Records from 1998 to 2026. Most recent: inspection, 28 April 2026.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 26.0 ft × 7.4 ft
Registered tonnagegross 118 / net 80
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENVILLE SHIPBUILDING CORP · GREENVILLE, MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Net Ton
118 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 47
28 April 2026
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8357453
11 October 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7982690
15 August 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7982083
23 June 2023
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7721554
30 December 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7623763
1 June 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7557442
4 February 2022
Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7411403
1 December 2021
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7360220
4 June 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6971074
5 January 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6890285
7 March 2019
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6637747
26 December 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6603647
19 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6544332
19 September 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6544671
17 April 2018
Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6394541
9 January 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6335530
14 September 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6012351
18 February 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5818193
30 January 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5073199
3 March 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4810604
22 February 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4805062
20 January 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4787567
11 June 2013
Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4617490
27 March 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4561682
22 March 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4555526
20 March 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4553558
17 December 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4503764
3 April 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4279542
31 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4237022
28 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4236552
25 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4231513
27 August 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4129842
8 June 2011
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4039265
26 May 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3759791
10 February 2010
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3684101
9 December 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3651714
7 September 2006
Uninspected Other
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2775331
28 May 2005
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2414204
18 April 2005
MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2337936
7 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2091368
3 November 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1848069
17 January 2002
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1479414
7 January 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 152548
5 December 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 18525
2 July 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 112829
7 May 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 22560
7 May 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 415728
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 October 2024
Resolved
Accurate broadcast of a properly assigned Maritime Mobile Service Identity (MMSI) number.
Towing Vessel's AIS MMSI or call sign did not match their FCC license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2024
Resolved 18 October 2024
Resolution: Received objective evidence FCC - AIS match. added to deficiency documents.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 September 2018
Resolved
The exhaust pipes from both the port and starboard MDEs located within easy reach of the entrance walkways to the engine room lack protective insulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Item cleared
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 September 2018
Resolved
During the cleanup of the bilges in the engine room excessive oil and sludge was splattered on both the port and starboard MDEs and the port and starboard generators. Remove excessive oil and sludge before getting underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2018
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 September 2018
Resolved
Each Towing vessel must be maintained and operated so as to minimize fire hazards; bilges must be kept free from accumulation of combustible and flammable materials; bilges in ER had excessive amounts of fuel and oil in bilge and on bilge plates throughout ER.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 October 2018
Resolution: Item cleared during follow up inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 September 2018
Resolved
All fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the manufacturer's approved design manual; Fire main was observed leaking excessively in engine room and spraying on #1 generator
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 September 2018
Resolution: Item cleared during follow-up inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 September 2018
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route; port and stbd stern void scuttle’s dogging mechanisms and gaskets were missing. Both voids were noted to have excessive water present approx 10" in each. 46 CFR 144.320 (b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 September 2018
Resolution: Item cleared during follow-up inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2018
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards and Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments; Starting solenoid conductor to starter was noted unhooked and laying in bilge. Crew could not identify why it was unhooked and whether it was energized when start switch was closed. 46 CFR 143.400
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 September 2018
Resolution: Item cleared during follow-up inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 19 September 2018
Resolved
The master must ensure that each crewmember who has not participated in the drills required by paragraph (a) of this section and received the instruction required by that paragraph (a) receives a safety orientation within 24 hours of reporting for duty. The safety orientation must cover the particular contingencies listed in paragraph (a) of this section. 46 CFR 142.245
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2018
Engineering
Issued 7 May 1998
Resolved
WHILE CONDUCTING EXAMINATION OF VESSEL FOUND OIL TRANSFER RECORDS DID NOT CONTAIN DESIGNATED PERSON IN CHARGE LISTING.
Condition: Unknown
Due 7 May 1998
Resolved 28 October 1998
Documentation
Issued 7 May 1998
Resolved
WHILE CONDUCTING EXAMINATION FOUND VESSELS OFFICIAL NUMBER WAS NOT CLEARLY VISIBLE ON INTERIOR STRUCTURE OF HULL.
Condition: Unknown
Due 7 May 1998
Resolved 28 October 1998
Fire Fighting
Issued 7 May 1998
Resolved
WHILE CONDUCTING EXAMINATION FOUND VESSEL DID NOT HAVE THE PROPER FIRE EXTINGUISHER METALLIC OR MYLAR NAME PLATE.
Condition: Unknown
Due 7 May 1998
Resolved 28 October 1998
Fire Fighting
Issued 7 May 1998
Resolved
WHILE CONDUCTING EXAMINATION OF VESSEL I FOUND THE ENGINE ROOM DID NOT ANY FIRE EXTINGUISHERS.
Condition: Unknown
Due 7 May 1998
Resolved 28 October 1998