CARVER 5503 is a 1998 freight barge. The Coast Guard has recorded 24 inspections since 1998, most recently in April 2024, along with 2 deficiencies and 4 casualty investigations between 2007 and 2022.

Records from 1998 to 2024. Most recent: inspection, 12 April 2024.

Built
1998
Last inspected
12 April 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

470427
Flag
UNITED STATES
—
Maury page id
psix-470427

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (1998–2024)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)288.0 ft × 100.0 ft × 19.8 ft
Registered tonnagegross 4,422 / net 1,326
ITC dimensions (L × B × D)288.0 ft × 100.0 ft × 19.8 ft
ITC tonnagegross 4,422 / net 1,326
BuilderGULF COAST FABRICATION INC · PEARLINGTON, MS, UNITED STATES · built 1998
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOEYMANS, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 December 2025 · expires 31 January 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4422 - Convention (Subpart B), Gross Ton
1326 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 11

Inspection history · 24

12 April 2024 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893006
4 October 2022 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7571184
23 May 2022 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7459691
7 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6234423
20 July 2015 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5190243
12 January 2015 Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5059292
10 January 2015 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5054260
2 November 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5016967
30 October 2014 Re-Inspection · COI Inspection · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5015503
3 June 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4878631
14 June 2013 Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4620397
14 December 2010 MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3910991
21 July 2008 MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3275025
3 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3048266
28 May 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2946535
28 July 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2727868
6 July 2006 MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2703207
5 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2326963
21 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2263030
16 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2025711
29 September 2003 MARPOL Annex I Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1916595
2 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074735
5 April 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785879
11 June 1998 MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791867

Deficiency record · 2

Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 12 December 2014 Resolved
Provide remote fuel shut-offs for all 4 HPU's and both portable marine generators
Due 17 December 2014
Resolved 16 December 2014
Resolution: MI''s witnessed the satisfactory operation of all remote fuel shut-offs.
Construction/Loadline › Structures › Superstructure
Issued 12 December 2014 Resolved
Provide documentation attesting the approval by ABS of the following items: (a) Apron Extension, (b) Barge wing extension, (c) wing end cap assembly
Due 17 December 2014
Resolved 16 December 2014
Resolution: [name withheld] provided to our office ABS documentation attesting to the approval of the aforementioned systems.

Casualty record · 4

28 May 2007Routine · role: Involved in a Marine Casualty · at SR 1 BRIDGE (LAROSE) · activity 2946535
3 September 2007Routine · role: Involved in a Marine Casualty · activity 3048266
27 May 2013Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4604480
23 May 2022Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7459691
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

MARMAC 300 (2007–2013), CMT Y NOT 6 (2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.