1998
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Documentation
Issued 23 September 1997
Resolved
Provide Approval Letter for installation, manufacturing of cargo pie extension located on stern of vessel. (Cargo transfer authorized prior to completion of Plan Approval. Construction testing and witnessing completedby TAMMS.
Condition: Unknown
Due 1 October 1997
Resolved 6 October 1997
Unknown
Issued 24 June 1997
Resolved
CONDUCT VESSEL'S REINSPECTION PRIOR TO 11JUN97 PER 46 CFR 31.10-17(a)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Lifesaving
Issued 16 June 1994
Resolved
PROVE TO [name withheld] HAVE BEEN CONDUCTED TO FRACTURE IN VESSELS BOX STERN VOID PORTSIDE.
Condition: Unknown
Due 22 June 1994
Resolved 20 June 1994
Lifesaving
Issued 16 June 1994
Resolved
PROVE TO [name withheld] HAVE BEEN MADE TO HOLES IN VESSEL'S FOREPEAK VOID.
Condition: Unknown
Due 22 June 1994
Resolved 20 June 1994
Deck/Cargo
Issued 30 December 1992
Resolved
THERMAL FLUID HEATER MODULATOR MOTOR MALFUNCTIONED. REPAIR OR REPLACE PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992
Deck/Cargo
Issued 30 December 1992
Resolved
#2 PORT WING VOID CONTAINED CARGO. REMOVE CARGO FROM VOID AND HAVE EXPOSEDCARGO TANK EXAMINED FOR LEAKS. REPAIR ANY DAMAGE DISCOVERED PRIOR TO LOADING CARGO BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992
Construction/Loadline
Issued 24 August 1992
Resolved
SEE NARRATIVE SUPPLEMENT (CASE MI92032697).
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Construction/Loadline
Issued 24 August 1992
Resolved
MAKE TEMPORARY REPAIRS TO 3 CRACKS AND HOLE LISTED IN REQUIREMENT #1 PRIOR TO DEPARTURE PASCAGOULS, MS/MOBILE, AL AND WITHIN 12 HOURS.
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Deck/Cargo
Issued 13 March 1992
Resolved
PROVE PROPER OPERATION OF THERMAL FLUID HEATER AND ITS REMOTE SHUTDOWN.-
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Construction/Loadline
Issued 13 April 1991
Resolved
GAS FREE MAKE AVAILBLE FOR INSPECTION: #1 PORT WING VOID. MAKE PERMENENT REPAIRS TO 2 DECK EDGE FRACTURES AND UPSET SIDE SHELL TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 13 April 1991
Resolved 13 April 1991
Construction/Loadline
Issued 9 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE 10" FRACTURE LOCATED BETWEEN THE TWO MOORING BUTTONS LOCATED ON THE PORT STERN CORNER.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THEFUEL OIL/AIR MODULATOR MOTOR AND TEST IAW THE CG APPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THETHERMAL FLUID HEATER PARTLOW TEMPERATURE CONTROL SYSTEM AND TEST IAW THE CGAPPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THETHERMAL FLUID HEATER REFRACTORY.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
INSTALL MISSING SAFETY GUARD ON THE THERMAL FLUID HEATER IN WAY OF THE DRIVE BELTS FOR THE UNIT BLOWER AND CIRCULATING PUMP.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
IN ACCORDANCE WITH THE APPROVED THERMAL FLUID HEATER TEST PROCEDURES MAKE _x001C_PERMANENT REPAIRS TO THE EXCESS TEMP. SWITCH WHICH WILL PREVENT THE OPERATING TEMPERATURE OF THE FLUID MEDIUM FROM EXCEEDING 400 DEGREES F. _x001C_(AT PRESENT TIME THE PHYSICAL STOP IS MISSING.)
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, DEMONSTRATE PROPER OPERATION OF THE THERMAL FLUID HEATER COIL TEMPERATURE SWITCHES. TEST IS TO BE CONDUCTED IAW THE CG APPROVED TEST PROCEDURES AND WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 31 July 1989
Resolved
MAINTAIN TEMPORARY REPAIRS UNTIL PERMANENT REPAIRS CAN BE MADE TO 6" FRACTURE IN BOTTOM PLATE AT BILGE KNUCKLE IN #5 PORT WING VOID.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989
Resolved
MAINTAIN TEMPORARY REPAIRS UNTIL PERMANENT REPAIRS CAN BE MADE TO 12" FRACTURE IN DECK GUNNEL IN WAY OF #2 STARBOARD WING VOID.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 13 January 1989
Resolved
MAINTAIN TEMPORARY REPAIR AND MAKE PERMANENT REPAIRS TO THE FORWARD STAR- BOARD CORNER OF THE BOW VOID AT NEXT GAS FREEING OF THE BOW VOID.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Deck/Cargo
Issued 13 January 1989
Resolved
CONDUCT BIENNIAL OPERATIONAL TEST OF THERMAL FLUID HEATER AND OPEN FOR INTERNAL INSPECTION PRIOR TO 15FEB89
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 4 March 1987
Resolved
BOW RAKE CORNER WRAPPER SPLIT. REWELDED SATISFACTORILY.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Deck/Cargo
Issued 4 March 1987
Resolved
FRACTURE IN #1 CARGO TANK STBD SIDE BOTTOM AT FRAME. GOUGED OUT & RE- WELDED. SATISACTORILY AIR TESTED.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Documentation
Issued 1 April 1986
Resolved
HAVE VESSEL'S LOAD LINE CERTIFICATE ENDORSED BY ABS OR PAINT OVER LOAD LINEMARKS. VESSEL MAY NOT TRANSIT ON THE LIMITED GREAT LAKES ROUTE UNLESS THE CERTIFICATED IS ENDORSED.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED CARGO TANK HATCH COVER GASKETS ON ALLCARGO TANKS.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
REPLACE EXISTING FLEXIBLE FUEL LINE HOSES WITH COAST GUARD APPROVED TYPE ONTHE DIESEL ENGINES.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
CONDUCT HYDRO TEST ON THE CARGO HOSE, STENCIL TEST DATE ON HOSE, AND LOGTEST RESULTS.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986