Records from 1984 to 2026. Most recent: inspection, 28 July 2026.
Inspection history · 400
28 July 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8453504
14 July 2026
Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8313439
23 June 2026
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8313436
1 December 2025
Administrative Inspection · In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8275559
10 September 2025
Administrative Inspection · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8230118
30 May 2025
Re-Inspection · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8148411
26 April 2025
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8120479
3 April 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8105108
29 March 2025
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8101798
25 March 2025
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8099065
20 March 2025
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8097004
4 March 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8087919
4 November 2024
Re-Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8029219
30 September 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8011876
12 August 2024
Re-Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7979809
6 June 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7929435
31 May 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7924217
14 May 2024
MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7911515
29 April 2024
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7903297
26 March 2024
COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7885010
7 November 2023
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7818897
15 August 2023
Re-Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769174
2 July 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7729476
17 June 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7716977
16 May 2023
MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7690671
8 May 2023
Administrative Inspection · Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7684258
14 April 2023
Plan Review (Other than "T")
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7686954
20 March 2023
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7654128
16 March 2023
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7652453
31 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7586431
20 October 2022
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7581189
18 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7579509
18 October 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7580400
22 September 2022
MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7568176
7 June 2022
Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7470662
1 April 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7422623
16 March 2022
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7405736
2 March 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7404632
8 February 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7392392
13 December 2021
Re-Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7367431
9 November 2021
In-Service Inspection · Plan Review (Other than "T") · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7348275
14 September 2021
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7323548
1 July 2021
Administrative Inspection · Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7256231
2 June 2021
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7213064
14 May 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7197146
11 March 2021
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7154027
28 January 2021
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7132914
28 January 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7132926
24 November 2020
Re-Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7101473
25 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7064878
21 September 2020
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7062422
8 September 2020
Deficiency Check · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7053594
18 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7011895
1 June 2020
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6965402
2 March 2020
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6918753
19 November 2019
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6849339
21 October 2019
Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6839105
30 August 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6802360
22 August 2019
Deficiency Check · Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6791310
16 August 2019
Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6785279
5 June 2019
Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6703668
20 April 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6670349
11 March 2019
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6640408
28 February 2019
In-Service Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6633304
17 December 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6598979
26 November 2018
MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6586951
12 October 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6560108
4 September 2018
Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6532031
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505946
5 June 2018
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6434093
1 May 2018
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6403108
21 April 2018
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6394875
9 April 2018
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6389685
14 March 2018
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6371870
6 March 2018
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363766
21 February 2018
In-Service Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6360426
15 November 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6308649
8 November 2017
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6303055
30 September 2017
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6214049
14 September 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6266724
6 September 2017
MTSA Verification · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6259942
1 September 2017
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6256900
28 August 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6286908
6 June 2017
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6166702
11 May 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6143841
25 April 2017
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6132465
28 March 2017
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6104234
2 February 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6081502
29 November 2016
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6049757
22 November 2016
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6046614
8 November 2016
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6045827
17 October 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6030535
18 August 2016
Deficiency Check · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5977482
20 July 2016
Examination of Repairs · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5952227
27 June 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5921278
18 June 2016
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5915218
7 June 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5905743
30 May 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5901564
16 May 2016
MTSA Verification · DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5876486
9 November 2015
Drydock Exam · Plan Review (Other than "T") · Administrative Inspection · Inclining Experiment · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5761000
30 October 2015
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5757436
14 September 2015
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5717807
8 September 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5719959
19 August 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5222331
10 August 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5218615
18 July 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5190362
6 August 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4946442
19 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4896861
19 June 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4897260
18 June 2014
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4892902
2 June 2014
Deficiency Check · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4886808
22 May 2014
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865348
24 March 2014
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4822800
5 March 2014
COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4805878
26 June 2012
DAPI Audit · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4358204
15 June 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4344792
6 May 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4303500
3 May 2012
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4301182
3 May 2012
Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4301324
24 February 2012
Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4250480
17 January 2012
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4225689
12 January 2012
Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4239988
15 September 2011
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4146164
17 August 2011
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4126822
3 August 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4112283
18 July 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4086280
14 July 2011
Excursion Permit · Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4096821
5 July 2011
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4069223
24 February 2011
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3950873
13 January 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3926244
7 January 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3915136
21 December 2010
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3914345
18 December 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3919644
13 December 2010
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3911339
11 December 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3910919
8 December 2010
Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3906884
6 December 2010
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3905023
5 December 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3906667
28 October 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3880601
27 October 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3888637
22 October 2010
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3875293
8 September 2010
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3844885
16 March 2010
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3696128
23 February 2010
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3684408
7 January 2010
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3660113
6 January 2010
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3658879
3 January 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3660980
3 April 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3460938
16 March 2009
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3434127
12 January 2009
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3392592
31 October 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3354988
30 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3354237
10 October 2008
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3342264
26 September 2008
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3333222
20 September 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3330091
30 August 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3312817
28 August 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3315878
21 August 2008
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3304974
7 July 2008
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3260412
8 June 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3231597
25 March 2008
COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3170412
27 February 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3158759
25 February 2008
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3152995
8 January 2008
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3125887
27 September 2007
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3064898
4 September 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3050937
14 June 2007
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2960515
2 May 2007
Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920793
21 April 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920783
27 March 2007
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2894968
1 March 2007
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2887988
25 July 2006
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2723148
17 July 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2716077
28 June 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2694066
30 March 2006
COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2610210
17 March 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2604208
28 February 2006
MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2589644
5 December 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2521967
25 October 2005
Re-Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2531006
2 August 2005
Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2441640
18 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2431009
4 April 2005
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316889
4 April 2005
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2440458
8 February 2005
Re-Inspection · MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2287827
18 November 2004
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2228330
28 July 2004
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2142413
23 June 2004
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2107964
10 June 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2094831
5 April 2004
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2034520
10 February 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2004744
30 January 2004
Security Plan Review - ASP
Administrative · Commandant (CG-FAC) · Activity 2000564
3 December 2003
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1957797
19 August 2003
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1879520
29 May 2003
Damage Survey · In-Service Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1804466
7 May 2003
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1788227
25 March 2003
Underwater Inspection in lieu of Drydock
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1758901
12 February 2003
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1743747
18 November 2002
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1706795
14 August 2002
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1661348
21 May 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1619046
19 February 2002
Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1486896
22 January 2002
In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1480486
11 October 2001
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1077165
7 August 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070116
24 May 2001
COI Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068379
21 February 2001
Permit to Proceed · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1384704
6 February 2001
Inclining Experiment
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1386977
31 January 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1061134
16 August 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1433729
11 May 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 106502
11 May 2000
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817657
6 April 2000
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817121
16 February 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1468554
27 January 2000
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 814351
18 January 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 667052
6 December 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 212595
10 November 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1406599
22 October 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1042973
14 September 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1120190
2 September 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1117714
3 August 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1369299
24 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 45921
10 June 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 807586
12 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 797662
10 November 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1436150
25 August 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798486
17 August 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 800470
6 August 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 796104
4 August 1998
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1467558
25 July 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 170840
20 June 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 18573
7 May 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 790465
21 April 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434709
23 February 1998
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 788850
19 February 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1467967
12 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 79465
9 February 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1408255
21 November 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 773715
20 August 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 12549
17 July 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1116810
9 July 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1114277
8 May 1997
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1105276
17 March 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421280
22 January 1997
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469148
6 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1388190
2 December 1996
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 874817
21 November 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 870865
10 October 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 844682
19 September 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1149713
13 May 1996
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1083395
2 May 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088066
22 March 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 150260
27 February 1996
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1081336
28 November 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1183588
30 October 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1188476
24 October 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 873494
12 October 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 879869
14 September 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 872071
31 August 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 871856
18 August 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 26
13 August 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 177995
1 August 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 87217
24 July 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 187632
3 July 1995
Excursion Permit
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 880788
25 June 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 10040
18 May 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 873675
16 May 1995
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 849385
20 March 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 868438
19 January 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1180296
11 January 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1173012
8 December 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1141360
17 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 186562
9 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 8008
31 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 867008
30 September 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178993
29 September 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 26328
22 September 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 170366
12 September 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 864389
9 August 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 860696
5 August 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 869242
4 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862352
4 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 866032
18 July 1994
Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 862545
12 July 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 6222
27 June 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 963205
19 June 1994
Excursion Permit · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1327814
17 June 1994
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1382776
19 January 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1162255
6 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 847983
12 October 1993
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1147039
22 September 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 842097
17 August 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1382626
16 June 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1149956
25 May 1993
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142836
22 April 1993
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1143585
18 March 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833551
18 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 834789
18 February 1993
Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1143592
19 November 1992
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1136844
9 November 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1265073
13 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 936716
9 September 1992
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1266776
11 August 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 951301
15 May 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 952507
7 May 1992
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 948093
21 February 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1259387
2 December 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 940844
14 November 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004039
22 August 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1243541
16 July 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1252467
16 May 1991
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 905933
12 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1216375
26 March 1991
Hull Examination · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 904314
19 February 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917967
3 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 930223
28 November 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1232253
19 November 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 901163
25 October 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227156
24 September 1990
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 902731
10 September 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 915311
30 August 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1235027
21 August 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1237343
6 June 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900342
18 May 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900067
10 May 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 922175
6 March 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917608
18 January 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1243472
11 January 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928291
13 December 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 928318
30 November 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 929152
13 October 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041323
15 September 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018517
5 September 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1044866
1 September 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1212475
18 June 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1238676
18 June 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338831
25 May 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036361
25 May 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1210322
18 May 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031821
16 March 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1204797
3 March 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199442
3 February 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036388
26 January 1989
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204973
20 December 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1032752
12 December 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339375
18 November 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1342464
3 October 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888750
30 August 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1348691
18 August 1988
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1345469
21 July 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036539
20 June 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 892836
18 May 1988
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199753
26 April 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1350948
20 April 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352717
29 February 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029169
22 February 1988
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028460
22 February 1988
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1328909
16 February 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330758
7 January 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1009218
7 December 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004935
19 November 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1333554
16 November 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332227
6 November 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1321216
6 November 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329984
8 September 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1009285
26 August 1987
Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1312091
13 July 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017553
29 May 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031676
20 March 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329505
27 February 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005572
2 December 1986
Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330687
10 November 1986
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1016864
14 October 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017289
8 October 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1008414
3 October 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1006414
22 September 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325066
16 September 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1322878
3 September 1986
Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030822
6 August 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1304921
18 July 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017405
9 June 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991486
30 May 1986
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296131
21 February 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296734
24 January 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302947
10 January 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302242
11 November 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993864
1 November 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994763
18 October 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305707
4 October 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 987432
21 September 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 987430
4 September 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296704
28 August 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295628
25 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982023
31 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286373
30 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286372
20 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1291390
26 March 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1289647
21 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 984153
31 January 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1290150
7 December 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1284745
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 July 2026
Resolved
All doors shall be capable of operation from either side by 1 person. The handicap buttons on both port/starboard salon doors are not functional. Provide operational evidence of handicap buttons prior to September 1, 2026.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2026
Resolved 3 August 2026
Resolution: Repaired doors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 July 2026
Resolved
The failsafe state must be evaluated for each subsystem, system, or vessel to determine the least critical consequence. There is no opolicy indicating if generators should be run in manual or auto and if the generators should be set to air or electric start first. Create policy for how generators should be run while underway prior to August 1, 2026.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2026
Resolved 3 August 2026
Resolution: Policy created
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 July 2026
Resolved
All alarms must be provided with a means to test audible and visual annuciatiors. Engine Room Control alarm test is only shwoing visual and not sounding audible alarm. Provide means to test audible alarm prior to September 1, 2026.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2026
Resolved 3 August 2026
Resolution: Replaced circuit board
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 23 June 2026
Resolved
The respective piping systems installed on ships and barges must have the necessary pumps, valves, regulation valves, safety valves, relief valves, flanges, fittings, pressure gages, liquid level indicators, thermometers, etc., for safe and efficient operation of the vessel. Liquid was actively leaking into void 5. Identify cause of leak and repair to the satisfaction of the MI. 46 CFR 56.01-1(b) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2026
Resolution: ABS attended and verified leaks were repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 23 June 2026
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Port and starboard MESs are not currently onboard. Install MESs and provide servicing certificates to satisfaction of MI. 46 CFR 199.190 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2026
Resolution: MESs isntalled and servicing certs provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 June 2026
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Adapter to test generator L/O PSTP was not available. Procure adapter prior to 1AUG26. 46 CFR 61.20-3(a) 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 14 July 2026
Resolution: Received adapter
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 June 2026
Resolved
Passenger vessels exceeding 100 gross tons constructed on or after July 1, 1935, and emergency systems for all ships, must use fuel that has a flashpoint exceeding 110 °F for internal combustion engine units. Such vessels must carry a sufficient quantity of fuel to supply the emergency electrical system. Fuel transfer pump was not operational. Repair to the satisfaction of the MI prior to 1AUG26. 46 CFR 58.50-1(b) 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 3 August 2026
Resolution: Cleared e-stop
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 June 2026
Resolved
On vessels required to have a final emergency power source by § 112.05-5(a) of this chapter, the following emergency lighting and power loads must be arranged so that they can be energized from the final emergency power source: Each load under § 112.15-1. Emergency light in engine room, prior to entering the boiler space was not working. Repair to the satisfaction of the MI prior to 1AUG26. 46 CFR 112.15-5(a) 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 14 July 2026
Resolution: Light Replaced
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2026
Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Fire stations #1 and #7 were found with leaking valve packing. Repair to satisfaction of MI prior to 01AUG26. 46 CFR 76.10-15(a) 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 28 July 2026
Resolution: Fire stations no longer leaking
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 June 2026
Resolved
Doors in bulkheads required to be Class A-60, A-30, or A-15 shall be of hollow steel or equivalent metal construction solidly filled with approved structural insulation capable of meeting the requirements for a Class A-15 bulkhead. Port side crow’s nest fire door and starboard side 02 deck amidships fire doors are not self-closing. Repair to satisfaction of MI prior to 01AUG26. 46 CFR 72.05-25(b) 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 3 August 2026
Resolution: Repaired doors
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 23 June 2026
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work. Port side, aft food storage room has been converted to an emergency gear locker with associated equipment relocated into the space. Update fire control plan to satisfaction of MI prior to 01AUG26. 46 CFR 71.65-10 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 3 August 2026
Resolution: Updated FCP
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 June 2026
Resolved
Previously approved installations may be retained as long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Fixed fire fighting system in galley has been removed for years but pull station remains. Remove pull station to satisfaction of MI prior to 01AUG26. 46 CFR 76.05-20 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 3 August 2026
Resolution: Removed pull station
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2026
Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Dead end wires were found in the emergency gear locker and port side car deck overhead. Remove wires or properly terminate in junction box/equipment to satisfaction of MI prior to 01AUG26. 46 CFR 70.25-1 705c
Action required: 705 - Other - as specified
Due 1 August 2026
Resolved 28 July 2026
Resolution: Wires properly secured.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 June 2026
No resolution recorded
Electric installations and electric equipment must be inspected at the inspection for certification and periodic inspection to determine mechanical and electrical condition and performance. Emergency lighting covers on the 03 deck and starboard forward stairwell are broken. Repair/replace to satisfaction of MI prior to 01AUG26. 46 CFR 110.30-5 705c
Action required: 705 - Other - as specified
Due 1 August 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 September 2025
Resolved
Subdivision bulkheads shall be watertight. MI witness rusted through hole in bow thruster space starboard side forward overhead leading to outside. Provide repair proposal for approval from OCMI.
46 CFR 72.01-25(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 21 April 2026
Resolution: Repairs verified complete by attending DI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2025
Resolved
An electric wiring must be installed to prevent any person from accidentally contacting energized parts. MI found dead end wire that was hot. de-energize wire, tag-out breaker. Remove wire ccompletely or cap off ends. 46 CFR 111.05-3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 11 September 2025
Resolution: Recieved photo of wires stowed in junction box.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 September 2025
Resolved
On vessels required to have a final emergency power source by § 112.05-5(a) of this chapter, the following emergency lighting and power loads must be arranged so that they can be energized from the final emergency power source:
(b) The machinery, controls, and alarms for each passenger elevator.111.91-1 Power, control, and interlock circuits.
Each electric power, control, and interlock circuit of an elevator or dumbwaiter must meet ASME A17.1. Missing required illuminated signal marked Elevator Emergency Power.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 13 November 2025
Resolution: Operator installed light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 September 2025
Resolved
171.111 Penetrations and openings in watertight bulkheads in vessels of 100 gross tons or more.(a) Except as provided in paragraph (f) of this section, each opening in a watertight bulkhead must have a means to close it watertight. The four valves in the engine room's aft bulkhead leading to the steering gear flat were all found open. One of the selfclosing valves was missing its valve body cap.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 30 September 2025
Resolution: Valve was repaired
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 2 September 2025
Resolved
155.410 Pumping, piping and discharge requirements for non-oceangoing ships of 100 gross tons and above.(a) No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless:
(1) The ship has at least one pump installed to discharge oily mixtures through a fixed piping system to a reception facility;
(2) The piping system required by this section has at least one outlet that is accessible from the weather deck;
(3) Each outlet required by this section has a shore connection that is compatible with reception facilities in the ship's area of operation; and
(4) The ship has a stop valve for each outlet required by this section.
(b) Paragraph (a) of this section does not apply to a ship that has approved oily-water separating equipment for the processing of oily mixtures from bilges or fuel oil tank ballast. The OWS had been removed. No Standard Discharge Connection was fitted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 1 December 2025
Resolution: Received written exemption from CG-OES.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2025
Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a position at the door. The release mechanism shall be so designed that the door will automatically close in the event of disruption to the control system. The aft galley fire door closes when operated, but fails to seal or latch securely. 46CFR72.05-25(b)(9)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2025
Resolution: Received a video showing the latching of the door when released from the local button; sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 June 2025
Resolved
The system shall be so designed and arranged that the overhead is effectively sprayed and all portions of the deck are covered. Sprinkler heads at the ends of zones 1 and 4 (forward of the car deck) failed to discharge water when activated. 46 CFR 76.23-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2025
Resolution: Piping was cleared. Witnessed sat test.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 June 2025
Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Emergency lights were inoperable in the following locations: 1. Lido Bar (port side) 2. Port and starboard ladderwells on the 03 deck. 46 CFR 111.75-15(c)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2025
Resolution: Received photos of the emergency lights working properly; sat.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 June 2025
Resolved
All electrical appliances, including, but not limited to, cooking equipment, dishwashers, refrigerators, and refrigerated drinking water coolers, must meet ANSI/UL safety and construction standards or equivalent standards under § 110.20-1 of this chapter. Also, this equipment must be suitably installed for the location and service intended. Three separate leaks were identified on the galley water heater's piping. Mineral buildup was observed at the leak points. 46 CFR 111.77-3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2025
Resolution: Received photos to support the removal of mineral build-up; sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2025
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Identified 03 issues with 3 life rings: 1. The life ring located on the port bridge wing had a dry-rotted grab line. 2. The light fixture associated with the aft starboard car deck life ring was non-operational. 3. The retroreflective tape on the forward starboard life ring was peeling off. 46 CFR 199.190 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2025
Resolution: Received photos that they replaced grab line, replaced light fixture and replaced reflective tape; sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2025
Resolved
Each space used by passengers or crew must be fitted with lighting that provides for a safe habitable and working environment under normal conditions. Cracked overhead lights were identified in the cleaning gear locker and at the aft starboard ladderwell on the car deck. 46 CFR 111.75-15 (c)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2025
Resolution: Light covers were replaced. Lights were not in a hazardous area or area subject to damage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2025
Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. The electrical wiring in the car deck overhead (forward, portside) and under the port bridgewing lacked proper support and were hanging loose.. 46 CFR 111.01-1 (2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 10 September 2025
Resolution: Temporary wire supports were added adjacent to wasted supports. Remaining supports are planed to be renewed in November drydock.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 June 2025
Resolved
Any insulation installed for heat and comfort, refrigeration (including air conditioning), or for any other purpose, and all material incidental to its installation, shall be approved Incombustible Materials. In the trash room, an overhead drainage pipe was found wrapped in tape and lacking insulation. Make permanent repairs prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Insulation was replaced. Insulation was only thermal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 June 2025
Resolved
Doors in “B” Class bulkheads shall meet the following requirements: Door frames shall be of rigid construction, and shall provide at least a 1/2 inch doorstop at the sides and top. The door sill of the aft storeroom was heavily deteriorated/corroded. CFR 72.05-25 (c)(6)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 30 April 2026
Resolution: Door and frame replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 June 2025
Resolved
It is the intent of this subpart to provide such markings as are necessary for the guidance of the persons onboard in case of emergency…Posted CO2 Operating Instructions referenced Bow Thruster/Engine Room stop valve #14. There were three valves marked #14. One of these was marked #15 which was crossed out and handwritten #14. The C/E believed one of these was marked in error.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2025
Resolution: Fire Service Technician attended vessel and corrected labeling error.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 3 June 2025
Resolved
Cylinders used for containing hazardous ship stores that are compressed gasses must be… (4) …maintained and retested in accordance with 49 CFR 173.34. Two Emergency Escape Breathing devices were stamped with a hydrostatic test date of 2012. 46 CFR 147.60 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 17 September 2025
Resolution: Recieved doumentary evidence that new EEBD bottles were purchased, recieved and installed aboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2025
Resolved
Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be retested at least every 12 years… The Emergency Generator CO2 bottle was stamped with a hydro date of 3/12. 46 CFR 147.65
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 13 November 2025
Resolution: Operator replaced bottle
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2025
Resolved
Motor Controllers(h)(2) Contain a durable heat-resistant elementary wiring diagram of the controller fixed to the inside of its door. The diagram indicated a Heater Circuit, but the heater circuit was not noted. 46 CFR 111.70-3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2025
Resolution: Diagram was revised.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 3 June 2025
Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. The stbd side of the companionway leading to the bow thruster space had a ½” hole just above the main deck but below the watertight doors sill. 46 CFR 171.111
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2025
Resolution: Weld repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 April 2025
Resolved
Vessel self reported that during mooring operations in Cape May, New Jersey the secondary electronic bow thruster tripped breaker and became non operational. Provide proof of rectification and causal analysis to Coast Guard satisfaction.
Prior to Credit Dry Dock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Administrativey cleared. Reviewed tech report which found the system satisfactory. Owner reported satisfactory operation since the report was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. While mooring in Lewes, DE the vessel was unable to bring up RPMs on the port engine while going astern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2025
Resolved 22 April 2025
Resolution: The attending MI witnessed satisfactory operation of the main propulsion system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 March 2025
Resolved
At each annual inspection, the inspector must ensure that the following tests and inspections of fire detection and extinguishing equipment have been conducted: Fixed fire extinguishing systems must be checked as noted in table 71.25-20(a)(2)... Carbon Dioxide: Test time delays, alarms, and ventilation shutdowns with carbon dioxide, nitrogen, or other nonflammable gas as stated in the system manufacturer's instruction manual. The installed System for this vessel is Kidde Marine CO2 which specified that "the tested delay period must fall in the range minus zero percent and plus 20 percent of the factory rated value (-0%, +20%). This range is based on the guidance provided in NFPA 12:20000 Standards on Carbon Dioxide Extinguishing Systems. The bow thruster is designed with a 60-second CO2 time delay. During the inspection, the time delay malfunctioned twice, with the first attempt lasting 91 seconds and the second 81 seconds (+20%: 72 seconds). Replace the CO2 time delay to meet the manufacturer's specified requirements.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 April 2025
Resolution: Conducted the testing for the bow thruster's time delay; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025
Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of- (3) the
proper condition of flotation equipment such as lifebuoy The life ring on the O2 deck (starboard side) was found to have dry-rotted grab lines.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 15 April 2025
Resolution: Vessel replaced with new life ring; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2025
Resolved
The control system must be designed for automatic shutdown of the engine with actuation of audible and visible alarms at shutdown. Automatic shutdown must occur under the following conditions: Low lubricating oil pressure. #2 SSDG satisfactorily alarmed but failed to shutdown during loss of L/O pressure test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 15 April 2025
Resolution: conducted the loss of lube oil shutdown test for the # 2SSDG; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 March 2025
Resolved
All safety and relief valves for use on pressure vessels or piping systems must be designed to meet the protection and service requirements for which they are intended and must be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel. #4 P/V relief valve leaked air during operational testing and lifted at 252 psi, exceeding the MAWP (250 psi) of the pressure vessel.
Action required: 10 - Deficiency Rectified
Resolved 25 March 2025
Resolution: Crew replaced valve, retested all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance with NFPA 10. #28 CO2 portable fire extinguisher hose was worn and degraded.
Action required: 10 - Deficiency Rectified
Resolved 25 March 2025
Resolution: Crew replaced hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2025
Resolved
The annual inspection shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, boilers and other pressure vessels, and their appurtenances, piping, main and auxiliary machinery, electrical installations… is in satisfactory condition and fit for the service for which it is intended. Port and starboard shaft alleys underneath shaft seals had water accumulation in the bilge. Correct shaft seal leakage prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Administratively cleared following inspection. No active leakage was noted on multiple consectutive inspections.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 March 2025
Resolved
A main transverse watertight bulkhead may not have non-watertight penetrations below the bulkhead deck. ½” pinhole in bulkhead found on starboard side of ladder well entrance into forward bow thruster space. Correct prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Weld repaired sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2025
Resolved
The annual inspection shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, boilers and other pressure vessels, and their appurtenances, piping, main and auxiliary machinery, electrical installations… is in satisfactory condition and fit for the service for which it is intended. Minor hydraulic leak found on #1 steering system pump around seal, creating a small pooling. Correct prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Administratively cleared after inspection. No oil found IWO steering pump during multiple consectutive inspections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2025
Resolved
The annual inspection shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, boilers and other pressure vessels, and their appurtenances, piping, main and auxiliary machinery, electrical installations… is in satisfactory condition and fit for the service for which it is intended. Minor hydraulic leak found on forward hydraulic bow thruster DCV, creating a small pooling. Correct prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Adminsitratively cleared following inspection. Inspected system while in operation and no active leaks were observed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 March 2025
Resolved
Bulkheads or decks of the “A” Class shall be composed of steel or equivalent metal construction, suitably stiffened and made intact with the main structure of the vessel, such as shell, structural bulkheads, and decks. 03 welded over pad eyes on main vehicle deck were deteriorated and had holes deep between ½” – 1” on the aft third of along the centerline. Correct prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Administratively cleared. Deck did not have any pad eyes. This was believed to be deteriorated filler the owner used to fill unused tie downs on their own accord.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. The port side bridge wing controls were reported inoperable.
46 CFR 58.05-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2025
Resolution: Technician replaced port side bridge wing throttle with spare. Operational test proved satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 November 2024
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Crew reported overspeed on #2 Generator does not shutdown generator or alarm. Repair overspeed protection to the satisfaction of the marine inspector.46 CFR 61.20-3(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 18 December 2024
Resolution: Operator repaired overspeed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 November 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens. Screens for port/starboard nav lights are no longer matte black. Repaint screens to the satisfaction of MI. 33 CFR 84.05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2024
Resolution: Marine Inspector physically verified that the inboard screens were painted matte black.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 November 2024
Resolved
Structural I-beams on the car (main) deck were found separated from the outer bulkhead (curtain) with broken welds and signs of corrosion behind the beams. Vessel is required to determine the condition of the structural beams (UT shots) and submit a repair proposal to the satisfaction of the MI based on the findings.46 CFR 71.30-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2024
Resolved 12 February 2026
Resolution: Affected H-Beams cropped and renewed. MISLE 8283539.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 November 2024
Resolved
Bulkheads of “A” Class shall be so constructed that they would be capable of preventing the passage of smoke and flame for 1 hour. Open cable penetrations in "A" Class boundaries and multiple holes were identified on the starboard side of the bridge bulkhead. Repair “A” Class boundaries to original fire protection standards prior to COI renewal inspection. 46 CFR 72.05-10 (c)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 March 2025
Resolution: MI inspected during COI inspection; sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2024
Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. The electrical wiring in the car deck overhead (forward, amidships) lacked proper support and was hanging loose. Additionally, the drainage piping along the centerline amidships was missing insulation. Make permanent repairs prior to COI renewal inspection.
46 CFR 111.01-1 (2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 March 2025
Resolution: MI inspected during COI inspection; sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2024
Resolved
Electric installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. All emergency stops near the entrance to engine room are extremely corroded. Repair or replace to the satisfaction of the marine inspector by next inspection. 46 CFR 61.20-3(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 December 2024
Resolution: Operator replaced emergency stops. Tested emergency stops; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 November 2024
Resolved
The main steering gear and rudder stock must be—Of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. Both rotary vane rudder post seals were leaking hydraulic oil. Repair to the satisfaction of the marine inspector prior to credit drydock. 46 CFR 58.25-10(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Administratively cleared after inspection. Rudder post seals are a water barrier. Oil leaks were historicaly normal for this vessel and consistent with industrial hydraulic norms.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 4 November 2024
Resolved
An inspection of passenger and crew quarters, toilet and washing spaces, serving pantries, galleys, etc., shall be made, in general, at least once in every month. The decking in the handicapped accessible cubicle of the male toilet (main deck) was found to be uneven and deteriorated, posing safety hazards for both crew and passengers. Repair or replace to the satisfaction of the marine inspector by next inspection. 46 CFR 71.45-1 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2025
Resolution: MI inspected during COI inspection, sat
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 November 2024
Resolved
Plans and specifications required... Fire control diagram showing location and type of all required fire-screen insulation, including main fire zone and
subdivisions and enclosures. The onboard Fire Control Plan was a preliminary version and had not been approved. Additionally, there were several handwritten amendments that had not been verified by the Class or the Coast Guard. Replace with approved version of FCP. 46 CFR 71.65-5 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 November 2024
Resolved 5 November 2024
Resolution: Vessel installed the approved version prior to departure of [name withheld] verified that FCP is approved and updated.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 August 2024
Resolved
Doors shall have a latch with a minimum throw of 3/4 inch which can be operated from either side of the door.
A-60 Boundary doors to Engineering Operating Station do not remain shut. Make permanent repairs to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 30 September 2024
Resolution: Door latch was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
Materials used in the manufacture of tubing, pipes, valves, flanges, and fittings shall be selected from those specifications that appear in 46 CFR 56.60-1, Table 56.60-1(a) or 46 CFR 56.60-2, Table 56.60-2(a); or they may be selected from the material specifications of section I or section VIII of the ASME Boiler and Pressure Vessel Code. Observed Port main engine leaking air at the starter. Vessel is required to repair/replace starter or associated parts to the satisfaction of the attending marine inspector/surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel. Two (02) relief valves for air receivers (#1 & #4) failed to relieve at setpoint. Two (02) safety relief valves for air receivers (#2 & #3) did not reseat after testing. Vessel is required to replace all four (04) relief valves on each air receiver in 30 days to the satisfaction of the attending marine inspector/surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2024
Resolution: Witnesse test of relief valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Observed 2190 RPM during overspeed test of #2 generator. Generator is rated for 1800 RPM and should not exceed 2070 RPM for overspeed. Vessel is required to make repairs/adjust the governor
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2024
Resolution: Overspeed Switch was renewed, replaced and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 May 2024
Resolved
Except as otherwise provided for in this section, these requirements are applicable to the following fluid power and control systems: (1) Steering apparatus, main and auxiliary, including bow thruster systems. Port and starboard electric bow thrusters are wired in reverse order; To service to ensure operational readiness.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2024
Resolution: Witness proper operation of electric bow thruster.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2024
Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Expired medicine identified in the first-aid kit located on the bridge; To replace expired contents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 March 2024
Resolved
In addition to the emergency power sources required under part 112 of this chapter, each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. The no. 1 generator failed the operational test. Repair and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Witnessed proper operation of SSDG underload, and overspeed trip.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2024
Resolved
Fluid power motors and pumps installed on vessels subject to inspection shall be certified by the manufacturer as suitable for the intended use. Such suitability shall be demonstrated by operational tests conducted aboard the vessel which shall be witnessed by a marine inspector. Aft air compressor failed operational test. Repair and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Witnessed proper operation of aft compressor
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 26 March 2024
Resolved
Within 12 months of each subsequent servicing, except when servicing is delayed until the next scheduled inspection of the vessel, provided the delay does not exceed 5 months. Port side MES last serviced 17MAR2023. Conduct required servicing/place serviced equipment onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 19 April 2024
Resolution: Verified new, servied MES was installed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 26 March 2024
Resolved
The proper condition and operation of the survival craft and rescue boat launching appliances at loads ranging from light load to full load, except that any portion of the load test conducted in connection with replacement or end-for-ending of a fall since the vessel's last inspection or reinspection, need not be repeated. STBD side aft davit sheave seized several times throughout the rescue boat recovery. Repair davit to satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 10 April 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 March 2024
Resolved
The frequency of the tests and inspections required by this section must be: for vessels, annually or as part of the biennial and mid-period inspections. Fuel piping hydrostatic test is due (last completed 27MAR2023). Conduct test to satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 10 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 March 2024
Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a position at the door. Port, aft fire door for main salon failed to close upon activation of door release. Additionally, fire door between galley and food stores is missing self-closing mechanism. Repair fire doors to satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 19 April 2024
Resolution: Verified closing devices were repaired/installed in required locations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2024
Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system. The No. 1 & No. 3 relief valve setting on the air receivers exceeded the MAWP of 250 psi.
Action required: 10 - Deficiency Rectified
Resolved 26 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 November 2023
Resolved
Tests of the lifesaving equipment shall be carried out during each re-inspection and shall include a demonstration of the proper condition and operation of rescue boats. The aft fall wire sheave of the port rescue boat did not rotate during launch witnessed during inspection. Make operational prior to carrying passengers. 46 CFR 1999.45(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Crew removed aft sheave and discovered excessive grit build up. Crew cleaned sheave, regreased with an approved lubricant, and reassembled. Davit tested satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 2 July 2023
Resolved
Each vessel must have the following: Gyrocompass. Vessel reported gyrocompass power failure. Vessel must comply with the following restrictions until a technician's report has been reviewed and accepted by a CG marine inspector:
(1)Transit must be made with visibility of two nautical miles or greater.
(2)Daylight hour transit only.
Action required: 705 - Other - as specified
Resolved 4 July 2023
Resolution: Received tech report attesting to proper operation of gyrocompass.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 17 June 2023
Resolved
Each vessel must have the following: Gyrocompass
Vessel reported a gyrocompass that has a 15 degree error/offset.
Vessel must comply to the following restrictions until the tech report has been review by a CG marine inspector.
? The inoperable equipment shall be blanked out to prevent inadvertent use.
? Vessel must have an operable magnetic compass & current deviation table. Vessel shall
not steer using auto pilot with gyrocompass inputs.
? Vessel transit must be made with visibility of two nautical miles (NM) or greater, in
addition to favorable visibility reports over the intended route. If visibility decreases below
two nautical miles, vessel shall anchor at first available safe anchorage and contact this
office.
? Daylight hour transit only.
? Repair of inoperable equipment and a copy of the Technician or Certificating Authority report attesting to proper operation must be accepted by CG
33 CFR 164.35(d)
705 C
Action required: 705 - Other - as specified
Due 17 June 2023
Resolved 22 June 2023
Resolution: Received tech report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2023
Resolved
Containers and other similar stowage locations for lifesaving equipment must be marked correctly. 08 life jacket stowage boxes had incorrect donning of life jacket placards. Provide correct donning placards. 46CFR199.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Recieved email with pictures and documentation of new placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Each lifebuoy must be marked in block captial letters with name of the vessel and name of the port. Both forward port and stbd life buoys on boat deck need to be restenciled. 46 CFR 199.70(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Received photos of new stencil of buoys.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 May 2023
Resolved
All watertight doors shall be operated locally by manual power and are in operable condition. Stbd side aft fire door on O2 deck does not close completely. Adjust door to close completely
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Recieved email that door was adjusted and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2023
Resolved
Electrical Insulation on vessels must ensure protection from passengers and crew from electrical hazards. Galley air handler room cover was missing from electrical box allowing exposed wires. Provide cover for electrical box. 46 CFR 111.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Recieved pictures of electrical box covered
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2023
Resolved
NO1 Air Receiver relief valve lifted at 260 PSI exceeding MAWP. Replace relief valve on No1 air receiver.
46 CFR 77.03-1
46 CFR 54.15-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Replaced relief valve.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 May 2023
Resolved
Portable Extinguisher #24 on aft ladder well leaving engine room did not have annual service. Service or replace with serviced extinguisher of the same rating. 46 CFR 71.25-20(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Recieved document of relief valve was replaced and tested
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 May 2023
Resolved
During inspection found hydraulic oil on steering pedestal. Clean and remove accumulated hydraulic oil. 46 CFR 71.25-45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Recieved documetation of grease removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2023
Resolved
Drain plug found missing from M/E Raycor Fuel filters. Install plug to filter drain. 46 CFR 77.03-1
45 CFR 56.50-60(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Drain plug replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2023
Resolved
Heat tape electrical boxes found not properly secured on aft car deck. Properly mount electrical boxes. 46 CFR 77.05-1(a)
46 CFR 111.81-1(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Heat taped replaced and secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2023
Resolved
Port and stbd shaft well bilge pumps found not properly mounted. Properly mount or remove pumps. 46 CFR 71.30-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 26 May 2023
Resolution: Pumps mounted corrrectly.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 March 2023
Resolved
Means shall be provided for closing all openings to the space protected from outside such space... The construction shall be such that openings in the upper portion of the space can be closed off... by permanently installed means. STBD stack of upper louver was inoperable.
46 CFR 76.15-35(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Recieved clear video of louver operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 30 March 2023
Resolved
Each marine evacuation system must be capable of deploying as designed. Associated life-rafts to port and starboard MES were not rigged properly.
46 CFR 70.28-1
46 CFR 199.145(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Recieved report from Marine Safety Corp attesting to the proper stowage of both MESs.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 March 2023
Resolved
All lifesaving appliances and arrangements must be in accordance with Sub-chapter W. Life-saving equipment placarding was absent or painted over throughout vessel.
46 CFR 70.28-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Recieved pictures showing proper placarding
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 March 2023
Resolved
All lifesaving appliances and arrangements on passenger vessels must be in accordance with Sub-chapter W. Each side of each rescue boat bow must be marked
with - the name of the vessel. Starboard side rescue boat name was stenciled incorrectly.
46 CFR 70.28-1
46 CFR 199.176(a)(1)(i)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Recieved confirmation that stbd rescue boat has been restenciled with proper name.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 March 2023
Resolved
The installation of all electrical systems shall be in accordance with the requirements of Sub-chapter J. Each general emergency alarm signal must have an electrically operated bell. 02 general alarm signals located on the 03 deck aft of the pilothouse were inoperable.
46 CFR 77.05-1(a)
46 CFR 113.25-12(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 6 April 2023
Resolution: Both general alarm bells have been repaired and tested
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 March 2023
Resolved
The installation of all electrical systems shall be in accordance with the requirements of Sub-chapter J. 02 emergency lights on the 03 port-side aft stairwell were inoperable.
46 CFR 77.05-1 (a)
46 CFR 112.43-7(a)(4)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 6 April 2023
Resolution: E-lights were repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2023
Resolved
Each vessel must carry a life-jacket for each person on board. Vessel was missing 26 life jackets. Vessel is restricted to 851 passengers until 26 life-jackets are on board and marked IAW Sub-chapter W.
46 CFR 70.28-1
46 CFR 199.70(b)(1)/(3)
Action required: 705 - Other - as specified
Resolved 6 April 2023
Resolution: 26 lifejackets were replaced, marked, and stowed properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2022
Resolved
All items on the following worklist from DD/ISE will be complete and or addressed with local OCMI prior to COI inspection and the carrying of passengers. The current COI expired 16 march 2023.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2023
Resolution: Most of the items listed have been rectified aside from the items requiring plan review. The OCMI has awareness of these items and will be managed in a separate plan review activity.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 7 June 2022
Resolved
The electric installation of each electric power-operated winch must meet requirements of this subpart. Vessel was unable to recover port side rescue boat due to loss of power to the motor controller.
Code 705: Prior to commercial operations
Action required: 705 - Other - as specified
Resolved 9 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 June 2022
Resolved
machinery must meet applicable standards. Vessel's #1 generator's low lube oil shutdown was inoperable.
Code 705: Prior to commercial operations
Action required: 705 - Other - as specified
Resolved 9 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
Electric installations on vessels must ensure protection of passengers, crew, and the vessel from electrical hazards. Dead end wire identified under the helm at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
Electric installations on vessels must ensure protection of passengers, crew, and the vessel from electrical hazards. Identified ground on 440v panel located in the 2nd deck crew area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
Electric installations on vessels must ensure protection of passengers, crew, and the vessel from electrical hazards. Exterior outlet located on the 2nd deck, port side is missing a cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2022
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the port. Markings on the the lifebuoy located on the 3rd deck, stbd side has faded and no longer legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022
Resolved
Fire main valve located on the 3rd deck, stbd side and the fire main valve on the 2nd deck, stbd side were leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 March 2022
Resolved
Navigation light within the portable assembly was deemed inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2022
Resolved
Wooden planks were identified within the fiddly in the stack space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 1 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2022
Resolved
Each life jacket must be approved IAW 160.155, 160.176, 160.177. Identified 16 life jackets of not the approved type and 02 life jackets no longer serviceable.
Action required: 705 - Other - as specified
Due 18 March 2022
Resolved 16 March 2022
Resolution: vessel provided new type 1 pfds prior to CG departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 February 2022
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. Vessel reported that while conducting main engine start-ups, one of the vessel's start air compressors was inoperable. Vessel is permitted to operate for the remainder of today (08FEB2022) and be taken OOS at the conclusion its required routes. Vessel must provide a casual analysis and complete proper repairs.
Action required: 705 - Other - as specified
Resolved 11 February 2022
Resolution: Received class/ABS report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 December 2021
Resolved
Port side salon door did not close when the bridge pressed the closure button. Repair closure device so door closes when that bridge button is activated.
46 CFR 72.05-25(b)(9)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 21 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 December 2021
Resolved
Fan room #1 below the wheelhouse is missing structural fire protection insulation. Replace insulation that was removed.
46 CFR 72.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 22 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 September 2021
Resolved
Generator (1) had build up of grease and soot on the insulation. Ensure machinery is maintained to minimize fire hazards.
46 CFR 72.03-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 14 September 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2021
Resolved
The fan room by the 03 deck lido bar is missing insulation near the vent. Replace insulation with approved material.
46 CFR 72.05-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2021
Resolved 21 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 September 2021
Resolved
Port fire door in crow’s nest was found to be not fully self-closing. Make adjustments and prove proper operation of the port crow's nest door. 46 CFR 72.05-25(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 15 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2021
Resolved
During the inspection, 03 fire doors were found to be not fully self-closing. Make adjustments and prove proper operation of the starboard crow's nest door, port forward passenger salon door, and starboard aft passenger salon door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2021
Resolution: Received deficiency rectification report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 June 2021
Resolved
#2 generator loss of lube oil alarm and shut down were not operative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2021
Resolution: Failure caused by loose nut that caused solenoid failure. Failed solenoid replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 March 2021
Resolved
Salon deck stbd midship door and port and stbd Crows Nest Lounge doors do not fully close. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Received def recs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021
Resolved
Dead end wire identified in the aft section of the pilothouse. Remove wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Received def recs.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 March 2021
Resolved
Overhead vent cover in the galley is missing. Replace cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2021
Resolution: Received def recs.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 11 March 2021
Resolved
Steel vertical pipe penetrating the middle of the galley has a temporary repair in place. Make permanent repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2021
Resolution: Received def recs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2021
Resolved
Troubleshoot and make repairs to #2 generator. Vessel is restricted from carrying passengers until
satisfactory repairs are made and verified in the presence of attending marine inspector or ABS surveyor and class report received by local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2021
Resolution: Received report from ABS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 November 2020
Resolved
All bulkheads or decks of the "A" class shall be composed of steel or equivalent metal construction. The fan room on deck 3, classified as an A class boundary, has an opening on the starboard side bulkhead which does not have a proper A class closure. This is currently an opening in bulkhead with no means to maintain A Class fire boundary. Make repairs to meet current fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2021
Resolved 14 May 2021
Resolution: Installed damper cover and louvers
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 November 2020
Resolved
Crows nest lounge starboard door has cracked glass in the window. Make repairs and prove structural fire protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2020
Resolved
Piping systems shall be completed to conform to requirements of the regulations and engineering design. Fuel sensing line on the port main engine was observed to be experiencing excessive vibration. Install hanger or other means to secure piping and prevent damage from vibration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 12 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 November 2020
Resolved
Vessel is required to have lights in the machinery space with a temporary emergency power source to allow essential operations. Battle lantern in aft section of engine room is not operational and requires repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 12 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 November 2020
Resolved
All portable fire extinguishers shall be maintained in accordance with NFPA 10. Two extinguishers in the bowthruster space have not been serviced since 2019. Provide proof of servicing, have these extinguishers serviced, or replaced in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 12 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 November 2020
Resolved
Piping systems shall be completed to conform to requirements of the regulations and engineering design. Aft generator exhaust system insulation was blackened from a suspected exhaust leak. Investigate source of exhaust leak and make repairs accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 12 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 September 2020
Resolved
Salon deck aft doors (02) and Crows Nest Lounge port and starboard doors do not fully close. Make repairs and prove proper operation. 46 CFR 72.05-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 24 November 2020
Resolution: Verified closure.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 September 2020
Resolved
No fire stop within 03 electrical cable deck penetrations: 02 under port bridge equipment console and 01 next to bridge radar station. Make repairs and prove structural fire protection. 46 CFR 72.05-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 28 September 2020
Resolution: Accepted company report, pictures, and phone conversation: Proper fire stop installed in penetrations.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 September 2020
Resolved
Crows Nest Lounge stbd door has a cracked glass. Make repairs and prove structural fire protection. 46 CFR 72.05-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 24 November 2020
Resolution: Renewed glass cracked. Issued additional def.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 July 2020
Resolved
Vessel has 06 inop general alarms, 03 on the vehicle deck and 03 on #3 deck. Repair and show proper operation in presence of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2020
Resolution: Witnessed operation of general alarms.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2020
Resolved
The CO2 system for the diesel driven bow thruster did not properly function. Make repairs and prove satisfactory test prior to operating the diesel driven bow thruster.
Action required: 705 - Other - as specified
Resolved 24 March 2020
Resolution: Virtual CO2 testing conducted to the satisfaction of the viewing MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2020
Resolved
The CO2 system time delays failed for both the engine room and bow thruster rooms. Make proper repairs and prove satisfactory testing of the CO2 room prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Engine room CO2 system tested to the satisfaction of marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2020
Resolved
180 adult lifejackets and 6 children lifejackets were taken out of service due to unsatisfactory condition. The ferry is limited to 697 adult passengers and 82 children passengers until new and approved life jackets are supplied in their proper containers.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: Verified new lifejackets placed on vessel with proper markings.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 March 2020
Resolved
Centerline door to the crow's nest area is broken. Repair door to maintain proper fire boundary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 March 2020
Resolution: Verified proper operation of the door.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 November 2019
Resolved
Identified 03 holes on port side bulkhead of galley (class A fire boundary). Make repairs to the bulkhead to ensure a Class A fire boundary per ship's fire control plan. 46 CFR 92.05-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Repairs were made to the bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2019
Resolved
Identified aft centerline door for crow's nest lounge does not properly latch. Adjust door so it latches when self closing. 46 CFR 72.05-25(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 28 January 2020
Resolution: New hinge installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2019
Resolved
Identified forward port door for main salon deck does not latch properly. Adjust door so it latches when self-closing. 46 CFR 72.05-25(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: The self-closing device was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 19 November 2019
Resolved
Two forward emergency lights on main salon deck, by the ladderwells are inoperative. Repair or replace emergency lights. 46 CFR 111.75-15(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Repairs were made to the light fixtures.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 November 2019
Resolved
Identified hole on aft bulkhead of the Lido Bar. Make repair to the bulkhead to ensure a Class A fire boundary per ship's fire control plan. 46 CFR 92.05-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: The hole was filled to meet class A boundary classification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2019
Resolved
Remove dead end wires identified below the operation station. 46 CFR 111.60-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Wires were removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 November 2019
Resolved
Make proper repairs to holed fuel tank vent pipe on stbd side car deck. 46 CFR 56.50-85(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: A new vent pipe was fitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 November 2019
Resolved
The rail that houses the pyrometer cabling has become
dislocated from the starboard main engine and is loose
on the port main engine. Secure the rail as
intended. 46 CFR 58.05-1 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 18 December 2019
Resolution: The wires are rail were secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 November 2019
Resolved
#1 SSDG L/O low pressure shutdown was not functioning due to failed solenoid. Repaired completed and rectified prior to end of inspection.
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
Resolution: Failed solenoid on flapper was replaced prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 August 2019
Resolved
03 fire doors in the upper passenger area did not close and latch properly. Make adjustments and repairs and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 August 2019
Resolved
03 fire doors in the main passenger area did not close and latch properly. Make adjustments and repairs and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 August 2019
Resolved
Rescue boats did not have appropriate vessel name markings. Properly mark the boats and prove to the satisfaction of an attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 August 2019
Resolved
Fire extinguisher brackets #19, 20, and 25 located on the car deck were wasted. Renew brackets and prove to the satisfaction of an attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2019
Resolved
Lagging on overhead pipe on car deck was damaged and removed. Replace/renew and prove to the satisfaction of an attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 June 2019
Resolved
Public address system did not function. Make repairs and prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2019
Resolution: Technician reported the system is working.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 June 2019
Resolved
03 doors entering the salon on the 03 deck did not latch properly when closing. Make repairs and prove operation to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 June 2019
Resolved
The starboard aft door entering the salon on the 02 deck did not latch properly when closing. Make repairs and prove operation to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
Re-stencil life ring buoy on the port side of the 03 deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 June 2019
Resolved
Repair cracked window on the aft bridge door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
Replace expired water light battery on the aft part of the vehicle deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2019
Resolved
Ensure child-sized PFD’s are stowed separately from
adult PFD's and appropriately mark the stowage of them.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2019
Resolved
The bow thruster battery charger 120v connection was found chaffed and needs to be hard wired into the electrical system. The electrical cables from the start batteries to the starter need to be proven to be of adequate size and type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2019
Resolved
The elevator was unable to operate. The vessel must prove proper operation of the elevator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: Elevator returned to service.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2019
Resolved
The heaving line on the port stern can not be hung on electrical wiring. The heaving line shall be removed or relocated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2019
Resolved
Submit a repair proposal to make repairs or renew 03 watertight doors on the main deck. Both access doors to the engine room and bow thruster space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 5 April 2019
Resolution: Vessel performed maintenance on 3 WTD's, replaced the gaskets, and performed a chalk test to ensure they closed properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2019
Resolved
Submit a repair proposal to make permanent repairs to the port steering shaft packing gland.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 5 April 2019
Resolution: Dorchester Shipyard installed additional retainers for the port side packing gland on the steering shaft stopping the leak. Plan on reworking the rudder posts, packing, and gland during the next dry dock in February 2021.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 March 2019
Resolved
Replace missing insulation in engine room bulkhead around #1 air receiver and #2 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 5 April 2019
Resolution: Replaced missing insulation in e/r.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2019
Resolved
Prove proper operation of 02 fire doors located on the 02 level and crow's nest.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 5 April 2019
Resolution: Adjusted doors to close properly.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 November 2018
Resolved
Replace all missing fire protection insulation in eng room overhead. 46 CFR 72.05-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2018
Resolved 13 December 2018
Resolution: Vessel replaced all missing fire protection insulation in engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 November 2018
Resolved
Properly re-install the eng room overhead soft patch to make it water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2018
Resolution: Received pictures of the overhead installation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 November 2018
Resolved
Vessel has electrical panels that are not properly marked as per regulations. the directories must be updated to approved electrical drawings and have correct information including the EDG. circuit protected, amp of breaker. 46 CFR 111.40-11, 46 CFR 111.30-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2018
Resolved 28 February 2019
Resolution: Engineers properly labeled all electrical panels throughout the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 November 2018
Resolved
Vessel must properly conduct regular monthly portable fire extinguisher checks and document on fire extinguisher cards. 46 CFR 76.50
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 December 2018
Resolution: Vessel emailed paperwork showing that they check every fire extinguisher onboard monthly and log it.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 November 2018
Resolved
Submit plan review documents for newly installed bridge equipment including Radar, GPS, Garmin, FLIR, Navigation Lights, and Navigation light panel IAW 46 CFR 71.55-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2018
Resolved 11 April 2019
Resolution: Received plan review documents. Vessel POC will be forwarding the documents to MSC for review.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2018
Resolved
Fire screen door 1 has holes in it from previous bolt installation. Seal and repair door to meet class A-60 Equivalent IAW 46 CFR 72.05-25(b)(1).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 December 2018
Resolution: Vessel submitted pictures and a spec sheet showing that they filled the fire door with 3M Fire Barrier Sealant and then put steel bolts through the door to seal it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2018
Resolved
During transit, engineer identified auxiliary generator temperature was overheating. Provide causal factors and actions taken to rectify issue.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 15 October 2018
Resolution: Received and accepted signed statement attesting to repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No IMO #, NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 28 February 2019
Resolution: Vessel corrected AIS information.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 April 2018
Resolved
AF01: Repair 10cm (s-band) radar prior to sailing on 12Apr18. Send tech report/email to the email below attesting to the proper repair and operation of 10cm radar.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2018
Resolved 11 April 2018
Resolution: Port Captain sent tech report from Sperry Marine attesting to the proper repair and operation of the 10cm radar.
Engineering › Diesel Engine (auxiliary) › Block
Issued 6 March 2018
Resolved
Clean and inspect both ships service generators to include rotors, stators, exciters and megging. Provide a condition assessment report with recommended long term maintenance; for example, timeframe for deep cleaning and dipping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 30 April 2018
Resolution: Both generators were cleaned, inspected with satisfactory resistance and capacitance readings completed by Bay Diesel. Air Gap readings were also taken. (Reports included in vessel docs).
Engineering › Thrusters › Seal
Issued 6 March 2018
Resolved
Repair/replace leaking wave tank for the Omni-thruster exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 18 April 2018
Resolution: Received email documentation & pictures from the Asst Port Captain containing repair details to the Wave Suction tank in Omni-Thruster room. A new tank was built in-house using 1/4" steel plate. The tank has been installed and fully insulated.
Engineering › Bilge Water Management System › Pump
Issued 6 March 2018
Resolved
Repair/replace butterfly suction valve for the electric bilge pump. Valve is difficult to operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 14 March 2018
Resolution: Engineers removed the valve, serviced it, and reinstalled. Witnessed proper operation of the valve.
Engineering › Bilge Water Management System › Piping
Issued 6 September 2017
Resolved
Make permanent repairs to holed/corroded 1 1/2" close nipple in the bilge discharge piping in way of the bilge pump recirculation line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 14 September 2017
Resolution: Recieved email from the Port Engineer documenting repairs; piping was replaced and a new valve was installed.
Engineering › Bilge Water Management System › Piping
Issued 6 September 2017
Resolved
Bilge suction piping for aft peak tank in way of the manifold is holed. Verify the integrity of all bilge suction piping & manifolds located below the chiller units in the engine room & make permanent repairs as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2017
Resolved 13 October 2017
Resolution: Manifold and piping were thickness gauged with no areas of concern noted. Repairs were carried out in way of the the leaking pipe usng proper materials and quailfied welders.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 June 2017
Resolved
Emergency Diesel Generator failed to take load after CO2 shutdown test was completed. EDG restarts were attempted but it could not automatically take the load. EDG must automatically take load.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2017
Resolution: Chief Engineer & shore side electricians troubleshoot e-panel, found blown 5 amp fuse, replaced. Proved proper operation.
Engineering › Pressure Vessel › Pressure Gauge
Issued 6 June 2017
Resolved
#2 Air receiver safety valve relieved 10 psi over the tank MAWP. Prove proper operation of safety valve at 250 psi.
Action required: 705 - Other - as specified
Due 13 June 2017
Resolved 6 June 2017
Resolution: Chief engineer & shore side techs replaced safety valve, valve relieved over 250 psi. Replaced pressure gauge & retested, safety valve relieved at 250 psi. Gauge was out of cal. All sat.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 8 November 2016
Resolved
Remove connected surge protectors and prove adequate electrical installation in food court area.
Due 8 December 2016
Resolved 14 March 2017
Resolution: Surge protectors removed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 November 2016
Resolved
Repair or replace self-closing fire door on 02 deck aft starboard.
Due 8 December 2016
Resolved 5 January 2018
Resolution: Replaced door in kind
Fire Fighting › Firemans Outfit › Boots
Issued 8 November 2016
Resolved
Provide proper sized fireman boots for crew members.
Due 8 December 2016
Resolved 14 March 2017
Resolution: Proper sized boots were provided for crew members.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 August 2016
Resolved
Separate child lifejackets from adult lifejackets
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: Separated child lifejackets from adult lifejackets
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 August 2016
Resolved
Provide auto closure on aft galley door.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 14 September 2016
Resolution: Provided auto closure on aft galley door.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 August 2016
Resolved
Remove holdback hoods from all galley fire doors
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 14 September 2016
Resolution: Removed holdback hoods from all galley fire doors
Engineering › Pressure Vessel › Relief Valve
Issued 18 August 2016
Resolved
#2 Air receiver safety relief vlave failed to re-seat fully. Repair/replace valve and prove proper ops to CGMI.
Due 18 September 2016
Resolved 14 September 2016
Resolution: op test sat.
Engineering › Pressure Vessel › Piping
Issued 18 August 2016
Resolved
#2 air receiver inlet vlave leaks by. Repair/replace valve, prove proper operation to CGMI.
Due 18 September 2016
Resolved 14 September 2016
Resolution: Valve had no leak by, the air receivers were cross connected at the outlet valves, which made it appear the inlet valve leaked by.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 18 August 2016
Resolved
Bow thruster room watertight door does not stay dogged down when bow thruster forced ventilation is on. Adjust/repair door. Prove proper operations to CGMI.
Due 18 September 2016
Resolved 14 September 2016
Resolution: door adjusted.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 18 June 2016
Resolved
Complete causal analysis on shutdown of port engine while in Lewes, DE. Submit findings to Sector Delaware Bay prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 30 May 2016
Resolved
Vessel suffered propulsion casualty due to a low low l/o pressure on PORT MDE reduction gear. Vessel is to investigate cause and effect repair. Vessel to conduct PSTP in presence of USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2016
Resolution: Installed new alarm set points as per manufacturer recommendation. PSTSP conducted with SAT reults.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 16 May 2016
Resolved
Provide updated pilot card/vessel maneuvering characteristics for vessel following engine repower IAW 33CFR164.35.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 20 May 2016
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 May 2016
Resolved
Provide valid compass deviation card for vessel's compass IAW 46CR77.11.
Due 30 May 2016
Resolved 8 November 2016
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 May 2016
Resolved
Remove hold back hooks on forward self closing fire doors in salon IAW 46CFR72.05-25.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 20 May 2016
Documentation › Certificates/Documents › Stability Letter
Issued 16 May 2016
Resolved
Provide approved/valid stability letter IAW 46CFR78.12-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 20 May 2016
Fire Fighting › Structural - A Class Divisions › Cargo Spaces (moderate fire risk)
Issued 16 May 2016
Resolved
Vessel must reinstall missing structural fire protection insulation in Engine Room overhead STBD side outboard #2SSDG, PORT side at side shell and overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 20 May 2016
Resolution: Insulation installed. SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2016
Resolved
Vessel must remove dead end wiring to old PORT and STBD MDE prelubrication pumps.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 20 May 2016
Resolution: Wiring removed. SAT.
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 16 May 2016
Resolved
Prove proper operation of PORT MDE reduction gear Low Lube Oil Alarm.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 20 May 2016
Resolution: Verified alarm using DVT/PSTP. Alarm point 12 psi. SAT.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 September 2015
Resolved
Adjust self closing doors as listed on revised FCP. Will not close and latch.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 16 May 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 September 2015
Resolved
Life jacket location labeling in stbd game room, label with location and number of life jackets.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 16 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2015
Resolved
Found 2 life ring lights with expired batteries. Replace batteries and cerify all light batteries.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 16 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 8 September 2015
Resolved
Found one wasted life ring. Replace as new.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 8 September 2015
Resolution: Corrected on the spot. Replaced life ring.
Construction/Loadline › Penetrations › Gasket
Issued 8 September 2015
Resolved
Watertight hatches to steering gear flat found leaking. Repair or replace as new.
Action required: 705 - Other - as specified
Due 29 November 2016
Resolved 16 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 June 2014
Resolved
Provide stbd main engine failure cause analysis.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Resolution: Cause analysis provide by [name withheld], port engineer.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 19 June 2014
Resolved
Prove proper operation of stbd main engine to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Resolution: Vessel crew replaced several air control valves. Tested main engine while shifting berths, all sat.
Engineering › Steering Gear System › Cable
Issued 2 June 2014
Resolved
Port steering sending unit has the outer sheathing damage so inner wire is exposed, must replace in kind.
Due 16 June 2014
Resolved 16 June 2014
Resolution: Replaced port steering sending unit cable. All sat
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 June 2014
Resolved
The water tight door to the bow thruster & aft engine room gasket is dry rotted and no longer serviceable, must replace in kind.
Due 16 June 2014
Resolved 16 June 2014
Resolution: The water tight door to the bow thruster & aft engine room gaskets have been replaced and chalk tested. All sat
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 2 June 2014
Resolved
Repair/replace one bolt that is missing on each of the four inspection covers for the vertical drives on the MDE.
Due 16 June 2014
Resolved 16 June 2014
Resolution: Repaired bolts that were missing on each of the four inspection covers for the vertical drives on the MDE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 March 2014
Resolved
The bow thruster CO2 time delay is not operating correctly and taking 2 minutes plus to release. Fire suppression technician does not feel comfortable that the delay will operate as designed. Vessel must adjust or replace, bench test and provide written report from the technician.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2014
Resolution: Vessel provided technician report from Harris [name withheld] attesting to successful bench test of time delay valve.
Engineering › Compressed Air System (control) › Valve
Issued 5 March 2014
Resolved
The #3 & #4 air receiver relief valves are not re-seating after relief. Vessel must repair or replace these valves and prove proper operation.
Action required: 705 - Other - as specified
Due 12 March 2014
Resolved 2 June 2014
Engineering › Steering Gear System › Rudder Bearing
Issued 8 May 2012
Resolved
Received notification from Port Engineer [name withheld] that during pre-departure steering gear tests the engineer making rounds noticed that the rudder bearing on the steering gear system was moving along with the rudder commands. Make repairs to rudder bearing prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2012
Resolution: Attended vessel at ferry facility in Cape May, NJ. Inspected repairs made to rudder, to include the replacement of the seizing wire on the port side rudder stock and tightening of the loosened bolts. All sat. Inspection complete.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Liner
Issued 3 May 2012
Resolved
not to carry passengers till Coat Guard Marine Inspector can witness safe operation of #1 MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2012
Resolved 5 May 2012
Resolution: Replaced #2 cylinder of #MDE all test satisfactory.
[name withheld]
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 January 2012
Resolved
Remove diesel oil from aft void space bilge.
Action required: 705 - Other - as specified
Due 15 March 2012
Resolved 26 June 2012
Electrical › Electric Generation Source (service) › Generator
Issued 15 December 2010
Resolved
When docking using the electric bow thruster have the offline generator running in imediate stand by.
Action required: 705 - Other - as specified
Due 15 March 2012
Resolved 26 June 2012
Resolution: This CG-835 is now a note.
Electrical › Electric Generation Source (service) › Generator
Issued 15 December 2010
Resolved
Provide results of #1 SSDG ring inspection.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 18 March 2011
Resolution: Received report, all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 15 December 2010
Resolved
Provide results of #1 SSDG circuit breaker analysis.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 18 March 2011
Resolution: Report received, all sat, except a broken secondary contact block was noted.
Electrical › Electric Generation Source (service) › Generator
Issued 15 December 2010
Resolved
Prove proper operation of #1 SSDG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2010
Resolution: Witnessed proper operation, issued 835 to limit operations.
Electrical › Electric Generation Source (service) › Generator
Issued 6 December 2010
Resolved
The M/V DELAWARE lost ship's service generator. Issued 835 requiring them to correct this issue prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2010
Resolution: Attended vessel, witnessed repairs, all sat.
Stability › Weathertight Integrity › General
Issued 8 September 2010
Resolved
Port side midship 02 deck weather tight door not latching.
Condition: Improper/Lack of Maintenance
Due 22 September 2010
Resolved 21 October 2010
Resolution: Door tested and found all sat after repairs completed.
Communications › Public Address System › Loudspeaker
Issued 8 September 2010
Resolved
03 Deck FWD speaker is inop
Due 22 September 2010
Resolved 21 October 2010
Resolution: Verified proper operation of the forward loud speaker.
Engineering › Bilge Water Management System › Pump
Issued 8 September 2010
Resolved
Correctly splice gem sensor wiring “3” on OWS holding tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 21 October 2010
Resolution: Verified correct splice in gem sensor wiring on vessel.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 16 March 2010
Resolved
Provide paperwork of renewed test information on hydrostatic releases for IBA's when completed.
Action required: 705 - Other - as specified
Resolved 23 March 2010
Resolution: Test date 23 March 2010.
Lifesaving › Launching Appliances › Davit
Issued 16 March 2009
Resolved
Provide proof that the port side rescue davit is fit for service. Requirement has been extended to 01 July 2009. Port Captain has been in contact and is working towards a satisfactory resolution.
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 29 October 2009
Resolution: Received a report from [name withheld] stating all 5 vessels were inspected found to be in proper working order and all parts within the davits were within accepted tolerances.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 January 2009
Resolved
3 way valve by re-circulation not function properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2009
Resolution: Wittnessed proper operation of 3 way valve by re-circulation.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 October 2008
Resolved
the emergency light forward and aft of the rescue boats on both sides are not labeled with an "E".
Due 24 October 2008
Resolved 30 November 2008
Resolution: WItnessed installation of E.
Engineering › Steam Boiler (auxiliary/waste heat) › Air Heater
Issued 10 October 2008
Resolved
Boiler was not assembled after Hydo test. Must prove proper operation.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 November 2008
Resolution: Witnessed satisfactory test.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 26 September 2008
Resolved
Prove proper operation of Omni Thruster prior to use. Electric bow thruster is ok to operate.
Action required: 705 - Other - as specified
Resolved 10 October 2008
Resolution: Witnessed repairs and proper operation
Engineering › Steam Boiler (auxiliary/waste heat) › Foundation
Issued 8 July 2008
Resolved
Clean and descale deck plate below void boiler for inspection prior to putting boiler into service.
Action required: 705 - Other - as specified
Resolved 22 August 2008
Resolution: Deck plate was descaled and coated, all sat.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 25 March 2008
Resolved
The bridge and bridge wing rudder angle indicators were not reading the same. Prove proper operation of all 3 rudder angle indicators.
Action required: 705 - Other - as specified
Due 2 April 2008
Resolved 2 April 2008
Resolution: Electrician synchronized all indicators to within acceptable parameters. all sat.
Communications › Alarms/Indicators › General Alarm
Issued 25 March 2008
Resolved
Stations #5, 6 and 17 were not functioning. Prove proper operation of the general alarm stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2008
Resolved 2 April 2008
Resolution: All corrected.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 March 2008
Resolved
The shaft tachometers do not read the same. Prove proper operation of all three tachometers on the bridge.
Action required: 705 - Other - as specified
Due 2 April 2008
Resolved 2 April 2008
Resolution: Corrected.
Engineering › Thrusters › Door
Issued 25 March 2008
Resolved
Prove proper operation of bow thruster directional valve.
Action required: 705 - Other - as specified
Resolved 6 October 2008
Resolution: Received Equipment History Report from 7/8/08, all sat.
Construction/Loadline › Hull › Bottom Plating
Issued 8 January 2008
Resolved
Descale and conduct NDT (UT shot grid) IWO frame 116 to 120. Found frame 118 on portside at chine in E/R to be corroded away from hull plating. submit results of NDT and repair proposal to [name withheld] by 18 Jan 2008.
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 17 February 2008
Resolution: Received photos of temp repairs from Port [name withheld] cropped out and replaced. Pitting on hull plating arrested and coated with clear epoxy. ABS report to include temp repairs and recommendation for permanent repair timeline.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 14 June 2007
Resolved
Prove proper operation of the bow prop overspeed trip.
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 25 June 2007
Resolution: Witnessed satisfactory test.
Engineering › Steam Boiler (auxiliary/waste heat) › Firewall Tube
Issued 14 June 2007
Resolved
Make boiler available for fireside/waterside inspections.
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 25 June 2007
Resolution: Inspected satisfactory fireside/waterside.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 27 March 2007
Resolved
Prove proper operation of both bridge wing rudder angle indicators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 28 March 2007
Resolution: Corrected, attested to by Master of vessel.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 May 2006
Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge.
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote COTP zones (Guam, AK COTP zones)
Due 8 June 2006
Resolved 11 March 2009
Resolution: NTVRP #04239 provided satisfactory certification statement and removed the remote COTP zones as intended areas of operation from the NTVRP. Vessel issued IOA, expires 03/12/2011.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 March 2006
Resolved
Prove proper operation of engine room fixed CO2 system time delay, failed to meet allowable limits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Resolution: System repaired and tested. Sat.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 30 March 2006
Resolved
Prove proper operation of car deck fixed sprinkler system, not tested during COI exam due to Fixed CO2 system exposed for repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Resolution: Tested, all sat.
Engineering › Steam System (auxiliary) › Piping
Issued 30 March 2006
Resolved
Overdue for hydrostatic test on all boilers.
Action required: 705 - Other - as specified
Resolved 26 June 2006
Resolution: [name withheld] witnessed hydrotest on both boilers on 26 June 2006.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 28 February 2006
Resolved
Provide six liferafts with valid servicing dates for the starboard side. Vessel restricted to carrying not more than 312 passengers until requirement is met.
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 6 March 2006
Resolution: Received fax from Port Captain of certifications for 3 IBA''s and a statement that they were installed on 06MAR06.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 28 February 2006
Resolved
ONE COUPLING IN THE BOW THRUSTER SPACE WAS NOT OF SCHEDULE 80 PIPE. PROVE IT MEETSS THE PRINT OR REPLACE WITH SCHEDULE 80 PIPE.
Action required: 705 - Other - as specified
Resolved 25 July 2006
Resolution: Pipe fitting found to meet specs for blue prints. S/S fitting is schedule 80 pipe.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 8 November 2005
Resolved
INSTALL MISSING LOCK NUTS ON STERN TUBE STUFFING BOX
Due 25 November 2005
Resolved 9 November 2005
Resolution: LOCK NUTS WERE INSTALLED
Deck/Cargo › Holds/Tanks › Scuttle
Issued 25 October 2005
Resolved
MAKE SCUTTLE WATER TIGHT IN BOW THRUSTER COMPT.
Due 25 November 2005
Resolved 9 November 2005
Resolution: SCUTTLE IS WATER TIGHT.
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 25 October 2005
Resolved
MAKE PROPER CONNECTION WITH HOSE AND FITTING ON JACKET WATER HEATER SYSTEM
Due 25 November 2005
Resolved 9 November 2005
Resolution: PROPER HOSE AND FITTING INSTALLED.
Fire Fighting › Firemans Outfit › Axe
Issued 28 July 2004
Resolved
Restencil fire axes at fire stations #8 and #10.
Due 28 August 2004
Resolved 18 November 2004
Resolution: Visually inspected axes at station #8 and #10. Confirmed that they have been labeled with vessel name using vinyl lettering.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 July 2004
Resolved
Replace missing "E" on emergency light outside emergency generator space.
Due 28 August 2004
Resolved 18 November 2004
Resolution: Verified that "E" is in place on light outside emergency generator space.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 April 2004
Resolved
Stencil F/O transfer line on stern with hydro date and pressure.
Due 5 May 2004
Resolved 28 July 2004
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 5 April 2004
Resolved
Prove proper operation of high temp alarm on #1 S/S generator.
Due 5 May 2004
Resolved 28 July 2004
Engineering › Lubricating Oil Service System › Gauge
Issued 5 April 2004
Resolved
Prove proper operation of #2 s/s generator low lube oil pressure visual indicator.
Due 5 May 2004
Resolved 28 July 2004
Communications › Audible Communications › SPD (Other)
Issued 5 April 2004
Resolved
Prove proper operation of Engine Room main control PA speaker.
Due 5 May 2004
Resolved 28 July 2004
Engineering › Fuel Oil Service System
Issued 3 December 2003
Resolved
Repair fuel leak on Bow Thruster block. LEGACY COMPONENT DESC: Piping
Due 3 January 2004
Resolved 10 February 2004
Resolution: Operational tested Bow Thruster engine. Fuel leak repaired and tested sat.
Electrical
Issued 3 December 2003
Resolved
Prove proper operation of #2 generator High Water Temperature alarm light in control room.
Due 3 January 2004
Resolved 5 April 2004
Resolution: Alarm light repaired and tested satisfactory.
Engineering
Issued 3 December 2003
Resolved
Clean ventilation and drainage tubes in steering gear room.
Due 3 January 2004
Resolved 5 April 2004
Resolution: Ventilation and drainage tubes have been cleaned.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 May 2003
Resolved
Original DOC not retained on board vessel.
Condition: Placed in Improper Service
Due 7 May 2003
Resolved 7 May 2003
Resolution: Proper DOC placed on board vessel.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 7 May 2003
Resolved
Original/certified copy of COFR not on board vessel at time of inspection.
Condition: Placed in Improper Service
Due 7 May 2003
Resolved 7 May 2003
Resolution: Certified copy of COFR placed on vessel prior to completion of inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 May 2003
Resolved
Time delay on CO2 for bow thruster room not releasing CO2 within proper time requirements.
Condition: Improper/Lack of Maintenance
Due 7 May 2003
Resolved 7 May 2003
Resolution: Attending fire representative corrected time delay for bow thruster room prior to completion of inspection.
Lifesaving › Launching Appliances › Block
Issued 7 May 2003
Resolved
Improper size shackel used on launching arrangement of starboard rescue boat not allowing proper safe lowering of rescue boat.
Condition: Improper Installation
Due 7 May 2003
Resolved 7 May 2003
Resolution: Shackle replaced with proper equipment and retested properly prior to completion of inspection.
Fire Fighting › Miscellaneous Items
Issued 7 May 2003
Resolved
Fire plan for vessel not properly posted.
Condition: Unknown
Due 7 May 2003
Resolved 7 May 2003
Resolution: Fire plan properly posted prior to completion of the inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2003
Resolved
Asprin and eye wash in first aid kit expired.
Condition: Unknown
Due 7 May 2003
Resolved 7 May 2003
Resolution: New asprin and eye wash placed in first aid kit prior to the completion of the inspection.
Engineering › Steam System (auxiliary)
Issued 7 May 2003
Resolved
Proper operational test and hydrostatic relief tests to be conducted on all boiler relief valves. To be completed prior to operating. LEGACY COMPONENT DESC: Valve, Relief
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 August 2003
Resolution: TEST OF RELIEF VALVES ON #1 & 2 BOILERS SAT.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 May 2002
Resolved
Replaced retro-reflective material on 122 Adult and 15 Child life jackets.
Condition: Unknown
Due 22 May 2002
Resolved 22 May 2002
Resolution: Replaced retro-reflective tape as needed on life jackets.
Fire Fighting › Nozzles › Condition
Issued 21 May 2002
Resolved
Replace 2 1/2" fire nozzle on fire station #1.
Condition: Unknown
Due 22 May 2002
Resolved 22 May 2002
Resolution: 2 1/2" fire nozzle on fire station #1 replaced.
Communications › Alarms/Indicators › General Alarm
Issued 21 May 2002
Resolved
Repair general alarm # 17.
Condition: Damaged By Earlier Event
Due 22 May 2002
Resolved 22 May 2002
Resolution: General alarm #17 repaired.
Lifesaving › Lifeboat Equipment
Issued 21 May 2002
Resolved
Replace Aspirin, eyewash and fire extinguisher in starboard lifeboat. LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Due 22 May 2002
Resolved 22 May 2002
Resolution: Aspirin, eyewash and fire extinguisher replaced in starboard lifeboat.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 21 May 2002
Resolved
Replace aspirin, eyewash and search light in port rescue boat.
Condition: Unknown
Due 22 May 2002
Resolved 22 May 2002
Resolution: Aspirin, eyewash and search light replaced in port rescue boat.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 19 February 2002
Resolved
Install a fixed CO2 firefighting system diagram for the engine room. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 19 March 2002
Resolved 22 May 2002
Resolution: Diagram completed and affifed at CO2 station.
Operations/Management › Pollution
Issued 19 February 2002
Resolved
Remove plastic garbage cans from car deck. LEGACY COMPONENT DESC: Control of Garbage
Condition: Unknown
Due 19 March 2002
Resolved 22 May 2002
Resolution: Plastic cans removed from car deck.
Lifesaving
Issued 7 August 2001
Resolved
REPLACE HAND LINE ON LIFE RING. (CAR DECK STBD/FWD)
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Construction/Loadline
Issued 7 August 2001
Resolved
REPLACE GASKETS ON ALL WATERTIGHT DOORS ON CARD DECK.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 7 August 2001
Resolved
REPLACE RETRO-TAPE ON LIFE RING. (01 DECK PORT SIDE)
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Fire Fighting
Issued 24 May 2001
Resolved
PROVIDE A REVISED AND ACCURATE FIRE CONTROL PLAN FOR U.S. COAST GUARD APPROVAL.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Lifesaving
Issued 24 May 2001
Resolved
PROVIDE A REVISED AND ACCURATE LIFESAVING DETAIL PLAN.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Lifesaving
Issued 24 May 2001
Resolved
PROVIDE A NEW PLAN FOR THE MODIFIED PROCEDURES OF LAUNCHING ALL THE INFLATABLE BUOYANT APPARATUS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Fire Fighting
Issued 21 February 2001
Resolved
LABEL THE CO2 ALARM IN THE EMERGENCY GENERATOR ROOM WITH THE FOLLOWING, "CARBON DIOXIDE FIRE APPARATUS"._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 21 February 2001
Resolved
POST INSTRUCTIONS FOR ACTIVATION OF CO2 SYSTEM FOR THE EMERGENCY GENERATOR ROOM._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Electrical
Issued 21 February 2001
Resolved
CONDUCT TEST OF EMERGENCY GENERATOR LUBE OIL ALARM._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Electrical
Issued 21 February 2001
Resolved
CONDUCT TEST OF EMERGENCY LIGHTING USING THE EMERGENCY GENERATOR UNIT._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Accommodation/Occupational Safety
Issued 21 February 2001
Resolved
PROVIDE A MEANS OF CLOSURE FOR THE EMERGENCY GENERATOR ROOM VENTS ON TOP OFTHE SPACE THAT WILL NOT EXPOSE PERSONNEL TO FIRE WHILE CLOSING._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 21 February 2001
Resolved
LABEL THE CO2 ALARM IN THE EMERGENCY GENERATOR ROOM WITH THE FOLLOWING "WHEN ALARM SOUNDS - VACATE AT ONCE CARBON DIOXIDE BEING RELEASED"
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 21 February 2001
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO DECK DRY PIPING SYSTEM PRIOR TO LOADING CARGO AND PASSENGERS._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 21 February 2001
Resolved
CONDUCT FULL FUNCTION TEST OF CAR DECK DRY PIPE SPRINKLER SYSTEM TO EXAMINESPRAY PATTERN, WHILE SIMULTANEOUSLY SUPPLYING FIRE WATER FROM THE TWO HIGHEST FIRE HOSE OUTLETS IN A MANNER SIMILAR TO THE DESCRIBED IN 46CFR76.10-5(C) PER 46CFR76.23-10D PRIOR TO LOADING CARGO AND PASSENGERS._x001C_
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Electrical
Issued 16 August 2000
Resolved
REPAIR "E" LIGHT IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Electrical
Issued 16 August 2000
Resolved
REPAIR COVER ON ELECTRICAL JUNCTION BOX ON STBD RESCUE BOAT DAVIT (LIMIT SWITCH).
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Fire Fighting
Issued 11 May 2000
Resolved
PROVIDE TWO ADDITIONAL GENERAL QUARTERS ALARM BELLS AT THE AFT END OF 02 DECK AND 03 DECK TO BE HEARD WHILE EMEGENCY GENERATOR IS RUNNING.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Fire Fighting
Issued 11 May 2000
Resolved
PROVIDE CORRECT FIRE EXTINQUISHER BRACKET FOR THE EXTINQUISHER BEHIND THE DELI COUNTER ON THE O2 DECK.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Documentation
Issued 16 February 2000
Resolved
RENEW CLASS CERTIFICATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Accommodation/Occupational Safety
Issued 16 February 2000
Resolved
SECURE ALL RECYCLING BINS IN PASSENGER AREAS.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Fire Fighting
Issued 2 September 1999
Resolved
CLEAN OUT TWO CLOGGED/MALFUNCTIONING SPRINKLER HEADS AT THE END OF EACH LINE ON THE PORT SIDE CAR DECK SYSTEM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999
Resolved
RE-INSTAL THE BRIDGE HEAD ELECTRIC HEATER OR REMOVE THE DEAD END WIRING IN THAT SPACE.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Documentation
Issued 2 September 1999
Resolved
REVISE AND POST AN APPROVED FIRE PLAN THAT SHOWS THE LOCATION OF ALL GENERAL QUARTERS EMERGENCY BELLS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Documentation
Issued 2 September 1999
Resolved
POST REQUIRED DOCUMENTS AT OPERATING STATION.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 2 September 1999
Resolved
REPAIR ALL THREE GENERAL ALARM BELLS ON THE VESSELS BOAT DECK.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Construction/Loadline
Issued 2 September 1999
Resolved
ADJUST ALL MAIN DECK WATERTIGHT DOORS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Engineering
Issued 2 September 1999
Resolved
HYDROSTATIC TEST ALL ENGINE ROOM PRESSURE VESSELS.
Condition: Unknown
Due 2 October 1999
Resolved 17 September 1999
Fire Fighting
Issued 12 May 1999
Resolved
REPAIR THREE GENERAL QUARTERS ALARM BELLS ON THE MAIN DECK.
Condition: Unknown
Due 11 June 1999
Resolved 14 June 1999
Engineering
Issued 12 May 1999
Resolved
DEMONSTRATE OPERATIONAL TEST ALL BOILER ALARMS AND SAFETIES FOR #1 AND #2 HEATING BOILERS PRIOR TO PUTTING IN SERVICE.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Fire Fighting
Issued 12 May 1999
Resolved
PROVIDE CO2 ENTRY WARNING SIGN ON BOW THRUSTER ROOM WATER TIGHT DOOR.
Condition: Unknown
Due 11 June 1999
Resolved 14 June 1999
Fire Fighting
Issued 19 February 1998
Resolved
Provide and post operating instructions for fixed Extng. system in galley space.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Electrical
Issued 19 February 1998
Resolved
Repair #2 ship service generator overspeed trip selinoid.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Fire Fighting
Issued 19 February 1998
Resolved
Install door release placard on aft fire safety doors #'s 2 and 3.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Engineering
Issued 19 February 1998
Resolved
Replace plastic sight glass on engine room lube oil and hydraulic tanks with flame resistant material.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Accommodation/Occupational Safety
Issued 19 February 1998
Resolved
Provide metal trash cans or acceptable flame retardant meterial in accommodations, food service area, and engine room.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Accommodation/Occupational Safety
Issued 19 February 1998
Resolved
Provide ship wide waste disposal plan and waste disposal log.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Electrical
Issued 19 February 1998
Resolved
Repair chafted electrical cords on warmers in food service area, and reroute cords to prevent future chafting.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 9 February 1998
Resolved
LABEL ALL VENTS ON CAR DECK.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Engineering
Issued 9 February 1998
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR 15PPM ALARM.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Fire Fighting
Issued 9 February 1998
Resolved
ADD INSTRUCTION TO "CLOSE VENT COVERS" TO CO2 CONTROLS FOR BOW THRUSTER ROOM.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Navigation
Issued 9 February 1998
Resolved
CORRECT SIDE RUNNING LIGHTS SO BULB IS IN FOCAL PLANE.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Fire Fighting
Issued 9 February 1998
Resolved
STENCIL "IN CASE OF FIRE CLOSE VENTS" ON BOW THRUSTER ROOM VENTS.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Engineering
Issued 21 November 1997
Resolved
Properly install sight glass penetration for lube oil storage tank.
Condition: Unknown
Due 25 November 1997
Resolved 25 November 1997
Lifesaving
Issued 8 May 1997
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVE PROPER OPERATION OF PORT AND STARBOARD RESCUE BOAT DEADMAN PULLS AND PORT BRAKE HANDLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Lifesaving
Issued 8 May 1997
Resolved
PROVIDE PROOF OF PROPER SERVICING OF PORT INBOARD IBA.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Documentation
Issued 17 March 1997
Resolved
PROVIDE TO LOCAL [name withheld] OF CHANGES MADE DURING FEB 97 DOCKSIDE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Documentation
Issued 17 March 1997
Resolved
PROVIDE UPDATED MSC STABILITY LETTER REFLECTING RESULTS FROM MAR 97 DEADWEIGHT SURVEY PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 17 March 1997
Resolved
PROVIDE FACTORY (BABSON) PLACARD ON OILY WATER SEPERATOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Navigation
Issued 21 November 1996
Resolved
PROVE PROPER OPERATION OF FATHOMETER TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 21 November 1996
Resolved
REPAIR/REPLACE MOTOR MOUNT FOR EMERGENCY FIREPUMP.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Engineering
Issued 2 May 1996
Resolved
REPAIR LEAKING ISOLATION VALVES FOR #2 AIR RECEIVER.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996
Resolved
PROVE PROPER OPERATION OF CO2 SYSTEM FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996
Resolved
REPAIR FIRE DAMPER HANDLE FOR CENTER ENGINEROOM VENT.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Engineering
Issued 2 May 1996
Resolved
PROVE PROPER OPERATION OF #2 MDE LOW L/O ALARM.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Unknown
Issued 2 May 1996
Resolved
CONDUCT A FIRE DRILL.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Electrical
Issued 2 May 1996
Resolved
REPAIR/REPLACE NON-CONDUCTIVE MATTING IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Engineering
Issued 27 February 1996
Resolved
PROVE PROPER OPERATION OF PROPULSION CONTROLS FOR AFT STEERING STATION.
Condition: Unknown
Due 1 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 27 February 1996
Resolved
PROVE PROPER OPERATION OF PRIMARY BILGE PUMP.
Condition: Unknown
Due 1 March 1996
Resolved 5 March 1996
Navigation
Issued 27 February 1996
Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR FOR AFT STEERING STATION.
Condition: Unknown
Due 1 March 1996
Resolved 5 March 1996
Lifesaving
Issued 28 November 1995
Resolved
REJECTED 106 ADULT AND 03 CHILD PFD'S. AFTER FULL VSL COUNT OF PFD'S THE VSL WAS ONLY 94 ADULT SHORT. REPLACE 94 ADULT TYPE I PFD'S. UNTIL THAT TIME, PASSENGER COUNT SHALL NOT EXCEED 720.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Lifesaving
Issued 28 November 1995
Resolved
REPAIR GENERAL ALARM IN FRONT OF HOUSE.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Fire Fighting
Issued 28 November 1995
Resolved
REPLACE ONE SECTION OF 2.5" FIRE HOSE WITH APPROVED REPLACEMENT.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Engineering
Issued 24 October 1995
Resolved
PROVE PROPER OPERATION OF FLAME FAILURE ALARM INSIDE ENGINEROOM CONTROL BOOTH.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Engineering
Issued 31 August 1995
Resolved
PRIOR TO OPERATING THE VOID BOILER CONDUCT OPERATIONAL TESTS TO INCLUDE ALLALARMS, SHUTDOWNS AND RELIEF VALVE SETTING.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Lifesaving
Issued 31 August 1995
Resolved
PROVE PROPER OPERATION OF REMOTE VENT SHUTDOWNS LOCATED ON THE BRIDGE.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Engineering
Issued 31 August 1995
Resolved
PRIOR TO OPERATING THE HOTEL BOILER CONDUCT OPERATIONAL TESTS TO INCLUDE ALL ALARMS, SHUTDOWNS AND RELIEF VALVE SETTING.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Fire Fighting
Issued 16 May 1995
Resolved
PROVE PROPER OPERATION OF THE FIREMAIN PRESSURE GAUGE AT FIRE STATION #3.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Fire Fighting
Issued 16 May 1995
Resolved
PROVIDE PROPER OPERATION OF FIXED ENGINE ROOM CO2 SYSTEM.
Condition: Unknown
Due 17 May 1995
Resolved 24 May 1995
Navigation
Issued 16 May 1995
Resolved
PROVE PROPER OPERATION OF BRIDGE RADAR EQUIPMENT.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Lifesaving
Issued 16 May 1995
Resolved
PRIOR TO CARRYING MORE THAN 529 PASSENGERS, PROVIDE AN ADDITIONAL 171 USCG APPROVED TYPE I ADULT-SIZE LIFE PRESERVERS.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Engineering
Issued 16 May 1995
Resolved
PROVIDE DOCUMENTATION THAT ALL PIPING MATERIALS USED IN THE FUEL FILTER MODIFICATION ARE ACCEPTABLE UNDER 46 CFR 56.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Engineering
Issued 16 May 1995
Resolved
PROVE PROPER OPERATION OF THE TACHOMETER ON THE STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Construction/Loadline
Issued 16 May 1995
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF THE BILGE PIPING SYSTEM IN OBTAINING SUCTION ON THE FOREPEAK VOID.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Navigation
Issued 8 December 1994
Resolved
MAKE PERMANENT REPAIRS TO FATHOMETER AND PROVE PROPER OPERTAION TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Engineering
Issued 12 September 1994
Resolved
PRIOR TO OPERATING EACH AUXILARY BOILER, CONDUCT OPERATIONAL TESTS OF ALARMS AND SAFETY DEVICES TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Electrical
Issued 12 September 1994
Resolved
REPAIR THE FRAYED WIRE CONNECTION ON THE AFT CENTER CAR DECK CARGO LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Construction/Loadline
Issued 12 September 1994
Resolved
PROVIDE COVERS FOR ALL CAR DECK GOOSE NECK VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Fire Fighting
Issued 12 September 1994
Resolved
PROVIDE A LIGHTED EXIT SIGN OVER THE AFT DOOR LEADING FROM THE DELI TO THE LIDO DECK AS REQUIRED BY 46 CFR 78.47-40(a)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Documentation
Issued 12 September 1994
Resolved
POST THREE COPIES OF THE STATION BILL IN CONSPICUOUS LOCATIONS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Navigation
Issued 12 September 1994
Resolved
CALIBRATE THE PORT BRIDGE WING RUDDER ANGLE INDICATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Construction/Loadline
Issued 12 September 1994
Resolved
REPAIR THE AUDIBLE ALARM FOR THE OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 27 June 1994
Resolved
ISSUED REQUIREMENT ON 18JUN94 TO PROVIDE 232 ADDITIONAL ADULT PFD'S. APPROVED 144 ON 18JUN AND 97 ON 27JUN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Lifesaving
Issued 19 June 1994
Resolved
PRIOR TO CARRYING MORE THAN 582 PERSONS, PROVIDE AN ADDITIONAL 232 USCG APPROVED ADULT-SIZE TYPE I LIFE PRESERVERS.
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Deck/Cargo
Issued 17 June 1994
Resolved
CONDUCT HYDRO OF HEATING BOILERS.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Fire Fighting
Issued 17 June 1994
Resolved
MAKE FIREMAN OUTFITS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Lifesaving
Issued 17 June 1994
Resolved
MAKE SCBA'S AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Electrical
Issued 17 June 1994
Resolved
PROVIDE EMERGENCY GEN WITH SHUTDOWNS IN ACCORDANCE WITH 46 C.F.R. 112.50(2)(h).
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Fire Fighting
Issued 17 June 1994
Resolved
PROVIDE COGNIZANT OCMI WITH APPROVED FIRE PORTECTION PLAN.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Deck/Cargo
Issued 17 June 1994
Resolved
MAKE HEATING BOILERS AVAILABLE TO THE COAST GUARD FOR WATER & FIRE SIDE EXAMS.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Lifesaving
Issued 17 June 1994
Resolved
MAKE PFD'S AVAILABLE TO COAST GUARD FOR INSPECTION.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Documentation
Issued 6 December 1993
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PRESENT VESSEL FOR REQUIRED INSPECTION (THIRD QUARTERLY RIN OR COI).
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Lifesaving
Issued 22 September 1993
Resolved
CONDUCT A LIFEBOAT DRILL USING THE #2 OAR PROPELLED LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Engineering
Issued 16 June 1993
Resolved
PRIOR TO USING THE WAYWOFF BOILER CONDUCT TESTS IN ACCORDANCE WITH 46 CFR 61.35._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Fire Fighting
Issued 18 March 1993
Resolved
CONDUCT TEST OF CARDECK SPRINKLER SYSTEM. SYSTEM TESTS NOT CONDUCTED DUE TOFREEZING TEMPERATURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 18 March 1993
Resolved
CONDUCT HYDROSTATIC TEST OF ALL FIRE HOSES. TESTS NOT CONDUCTED DUE TO FREEZING TEMPERATURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 18 March 1993
Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR CONDUCT ANNUAL SERVICING OF ALL FIRE FIGHTING EQUIPMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Lifesaving
Issued 18 February 1993
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE DEMONSTRATE SATISFACTORY OPERATION OFBOTH REPLACED LIFEBOATS (SERIAL NUNBERS 2350 & 2366). UPON COMPLETION OF OPERATIONAL DEMONSTRATION CARRY OUT BOAT DRILL IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Fire Fighting
Issued 18 February 1993
Resolved
MARK THE MANUAL VENTILATION DAMPER CLOSURES FOR THE MEN'S AND WOMEN'S HEAD VENTS LOCATED IN THE EMERGENCY GENERATOR SPACE - IDENTIFY ON THE EXTERIOR OF THE EMERGENCY GENERATOR COMPARTMENT THAT THESE CLOSURES ARE WITHIN THE COMPARTMENT OR MAKE CLOSURES OPERABLE FROM OUTSIDE THE COMPARTMENT.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Lifesaving
Issued 18 February 1993
Resolved
SEPARATE LIFE PRESERVERS - ADULT/CHILD - WITHIN EACH STOWAGE CONTAINER ON VESSEL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Fire Fighting
Issued 18 February 1993
Resolved
MAKE MEN'S HEAD VENTILATION MANUAL DAMPER OPERATIONAL FROM AN ACCESSIBLE LOCATION. PROVIDE HANDLE/LOCKING DEVICE FOR WOMEN'S HEAD VENT LOCATED IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Fire Fighting
Issued 18 February 1993
Resolved
REPAIR SHUT-OFF VALVE SEAT FOR #5 FIRE STATION HYDRANT LOCATED STBD FWD MAIN DECK DUE TO LEAK BY OF FIRE WATER INTO FIRE HOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Lifesaving
Issued 18 February 1993
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE DEMONSTRATE SATISFACTORY WEIGHT TEST OF REPLACED PORT AND STBD LIFEBOATS (SERIAL NUMBERS 2350 & 2366).
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Fire Fighting
Issued 9 November 1992
Resolved
REPAIR CRACKED CAR DECK SPRINKLER PIPE, ZONE #1, CENTERLINE JUST AFT OF THE2 INCH UNION. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Fire Fighting
Issued 9 November 1992
Resolved
REPAIR THE GENERAL ALARM BELL ON THE EMERGENCY GENERATOR ROOM. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Construction/Loadline
Issued 9 November 1992
Resolved
REMOVE EXCESS OIL FROM THE STEERING FLAT BILGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Engineering
Issued 11 August 1992
Resolved
REMOVE EXCESS OIL FROM EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 11 August 1992
Resolved
REMOVE EXCESS OIL AND WATER FROM BILGES IN AFTER STEERING.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Engineering
Issued 11 August 1992
Resolved
OPEN MOUNTS ON AFT BOILER, CONDUCT HYDROSTATIC TEST. CONDUCT OPERATIONAL TEST ON BOTH BOILERS.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 11 August 1992
Resolved
INSTALL BLANK COVER, WHERE BREAKER WAS REMOVED FROM 115V DISTRIBUTION PANELBY FORWARD BOILER.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Engineering
Issued 11 August 1992
Resolved
PRESENT PROPOSAL TO RENEW TWO TUBES ON AFT BOILER TO [name withheld], CONDUCT REPAIRS AND CONDUCT HYDROSTATICT TEST.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Lifesaving
Issued 15 May 1992
Resolved
CONDUCT WEIGHT TEST ON THE STARBOARD LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1992
Resolved 26 May 1992
Fire Fighting
Issued 15 May 1992
Resolved
REPAIR HOLE IN SPRINKLER SYSTEM ON CAR DECK, ZONE #1, MIDSHIP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1992
Resolved 26 May 1992
Engineering
Issued 15 May 1992
Resolved
CONDUCT HYDROTEST ON BOTH BOILERS IN THE PRESENCE OF COAST GUARD INSPECTORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Deck/Cargo
Issued 15 May 1992
Resolved
PROVIDE SECURING BRACKET ON THE CHAIN GUARD ON THE PORT DAVIT WINCH TO PREVENT VIBRATION DAMAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1992
Resolved 26 May 1992
Construction/Loadline
Issued 21 February 1992
Resolved
SUBMIT PLANS TO CORRECT PROBLEM WITH ELECTRICAL BILGE PUMP SUCTION.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Engineering
Issued 21 February 1992
Resolved
REPAIR FUEL OIL LEAK ON SUCTION LINE FROM DAY TANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Lifesaving
Issued 21 February 1992
Resolved
VESSEL MUST STRIP, CLEAN AND OVERHAUL BOTH LIFEBOATS.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Electrical
Issued 14 November 1991
Resolved
REPLACE BROKEN BULB IN EMERGENCY LIGHT FIXTURE IN BOW THRUSTERROOM.
Condition: Unknown
Due 14 November 1991
Resolved 14 November 1991
Fire Fighting
Issued 14 November 1991
Resolved
FREE UP FIRE DAMPNER STBD SIDE FWD VENT FOR ENGINEROOM.
Condition: Unknown
Due 14 November 1991
Resolved 14 November 1991
Electrical
Issued 14 November 1991
Resolved
DETERMINE CAUSE AND READJUST HIGH FREQUENCY ON EMERGENCY GENERATOR.
Condition: Unknown
Due 14 November 1991
Resolved 14 November 1991
Electrical
Issued 14 November 1991
Resolved
MARK EMERGENCY LIGHTING IN FOLLOWING AREAS: THREE IN ENGINEROOM, AND TWO STARBOARD SIDE AFT IN DECK LOUNGE.
Condition: Unknown
Due 14 November 1991
Resolved 14 November 1991
Engineering
Issued 19 February 1991
Resolved
RESET BOTH MAIN DIESEL ENGINE OVERSPEEDS TO MANUFACTURE SPECS OR PROVIDE_x001C_ DOCUMENTATION FROM MANUFACTURE THAT PRESENT SETTINGS ARE ACCEPTABLE.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Lifesaving
Issued 19 February 1991
Resolved
CONDUCT BOAT DRILL PRIOR TO DEPARTING FROM CAPE MAY FERRY TERMINAL ENROUTE_x001C_TO NORFOLK, VA.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Accommodation/Occupational Safety
Issued 19 February 1991
Resolved
REPAIR/REPLACE AFT SEWAGE INLET VALVE TO TANK. VALVE DOES NOT OPERATE.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Construction/Loadline
Issued 19 November 1990
Resolved
PROVIDE PROPOSAL FOR HOLES IN DECK IN WAY OF OUTER ENTRANCEWAY TO SALON, STARBOARD SIDE, ON PROMENADE DECK.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Engineering
Issued 19 November 1990
Resolved
PROVIDE AND MOUNT POLLUTION PLACARD IN VICINITY OF OILY WATER SEPARATOR AND BILGE PUMP.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Electrical
Issued 19 November 1990
Resolved
REPAIR TWO FLUORESCENT EMERGENCY LIGHTS ON VEHICLE DECK, STARBOARD SIDE, FORWARD.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Navigation
Issued 19 November 1990
Resolved
DEWATER STEERING FLATS AND CLEAR BILGE DRAIN, STARBOAD SIDE, FROM STEERING FLATS TO ENGINE ROOM.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Construction/Loadline
Issued 25 October 1990
Resolved
MAKE PERMANENT REPAIRS TO THE BULWARK AND MAIN DECK IN WAY OF THE DAMAGE. UNTIL REPAIRS ARE COMPLETED VEHICLES AND PASSENGERS SHALL BE RESTRICTED AS DESCRIBED ON THE PROPOSED SAFETY MODIFICATIONS DATED 11/1/90.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Navigation
Issued 10 September 1990
Resolved
D1-REWELD ALL SUPPORT BRACKETS TO HYDRAULIC LINES IN AFTER STEERING.
Condition: Unknown
Due 10 September 1990
Resolved 10 September 1990
Electrical
Issued 21 August 1990
Resolved
REPAIR, CLEAN, & MEG #2 GEN. IAW GOOD MARINE PRACTICE. LOAD TEST FOR AT LEAST 4 HRS. PRIOR TO PLACING IN SERVICE. NO PASSENGERS UNTIL SAT TESTS COMPLETED. REPORT RESULTS TO [name withheld] FOR USCG INSPECTIONS/TESTS.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Fire Fighting
Issued 18 May 1990
Resolved
REPAIR OR REPLACE THE VALVE AND ADAPATER FOR THE FORWARD PORT HYDRANT MARKED INT. SHORE CONNECTION.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Lifesaving
Issued 18 May 1990
Resolved
REPLACE THE HORIZONTAL BEVEL GEARS ON THE PORT SIDE DAVIT.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Accommodation/Occupational Safety
Issued 18 May 1990
Resolved
CONDUCT FIRESIDE AND WATERSIDE EXAMINATION OF BOTH BOILERS PRIOR TO PLACINGBOILER IN SERVICE NOT LATER THAN 15 OCT 90.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Accommodation/Occupational Safety
Issued 18 May 1990
Resolved
REMOVE CARDBOARD FROM AIR INTAKE OF HEATING BOILER AND DEMONSTRATE PROPER OPERATION OF BOILER PRIOR TO PLACING BOILER IN SERVICE NOT LATER THAN 15 OCT 90.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 10 May 1990
Resolved
RENEW TO ORIGINAL SCANTLING UNDER DECK STIFFENER IN WAY OF AFTER PEAK HATCH NO LATER THAT NEXT DRY DOCK.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Lifesaving
Issued 18 January 1990
Resolved
PORT LIFEBOAT #2351 RENEW/REPLACE WASTED PLATE INWAY OF BOAT PLUG. THE ABOVE REQUIREMENT EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 18 January 1990
Resolved
STBD LIFEBOAT #2384 STBD SIDE HOLE IN SHEAR PLATE 1" BELOW GUNWALE APP 4FT FWD OF STERN. THE ABOVE REQUIREMENT EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 18 January 1990
Resolved
STBD LIFEBOAT #2384 PORT SIDE METAL WASTED 1"X1" ON SHEAR PLATE AT GUN- WALE INWAY OF STERN. THE ABOVE REQUIREMENT EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 18 January 1990
Resolved
PORT LIFEBOAT #2351 STBD SIDE STERN, METAL WASTED 1"X1" ON SHEAR PLATE AT GUNWALE REPAIR/REPLACE IN KIND. THE ABOVE REQUIREMENT EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 18 January 1990
Resolved
STBD LIFEBOAT #2384 PORT AND STBD SIDE METAL WASTED 1"X1" ON SHEAR PLATE ATGUNWALE AND STEM. THE ABOVE REQUIREMENT EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 30 November 1989
Resolved
STBD LIFE BOAT#2384, STBD SIDE HOLE IN SHEAR PLATE 1INCH BELOW GUNWALE APP. 4FT. FORWARD OF STERN.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
STBD LIFE BOAT32384, PORT SIDE METAL WASTED 1"X1" ON SHEAR PLATE AT GUNWALEINWAY OF STERN.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
PORT LIFE BOAT #2351, REPLACE/RENEW WASTED METAL INWAY OF BOAT PLUG.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
PORT LIFE BOAT 32351, STBD SIDE STERN, METAL WASTED 1"X1" ON SHEAR PLATE AT GUNWALE.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
STBD LIFE BOAT#2384, PORT AND STBD SIDE FWD. METAL WASTED 1"X1" ON SHEAR PLATE AT GUNWALE AND STEM.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Accommodation/Occupational Safety
Issued 18 May 1989
Resolved
PERMANENTLY WIRE REEFER CONDENSATE PAN HEATER. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Fire Fighting
Issued 18 May 1989
Resolved
HYDRO TEST OR REPLACE CO2 BOTTLE F100-5103 LOCATED ON VEHICLE DECK. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Construction/Loadline
Issued 18 May 1989
Resolved
GRIND OUT AND REWELD CRACKED WELDS IN FOREPEAK, FRAME 6 AT PORT INVERSE CHION CUT OUT. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Unknown
Issued 18 May 1989
Resolved
GRIND OUT AND REWELDED CRACKED WELDS IN #1 VOID, FRAME 7 OUTBOARD STAND CHION. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Unknown
Issued 18 May 1989
Resolved
CROP OUT AND PERMANENTLY REPAIR COPPER NICKEL WATER LINE PATCHES TOTAL (4) REPAIRS IN #4 VOID (2P - 2 STBD) (1) REPAIR IN #6 VOID (C.L.) ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Construction/Loadline
Issued 18 May 1989
Resolved
REPAIR VEHICLE DECK HATCH LIP CRACKS VOIDS - #1 - #4 - #5 - #6 - #7 - #8. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Construction/Loadline
Issued 18 May 1989
Resolved
AUDIO GAGE UNDER DECK STIFFENER IN WAY OF AFTER PEAK HATCH. NO LATER THAN NEXT DRYDOCK.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Accommodation/Occupational Safety
Issued 18 May 1989
Resolved
CLEAN GALLEY EXHAUST DUCTS. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Accommodation/Occupational Safety
Issued 18 May 1989
Resolved
MOUNT GALLEY TOASTERS. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Accommodation/Occupational Safety
Issued 18 May 1989
Resolved
REPLACE CRACKED AFT GALLEY REEFER TIMER CORD. ORIGINAL COMPLIANCE DATE IS 18 JUN 89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Unknown
Issued 18 May 1989
Resolved
CLEAN #6 VOID BILGE SUCTION STRAINER. ORIGINAL COMPLIANCE DATE IS 18JUN89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Unknown
Issued 18 May 1989
Resolved
REPAIR HYDRAULIC LINE LEAKS IN #7 VOID AND WIPE UP OK. ORIGINAL COMPLIANCE DATE IS 18JUN89.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Lifesaving
Issued 3 March 1989
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, PROVIDE NUMBER OF LIFERAFT'S ACCORDING TO VESSEL'S COI.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Lifesaving
Issued 18 November 1988
Resolved
REPAIR OR REPLACE IN KIND STARBOARD LIFEBOAT PORT SIDE AFT WASTED METAL AT SHEAR PLATE AT GUNWALE AND STERN.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Electrical
Issued 18 November 1988
Resolved
MAKE P.A. SYSTEM JUNCTION BOX WEATHERTIGHT. BOX IS ON AFT SIDE OF HOUSE ONBOAT DECK. (ORIGINAL COMPLIANCE DATE IS 18DEC88)
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
REPAIR OR REPLACE IN KIND STARBOARD LIFEBOAT, STARBOARD SIDE AFT WASTED METAL AT SHEAR PLACE AT GUNWALE AND STERN.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
REPAIR OR REPLACE IN KIND PORT LIFEBOAT, PORT SIDE FORWARD WASTED METAL AT SHEAR PLATE AT GUNWALE AND STEM.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
PRIOR TO CARRYING PASSENGERS THE PORT AND STARBOARD LIFEBOATS OF M/V DELAWARE MUST BE REPAIRED OR REPLACED.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Electrical
Issued 18 November 1988
Resolved
REPAIR EMERGENCY GENERATOR SPACE LOUVER DAMPER ACTIVATORS AND PORT SIDE OVERHEAD OPERATOR. DEMONSTRATE WITH EMERGENCY GENERATOR RUNNING AND DOOR CLOSED. (ORIGINAL COMPLIANCE DATE IS 18DEC88)
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
DEMONSTRATE ABILITY TO PUMP BILGES OF SPACES OTHER THAN ENGINEROOM, INCLUDING BOW THRUSTER/EMERGENCY FIRE PUMP SPACE. (ORIGINAL COMPLIANCE DATE IS 18DEC88)
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
REPAIR OR REPLACE IN KIND STARBOARD LIFEBOAT, STARBOARD SIDE FORWARD WASTED METAL AND TWO HOLES AT SHEAR PLACE AT GUNWALE AND STEM.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 May 1988
Resolved
DEMONSTRATE ALL OPERATIONAL SAFETIES ON BOTH BOILERS.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Electrical
Issued 18 May 1988
Resolved
PROPERLY CONNECT OR PROPERLY TERMINATE DEAD END CABLE IN MAIN ENGINE EXPANSION TANK SPACE. (ORIGINAL COMPLIANCE DATE IS 01JUN88)
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Engineering
Issued 18 May 1988
Resolved
MAKE BOTH BOILERS AVAILABLE FOR FIRESIDE AND WATERSIDE INSPECTIONS.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Fire Fighting
Issued 18 May 1988
Resolved
REPLACE TWO CRIMPED FLEXIBLE LOOPS ON THE FIXED CO2 BANK. (FIRST ONE AND THIRD ONE AFT FROM THE FORWARD AND TOWARDS THE CERTERLINE.) (ORIGINAL COMPLIANCE DATE IS 21MAY88)
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Electrical
Issued 18 May 1988
Resolved
DEMONSTRATE OPERATION OF EMERGENCY LIGHT ON BULKHEAD ON STARBOARD SIDE OF ELECTRICAL SWITCHBOARD IN ENGINEROOM. (ORIGINAL COMPLIANCE DATE IS 25MAY88)
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Construction/Loadline
Issued 18 May 1988
Resolved
RENEW SUPPORT BRACKET FOR THE OFF VOID BILGE SUCTION LINE. (ORIGINAL COMPLIANCE DATE IS 01JUN88)
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Electrical
Issued 18 May 1988
Resolved
PROVE PROPER OPERATION OF #1 AND #2 SHIPS SERVICE GENERATORS HIGH COOLING WATER TEMPERATURE ALARM AND SHUTOFF. (ORIGINAL COMPLIANCE DATE IS 25MAY88)
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Unknown
Issued 20 April 1988
Resolved
PROVIDE APPROVED PLANS ON THE INSTALLATION OF THE OILY WATER SEPARATOR AND THE BRIDGE WING EXTENSIONS AND CHART ROOM ADDITIONS.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Fire Fighting
Issued 20 April 1988
Resolved
REPLACE REGULATOR VALVE FOR FIXED CO2 SYSTEM IN EMERGENCY GENERATOR SPACE. VESSEL IS NOT TO CARRY PASSENGERS UNTIL REGULATOR IS REPLACED.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Fire Fighting
Issued 22 February 1988
Resolved
REPAIR AND RETEST BROKEN SPRINKLER PIPES FOR THE STARBOARD AND CERTERLINE VEHICLES ZONES.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 22 February 1988
Resolved
CONDUCT A FIRE AND BOAT DRILL WITH THE CREW ASSIGNED FOR THE COASTWISE VOYAGE TO NORFOLK, VA PRIOR TO THE VESSEL DEPARTING THE DELAWARE BAY. (ORIGINAL COMPLIANCE DATE IS 22MAR88)
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Accommodation/Occupational Safety
Issued 22 February 1988
Resolved
CLEAN PORT AND STARBOARD FALSE STACK AREAS TO REMOVE BUILD-UP OF DUST AND DIRT.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 22 February 1988
Resolved
PROVIDE 14 PERSONAL FLOATATION DEVICE LIGHTS FOR THE CREW FOR THE COASTWISE VOYAGE.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Accommodation/Occupational Safety
Issued 22 February 1988
Resolved
MAKE PERMANENT REPAIRS TO HEATING LINE AMIDSHIPS, STARBOARD SIDE, OVERHEAD OF THE VEHICLE DECK.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Electrical
Issued 22 February 1988
Resolved
REWIRE ELECTRICAL LIGHT FIXTURE IN THE MAIN ENGINE EXPANSION TRUNK SPACE OF THE ENGINE ROOM.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Fire Fighting
Issued 22 February 1988
Resolved
HYDROSTATICALLY TEST AND RESERVICE ALL PORTABLE FIRE EXTINGUISHERS THAT NOWSHOW A 1982 HYDRO DATE.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 22 February 1988
Resolved
PLACE ABOARD THE VESSEL NECESSARY NUMBER OF SURVIVAL SUITS AND FLARES PRIORTO THE VESSEL DEPARTING ON A COASTWSIE VOYAGE TO NORFOLK, VA.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 19 November 1987
Resolved
REPAIR HOLE IN #2 LIFEBOAT PRIOR TO PLACING IN SERVICE.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Navigation
Issued 16 November 1987
Resolved
TIGHTEN ALL HYDRAULIC LINE UNIONS IN THE #7 AND #8 VOIDS.
Condition: Unknown
Due 16 November 1987
Resolved 16 November 1987
Navigation
Issued 16 November 1987
Resolved
REPLACE WELDING RODS WITH PROPER SECURING DEVICES (COTTER PINS) FOR TWO NUTS ON EITHER END OF THE YOKE OF THE STEERING SYSTEM.
Condition: Unknown
Due 16 November 1987
Resolved 16 November 1987
Lifesaving
Issued 16 November 1987
Resolved
STRIP, CLEAN AND OVERHAUL BOTH LIFEBOATS.
Condition: Unknown
Due 16 November 1987
Resolved 16 November 1987
Accommodation/Occupational Safety
Issued 26 August 1987
Resolved
CLEAN GALLEY AND SERVING LINE AREA AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Construction/Loadline
Issued 26 August 1987
Resolved
REPAIR MOUNT BOLTS FOR BOW THRUSTER SPACE VENT COVERS.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Engineering
Issued 26 August 1987
Resolved
CLEAN ENGINE ROOM BILGES OF OIL DEBRIS AND OTHER CONTAMINATES.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Construction/Loadline
Issued 26 August 1987
Resolved
REPAIR CRACK IN WELD, FORE PEAK FORWARD PARTIAL BULKHEAD STARBOARD SIDE AT INVERTED CHINE.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Fire Fighting
Issued 26 August 1987
Resolved
RESTENCIL GENERAL ALARM BELL ON CAR DECK STARBOARD SIDE FORWARD.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Electrical
Issued 26 August 1987
Resolved
RENEW MISSING CIRCUIT BREAKER IN SERVING LINE PORTSIDE AFT.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Accommodation/Occupational Safety
Issued 29 May 1987
Resolved
PROVE PROPER OPERATION OF THE PORTSIDE EMERGENCY GENERATOR ROOM VENT LOUVERS.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
PROPERLY MARK THE GENERAL ALARM BATTERY DISCONNECT SWITCH.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
PROPERLY TERMINATE THE DEAD END CABLE IN THE ENGINE ROOM, PORT SIDE AFT.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Accommodation/Occupational Safety
Issued 29 May 1987
Resolved
RENEW TWO (2) MISSING VALVE HANDLES ON MSD.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Lifesaving
Issued 29 May 1987
Resolved
MAKE OPERABLE THE COOLING SYSTEM FOR THE #1 MLB ENGINE. THIS REQUIREMENT TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Accommodation/Occupational Safety
Issued 29 May 1987
Resolved
INSTALL A SHIELD ON THE #1 MSD VACCUM PUMP BELT.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Accommodation/Occupational Safety
Issued 29 May 1987
Resolved
REPAIR THE HANDLE FOR THE FIRE DAMPER ON THE STBD ENGINE ROOM AIR SUPPLY TRUNK, (1ST TRUNK FWD OF STBD M.E. STACK).
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Engineering
Issued 29 May 1987
Resolved
MAKE OPERABLE THE BILGE VALVE REACH ROD FOR THE FOREPEAK. A PORTABLE PUMP SHALL BE CARRIED AT ALL TIMES UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Construction/Loadline
Issued 29 May 1987
Resolved
REWELD THE CRACKED INTERMITTENT WELDS IN THE SIXTH FRAME, PORT SIDE, IN #3 VOID.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
RENEW THE ELECTRICAL CABLE FOR THE AFT BOAT DECK EMBARKATION LIGHT ON THE PORTSIDE.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Lifesaving
Issued 29 May 1987
Resolved
RENEW THE ROTTED FOOTER IN THE #2 LIFEBOAT, MIDSHIP PORTSIDE.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Lifesaving
Issued 29 May 1987
Resolved
REFASTEN THE PORT FWD AIR TANK IN THE #2 LIFEBOAT. THIS REQUIREMENT TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Engineering
Issued 29 May 1987
Resolved
MAKE BOTH BOILERS AVAILABLE FOR THE FOLLOWING: A) WATERSIDE EXAM; B) FIRESIDE EXAM; C) 1.25 MAWP HYDRO; D) OPERATIONAL TEST; AND E) OPEN MOUNTINGS.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Navigation
Issued 29 May 1987
Resolved
PROVE PROPER OPERATION OF THE MAIN STEERING GEAR BREAKER TRIPPED ALARM.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
PROVE PROPER OPERATION OF THE #2 GENERATOR HIGH WATER TEMPERATURE ALARM.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Lifesaving
Issued 27 February 1987
Resolved
MAKE #1 MOTOR LIFEBOAT AVAILABLE FOR WEIGHT TEST.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Electrical
Issued 27 February 1987
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE NO. 1 SHIPS SERVICE GENERATOR LOW LUBE OIL ALARM.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Accommodation/Occupational Safety
Issued 2 December 1986
Resolved
CONDUCT AN INVENTORY AND RESTOCK THE FIRST AID LOCKERS PRIOR TO PLACING THEVESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Fire Fighting
Issued 2 December 1986
Resolved
PROVIDE INSPECTION TAG FOR THE GALLEY HALON SYSTEM PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Accommodation/Occupational Safety
Issued 2 December 1986
Resolved
REMOVE THE KEROSENE FROM THE CREW'S QUARTERS. STORE IN PROPER METAL CONTAINERS PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Electrical
Issued 2 December 1986
Resolved
REHANG THE ELECTRICAL CABLES, PORT SIDE, UNDER BRIDGE WING PRIOR TO PLACINGTHE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Documentation
Issued 2 December 1986
Resolved
MAKE THE OIL TRANSFER PROCEDURES LEGIBLE PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Fire Fighting
Issued 2 December 1986
Resolved
CLEAN AND FLUSH OUT THE VESSEL'S FIRE MAIN AND CAR DECK SPRINKLER SYSTEMS AND DETERMINE THE CAUSE OF THE OIL CONTAMINATION TO THE SUBJECT SYSTEM. THE VESSEL IS TO BE PLACED OUT OF SERVICE UNTIL THE WORK IS COMPLETED TO THE SATISFACTION OF THE OFFICER IN CHARGE OF MARINE INSPECTION, PHILA.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Engineering
Issued 2 December 1986
Resolved
DEMONSTRATE THE BILGE SYSTEM TO THE SATISFACTION OF THE MARINE SAFETY INSPECTOR PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Accommodation/Occupational Safety
Issued 2 December 1986
Resolved
REHANG THE LOOSE AD SIGN IN THE SALON DECK PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Electrical
Issued 2 December 1986
Resolved
PROVIDE A CAP FOR THE STBD SIDE 440 VOLT SHOE RECEPTACLE PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 2 December 1986
Resolved 2 December 1986
Electrical
Issued 3 September 1986
Resolved
PROVIDE PLANS AND BILLS OF MATERIAL FOR COAST GUARD REVIEW FOR THE ADDITIONAL EMERGENCY LIGHTING SYSTEM THAT IS PRESENTLY BEING INSTALLED IN THE MACHINERY SPACE.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1986
Resolved
CONDUCT A FIRE AND BOAT DRILL WITH ACTUAL SHIP'S COMPLEMENT PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Construction/Loadline
Issued 3 September 1986
Resolved
DEMONSTRATE WATERTIGHT INTEGRITY OF THE AFT ENGINEROOM DOOR.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Construction/Loadline
Issued 3 September 1986
Resolved
DEMONSTRATE WATERTIGHT INTEGRITY OF BOTH SCUTTLES FOR THE STEERING GEAR FLAT.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986
Resolved
PLUG THE UNUSED KNOCKOUT IN THE ELECTRICAL JUNCTION BOX LOCATED IN THE ACCESSWAY TO THE BOW THRUSTER ROOM.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Accommodation/Occupational Safety
Issued 3 September 1986
Resolved
RENEW THE GOOSENECK VENT FOR #6 VOID, PORT SIDE.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986
Resolved
REWIRE IAW NEC THE CASH REGISTER POWER SUPPLY LOCATED IN WAY OF THE GALLEY SINK.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1986
Resolved
FREE UP THE SEA VALVE FOR THE MOTOR LIFEBOAT, DOUBLE CLAMP FLEXIBLE HOSE CONNECTION CLAMP.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1986
Resolved
RENEW DRAIN BALLS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1986
Resolved
PROVIDE A FLAME SCREEN OF 30/30 MESH AND VENT COVER FOR THE MOTOR LIFEBOAT.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Fire Fighting
Issued 30 May 1986
Resolved
PROVIDE OPERATING INSTRUCTIONS AT THE EMERGENCY GENERATOR FIXED CO2 SYSTEM CONTROL STATION.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Electrical
Issued 30 May 1986
Resolved
PROVIDE A PROPER FLAME SCREEN IN THE EMERGENCY GENERATOR FUEL TANK VENT.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Accommodation/Occupational Safety
Issued 30 May 1986
Resolved
PROPERLY INSTALL THE DECK PLATES IN THE ENGINE ROOM.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Navigation
Issued 30 May 1986
Resolved
GREASE FITTINGS IN AFTER STEERING.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Lifesaving
Issued 30 May 1986
Resolved
STRIP BOTH LIFEBOATS AND DEMONSTRATE THE TIGHTNESS OF THE BUOYANCY TANKS.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Lifesaving
Issued 30 May 1986
Resolved
REPLACE THE TWO RINGBUOYS LOCATED FORWARD PAST OF THE ACCOMMODATION DECK WITH BUOYS THAT HAVE GRAB LINES OF 4 TIMES THE OUTSIDE DIAMETER OF THE RINGBUOY.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Fire Fighting
Issued 30 May 1986
Resolved
PROVIDE ONE A-II FIRE EXTINGUISHER FOR THE PASSENGER DECK PORT SIDE AFT.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Fire Fighting
Issued 30 May 1986
Resolved
PROVIDE APPROVED BII FIRE EXTINGUISHERS FOR THE GALLEY (ONE) AND VEHICLE DECK (TWO).
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Construction/Loadline
Issued 30 May 1986
Resolved
DEMONSTRATE WATERTIGHT INTEGRITY OF ALL SCUTTLES AND WATERTIGHT DOORS.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Electrical
Issued 30 May 1986
Resolved
PROVIDE A PROPER MARINE ELECTRICAL INSTALLATION FOR THE HEATING TAPE FOR THE TOILET FLUSHING SYSTEM.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Engineering
Issued 30 May 1986
Resolved
MAKE #1 AUX. BOILER AVAILABLE FOR WATERSIDE EXAMINATION.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Engineering
Issued 30 May 1986
Resolved
MAKE REPAIRS TO #1 AUX. BOILER BRICK WORK AND MAKE BOILER AVAILABLE FOR FIRESIDE EXAMINATION.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Engineering
Issued 30 May 1986
Resolved
MAKE REPAIRS TO #1 AUX. BOILER HAND HOLES AND MAKE BOILER AVAILABLE FOR 1.25 X MAWP HYDROSTATIC TEST.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Engineering
Issued 30 May 1986
Resolved
MAKE BOTH AUX BOILERS AVAILABLE FOR OPERATIONAL TEST.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Engineering
Issued 30 May 1986
Resolved
PERFORM SATISFACTORY TEST OF BOTH AUX BOILER REMOTE SHUT DOWNS.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Navigation
Issued 30 May 1986
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE POWER FAILURE ALARM FOR THE AUX STEERING SYSTEM.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Electrical
Issued 30 May 1986
Resolved
PROVIDE WIRING DIAGRAMS IN MOTOR CONTROLLERS IN THE ENGINE ROOM AS NECESSARY.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Electrical
Issued 30 May 1986
Resolved
STENCIL THE REMOTE FUEL SHUT OFF VALVE FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Navigation
Issued 10 January 1986
Resolved
REMOVE PAINT AND PROPERLY GREASE STEERING TILLER BAR BUSHING.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Engineering
Issued 10 January 1986
Resolved
RENEW FLAME SIGHT GLASS ON TOP OF #1 BOILER TO FIT RECESSED AREA PROPERLY.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Electrical
Issued 10 January 1986
Resolved
FIT PROPERLY THE ELECTRICAL CONDUIT ON TOP OF #1 BOILER.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Accommodation/Occupational Safety
Issued 10 January 1986
Resolved
RENEW RELIEF VALVE ON SANITARY TANK AND PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Engineering
Issued 10 January 1986
Resolved
FIND AND REPAIR SOURCE OF SOOT LEAKAGE ON #1 BOILER.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Engineering
Issued 10 January 1986
Resolved
MAKE NECESSARY REPAIR TO PREVENT AIR LEAKAGE IN AIR RECEIVER MANIFOLD LINE.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986
Fire Fighting
Issued 18 October 1985
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE AUTOMATIC VENT DAMPERS IN THE EMERGENCY GEN. ROOM.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Electrical
Issued 18 October 1985
Resolved
INSTALL IN PANEL P-15 A CIRCUIT BREAKER OR A BLANK TO COVER THE HOLE IN THEDEAD FRONT COVER.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Engineering
Issued 18 October 1985
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE FORE PEAK BILGE VALVE REMOTE OPERATOR.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Fire Fighting
Issued 28 August 1985
Resolved
PROVIDE COMPLETE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM AT PORT ENGINEROOM ENTRANCE.
Condition: Unknown
Due 28 August 1985
Resolved 28 August 1985
Electrical
Issued 28 August 1985
Resolved
REPAIR OR REPLACE #2 S/S GEN TACHOMETER.
Condition: Unknown
Due 28 August 1985
Resolved 28 August 1985
Electrical
Issued 28 August 1985
Resolved
REPAIR OR REPLACE HORN FOR EMER. GEN. LUBE OIL ALARM.
Condition: Unknown
Due 28 August 1985
Resolved 28 August 1985
Accommodation/Occupational Safety
Issued 28 August 1985
Resolved
RENEW MOUNTING NUT BOLT & WASHER AT TOP RUNG STBD. SIDE OF LADDER INTO AFTER PEAK.
Condition: Unknown
Due 28 August 1985
Resolved 28 August 1985
Accommodation/Occupational Safety
Issued 28 August 1985
Resolved
RENEW VENTILATION FIRE DAMPER HAND CLOSURE ON AFTER AIR SUPPLY DUCT STBD. SIDE.
Condition: Unknown
Due 28 August 1985
Resolved 28 August 1985
Deck/Cargo
Issued 25 June 1985
Resolved
INSTALL SOUNDING TUBES IN OUTBOARD BILGE POCKETS OF VOID UNDER STEERING ENGINE VOID, AND PERMANENTLY OPEN STEERING ENGINE VOID DRAINS TO VOID UNDERIT. INSTALLATION TO BE COMPLETED BY NEXT D/D. (46 CFR 56.50-90)
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Construction/Loadline
Issued 30 May 1985
Resolved
SAFEEND, GOUGE OUT AND REWELD FRACTURE IN COLLISION BULKHEAD AT INVERTED CHINE ON PORT SIDE.
Condition: Unknown
Due 30 May 1985
Resolved 30 May 1985