This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
10696 - Convention (Subpart B), Gross Ton
3208 - Convention (Subpart B), Net Ton
Maury page id
psix-47489
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 November 2019Resolved
Ventilator openings shall be provided with weathertight closing appliances. PSCO observed multiple ventilator openings with missing or damaged closing appliances.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2021
Resolution: Ventillation covers were found in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 November 2019Resolved
Satisfactory means, permanently attached, shall be provided for closing the openings of the air pipes. PSCO observed multiple ballast tank vents and fuel oil tank vents with missing or damaged closing appliances.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2021
Resolution: Tank vents were found to be in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 August 2018Resolved
1299- Other (Load Lines) – Ships with mechanical means of propulsion or lighters, barges or other ships without independent means of propulsion, shall be assigned freeboards in accordance with the provisions of regulations 1-40 inclusive in this Annex. PSCO observed wastage on ventilators, railings, and on weather tight doors on the vessel's main deck. ILLC 66am Annex I / Reg. 2 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 3 August 2018
Resolved 5 August 2018
Resolution: Received, reviewed and accepted class report from ABS stating the deficiency was rectified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 3 August 2018Resolved
2120- Garbage – Every ship of 400 tons gross tonnage and above, and every ship which is certified to carry 15 persons or more, shall carry a garbage management plan which the crew shall follow. PSCO observed garbage not stored or segregated in accordance with the garbage management plan throughout the vessel. MARPOL Annex V / Reg. 9.2 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2018
Resolved 18 October 2021
Resolution: Garbage maganement plan not applicable due to nature of vessel's operation. Flag attestation letter uploaded in documents.
Navigation
Issued 2 April 1990Resolved
INSTALL MARINE TYPE, APPROVED LIGHT BULBS IN PORT, STARBOARD, AND STERN RUNNINGS LIGHTS
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering
Issued 2 April 1990Resolved
INSTALL 30"X 30" FLAME SCREENS IN ALL FUEL OIL VENTS ON MAIN DECK
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Construction/Loadline
Issued 27 April 1988Resolved
PROPERLY SECURE NETTING AROUND HELO DECK.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Navigation
Issued 27 April 1988Resolved
CALIBRATE GYRO TO OPERATE PROPERLY.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Electrical
Issued 27 April 1988Resolved
CONDUCT TEST OF EMERGENCY GENERATOR LOW OIL PRESSURE/ALARM SHUTDOWN.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Unknown
Issued 27 April 1988Resolved
PROVIDE UPDATED APPROVED COPY OF GENERAL ARRANGEMENT PLAN TO REFLECT CHANGES IN LIFERAFT STATIONS.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Engineering
Issued 28 May 1987Resolved
MAKE PERMANENT REPAIRS TO BOTTOM HAND HOLE AND CONDUCT 1 1/4 MAWP HYDROSTATIC TEST ON LOW PRESSURE HEATING BOILER.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Documentation
Issued 28 May 1987Resolved
PROVIDE VALID LOAD LINE CERTIFICATE. THE ABOVE REQ. ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI BY 28MAY87.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Electrical
Issued 28 May 1987Resolved
MAKE PERMANENT REPAIRS TO NO.2 MAIN SHIP SERVICE GENERATOR AND TEST THE OVERSPEED TRIP AND REVERSE POWER RELAY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 28 May 1987Resolved
MAKE PERMANENT THE NEW OILY WATER BILGE PIPING INSTALLATION AND TEST OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987