Records from 2010 to 2025. Most recent: inspection, 17 November 2025.
Documentation record
Registered dimensions (L × B × D)54.2 ft × 28.0 ft × 7.0 ft
Registered tonnagegross 89 / net 71
ITC dimensions (L × B × D)54.2 ft × 28.0 ft × 7.0 ft
ITC tonnageNot recorded
BuilderCTCO SHIPYARD OF ALABAMA LLC · DEMOPOLIS, AL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Simplified, Gross Ton
71 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
17 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8269971
17 November 2025
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8285105
6 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8229388
22 May 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7917279
14 April 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7668547
13 June 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7627891
20 October 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7336445
30 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7214458
14 January 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7133988
13 February 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6908495
13 February 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6917211
26 November 2019
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 6865964
7 August 2019
Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6775602
4 October 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6555251
10 August 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6533326
26 July 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6492051
3 March 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6367737
17 January 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6388741
6 August 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5207404
2 March 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4930054
2 August 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4403582
19 April 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3992072
29 December 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3917309
10 November 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3889083
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 November 2025
Resolved
Port main engine was not responding to throttle commands.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2025
Resolved 21 November 2025
Resolution: Vessel was put on dry dock.Once the vessel was on dry dock it was discovered that the port tail shaft was broken causing the wheel to push into the rudder. The
port tail shaft has been removed and replaced with a spare.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 November 2025
Resolved
Vessel experienced a loss in steering.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2025
Resolved 21 November 2025
Resolution: Vessel went into drydock for repairs,
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 May 2024
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)).
MI observed the fire pump was found to be non-operational and failed to meet the regulatory pressure requirements due to electrical faults of the motor controller.
46 CFR 142.325(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2024
Resolution: RIO Marine attended vessel to replace and reprogram soft start motor controller. Tested fire pump, fire pump operated as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2021
Resolved
Propulsion machinery must be maintained to ensure proper operation.Vessel reported loss of port generator caused by a blown fuse.
Action required: 10 - Deficiency Rectified
Due 30 June 2021
Resolved 30 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel must have both main engines functioning properly.
33 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Due 13 February 2020
Resolved 13 February 2020
Resolution: Devall Diesel tech attended and operationally tested the engines in the presence of an ABS surveyor and the repair was considered to be permanent and satisfactory.
2 August 2012Routine · role: Involved in a Marine Casualty · activity 4403582
3 March 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6367737
10 August 2018Routine · role: Involved in a Marine Casualty · activity 6533326
14 January 2021Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 7133988
13 June 2022Routine · role: Involved in a Marine Casualty · activity 7627891
17 November 2025Routine · role: Involved in a Marine Casualty · activity 8285105
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.