C-TRUC 9 is a 1998 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2016, most recently in December 2025, along with 20 deficiencies, 2 operational controls and 3 casualty investigations between 2010 and 2021.
Records from 2010 to 2025. Most recent: inspection, 19 December 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)186.7 ft × 46.0 ft × 17.0 ft
Registered tonnagegross 1,171 / net 351
ITC dimensions (L × B × D)186.7 ft × 46.0 ft × 17.0 ft
ITC tonnagegross 1,171 / net 351
BuilderHALTER MARINE GROUP INC · MOSS POINT, MS, UNITED STATES · built 1998
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1171 - Convention (Subpart B), Gross Ton 351 - Convention (Subpart B), Net Ton 1758 - Dead Weight, Ton 913 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 February 2025Resolved
Nothing in this part shall limit the inspector from making tests to assure the safety and seaworthiness of the vessel. Attending technician administered function tests of fixed C02 system for the bow thruster & machinery spaces. A tubing connection was found with a small leak after testing the thruster space. The tubing connection was replaced.
Initial function tests of the machinery space failed. Nozzles covered with foil did not clear. Troubleshooting found a nipple to the siren was cracked. The nipple was replaced, system retested, and all nozzles cleared. Technician issued a report attesting to the system being 100 percent operational upon departure.
46 CFR 126.100
Action required: 10 - Deficiency Rectified
Due 12 February 2025
Resolved 12 February 2025
Resolution: Tubing connector and siren nipple replaced. Technician issued a report attesting to the system being 100 percent operational upon departure. Report attached deficiency documents tab.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2025Resolved
Class – 1 door may be installed at any place if the vessel’s pilothouse contains a visual indicator showing whether the hatch is open or closed. Port and Stbd machinery escape hatch indicators were not showing proper indication when in the closed position (no contact). The indicator arms were adjusted and satisfactory operation verified.
46 CFR 174.210(c)(3)
Action required: 10 - Deficiency Rectified
Due 12 February 2025
Resolved 12 February 2025
Resolution: The indicator arms were adjusted and satisfactory operation verified.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2025Resolved
Each refrigerated space that is accessible to the vessel's personnel and that can be locked from the outside so that it cannot be opened from the inside, must have an audible alarm system that can be operated from within the refrigerated space. Vessel had walk in refrigerated spaces that were lockable and did not have audible alarms. The mechanisms that allowed the spaces to be locked were removed at attendance.
46 CFR 113.45-5
Action required: 10 - Deficiency Rectified
Due 12 February 2025
Resolved 12 February 2025
Resolution: The mechanisms that allowed the spaces to be locked were removed at attendance.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 16 November 2022Resolved
For each vessel of 100 or more gross tons, the bulkheads and decks separating accommodations for crew members and offshore workers from machinery spaces must be of “A” Class construction as defined by § 92.07-5 of this chapter.
Ventilation trunk in berthing area is severely corroded and had multiple holes in it, allowing air/gases fro engine room into the living quarters.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
Compliance with the construction and structural rules established by the American Bureau of Shipping and incorporated by reference in § 125.180 is acceptable for the design and construction of an OSV.
There were two holes in the deck, first going into the engine room above the stbd mde, and the second in between the first and second mud tank stbd side
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 November 2022Resolved
Except as provided in paragraph (c) of this section, OSVs must carry one or more liferafts with an aggregate capacity that will accommodate the total number of persons on board. Additional liferafts must be provided to bring the total capacity available on each side
to at least 100 percent of the total number of persons on board
COI endorses 16 personnel however the port side life raft was for 10 persons and the stbd life raft was for
12 persons. Vessel did not have 100% capacity on each side.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 November 2022Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition. The owner or builder shall make the vessel and its equipment available for inspection, including potential fire hazards.
Oil sight glasses on both port and stbd side in
engine room were dripping onto electrical panels.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 November 2022Resolved
Each OSV must carry a rescue boat or as an alternative, a motor propelled workboat. The vessel's workboat sponson was being held together with duct tape. Vessel
must have a serviceable rescue boat or as an equivalent,
a work boat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2022Resolved
The cognizant OCMI will review the particular installation of each system for the safety hazards.
Port MDE exhaust piping had multiple holes and exhaust
leaks
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 November 2022Resolved
Each vessel must meet the applicable requirements in sub chapter S of this chapter.
Forward collision bulkhead reach rod was unable to move.
Vessel must demonstrate operation of reach rod.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 November 2022Resolved
Each alarm of this subpart must be of the self-monitoring type that will both show visibly and sound audibly upon an opening or break in the sensing circuit.The audible alarm must sound until it is manually silenced. The vessel was unable to silence the alarms and had to remove the backup battery and trip the breaker in order to silence the alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 16 November 2022Resolved
Each enclosed space within the vessel must be properly vented or ventilated. Means must be provided for closing each vent and ventilator. Multiple vents on the main deck were missing a means of closing properly and had damaged or missing gaskets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 November 2022Resolved
Each valve must close with a right (clockwise) motion of the handwheel or operating lever. Lubricating oil valve did not have a handwheel or operating lever and pliers were affixed to the stem.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 30 November 2022
Resolution: Marine inspector re-attended the vessel and verified the deficiency was rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 November 2021Resolved
On vessels required to have a final emergency power source by § 112.05-5(a) of this chapter, the following emergency lighting and power loads must be arranged so that they can be energized from the final emergency power source: (a) Each load under § 112.15-1. Lighting...for passageways, stairways, and escape trunks in passenger quarters, crew quarters, public spaces, machinery spaces...sufficient to allow passengers and crew to find their way to open decks and to survival craft, muster stations, and embarkation stations with all watertight doors and fire doors closed. The emergency lighting for the port side engine room escape hatch and main deck escape trunk were inoperable at time of inspection. Vessel shall make lighting operable prior to departure to the satisfaction of the MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2021
Resolution: Vessel provided evidence of proper operation of emergency lighting.
The master of each vessel shall ensure that the emergency lighting and power systems are tested at least once each week that the vessel is operated, to verify that they work. The date of each test and the condition and performance of the apparatus must be noted in the vessel's logbook. The vessel could not provide evidence that weekly checks of emergency lighting were being performed. Vessel shall ensure weekly checks are incorporated into the vessels maintenance program to the satisfaction of the MI within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 November 2021
Resolution: Vessel provided evidence of addition of e-lighting to weekly checks.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 November 2021Resolved
Each fire pump must be capable of providing the quantity of water required to comply with paragraph (a) of this section while meeting any other demands placed on it, as by a branch line connected to the fire main for washing the anchor or the deck. Vessels fire pump was inoperable at time of inspection. Vessel shall make fire pump operable prior to departure to the satisfaction of the MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2021
Resolution: Vessel replaced fire pump and provided evidence of proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 June 2021Resolved
Repairs or alterations must be inspected by the marine inspector. Vsl sustained damage, 3-4 inch hole in # 3 stbd wing tank after making contact with offshore platform. Vsl is proceeding to Bollinger shipyard in Morgan City LA for drydock, where damage survey and repairs will take place. Repairs shall be made to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 June 2021
Resolved 12 June 2021
Resolution: Vsl made effective repairs to the fuel tank by conducting a cut-out and insert to the punctured fuel tank.
Before any vsl leave protected waters, the master shall ensure that the vsl's exposed cargo hatches & other opening in the hull are closed; ase properly watertight by the use of gaskets and properly secured for sea. the following doors were found to not be water/weather tight: 1) fixed CO2 compartment door 2) 1 level starboard door 3) port/starboard E/R escape hatches
doors shall be watertight/weathertight before departure
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 September 2020
Resolved 28 September 2020
Resolution: Corrected prior to completion of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 September 2020Resolved
Scope of annual inspection for vsl safety and seaworthy condition shall include inspection of main/aux machinary & piping. MI noted two (02) washted air hosed on part generator stater.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 September 2020
Resolution: Received pictures of new hoses installed onboard.
Owner or operator shall make the vessel available for inspection whenever any important repairs or renewal are made. Vessel suffered hull damage due to an allision. Bow pushed in approximately 8 to 10 feet crumpling and breaching the fwd deck IWO chain locker. Foremast is bent backwards with additional damage to 01 deck handrails. Foremast head light is broken. Make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2020
Resolved 18 February 2020
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
K-MARINE VI (2010–2021). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.