MAURY USCG vessel records
← All vessels

AT 1900

AT 1900 is a 1971 tank barge. The Coast Guard has recorded 71 inspections since 1983, most recently in April 2008, along with 42 deficiencies — 4 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2008.

Records from 1983 to 2008. Most recent: inspection, 14 April 2008.

Built
1971
Last inspected
14 April 2008
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 14 April 2008
…with no type recorded28
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1983–2008)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46804

Documentation record

Tonnage as PSIX records it1371 - Regulatory (Subpart C or D), Net Ton
1371 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 71

14 April 2008 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3191079
30 March 2008 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3174512
30 March 2008 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3175346
27 September 2007 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3066617
25 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2802235
19 September 2006 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2769229
10 June 2005 Examination of Repairs · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2389125
2 June 2005 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2377317
5 May 2005 Permit to Proceed
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2350962
30 November 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2250449
5 November 2004 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2251146
14 May 2004 Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2064197
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978901
27 June 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1825883
29 July 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1652468
25 July 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1366513
5 May 2000 Hull Examination · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1465577
12 December 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 442493
14 October 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1375934
23 September 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455764
15 June 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758372
22 May 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 195497
11 September 1998 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1395042
18 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 531309
15 July 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 656742
14 July 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 503167
12 December 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1116228
15 October 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 656730
26 September 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1123516
24 September 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422916
28 August 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 407467
4 November 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 152257
18 October 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1448829
2 August 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1089339
24 May 1996 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1085527
19 May 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 506289
30 October 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 37970
29 September 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455291
15 August 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 451633
17 July 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 875510
26 May 1995 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1357383
6 April 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358699
15 April 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 645155
18 March 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 480778
1 March 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164096
14 February 1994 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163675
3 February 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385192
15 April 1993 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 838956
7 April 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1147536
15 March 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358025
1 March 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 132528
6 February 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256918
17 June 1991 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 476200
20 May 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 539489
15 February 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1226133
25 September 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 439349
19 July 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 511815
29 March 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 465291
8 February 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235516
28 February 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201941
1 November 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 501513
11 March 1988 Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1336374
20 February 1988 Permit to Proceed
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1025218
22 January 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 471691
29 October 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1019133
31 March 1987 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1024942
1 April 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 482670
21 February 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297818
21 February 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312088
3 November 1984 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 439668
2 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271679

Deficiency record · 42

Construction/Loadline › Hull › Hull Plating
Issued 31 March 2008 No resolution recorded
Make permanent repairs as noted on the PTP issued 31 MAR by MSDDO Greenville.
Condition: Damaged By Earlier Event
Due 30 April 2008 — due date passed with no resolution recorded
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 September 2007 Resolved
Provide inspected fire extinguishers prior to transfer operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2007
Resolved 26 October 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 September 2007 Resolved
Properly clean the generator compartment
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 26 October 2007
Engineering › Pressure Vessel › Shell Plate
Issued 27 September 2007 No resolution recorded
Properly repair damage to thermal heater furnace shell plating.
Due 30 November 2007 — due date passed with no resolution recorded
Engineering › Pressure Vessel › Piping
Issued 27 September 2007 No resolution recorded
Properly repair holes in thermal heater piping exhaust system.
Action required: 705 - Other - as specified
Due 30 November 2007 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 September 2007 Resolved
Properly secure fuel lines from the diesel fuel tank to the generator compartment.
Due 27 October 2007
Resolved 26 October 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Adapters
Issued 27 September 2007 Resolved
Prove proper operation of #2 cargo tank indicator stick.
Due 27 October 2007
Resolved 26 October 2007
Electrical › Electric Generation Source (service) › Generator
Issued 27 September 2007 No resolution recorded
Prove proper operation of generator, thermal fluid heater and all emergency shut downs.
Due 30 November 2007 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2007 Resolved
Properly repalce light covers in generator compartment.
Due 27 October 2007
Resolved 26 October 2007
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 27 September 2007 Resolved
Properly connect electric connections from main circuit breaker to generator.
Due 27 October 2007
Resolved 26 October 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 19 September 2006 Resolved
Rubber mat missing from floor directly beneath the electrical distribution panel in the TFH & generator space.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 25 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 September 2006 Resolved
Improper use of plastic wire ties on overhead wire runs greater than 18" between metal supports.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 25 September 2006
Deck/Cargo › Cargo Heating › General
Issued 19 September 2006 Resolved
Thermal Fluid Heater safety devices could not be inspected becuase the Heater did not ignite after several attempts.
Action required: 705 - Other - as specified
Due 19 October 2006
Resolved 25 September 2006
Resolution: Sighted proper operation of installed safety devices.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 May 2005 Resolved
Vessel is prohibited from conducting cargo operations until the vessel completes an inspection for Certification of Inspection. Vessel was found to be sailing with an expired Certificate of Inspection. Vessel was not loaded with cargo. Owner/ Operator did not notify the cognizant OCMI that the vessel's COI had expired while the vessel was in transit. Vessel is to proceed to Greenville, MS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 24 June 2005
Resolution: Witnessed test procedure on thermal fluid heater. Replaced one safety switch since it was malfunctioning, retested all sat.
Deck/Cargo › Cargo Heating › General
Issued 5 November 2004 Resolved
Remove all Tamper devices and prove proper operation of all safety devices on the Thermal Fluid heater in accordance with 46 CFR 61.30-20
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2004
Resolution: Received tech rep report invoice #2940 from Mecanical Service Inc. attesting to proper operation of all safety''s.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 May 2004 Resolved
Provide labels for all motor controllers.
Due 25 May 2004
Resolved 14 May 2004
Resolution: Sighted by [name withheld]
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 May 2004 Resolved
Renew all panel directories.
Due 25 May 2004
Resolved 14 May 2004
Resolution: Sighted by [name withheld]
Fire Fighting › Portable CO2 Fire Extinguisher › Marine Type Label
Issued 14 May 2004 Resolved
Provide Coast Guard Approved CO2 type B-II extinguishers for barge.
Due 25 May 2004
Resolved 14 May 2004
Resolution: Sighted this date [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 14 May 2004 Resolved
Provide proof of annual testing of Cargo header, transfer hose, pressure gauge and relief valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Received by fax proof of testing. [name withheld]
Deck/Cargo › Cargo Heating › Valve
Issued 27 June 2003 Resolved
HOT STARTS. LOUD BANG EVERY TIME BOILER LIGHTS OFF. HAVE BOILER TECH FIX SAME AND TEST PRIOR TO MARINE INSPECTOR SHOWING UP FOR TESTS.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2003
Resolved 7 July 2003
Resolution: FOUND FAULTY CHECK VALVE THAT ALLOWED FUEL TO LEAK BACK TO SENSOR THROUGH LINE AND GROUND RICH START SENSOR.
Deck/Cargo › Cargo Heating
Issued 27 June 2003 Resolved
THERMAL FLUID HEATER CONTINUES TO START WITH RICH MIXTURE PRESENT. HAVE BOILER TECH FIX AND TEST PRIOR TO MARINE INSPECTORS ARRIVAL TO TEST. LEGACY COMPONENT DESC: THERMAL FLUID HEATER
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2003
Resolved 7 July 2003
Resolution: FOUND FAULTY CHECK VALVE. CORRECTED AND TESTED SAT.
Construction/Loadline › Hull
Issued 29 July 2002 Resolved
Soap/air test cracks in way of #5 stbd kevel (cleat) at base & doubler on stbd rake to determine whether or not these cracks extend into the hull. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2002
Resolution: Witnessed tests of cracked appurtenances. No leakage from hull detected. O/O welded cracks anyway to deter any further question.
Deck/Cargo › Cargo Heating
Issued 29 July 2002 Resolved
Replace missing fan guard on thermal fluid heater.
Condition: Improper/Lack of Maintenance
Due 29 August 2002
Resolved 8 August 2002
Resolution: Sighted replaced fan guard this date.
Deck/Cargo
Issued 23 September 1999 Resolved
Install and prove proper operation of Thermal fluid heater shutdown warninglight on exterior of machinery room
Condition: Unknown
Due 8 October 1999
Resolved 7 October 1999
Lifesaving
Issued 23 September 1999 Resolved
Replace emergency shutdown sign for cargo pump.
Condition: Unknown
Due 8 October 1999
Resolved 7 October 1999
Construction/Loadline
Issued 11 September 1998 Resolved
Make permanent repairs to #1 Starboard wing tank at aft bulkhead prior to loading next cargo and not later than 11 OCT 98 to the satisfaction of an attending Marine Inspector.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 24 September 1997 Resolved
Properly secure fwd Stbd electrical conduit and box by navigation light.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Deck/Cargo
Issued 24 September 1997 Resolved
Install and properly secure thermal piping insulation.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Fire Fighting
Issued 24 September 1997 Resolved
Install all fire extinguishers in racks or brackets.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Deck/Cargo
Issued 24 September 1997 Resolved
Properly secure diesel fuel return pipe between the diesel tank and_x001C_ generator room.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Documentation
Issued 28 August 1997 Resolved
CG officers on board T/B EMC-512 found a copy of the COFR that was not certified IAW 33 CFR 130.9.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Deck/Cargo
Issued 24 May 1996 Resolved
REPAIR/REPLACE CLUTCH ASSEMBLY PRIOR TO CARGO OPERATIONS AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Deck/Cargo
Issued 6 April 1995 Resolved
MAKE PV VALVES OPEN FOR INSPECTION BY CG INSPECTOR.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Construction/Loadline
Issued 6 April 1995 Resolved
PRIOR TO LOADING ANY CARGO, CONDUCT AN INTERNAL STRUCTURAL EXAMINATION.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Construction/Loadline
Issued 6 April 1995 Resolved
ALL REQUIRED HULL EXAMIANTIONS WILL BE CONDUCTED PRIOR TO THIS BARGE BEING PLACED IN SERVICE, ie... (INTERNAL STRUCTRAL EXAMINATION).
Condition: Unknown
Due 1 June 1995
Resolved 11 May 1995
Construction/Loadline
Issued 6 April 1995 Resolved
WHILE IN A LAID UP STATUS, THIS BARGE WILL BE BOARDED AND CHECKED FOR DAMAGE AND CARGO TANK INTEGRITY AT LEAST ONCE A WEEK BY AN OWNERS REPRESENTITIVE.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Engineering
Issued 6 April 1995 Resolved
REPLACE STACK ON BOILER/TFH SHACK.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Deck/Cargo
Issued 6 April 1995 Resolved
REPAIR HYDRALIC LEAK ON CARGO PUMP ENGINE, ENGAGER VALVE ON STARTER.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Deck/Cargo
Issued 3 February 1994 Resolved
CLEAN OIL SUMP UNDER DIESEL ENGINE PRIME MOVER.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Lifesaving
Issued 3 February 1994 Resolved
RESTENCIL "DANGER KEEP OUT" STENCILS ON WING VOIDS/TANKS.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 11 March 1988 Resolved
CARGO LEAKING THROUGH HAIRLINE FRACTURE IN LAP SEAM IN #1 CARGO TANK, STBD SIDE. FRACTURE GOUGED OUT,WELDED AND TANK SAT. AIR TESTED.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Deck/Cargo
Issued 11 March 1988 Resolved
THERMAL FIRED FLUID HEATER REFACTORY DETERIORATED, STACK WASTED. HEATER WAS REPLACED WITH REBUILT MODEL.(#CHI 70319)
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988

Casualty record · 1

30 March 2008Routine · role: Involved in a Marine Casualty · activity 3174512
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.