MAURY USCG vessel records Sign in
← All vessels

APL TOURMALINE

APL TOURMALINE is a 1995 freight ship. The Coast Guard has recorded 50 inspections since 1998, most recently in April 2016, along with 23 deficiencies and 5 operational controls.

Records from 1998 to 2016. Most recent: inspection, 19 April 2016.

Built
1995
Last inspected
19 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9082336 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
475849
Flag
SINGAPORE
—
Maury page id
psix-475849

Inspections, by type

…with no type recorded24
Years with a record 16 calendar years (1998–2016)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52086 - Convention (Subpart B), Gross Ton
28998 - Convention (Subpart B), Net Ton
52086 - Simplified, Gross Ton
81881 - Displacement, Metric Ton
60323 - Dead Weight, Metric Ton
28998 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FLORIDA Towing Vessel · MISLE 76143 · 25 September 2015 · activity 5729220SAVANNAH Towing Vessel · MISLE 569604 · 25 September 2015 · activity 5729220KYOTO EXPRESS Freight Ship · MISLE 1064914 · 25 September 2015 · activity 5729220

Inspection history · 50

19 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5857453
7 March 2016 Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828294
1 December 2015 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5774167
25 September 2015 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5729220
19 May 2014 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4862932
17 December 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4209859
16 December 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4209833
16 December 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4218019
9 February 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3942001
26 March 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3703306
2 March 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3686457
28 March 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3441743
27 March 2009 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3441097
12 February 2009 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3416293
19 July 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3272417
5 June 2008 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3228003
11 September 2007 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3054897
24 May 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2939488
21 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2936240
16 January 2007 Random ISPS/MTSA-No PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2856450
26 October 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2808356
14 September 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2778402
13 September 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2777589
12 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2776109
7 March 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2597680
3 March 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2595293
3 September 2005 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2482463
19 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2432016
19 July 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2432068
29 April 2005 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2345882
19 March 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2314326
4 February 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2286854
22 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2279152
22 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2279714
5 August 2004 PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2156932
18 April 2004 MTSA/ISPS Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2046408
6 March 2004 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2019351
21 February 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2010443
16 July 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1847916
27 June 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1828381
24 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1762300
28 November 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1711985
23 July 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1650624
7 July 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1642118
17 June 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1632298
14 July 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 280030
1 February 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274287
1 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 430273
3 March 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 426149
19 June 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416738

Deficiency record · 23

Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 March 2016 Resolved
74SOLAS (97) CH.II-1 REG 45.1.3 All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Multiple junction boxes were not properly insulated to prevent from shock throughout vessel. 40ac.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 April 2016
Resolution: Received [name withheld] stating that the current condition was satisfactory and no corrections were required to be made, see attached class report.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2011 Resolved
0950 ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. ELECTRICAL WIRING IN ENGINE ROOM ABOVE OIL CONTENT METER AND NEAR STAIRWELL ON SECOND FLOOR AFT OF ENGINE WERE ATOINED (SPLICED) TOGETHER. SOLAS 74(04CONS.) CH.II-1 REG. 45.1.3 50(A/C)
Condition: Improper/Lack of Maintenance
Due 11 March 2011
Resolved 7 April 2011
Resolution: ABS Surrvey Report: The defective eletrical cable was replaced with new one (About 12000mm in length) visually examined and considered satisfactory.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 February 2011 Resolved
2050 ALL STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION. STEERING SYSTEM HAS EXCESSIVE DEVIATION DURING STEERING TEST. SOLAS 74(04 CONS.) CH.II-1 REG. 29.2.1 17(A/C)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2011
Resolved 9 February 2011
Resolution: Cheif Engineer reviewed steering gear manual and determined that steering system had faulty settings, after adjustments were made steering modes were re-tested and proved to be in working order to the satisfaction of the attending CG inspectors.
Engineering › Lubricating Oil Service System › Piping
Issued 9 February 2011 Resolved
1799 A SHIP WHICH UNDERGOES REPAIRS, ALTERATIONS, MODIFICATIONS SHALL COMPLY WITH THE PREVIOUS APPLICANT REQUIREMENTS. LUBE OIL DRAIN LINE FROM SETTLING TANK HAS BEEN FOUND WITH A TEMPORARY REPAIR. ICLL ARTICLE 10.1 50(A/C)
Condition: Improper Installation
Due 11 March 2011
Resolved 7 April 2011
Resolution: ABS Survey Report: he soft patched drain pipe was replaced with new one (40Ax1000mml), visually examined and pressure tested with a normal working pressure and considered satisfactory.
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 2 March 2010 Resolved
All dangerous cargo manifests must contain nationality of vessel, emergency response telephone number and a signature to certify the truth and accuracy of the information. The vessels current dangerous cargo manifests are not in compliance with these regulations. Rectify deficiency prior to next US port after sailing foreign to the satisfaction of the Coast Guard 49CFR 176.30
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 March 2010
Resolved 26 March 2010
Resolution: Received faxed copy of DCM from the Captain, the DCM meets the above deficiency.
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 2 March 2010 Resolved
All vessels must comply with LRIT requirments and have the compliance attested to by class on "Form E" of SOLAS cargo ship safety equipment certificate after verified by a conformance test report. Vessels current "Form E" does not reflect LRIT system. Rectify deficiency prior to next US port after sailing to the satisfaction of class. SOLAS 74 (2006 con) Ch V reg 19-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2010
Resolution: Recieved Form E of the SOLAS Cargo Ship Safety Equipment Certificate with LRIT equipment marked as provided. deficiency cleared
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 February 2009 Resolved
1400: The following items were noted 1) Suction line for GS svc pump patched. 2) Heeling discharge/supply line patched. 3) Steering leakage of oil at controls and rams 4) Purifier room - longitudinal frame and brackets are bent. 5) Air conditioning intake duct are holed and has minor wastage. 6) Forward eductor pipe is patched.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 27 March 2009
Resolution: Received Class Report. All Sat.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 12 February 2009 Resolved
0950: The company must supply the crew with documentation stating that the electrical matting around switchboard and electrical panels meet SOLAS safety requirement.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 27 March 2009
Resolution: Received Class Report. All Sat.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 February 2009 Resolved
1470: The crew overfilled the HFO tank and it appears the insulation between the tank and outside sheet metal has been saturated with oil. The crew has been cleaning oil from the deck for sometime; however the insulation may need replacing. Class must inspect.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 27 March 2009
Resolution: Received Class Report. All Sat.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 12 February 2009 Resolved
2055: The crew has been incinerating more than just oily rags. Metal, gaskets, and welding rods were found inside the incinerator. In addition, the location and collection of batteries and fluorescent lights are not well identified in the garbage plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 12 February 2009
Resolution: Discussed with Captain, Chief Engineer, and [name withheld].
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 11 September 2007 Resolved
Ship provided incorrect birthday for [name withheld] on the ANOA. Vessel is to submit an update to the National Vessel Movement Center with correct birthday.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2007
Resolved 11 September 2007
Resolution: Corrected while onboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 11 September 2007 Resolved
Ship did not enter garbage receipt for port of Chinan 21 July 2007. Update garbage log book to reflect this discharge.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2007
Resolved 11 September 2007
Resolution: Corrected while onboard.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 26 October 2006 Resolved
Burning more than oily rags/paper in incinerator as was specified. Remnants of plastics and gasket materials found.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 December 2006
Resolution: Use of the Incinerator and what can and can not be burned have been expanded in great detail in the Garbage Plan.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 26 October 2006 Resolved
Garbage plan was not ship specific. Location of garbage containers not specified in plan. No color coding system for cans specified in plan or adhered to by crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 December 2006
Resolution: The Garbage Plan has been re-written to explain the color coding of containers and what and where to store garbage.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 26 October 2006 Resolved
Excess paint stored in port side aft tunnel. No appropriate fire extinguishing equipment installed in this area.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 December 2006
Resolution: All of the excess paint has been removed from this location. The company will only purchase enough paint that can be stored in the paint locker.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 October 2006 Resolved
Pipe leading from upper stage level to lower level on OWS was patched. No report made to Chief Engineer/Company DPA, which is not in accordance with ISM code.
Action required: 705 - Other - as specified
Resolved 26 October 2006
Resolution: Resolved by Master/ Chief Engineer submitting a non-conformity report and making repairs as per SMS.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 October 2006 Resolved
#4 generator cooling pipe to turbo-charger was patched. No report made to Chief Engineer/Company/DPA, which is not in compliance with ISM code.
Action required: 705 - Other - as specified
Resolved 26 October 2006
Resolution: Resolved by Master/ Chief Engineer submitting a non-conformity report and making repairs as per SMS.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 October 2006 Resolved
Generator fuel-oil line was patched and leaking. No report made to Chief Engineer/Company representative, which is not in accordance with ISM code.
Action required: 705 - Other - as specified
Resolved 26 October 2006
Resolution: Resolved by Master/ Chief Engineer submitting a non-conformity report and making repairs as per SMS.
Fire Fighting › Fire Main › Condition
Issued 26 October 2006 Resolved
Salt water pipe in paint locker was holed and patched with electrical tape. No report was made to [name withheld]/Company representative, which is not in accordance with the ISM code.
Action required: 705 - Other - as specified
Resolved 26 October 2006
Resolution: Resolved by Master/ Chief Engineer submitting a non-conformity report and making repairs as per SMS.
Fire Fighting › Emergency Fire Pumps
Issued 27 June 2003 Resolved
EMERGENCY FIREPUMP MISSING GUARD FOR BELT TO PRIMING PUMP.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 July 2003
Resolution: GUARD WAS REINSTALLED.
Fire Fighting › Emergency Fire Pumps
Issued 27 June 2003 Resolved
EMERGENCY FIREPUMP DISCHARGE PRESURE GUAGE BROKEN. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2003
Resolution: DISCHARGE PRESSURE GAUGE WAS RENEWED.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 June 2003 Resolved
MAIN DIESEL ENGINE HAS LUBE OIL LEAK AFT, LEAKING INTO RIGGED CONTAINMENT SYSTEM, AND THEN INTO A 5 GALLON BUCKET. LEGACY COMPONENT DESC: Crankcase
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2003
Resolution: CONTAINMENT SYSTEM REMOVED AND LEAKAGE FIXED.
Fire Fighting › Fixed Fire Detection System
Issued 27 June 2003 Resolved
ENSURE FIRE ALARM/SMOKE ALARM NEXT TO PARTS CLEANING ROOM IS OPERATIONAL. LEGACY COMPONENT DESC: Heat Detectors
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2003
Resolution: SMOKE DETECTION AND ALARM TESTED AND SATISFACTORY.