Records from 1987 to 2022. Most recent: inspection, 1 March 2022.
Documentation record
Registered dimensions (L × B × D)75.5 ft × 26.0 ft × 9.5 ft
Registered tonnagegross 190 / net 130
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · OWENSBORO · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOUISVILLE, KY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it190 - Regulatory (Subpart C or D), Gross Ton
130 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
1 March 2022
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7403936
8 June 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7219647
19 August 2020
Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7037229
16 November 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6584247
19 September 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6544635
2 September 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6533847
3 March 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6367737
25 January 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6345974
21 December 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6066250
20 January 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4787567
18 April 2013
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4575925
15 August 2012
DAPI Audit · MTSA Verification · Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4411807
31 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4237041
17 October 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3617388
22 January 2009
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3398734
30 November 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3107470
15 April 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2908952
27 April 2005
MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2345562
30 June 2004
Security Plan Review - VSP
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2116398
25 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2110625
17 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2101676
29 May 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 316460
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 June 2021
Resolved
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The valve must be clearly marked by labeling or color coding that enables the crew to identify its function.
Vessel has a 4" hull penetration pipe below the water line STBD side FWD of the sewage discharge pipe, without a valve other approved / accepted means to ensure closure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 12 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2021
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Vessel was found with 3 gas cans stored on deck. Remove Fuel cans and install an approved flammable liquid storage cabinet that satisfies UL 1275.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 12 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2021
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Main power supply cable carrying the load form the port generator to the distribution panel was not supported to the overhead by a cable run. The main cable was held up by a C-clamp. Install adequate cable support.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 12 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2021
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Vessel had several extension cords run to provide additional power outlets for installed equipment. Remove extension cords and install wire runs and additional power outlets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 12 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 June 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Vessel used rope for the guard rails around the periphery of the deck. Remove rope and install with a material that provides strength and support equivalent to fixed rails.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 9 June 2021
Resolution: Operator sent in objective evidence attesting to the brake strength of the lifelines used for railings.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be
made available for a Coast Guard COI inspection within 90 days.
Action required: 705 - Other - as specified
Due 19 November 2020
Resolved 19 November 2020
Resolution: Initial Inspection for Certification completed.
15 April 2007Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · activity 2908952
4 February 2008Routine · role: Sighted in Area · activity 3145455
17 October 2009Routine · role: Sighted in Area · serious marine incident, as classified · 4 injured · activity 3617388
20 January 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4787567
21 December 2016Routine · role: Sighted in Area · activity 6066250
3 March 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6367737
16 November 2018Routine · role: Sighted in Area · activity 6584247
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.