Records from 1984 to 2015. Most recent: inspection, 6 January 2015.
Inspection history · 90
6 January 2015
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5048596
6 February 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4842633
20 January 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4787567
20 January 2014
Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4787803
18 October 2013
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4736817
15 October 2013
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4735002
9 October 2013
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4731233
4 December 2012
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4495671
14 November 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4483948
9 April 2012
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4283573
9 November 2011
Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4185758
26 October 2011
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4176227
8 October 2010
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3866110
24 March 2010
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3703207
3 October 2008
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3338068
8 April 2008
Internal Structural Exam · Hull Examination · Cargo Tank Internal · Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3179699
28 June 2007
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2976238
14 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2930161
16 September 2005
MTSA Verification · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2492555
29 October 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2231156
19 October 2004
MTSA Verification · Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2216390
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997731
30 December 2003
Periodic Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1971303
28 August 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1890085
8 May 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1789246
29 April 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1784263
19 February 2003
Hull Examination · Annual Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1746398
9 January 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1728111
4 November 2002
Drydock Extension
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1700879
13 December 2001
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1376801
2 October 2000
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1397541
4 December 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 216315
29 November 1999
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1440214
7 September 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 465347
2 October 1998
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1397000
17 September 1998
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 658833
15 September 1998
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 96029
15 September 1998
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1457599
21 April 1998
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 794429
18 December 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 440630
21 November 1997
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1388395
21 November 1997
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1461843
18 August 1997
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1404437
20 December 1996
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1094810
26 September 1996
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1402323
31 December 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 643027
15 November 1995
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 884278
15 November 1995
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1079989
8 November 1995
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1193169
30 October 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 190566
30 October 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 453502
5 January 1995
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 856608
30 September 1994
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1175843
6 September 1994
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1175622
12 July 1994
Damage Survey · Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1176893
6 December 1993
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1412584
28 July 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 447489
9 October 1992
Hull Examination · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 961665
13 January 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 451357
10 September 1991
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1244957
9 September 1991
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1252028
12 June 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 499767
8 December 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 482850
30 August 1990
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1230029
7 March 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 500453
7 November 1989
Re-Inspection · Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1336437
20 October 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1200722
17 October 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 333193
17 October 1989
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1347378
7 September 1989
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 889118
31 August 1989
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1044784
30 August 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 439411
27 February 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 518205
7 September 1988
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1040565
26 August 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 449238
21 December 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 447303
18 November 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 501826
6 October 1987
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1011599
30 September 1987
Hull Examination · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1013503
12 May 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 465885
20 February 1987
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1322428
9 January 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 489575
29 October 1986
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1319279
26 October 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 446737
8 October 1986
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1316191
11 September 1986
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1006588
21 March 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 474913
27 March 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 525885
21 September 1984
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1301039
12 August 1984
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 528147
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 10 October 2013
Resolved
Emergency shutdown was inoperable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2013
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 10 October 2013
Resolved
Rising stick was broken
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2013
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 October 2013
Resolved
Expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2013
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 9 October 2013
Resolved
P/V Valves required cleaning around seals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2013
Resolved 9 October 2013
Construction/Loadline › Hull › Side Shell
Issued 9 April 2012
Resolved
A 3"-4" fracture on the stbd bow rake knuckle approx at the 4' draft mark.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 13 April 2012
Resolution: Repaired damage with 24" X 18" insert. Inspection and air test sat.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 November 2011
Resolved
The danger keep out verbage on the hatches are faded and not legible.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Repainted hatch letters.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 November 2011
Resolved
Stern void hatch gasket is missing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Replaced hatch gasket.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 9 November 2011
Resolved
Remove diesel fuel from drip pans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Cleaned out drip pans.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 9 November 2011
Resolved
Replace missing valve handle on stbd drip pan drain line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Replaced valve handle.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 9 November 2011
Resolved
Red flag is dull and needs to be repainted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Painted red flag.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 November 2011
Resolved
Barge is documented and needs to add homeport to stern.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 16 November 2011
Resolution: Painted homeport on stern.
Construction/Loadline › Hull › Hull Plating
Issued 8 October 2010
Resolved
Provide proposal to complete hull gaugings from the last Hull Examination IAW 46 cfr 31-10.21a.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 8 October 2010
Stability › Unintentional Flooding › General
Issued 24 March 2010
Resolved
De-water the #2 starboard void which currently has 12 inches of water.
Action required: 705 - Other - as specified
Due 7 April 2010
Resolved 2 April 2010
Resolution: #2 starboard void space has been de-watered. The water in the space was cause by a hatch cover being left open during periods of rain.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 24 March 2010
Resolved
Vessel is to drain the containment for the above deck slop tank.
Action required: 705 - Other - as specified
Due 7 April 2010
Resolved 2 April 2010
Resolution: The slop tank containment has been drained and is dry.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 24 March 2010
Resolved
Vessel is to free up and make operational the dogs on the bow void hatch cover.
Action required: 705 - Other - as specified
Due 7 April 2010
Resolved 2 April 2010
Resolution: All dogs have had maintenance conducted and operated properly.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 April 2008
Resolved
Submit new Vessel Response Plan. (Mon River Towing gave barge back to Grandview Barge Line, Inc.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 2 September 2008
Resolution: CORRECTED
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 16 September 2005
Resolved
Emergency shut down cable was inoperable due to a lack of maintenance
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2005
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 September 2005
Resolved
#1 Port and Starboard cargo tanks have pin hole leaks approximately 2 feet below the top of the tanks.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 October 2004
Resolved
Renew/paint draft marks
Condition: Improper/Lack of Maintenance
Due 27 November 2004
Resolved 27 September 2005
Communications › Visual Communication › Red Warning Signal
Issued 19 October 2004
Resolved
Renew/paint red cargo transfer flag.
Condition: Improper/Lack of Maintenance
Due 27 October 2004
Resolved 19 October 2004
Resolution: Rcvd a fax from vsl rep attested flag was repainted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 19 October 2004
Resolved
Renew flame screen in gooseneck vent of box end void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2004
Resolved 19 October 2004
Resolution: Rcvd a fax in which vsl rep attested void flame screen had been installed.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 19 October 2004
Resolved
Provide an original or a notarized copy of the vessel's Certificate of Financial Responsibility
Condition: Improper Installation
Due 27 October 2004
Resolved 19 October 2004
Resolution: Rcvd a faxed, notarized copy of the COFR and vsl rep attested this copy was placed on board.
Documentation › Certificates/Documents
Issued 25 March 2003
Resolved
Provide a valid COFR onboard the barge. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 27 March 2003
Resolution: Provided COFR onboard vessel. MISLE indicated they had a valid one.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 25 March 2003
Resolved
Install a new gasket on the #3 port P/V valve.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 27 March 2003
Resolution: Gasket renewed. The gasket was torn when the P/V valve was disassembled for inspection.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 25 March 2003
Resolved
Renew pop-up gauge on number two port cargo tank.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 1 April 2003
Resolution: The pop-up rod was missing the magnetic end piece, the piece was retrieved from the guide and reattached to the rod.
Construction/Loadline › Markings
Issued 25 March 2003
Resolved
Renew paint on draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2003
Resolved 4 April 2003
Resolution: Draft marks painted white.
Construction/Loadline
Issued 15 September 1998
Resolved
Prior to any cargo ops make permanent repairs to the hole located on the bottom plating of the #1 stbd cargo tank just forward of the aft bulkhead.
Condition: Unknown
Due 15 October 1998
Resolved 7 October 1998
Deck/Cargo
Issued 21 November 1997
Resolved
INSTALL CARGO TANK OVERFILL DEVICES AS REQUIRED BY 33 CFR 155.480 TO BE ACCOMPLISHED PRIOR TO NEXT CARGO LOADING.
Condition: Unknown
Due 25 December 1997
Resolved 4 December 1997
Deck/Cargo
Issued 21 November 1997
Resolved
CONDUCT HYDRO TEST OF 2 SLOP TANKS IAW 46 CFR 58.50-10 (C).
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Construction/Loadline
Issued 20 December 1996
Resolved
REPAIR LEAK IN STERN BOX VOID.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 5 January 1995
Resolved
MAKE PERMANENT REPAIRS TO IMPACT DAMAGE, PUNCTURE TO HULL AND WALK-THRU BULKHEAD IN WAY OF #3 STBD WING VOID, 18" ABOVE BILGE KNUCKLE, 15' FWD OF AFT COLLISION BULKHEAD.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 12 July 1994
Resolved
PRIOR TO THE NEXT CARGO OPERATIONS, MAKE REPAIRS IN WAY OF MINOR IMPACT DAMAGE AT THE DECK TO SIDE SHELL LAP JOINT IN THE #1 STBD WING VOID IN THE AREA OF THE #3 DEEP FRAME.
Condition: Unknown
Due 30 July 1994
Resolved 21 July 1994
Construction/Loadline
Issued 20 October 1989
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGE TO THE PORT SIDE OF THE BOW RAKE, IN WAY OF THE MAIN DECK EDGE OF THE HEADLOG WRAPPER PLATE, EXTENDING 6' AFT FROM THE BOW (6'X 2.5' AREA), PRIOR TO LOADING CARGO.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Deck/Cargo
Issued 31 August 1989
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF CARGO PIPING IN ACCORDANCE WITH 46 CFR 35-35.70
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Construction/Loadline
Issued 29 October 1986
Resolved
PLACE VESSELS NAME AT THE HIGHEST PART OF THE VESSEL SO IT CAN BE SEEN FROMEITHER SIDE IAW 46 CFR 32.05-15.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Construction/Loadline
Issued 11 September 1986
Resolved
MAKE PERMANENT REPAIRS TO PUNCTURE STARBOARD BOW RAKE APPROX. ONE FOOT DOWN FROM MAIN DECK AND APPROX. 10 FEET AFT OF HEADLOG.
Condition: Unknown
Due 11 September 1986
Resolved 11 September 1986