MAURY USCG vessel records
← All vessels

NICOLE C

NICOLE C is a 1973 tank barge. The Coast Guard has recorded 117 inspections since 1980, most recently in April 2010, along with 85 deficiencies and 1 casualty investigation in 2008.

Records from 1980 to 2010. Most recent: inspection, 21 April 2010.

Built
1973
Last inspected
21 April 2010
Documentation
No Operation - PM · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 21 April 2010
…with no type recorded49
Operational controls None recorded without a removal date
Years with a record 30 calendar years (1980–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-47624

Documentation record

Registered dimensions (L × B × D)286.5 ft × 52.5 ft × 16.0 ft
Registered tonnagegross 1,929 / net 1,929
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT, INCORPORATED · JEFFERSONVILLE, IN, UNITED STATES · built 1973
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1929 - Regulatory (Subpart C or D), Gross Ton
1929 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

117 inspections, each with its date, unit and type; 85 deficiencies with the resolution recorded against each; 10 vessels inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 117

21 April 2010 Examination of Repairs · Internal Structural Exam · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3720371
2 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3544265
23 September 2008 Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331024
21 September 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3329773
11 February 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3147972
24 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3135911
1 November 2007 Internal Structural Exam · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3091327
15 October 2007 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3080640
9 April 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2629307
7 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2597726
11 May 2005 Internal Structural Exam · Examination of Repairs · Re-Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2374774
2 May 2005 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2347663
11 March 2005 MARPOL Annex I Examination · Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2308342
11 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2312647
23 August 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2174125
3 August 2004 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2157698
25 November 2003 Re-Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1966394
17 September 2002 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1678064
9 September 2002 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1673152
3 September 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1682133
28 May 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1622109
26 April 2002 Hull Examination · Internal Structural Exam · Cargo Tank Internal · COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1599509
1 June 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389389
8 May 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 643862
28 April 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365732
26 March 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 664468
12 March 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 190288
18 January 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 196654
18 January 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 463040
14 April 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 788804
15 March 1999 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 798571
6 October 1998 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 801670
31 August 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 799917
28 August 1998 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 800720
25 August 1998 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1131920
25 February 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1116214
25 February 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1125668
26 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1463351
2 October 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 775790
16 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 443798
10 September 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 155343
10 September 1997 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 785833
5 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 677268
23 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 487003
15 April 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1097476
4 April 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451166
10 March 1997 Deficiency Check · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1101687
20 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 677269
16 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 437201
16 February 1997 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1105292
15 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 188061
20 March 1996 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1078077
31 March 1995 Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1136064
21 March 1995 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135283
15 December 1994 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 833914
6 October 1994 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1354983
30 May 1994 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1327418
10 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365930
4 April 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 677261
28 March 1994 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 857754
4 March 1994 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 857628
2 March 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 57203
16 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 445962
13 July 1993 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 843752
7 April 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1147540
16 March 1993 Examination of Repairs · Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 839903
8 January 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1136726
16 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 141030
13 March 1992 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254998
19 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262060
9 February 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84809
9 February 1992 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264673
25 January 1992 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 954533
26 December 1991 Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1270520
13 December 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 674619
6 December 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 467108
25 September 1991 Deadweight Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1246018
17 May 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911101
17 May 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1220947
13 March 1991 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1243429
7 December 1990 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 925049
31 October 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1216538
2 October 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 905661
22 September 1990 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 899965
9 August 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 925417
19 July 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 536973
2 July 1990 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 918115
29 May 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1228637
2 May 1990 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 924977
29 November 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 487842
25 April 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1035176
20 April 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342466
30 March 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 483359
21 August 1988 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1345114
11 August 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1347671
14 April 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1043096
10 December 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1002340
30 July 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1308950
16 July 1987 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1327869
19 May 1987 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1028858
24 February 1987 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1009335
10 February 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 481044
24 December 1986 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1000599
30 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308624
15 April 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 483898
15 March 1986 Credit Drydock · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301623
26 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1289704
4 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978488
20 January 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 439824
21 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977414
9 September 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283181
14 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278742
12 January 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278733
3 March 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968538
3 March 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276049
20 August 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271244
25 August 1980 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968927

Deficiency record · 85

Pollution Prevention/Response › Prevention Equipment › Emergency Towing Capability
Issued 21 April 2010 Resolved
Emergency Towline wasted and unusable. Replace Towline.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 April 2010 Resolved
Hatch Covers Not properly labled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 21 April 2010 Resolved
Anchor Shackles show excessive waste. Replace shackles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 April 2010 Resolved
Anchor Stock missing on one side. Repair or replace Anchor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected.
Deck/Cargo › Mooring/Anchoring › Standard Link (anchor chain)
Issued 21 April 2010 Resolved
Pelican Hook inoperable. Show proper operation of Pelican Hook
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 21 April 2010 Resolved
Port AFT Cargo Pump inoperable. Show proper operation of Cargo Pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2010
Resolution: Corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 21 April 2010 Resolved
Flame screens not properly maintained. Replace or repair flame screens on cargo vents
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2010
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 21 April 2010 Resolved
Provide fuel storage tank vent with flame screen.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2010
Resolution: Corrected
Construction/Loadline › Structures › Scupper
Issued 21 April 2010 Resolved
Scupper plugs missing from coaming. Provide proper amount of scupper plugs
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2010
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 April 2010 Resolved
High Level and Overfill Alarms not working properly. Show proper operation of alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2010
Resolution: Corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 April 2010 Resolved
Two portable hoses tied down to main deck not properly marked and tested. Remove are provide testing for hoses.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 25 May 2010
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 April 2010 Resolved
Battery in Generator Room not properly wired. Remove, repair, or replace current wiring system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2010
Resolution: Corrected.
Documentation › Markings/Placards › Warning Signs
Issued 2 March 2009 Resolved
Post emergency shutdwon sign.
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 3 March 2009
Construction/Loadline › Hull › Hull Plating
Issued 23 September 2008 Resolved
Vessel is restricted to TT104 until a shipyard is designated to effect permanent repairs to damage listed in the narrative.
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 24 September 2008
Construction/Loadline › Hull › Hull Plating
Issued 23 September 2008 Resolved
Proceed to Bollinger Algiers from TT104 for repairs. Vessel is restricted to Bollinger Algiers until permanent repairs are made and accepted by class.
Action required: 705 - Other - as specified
Resolved 7 October 2008
Resolution: ABS surveyor witnessed air test and found the final repairs to be acceptable.
Construction/Loadline › Hull › Collision Chock
Issued 1 November 2007 Resolved
Complete repairs to collision bulkhead & make reeady for NDT. (18 x 18 insert required by ABS)
Action required: 705 - Other - as specified
Resolved 22 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 November 2007 Resolved
Complete hydrostatic testing on all cargo & vapor control system piping. Label as such w/ date & test pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 1 November 2007 Resolved
Outfit alarm panel w/ 2 distinct audible & visual alarms for high level & overfill (95 & 98%). Prove proper operation to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 22 January 2008
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 1 November 2007 Resolved
Prove proper operation of overspeed trips on generator.
Action required: 705 - Other - as specified
Resolved 22 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 1 November 2007 Resolved
Prove proper operation of port cargo pumps.
Action required: 705 - Other - as specified
Resolved 22 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 November 2007 Resolved
Prove proper operation of all navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 November 2007 Resolved
Temporary COI issued 22JAN08. Company is applying for Cargo Authority Attachment in order to carry Caustic Soda Solution (CSS).
Action required: 705 - Other - as specified
Resolved 7 July 2026
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 March 2005 Resolved
Place a copy of the CAA onboard vessel prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2005
Resolution: Received faxed copy of the CAA, company to place this onboard the vessel.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 3 August 2004 Resolved
Expired Loadline.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 11 March 2005
Resolution: Verified Load Line certificate valid and endorsed by ABS.
Documentation › Certificates/Documents › IOPP Certificate
Issued 3 August 2004 Resolved
Expired IOPP. Owner to schedule new exam.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 11 March 2005
Resolution: Conducted IOPP survey. Endorsed certificate.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 25 November 2003 Resolved
The prime mover did not properly shutdown from the emergency shutdown station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2003
Resolution: The vessel rep demonstrated a proper emergency shutdown function.
Communications › Alarms/Indicators
Issued 25 November 2003 Resolved
The audible alarm for the closed gauging system did not work. LEGACY COMPONENT DESC: Cargo high level/overfill
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2003
Resolution: Demonstrated proper audible and visual alarms.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 November 2003 Resolved
Inner surface on nav light stands were not mat black.
Action required: 705 - Other - as specified
Due 15 December 2003
Resolved 25 November 2003
Resolution: Painted inner surfaces mat black.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 25 November 2003 Resolved
The flame screen on the vent for the #3 tank had holes punched in it, and there was no flame screen on the diesel fuel tank vent. LEGACY COMPONENT DESC: Flame Screens
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2003
Resolution: Provided proper flame screens.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2003 Resolved
An electrical cable for control of the #3 Stbd deep well pump was loose on deck. LEGACY COMPONENT DESC: Tripping hazard
Due 15 December 2003
Resolved 25 November 2003
Resolution: The cable was secured in hard conduit.
Electrical › Electrical Distribution System (service)
Issued 25 November 2003 Resolved
Nonconductive flooring was not provided in front of the distribution panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Due 15 December 2003
Resolved 25 November 2003
Resolution: Nonconductive flooring was provided.
Engineering › Fuel Oil Storage/Transfer System
Issued 25 November 2003 Resolved
The sight glass on the diesel fuel tank was hard plastic and not guarded. LEGACY COMPONENT DESC: Gauge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2003
Resolution: A glass sight glass with a metal guard was installed.
Engineering › Diesel Engine (auxiliary)
Issued 13 November 2003 Resolved
The diesel engine for the vessel's generator did not shutdown when over speed. LEGACY COMPONENT DESC: Over speed Device
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2003
Resolution: A technician demonstrated satisfactory overspeed capability.
Navigation › Collision/Grounding Avoidance
Issued 13 November 2003 Resolved
There was no central nav light stand to show special flashing while inland. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2003
Resolution: A nav light stand was installed on deck.
Construction/Loadline › Hull
Issued 9 September 2002 Resolved
Make permanent repairs to the 14" horizontal fracture in the sideshell of the #1 starboard cargo tank prior to loading cargo but not later than 30 SEP 02. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 17 September 2002
Resolution: Repairs made to side shell and frame in # 1 stbd wing tank. Rcvd Class report repairs SAT
Electrical
Issued 26 April 2002 Resolved
Prove proper operation of overfill and high level alarms to the satisfaction of CG Marine Inspector. No loading is allowed of any petroleum products as defined in 33 CFR.
Condition: Placed in Improper Service
Due 26 May 2002
Resolved 29 April 2002
Resolution: Alarm system rebuilt.
Deck/Cargo
Issued 26 April 2002 Resolved
Crop and renew with appropriate size insert wasted cargo tank top on #3 stbd wing void where temp repair with pad welding is present (located just fwd of #3 deep well pump). No loading into this tank is allowed. Vsl to maintain stability loading requirements.
Condition: Unknown
Due 26 May 2002
Resolved 31 May 2002
Resolution: Inserted deck, witnessed sat vacuum box test.
Construction/Loadline
Issued 26 April 2002 Resolved
Gauge pitted areas on diesel tank and repair as appropriate.
Due 26 April 2002
Resolved 26 April 2002
Resolution: Diesel tank top and bottom renewed.
Pollution Prevention/Response
Issued 24 April 2002 Resolved
Replace all missing containment plugs.
Due 26 April 2002
Resolved 26 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 24 April 2002 Resolved
Retest fire extinguishers.
Due 26 April 2002
Resolved 26 April 2002
Construction/Loadline › Structures
Issued 3 April 2002 Resolved
Clean bilges in electrical control room; make ready for inspection. Crop and renew all wasted frame members in this space.
Condition: Unknown
Due 26 April 2002
Resolved 26 April 2002
Resolution: 17 frames were cropped and renewed.
Engineering › Diesel Engine (auxiliary)
Issued 1 April 2002 Resolved
Prove proper operation of cargo pump engine and emergency shutdown. No offloading of any cargo is allowed.
Condition: Unknown
Due 26 May 2002
Resolved 29 April 2002
Deck/Cargo
Issued 1 April 2002 Resolved
Replace/renew hatch on #2 port wing cargo tank.
Due 26 April 2002
Resolved 26 April 2002
Resolution: Hatch renewed.
Deck/Cargo
Issued 1 April 2002 Resolved
Renew cotter pins on towing chain shackles.
Due 26 April 2002
Resolved 26 April 2002
Deck/Cargo
Issued 1 April 2002 Resolved
Weld fracture in stern void, upper stbd corner, aft.
Due 26 April 2002
Resolved 26 April 2002
Deck/Cargo
Issued 1 April 2002 Resolved
Replace pipe hanger, u-bolt in #1 center cargo tank forward end.
Due 26 April 2002
Resolved 26 April 2002
Deck/Cargo
Issued 1 April 2002 Resolved
Remove epoxy film, temp repair from deck under and around deck storage container. Crop and renew wasted deck.
Condition: Unknown
Due 26 April 2002
Resolved 26 April 2002
Deck/Cargo
Issued 1 June 2001 Resolved
PRIOR TO OFFLOADING CARGO, REPLACE WASTED MUFFLER TO CARGO PUMP ENGINE.
Condition: Unknown
Due 2 June 2001
Resolved 7 June 2001
Documentation
Issued 1 June 2001 Resolved
SUBMIT LETTER TO G-MSC REQUESTING CARRIAGE OF ON-DECK CONTAINER, AND FOR CHANGES TO VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 30 September 2001
Resolved 26 April 2002
Deck/Cargo
Issued 1 June 2001 Resolved
PROVE PROPER OPERATION OF HIGH LEVEL AND OVERFILL ALARMS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VESSEL NOT TO LOAD CARGOES DEFINED AS OIL IN 33 CFR 151.05 UNTIL THIS ITEM IS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 1 July 2001
Resolved 26 April 2002
Deck/Cargo
Issued 26 January 1998 Resolved
INSTALL A VALVE OR CAP ON THE CARGO INERTING LINE._x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998 Resolved
COMPLETE THE ATTACHED WORKLIST ITEMS. SEE MINS.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Deck/Cargo
Issued 26 January 1998 Resolved
RENEW THE FLAME SCREEN ON THE FORWARD P/V VALVE ON THE VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998 Resolved
REPACK STUFFING TUBES ON OVERFILL JUNCTION BOXES AT TANK AS NEEDED.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Deck/Cargo
Issued 26 January 1998 Resolved
INSTALL B/3 VENTS ON ALL CARGO TANKS. TO BE COMPLETED AT DRYDOCK.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998 Resolved
ENCLOSE ELECTRICAL CABLES FOR BOTH FORWARD CARGO PUMPS IN A STEEL ENCLOSUREOR PIPE IN ACCORDANCE WITH 46 CFR 111.105-3 AND IEEE-45 SECTION 20.4._x001C_ TO BE COMPLETED AT DRYDOCK.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998 Resolved
MAKE THE WATERTIGHT HATCH DOGGING DEVICE FOR THE FORWARD MACHINERY SPACE OPERABLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Deck/Cargo
Issued 10 September 1997 Resolved
MAKE PERMANENT REPAIRS TO 1/4" HOLE IN THE #35 BULKHEAD PORT, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NLT 25SEP97. CARGO SHALL NOT BE CARRIED IN #4 PORT CARGO TANK UNTIL THIS REPAIR IS COMPLETE AND INSPECTED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 September 1997
Resolved 10 September 1997
Deck/Cargo
Issued 4 April 1997 Resolved
PROVE PROPER OPERATION OF THE LOSS OF LUBE OIL SHUT DOWN ON THE CARGO PUMP DIESEL GENERATOR FOR ELECTRIC DEEP WELL PUMPS.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Deck/Cargo
Issued 4 April 1997 Resolved
PROVE PROPER DOCUMENTATION FOR HYDRO TESTING CARGO PIPES AND TRANSFER HOSES.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Deck/Cargo
Issued 4 April 1997 Resolved
PROVIDE COVERS FOR ALL ROTATING MACHINERY ON CARGO DEEP WELL PUMPS.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Construction/Loadline
Issued 16 February 1997 Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL PLATE IN WAY OF #1 STBD CARGO TANK WHERE FRACTURED, APPROXIMATELY 5' 6" FROM TURN OF DECK AT FWD BULKHEAD.
Condition: Unknown
Due 16 February 1997
Resolved 16 February 1997
Construction/Loadline
Issued 4 March 1994 Resolved
Make permanent repairs to temporary repair of hole located 11 ft. from maindeck & 15 ft. from forward bulkhead in #2 port cargo tank side shell. No cargo may be loaded in #2 port cargo tank until permanent repairs are complete. Vessel may proceed to Tampa, FL to discharge cargo.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Deck/Cargo
Issued 13 March 1992 Resolved
Vessel may not carry Benzene or hydrocarbon mixtures containing Benzene until either approved restricted or closed gauging devices are installed onthe cargo tanks. Benzene cargoes will be removed from the List of Authorized Cargoes if not completed by the Compliance Date.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Construction/Loadline
Issued 9 February 1992 Resolved
AFFECT PERMANENT REPAIRS TO TO SKEGS AND SHELL PLATING IN WAY OF AFTER BALLAST TANK.
Condition: Unknown
Due 9 March 1992
Resolved 26 April 2002
Construction/Loadline
Issued 9 February 1992 Resolved
CERTIFY AFTER BALLAST TANK GAS-FREE AND MAKE AVAIALBLE FOR INTERNAL_x001C_ EXAMINATION BY USCG INSPECTOR.
Condition: Unknown
Due 9 February 1992
Resolved 9 February 1992
Deck/Cargo
Issued 13 March 1991 Resolved
OBTAIN PROPER COAST GUARD APPROVAL FOR CARGO PIPE MODIFICATION.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Construction/Loadline
Issued 9 August 1990 Resolved
REPLACE #3 DECK CARGO SKID ON PORT SIDE. NO DECK CARGO TO BE CARRIED PRIOR TO REPAIRS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Construction/Loadline
Issued 2 July 1990 Resolved
REPLACE #3 DECK CARGO SKID ON PORT SIDE.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Construction/Loadline
Issued 29 May 1990 Resolved
CROP OUT ALL VISUAL WASTAGES & DETECTED WASTAGES OVER 25% OF ORIGINAL PLATING THICKNESS AS DETERMINED BY GAGING REPORT.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 20 April 1989 Resolved
REPAIR WIRE CONNECTIONS AT PORT AND STBD RUNNING LIGHTS ACCORDING TO "GOOD MARINE PRACTICE"
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Deck/Cargo
Issued 20 April 1989 Resolved
IN ACCORDANCE WITH 46CFR35.35-70, TEST THE CARGO DISCHARGE PIPING AT THE MAWP.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Construction/Loadline
Issued 20 April 1989 Resolved
CLEAN, GAS FREE AND MAKE AVAILABLE FOR INSPECTION #1 PORT CARGO TANK TO EXAMINE SET-IN IN WAY OF SIDE SHELL PLATING.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Deck/Cargo
Issued 16 July 1987 Resolved
REPLACE WITH NEW AS ORIGINAL ALL ON DECK CARGO PIPING FOR #3 AND #4 PORT WING TANKS. #3 AND #4 PORT WING CARGO TANKS ARE NOT TO BE LOADED WITH CARGO UNTIL THIS REQUIREMENT IS CORRECTED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Deck/Cargo
Issued 16 July 1987 Resolved
REPLACE WITH NEW AS ORIGINAL 6" ULLAGE HATCH COVER AND STRONG BACK FOR #1 STARBOARD CARGO WING TANK ULLAGE STANPIPE OPENING. #1 STARBOARD CARGO WINGTANK IS NOT TO BE LOADED WITH CARGO UNTIL THIS REQUIREMENT IS CORRECTED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Electrical
Issued 3 March 1983 Resolved
FLEET CABLE HANGERS MISSING AND WASTED ON MAIN DECK.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Deck/Cargo
Issued 3 March 1983 Resolved
REPLACE CARGO PIPING SUPPORTS WHERE MISSING OR WASTED ON MAIN DECK.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Deck/Cargo
Issued 3 March 1983 Resolved
REACH ROD VALVES CORRODED AN INOPERATIVE.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Deck/Cargo
Issued 3 March 1983 Resolved
PV VENT PIPE WASTED IN WAY OF #3 PORT WING TANK.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Navigation
Issued 3 March 1983 Resolved
CENTER NAVIGATION LIGHT STAND BENT.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Electrical
Issued 3 March 1983 Resolved
EYS ELECTRICAL FITTING ON PORT AFT CARGO PUMP WASTED.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Electrical
Issued 3 March 1983 Resolved
VENT FAN MOTOR AND VENT COVER IN WAY OF AFT MACHINERY SPACE INOPERABLE AND WASTED.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Unknown
Issued 3 March 1983 Resolved
DRAFT AND LOADLINE MARKS NEED REPAINTING,
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Deck/Cargo
Issued 3 March 1983 Resolved
SUPPORT FOR WARNING SIGN WASTED.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983
Electrical
Issued 3 March 1983 Resolved
ELECTRICAL CABLE CONDUIT IN WAY OF MAIN DECK AND AFTER MACH SPACE WASTED.
Condition: Unknown
Due 3 March 1983
Resolved 3 March 1983

Casualty record · 1

21 September 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3329773
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.