MAURY USCG vessel records Sign in
← All vessels

KITION

KITION is a 1994 tank ship. The Coast Guard has recorded 37 inspections since 1998, most recently in February 2007, along with 13 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1998 to 2007. Most recent: operational control imposed, 10 February 2007.

Built
1994
Last inspected
10 February 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9074561 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
474293
Flag
UNITED STATES
—
Maury page id
psix-474293

Inspections, by type

…with no type recorded18
Years with a record 9 calendar years (1998–2007)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27269 - Convention (Subpart B), Net Ton
27269 - Regulatory (Subpart C or D), Net Ton
83678 - Dead Weight, Ton
53829 - Convention (Subpart B), Gross Ton
53829 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 8

Inspection history · 37

10 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2870144
10 February 2007 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2870153
1 February 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2865662
18 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2716770
11 June 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2676361
18 May 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2646586
28 April 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2635914
18 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2627649
29 March 2006 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2611815
10 March 2006 Ballast Water Examination · COC-TVE Renew · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2598618
27 February 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2592773
26 January 2006 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2574124
21 January 2006 Random ISPS/MTSA/PSC · Spot Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2571823
2 December 2005 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2545999
2 December 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2551472
29 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2443894
10 July 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2424553
10 March 2005 COC-TVE Annual · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2305028
1 March 2005 Random ISPS/MTSA/PSC
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2307476
28 February 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2301687
24 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2247561
10 November 2004 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2238275
1 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2232625
8 October 2004 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2217001
6 July 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2123872
3 June 2004 MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2087844
1 May 2004 Damage Survey · Administrative Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2059012
12 April 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2042216
14 March 2004 MARPOL Annex V Examination · MARPOL Annex I Examination · Certificate of Compliance · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2024106
24 November 2002 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1711152
5 May 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1611119
5 October 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 294054
25 July 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 280014
25 July 2000 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1052332
4 June 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 429066
6 November 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 421886
23 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417849

Deficiency record · 13

Navigation › Collision/Grounding Avoidance › Radar
Issued 11 June 2006 Resolved
Speed Log defect is to be identified and rectified. Based on request from the owner's representative due to incorrect parts received, the requirement date is postponed by the class society to 15 Jul 2006.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 18 July 2006
Resolution: Received technician''s report attesting to repairs and proper operation of speed log.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 March 2006 Resolved
Radar is operational, but speed log is inoperable. Must affect permanent repairs to speed log by specified date and to the satisfaction of SOLAS Cargo Ship Safety Equipment Certificate issuing authority (DNV).
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 11 June 2006
Resolution: Received class report from Det Norske Veritas postponing due date for the condition of class to 15 July 2006. Deficiency will be reissued to reflect the change in date due.
Construction/Loadline › Structures › Superstructure
Issued 26 January 2006 Resolved
July 2005, vessel was involved in collision in Galvestion Lighterin Area. Resulted in buckling of Port Bridge wing. Class initially issued condition to expire NLT 11OCT05, and extended twice until 31Jan06. Repairs are now being conducted at Pier 10, Port of Galveston to be completed around 02Feb06.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 10 February 2006
Resolution: Received copy of class report that the vessel repairs are to the satisfaction of certificate issuing authority and the vessel''s hull in class. The condition of class is now "DELETED"
Construction/Loadline › Structures › Superstructure
Issued 26 January 2006 Resolved
In Oct 2005 vessel was in collision in Galveston Lightering area. Damaged port side cargo hose crane. Repairs are being completed now and should be completed by 02FEB06.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 10 February 2006
Resolution: Received copy of class report that the vessel repairs are to the satisfaction of certificate issuing authority and the vessel''''s hull is in class. The condition of class is now "DELETED"
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 21 January 2006 Resolved
Loadline markings were rusted and not in contrasting color to hull.
Action required: 705 - Other - as specified
Due 28 January 2006
Resolved 26 January 2006
Resolution: Load line painted with in Regulations
Construction/Loadline › Hull › Bottom Plating
Issued 2 December 2005 Resolved
Vessel ran aground in the Houston Ship Channel. Issued a Port State Control Form B requiring that the Certificate Issuing Authority provide attestation that the hull is within class.
Action required: 705 - Other - as specified
Resolved 3 December 2005
Resolution: Class ,Det Norske Veritas, issued a survey report. A condition of class was issued to carry out an in-water damage survey for possible damage by 02 January 2006.
Construction/Loadline › Hull
Issued 1 May 2004 Resolved
Damage to hull plating port side between frames 54 & 55 immediately below the 15th longitudinal measured from the main deck. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Resolved 2 May 2004
Deck/Cargo › Inert Gas System
Issued 13 March 2004 Resolved
Vessel to calibrate or provide evidence of calibration for instrumentation on main IG panel in cargo control room. SOLAS 74 Ammended/II-2/62/16 LEGACY COMPONENT DESC: IG Instrumentation Panel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2004
Resolved 12 April 2004
Resolution: Flag state attest to clear via fax from Clinton Wolfe.
Deck/Cargo › Vapor Control Systems
Issued 13 March 2004 Resolved
Vessel could not provide diagram/drawings for High Velocity Vents showing required # and required flame screen mesh for vacum side. Noted most vents to have (2) 30x30's installed w/ spacer. Slop tank noted to have something between 20x20 and 30x30. LEGACY COMPONENT DESC: Vessel Vapor Overpressure/Vacuum Protection
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2004
Resolved 12 April 2004
Resolution: Flag state attest to clear via fax from Clinton Wolfe
Deck/Cargo › Vapor Control Systems
Issued 13 March 2004 Resolved
Noted several Flame Screens to be holed. Check and replace all screens. SOLAS 74 Ammended/II-2/Reg. 59
Action required: 705 - Other - as specified
Due 13 April 2004
Resolved 12 April 2004
Resolution: Flag state attest to clear via fax from Clinton Wolfe.
Construction/Loadline
Issued 5 October 2001 Resolved
Oil product was discovered in the ballast tank. Vessel restricted from entering US Ports without class report of permanent repairs._x001C_ _x001C_ 33 CFR 157.222(c)
Condition: Unknown
Due 6 October 2001
Resolved 5 May 2002
Resolution: Received Class Survey report. All deficiencies corrected.
Construction/Loadline
Issued 4 June 1999 Resolved
Requirement to have DNV classification society evaluate and provide a written recommendation to the USCG in Portland, ME as to the structural integrity and water-tightness to the starboard cargo pumproom door and bulkhead.
Condition: Unknown
Due 15 July 1999
Resolved 15 July 1999
Deck/Cargo
Issued 6 November 1998 Resolved
Make permanent repair to port anchor and provide Class Society attestation of satiafactory repair prior to return to next U.S. Port.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.