Records from 1994 to 2026. Most recent: inspection, 22 February 2026.
Documentation record
Registered dimensions (L × B × D)98.5 ft × 34.0 ft × 17.0 ft
Registered tonnagegross 107 / net 73
ITC dimensions (L × B × D)98.5 ft × 34.0 ft × 17.0 ft
ITC tonnagegross 389 / net 116
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it389 - Convention (Subpart B), Gross Ton
107 - Regulatory (Subpart C or D), Gross Ton
116 - Convention (Subpart B), Net Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 43
22 February 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8314066
12 April 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7894018
13 March 2024
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7875938
11 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7666485
28 March 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658439
8 November 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7591207
7 July 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7500656
2 June 2022
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7590908
5 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7424781
17 February 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397884
8 December 2021
Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7364569
11 July 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7253319
10 July 2021
Annual Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7254129
9 August 2020
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7042361
22 July 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758247
28 November 2018
Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6638239
13 October 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6564568
7 March 2017
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6100721
12 May 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5124625
5 March 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4811607
18 February 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4801414
5 February 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4795627
17 January 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4788266
1 November 2012
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4477008
24 November 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4206392
13 October 2011
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4172867
5 October 2011
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4162498
22 November 2010
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3896615
10 November 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3888894
10 November 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3889185
8 January 2009
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3393849
25 December 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3385766
2 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2791623
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997589
21 May 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1819992
18 March 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1719989
21 November 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 189678
21 November 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 768845
29 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139511
26 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 655853
22 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 117145
22 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 225215
19 June 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 131527
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2026
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions or the Towing Safety Management System (TSMS) applicable to the vessel. Crack identified on the channel cooler for the port main engine cooling system. TPO via TSMS to attend vessel for permanent repairs.
46 CFR 143.245(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2026
Resolved 6 March 2026
Resolution: ABS report submitted. Welded 02 cracks in channel coolers. No leaks detected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2024
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable extinguishers required by tables 142.230. Vessel currently has only 10-B:C extinguishers at the paint and flam lockers. Upgrade and mount both extinguishers to 40-B portable extinguishers to the satisfaction of the Third Party Organization (TPO).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2024
Resolved 12 April 2024
Resolution: Received ABS report/finding 281.0, stating 40:BC extinguishers were installed at paint and flammable storage lockers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2021
Resolved
Both MDE's shut down and vessel lost propulsion while in tow. Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation; (2) Be suitable for route and service; and (3) Have suitable propulsion controls to provide the operator full control at each operating station.
Vessel may navigate to Wilmington anchorage. Prior to exiting the anchorage vessel must notify the Sector Delaware Bay Command Center of their intended mooring plan.
143.205(c)
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2021
Resolved 11 July 2021