MAURY USCG vessel records
← All vessels

HMS 240

HMS 240 is a 1974 tank barge. The Coast Guard has recorded 81 inspections since 1982, most recently in July 2007, along with 28 deficiencies and 2 casualty investigations between 2003 and 2006.

Records from 1982 to 2007. Most recent: inspection, 20 July 2007.

Built
1974
Last inspected
20 July 2007
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 20 July 2007
…with no type recorded42
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1982–2007)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-48218

Documentation record

Tonnage as PSIX records it2157 - Regulatory (Subpart C or D), Gross Ton
2157 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 81

20 July 2007 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3001285
19 March 2007 Permit to Proceed
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2890449
4 April 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2616152
10 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2600038
3 March 2006 Administrative Inspection · Permit to Proceed
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2595131
1 June 2005 MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2366901
11 May 2004 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2064670
12 February 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005383
10 February 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005331
18 December 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2184290
21 May 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1797670
18 April 2002 Annual Inspection · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1602224
10 January 2002 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1477344
14 May 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1063543
9 March 2001 Examination of Repairs · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1369984
30 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 443240
29 October 2000 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 823316
25 April 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049262
21 April 2000 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049328
9 February 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792500
27 January 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1473570
15 December 1998 Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 807304
28 August 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426121
16 June 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 142002
27 January 1997 COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1419716
15 June 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 495904
1 February 1996 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1193014
23 January 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404069
2 April 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 459190
9 November 1994 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 536867
16 October 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 477158
16 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447353
12 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14555
12 May 1994 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377179
22 April 1994 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1400005
26 January 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423859
21 November 1993 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 488053
4 November 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 665649
1 November 1993 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 837716
25 October 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 450025
11 March 1993 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 356887
5 March 1993 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1146984
30 March 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 18751
22 March 1992 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 535855
9 March 1992 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 943504
6 March 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 485113
1 March 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 132528
1 March 1992 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1270567
29 January 1992 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1255911
19 December 1991 Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1265744
27 April 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 455369
16 December 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 515795
15 October 1990 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1229509
5 October 1990 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 491901
22 March 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 461883
10 January 1990 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 907331
13 December 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243099
31 October 1989 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 535851
20 March 1989 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 486281
20 January 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203279
2 November 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 893114
25 October 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1200818
6 September 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 529581
1 February 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 476629
29 January 1988 MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1322601
29 January 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1325665
7 November 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 438934
4 May 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 482227
31 December 1986 Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1308221
18 November 1986 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1018027
15 May 1986 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 497481
21 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999417
21 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996338
11 September 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 503246
6 March 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1285793
5 February 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 476117
9 December 1984 Type not recorded
No type recorded · MSO NASHVILLE · Activity 510841
1 December 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1283818
20 November 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 479430
6 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963827
8 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273420

Deficiency record · 28

Construction/Loadline › Hull › Hull Plating
Issued 3 March 2006 Resolved
Conduct guage readings of the wind/waterline and submit the findings to [name withheld] Provide structural strength analysis/calculations to MSC for approval prior to offloading barge.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 3 March 2006
Resolution: Recieved MSC approval of satisfactory guage readings demonstrating adequate structural strength for the offloading of the barge.
Construction/Loadline › Hull › Hull Plating
Issued 14 January 2002 Resolved
PERMANENTLY REPAIR 14 IN. FRACTURE LOCATED ON THE DECK KNUCKLE, IN THE VICINITY OF THE NR. 4 STARBOARD WING VOID.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2002
Resolved 14 January 2002
Resolution: DRILL STOPPED FRACTURE, GOUGED AND REWELDED, CONDUCTED VISUAL EXAM OF WELD AND WITNESSED SATISFACTORY AIR TEST.
Deck/Cargo
Issued 25 April 2000 Resolved
PRIOR TO OPERATING THE THERMAL FLUID HEATER OPEN FOR INTERNAL EXAM.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Deck/Cargo
Issued 25 April 2000 Resolved
THE CARGO LINE VALVE POSITION INDICATORS TO SHOW OPENED OR CLOSED DO NOT MEET 46 CFR 56.20-9(A). PROVIDE A WRITTEN PLAN TO MSO HOUSTON-GALVESTON STATING THE TYPE OF REPAIRS TO BE MADE AND WHEN IT WILL BE COMPLETED.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Deck/Cargo
Issued 25 April 2000 Resolved
PRIOR TO OPERATING THE THERMAL FLUID HEATER PROVE PROPER OPERATION OF ALL CONTROLS AND SHUTDOWNS AS PER 46 CFR 52.25-15 AND 46 CFR 61.30.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Deck/Cargo
Issued 27 January 1999 Resolved
PERFORM OPERATIONAL TEST OF THERMAL FLUID HEATER TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR PRIOR TO USE.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Deck/Cargo
Issued 27 January 1999 Resolved
REPAIR FLAME SCREENS ON #2 CARGO TANK AND THERMAL OIL TANK.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 23 January 1996 Resolved
Restencil "no smoking" sign.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Electrical
Issued 23 January 1996 Resolved
Label swithches on breaker panel at TFH.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Deck/Cargo
Issued 23 January 1996 Resolved
Provide lagging on TFH exhaust and cargo pipe discharge_x001C_ starboard side.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 12 May 1994 Resolved
CROP OUT AND RENEW APPROXIAMATELY 8 FOOT BY 8 FOOT INSERT ON RAKE BOW INCLUDING KNUCKLE ON STARBOARD SIDE TO REPLACE DAMAGE PLATING.
Condition: Unknown
Due 19 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 26 January 1994 Resolved
REMOVE OIL WATER SLOPS IN VOID SPACE UNDER THERMAL FLUID HTR SPACE.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Construction/Loadline
Issued 26 January 1994 Resolved
REPAIR VERTICAL CRACK ON FWD PORTSIDE OF HULL BY BOW VOID, 2FT DOWN FROM MAIN DECK, ABOVE WATERLINE WHEN IN LOADED CONDITION.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Deck/Cargo
Issued 26 January 1994 Resolved
THERMAL FLUID HTR PIPE LAGGING NEEDS REPLACEMENT.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Deck/Cargo
Issued 13 December 1989 Resolved
INSTALL FLAME SCREENS IN VENTS FOR DIESEL DECK TANK AND DAY TANK ON OPEN DECK ON STERN OF VESSEL. 46 CFR 32.55
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Deck/Cargo
Issued 13 December 1989 Resolved
REATTACH CONDUIT FOR PUMP ENGINE EMERGENCY SHUTDOWN CABLE TO WEATHER SHIELD46 CFR 32.50-35
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Construction/Loadline
Issued 25 October 1988 Resolved
MAINTAIN TEMPORARY REPAIRS TO 2 CRACKS IN PORT SIDE BOW RAKE IMMEDIATELY BELOW THE DECK IN WAY OF CAVEL AND MAKE PERMANENT REPAIRS TO THE SATISFAC- TORY OF THE COGNIZANT OCMI.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Deck/Cargo
Issued 25 October 1988 Resolved
REPAIR EMERGENCY SHUTDOWN AND TEST IN THE PRESENCE OF A MARINE INSPECTOR PRIOR TO LOADING NEXT CARGO.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Deck/Cargo
Issued 25 October 1988 Resolved
MAKE PERMANENT REPAIRS TO SOFT PATCH ON CONTAINMENT DRAIN LINE WHERE IT FLOWS BACK INTO CARGO TANK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Deck/Cargo
Issued 25 October 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Deck/Cargo
Issued 29 January 1988 Resolved
MAINTAIN TEMPORARY REPAIR TO #3 C.T. PV VALVE RISER. MAKE PERMANENT REPAIRAT NEXT GAS-FREEING BUT NOT LATER THAN 01 FEB 89.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Deck/Cargo
Issued 18 November 1986 Resolved
OPEN THERMAL FLUID HEATER FOR INTERNAL EXAM BY A COAST GUARD MARINE INSPECTOR. REPAIRS TO BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Deck/Cargo
Issued 18 November 1986 Resolved
OPEN AIR RECEIVER FOR INTERNAL EXAM BY A COAST GUARD MARINE INSPECTOR. REPAIRS TO BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Electrical
Issued 18 November 1986 Resolved
PROVIDE AND INSTALL ELECTRICAL PANEL BOX BLANK FOR GENERATOR SWITCH BOX. REPAIRS TO BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Deck/Cargo
Issued 18 November 1986 Resolved
RENEW THE RELIEF VALVE ON THE AIR RECEIVER. REPAIRS TO BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Electrical
Issued 18 November 1986 Resolved
PROVIDE AND INSTALL INSULATION ON THE GENERATOR EXHAUST SYSTEM. REPAIRS TO BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Deck/Cargo
Issued 18 November 1986 Resolved
REPLACE ALL PRESSURE-VACUUM VALVES AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986 Resolved
MAKE TEMPORARY REPAIRS TO THE PORT BOW RAKE SIDE SHELL BETWEEN FOUR FEET AND FIFTEEN FEET AFT OF THE HEADLOG UNTIL REPAIRS CAN BE MADE AT NEXT GAS FREEING OR PRIOR TO ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986

Casualty record · 2

18 December 2003Routine · role: Involved in a Marine Casualty · activity 2184290
10 March 2006Routine · role: Involved in a Marine Casualty · activity 2600038
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record