Records from 1987 to 2021. Most recent: inspection, 18 October 2021.
Inspection history · 27
18 October 2021
Loadline Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7335144
26 November 2019
MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · Loadline Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6861901
3 August 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6500566
4 January 2018
PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6325886
29 June 2017
Ballast Water Examination · Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6190748
4 April 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4829854
3 April 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4833443
10 December 2012
PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4496708
13 July 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3027743
20 February 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2593021
24 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 70748
29 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139511
4 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665582
9 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69693
7 March 1991
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1243392
2 May 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 900221
2 April 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1216963
19 July 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1202638
17 May 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1343893
28 April 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 895366
26 August 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038672
28 May 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1194350
27 April 1988
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341523
9 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1327374
28 May 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1026000
26 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1325075
19 March 1987
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1018634
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 November 2019
Resolved
Ventilator openings shall be provided with weathertight closing appliances. PSCO observed multiple ventilator openings with missing or damaged closing appliances.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2021
Resolution: Ventillation covers were found in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 November 2019
Resolved
Satisfactory means, permanently attached, shall be provided for closing the openings of the air pipes. PSCO observed multiple ballast tank vents and fuel oil tank vents with missing or damaged closing appliances.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2021
Resolution: Tank vents were found to be in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 August 2018
Resolved
1299- Other (Load Lines) – Ships with mechanical means of propulsion or lighters, barges or other ships without independent means of propulsion, shall be assigned freeboards in accordance with the provisions of regulations 1-40 inclusive in this Annex. PSCO observed wastage on ventilators, railings, and on weather tight doors on the vessel's main deck. ILLC 66am Annex I / Reg. 2 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 3 August 2018
Resolved 5 August 2018
Resolution: Received, reviewed and accepted class report from ABS stating the deficiency was rectified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 3 August 2018
Resolved
2120- Garbage – Every ship of 400 tons gross tonnage and above, and every ship which is certified to carry 15 persons or more, shall carry a garbage management plan which the crew shall follow. PSCO observed garbage not stored or segregated in accordance with the garbage management plan throughout the vessel. MARPOL Annex V / Reg. 9.2 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2018
Resolved 18 October 2021
Resolution: Garbage maganement plan not applicable due to nature of vessel's operation. Flag attestation letter uploaded in documents.
Navigation
Issued 2 April 1990
Resolved
INSTALL MARINE TYPE, APPROVED LIGHT BULBS IN PORT, STARBOARD, AND STERN RUNNINGS LIGHTS
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering
Issued 2 April 1990
Resolved
INSTALL 30"X 30" FLAME SCREENS IN ALL FUEL OIL VENTS ON MAIN DECK
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Construction/Loadline
Issued 27 April 1988
Resolved
PROPERLY SECURE NETTING AROUND HELO DECK.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Navigation
Issued 27 April 1988
Resolved
CALIBRATE GYRO TO OPERATE PROPERLY.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Electrical
Issued 27 April 1988
Resolved
CONDUCT TEST OF EMERGENCY GENERATOR LOW OIL PRESSURE/ALARM SHUTDOWN.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Unknown
Issued 27 April 1988
Resolved
PROVIDE UPDATED APPROVED COPY OF GENERAL ARRANGEMENT PLAN TO REFLECT CHANGES IN LIFERAFT STATIONS.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Engineering
Issued 28 May 1987
Resolved
MAKE PERMANENT REPAIRS TO BOTTOM HAND HOLE AND CONDUCT 1 1/4 MAWP HYDROSTATIC TEST ON LOW PRESSURE HEATING BOILER.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Documentation
Issued 28 May 1987
Resolved
PROVIDE VALID LOAD LINE CERTIFICATE. THE ABOVE REQ. ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] 28MAY87.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Electrical
Issued 28 May 1987
Resolved
MAKE PERMANENT REPAIRS TO NO.2 MAIN SHIP SERVICE GENERATOR AND TEST THE OVERSPEED TRIP AND REVERSE POWER RELAY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 28 May 1987
Resolved
MAKE PERMANENT THE NEW OILY WATER BILGE PIPING INSTALLATION AND TEST OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987