Inspection history · 77
18 March 2026
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8328248
1 October 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8244742
20 August 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8214590
24 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8118746
12 March 2024
Internal Structural Exam · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7877970
9 November 2022
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7584351
22 March 2022
COI Inspection · Construction Oversight · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7435135
30 March 2021
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158058
5 August 2020
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7024442
9 July 2020
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7002423
13 February 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950562
10 February 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6906546
6 February 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6620909
9 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6369154
12 January 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6504452
5 April 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6107997
21 November 2016
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6045559
31 March 2016
Internal Structural Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5844378
23 February 2015
MARPOL Annex I Examination · Load Line/Change of Employment · MARPOL Annex VI Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5073345
4 August 2014
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4943628
4 June 2013
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4610815
17 May 2012
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4313856
5 July 2011
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4069222
30 April 2010
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3727009
18 May 2009
Drydock Exam · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3477849
4 June 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227468
21 April 2008
Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3186905
15 May 2007
Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2925094
9 July 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2756008
8 March 2006
COI Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2598863
27 April 2005
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2343875
12 October 2004
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2218699
8 October 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2223770
19 April 2004
Internal Structural Exam · Hull Examination · Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2047721
7 April 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1769389
24 May 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1620550
19 April 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1610863
8 June 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 773203
24 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065695
18 April 2001
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466210
24 August 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 823855
21 July 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427859
26 August 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401071
9 November 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 803658
16 July 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1428986
31 December 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 114257
13 June 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469821
13 August 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089108
5 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394194
24 July 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1359243
17 July 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 674115
2 July 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 393149
15 August 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 173485
5 July 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383045
23 March 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 119771
8 July 1994
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172087
6 May 1994
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181462
14 February 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163232
7 February 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 504117
8 January 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 83149
31 August 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146655
22 July 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943021
21 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1262461
19 July 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245656
27 July 1990
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1240536
16 March 1990
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 923083
25 October 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 449567
22 August 1989
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 887925
26 July 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 492608
4 May 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 467796
29 December 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1038874
10 November 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 326834
18 August 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1344760
12 May 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195984
8 February 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1020342
10 June 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1028831
13 August 1986
COI Inspection · Credit Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999647
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 2 September 2025
Resolved
Vessel's International Load Line Certificate (ILLC) is expired. Receive a new ILLC from Class.
Cites: 46 CFR 92.01-5, 46 CFR 42.03.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 September 2025
Resolved
Vessel's lifejacket lights were expired. Replace the expired lifejacket lights.
Cites: 46 CFR 90.27-1, 46 CFR 199.70(b)(4)(i).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2025
Resolution: Rcvd invoice for new lifejacket lights
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 August 2025
Resolved
Complete annual inspection with USCG marine inspectors prior to movement.
Cite: 46 CFR 91.27-1.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 September 2025
Resolution: Annual Inspection completed this date.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 March 2024
Resolved
Observed Aft Port side void with wasted steel and an inset both located at the most forward frame, adjacent to the ladder. Crop and renew of similar metal at the location of the inset and wasted steel. Repairs are to be completed at next dry dock.
Action required: 705 - Other - as specified
Resolved 25 June 2025
Resolution: Repairs completed at Drydock
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2020
Resolved
Vessels in ocean, coastwise, or Great Lakes service, except unmanned barges, shall be fitted with anchors, chains, and hawsers in general agreement with the standards established by ABS. Port quarter double cross bitts were wasted on the bottom of the horizontal cross portion. Make permanent repairs to bitts.
46 CFR 96.07-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2020
Resolved 28 July 2020
Resolution: Received photo of repaired bitts.
Deck/Cargo › Ballast › Pumps
Issued 21 April 2008
Resolved
Make area under prime mover ready for inspectio and prove operation of Ballast Pump and prime mover IAW REF 91.27-1.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2008
Resolved 28 April 2008
Resolution: Area under prime mover was ready for inspection and proved operation of Ballast Pump and prime mover.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 21 April 2008
Resolved
Make draft and vessels name contrasting in color to hull IAW REF 46CFR97.40-10.
Due 21 May 2008
Resolved 31 May 2008
Resolution: Examined draft markings and vessel''s name and found satisfactory.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 21 April 2008
Resolved
Provide Ballast Water Managament Plan for review IAW NVIC 07-04 ch 1.
Due 21 May 2008
Resolved 4 June 2008
Resolution: Ballast Water Management Plan reviewed by Sector Mobile IAW 33 CFR 151, Subpart D and Navigation and Vessel Inspection Circular 07-04, Change 1. Plan returned and marked "Examined."
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 21 April 2008
Resolved
Provide Tier II documentation of Prime Mover IAW MARPOL ANNEX 6.
Due 30 May 2008
Resolved 28 April 2008
Resolution: Tier II documentation of Prime Mover provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 April 2008
Resolved
Remove dirt and debris from the top of the battery IAW 91.27-1.
Due 30 May 2008
Resolved 30 May 2008
Resolution: Dirt and debris removed from the top of the battery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 April 2008
Resolved
Properly secure the battery box lid IAW 11.15-5.
Provide support for wiring from battery to the prime mover; every 2 ft IAW 91.27-1.
Due 30 May 2008
Resolved 30 May 2008
Resolution: Battery box lid properly secured and wiring from battery to the prime mover supported.
Engineering › Bilge Water Management System › Valve
Issued 21 April 2008
Resolved
Provide plug for pump inlet bleeder valve IAW 56.01-1.
Due 30 May 2008
Resolved 30 May 2008
Resolution: Plug for pump inlet bleeder valve provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 April 2008
Resolved
Replace fire extinguisher bracket in way of prime mover IAW 97.15-60.
Due 30 May 2008
Resolved 30 May 2008
Resolution: Fire extinguisher bracket in way of prime mover replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 May 2007
Resolved
Replace both ladders entering into the pumproom.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 July 2007
Resolution: Replaced both ladders.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2007
Resolved
Label emergency fuel shut-off.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 July 2007
Resolution: Labeled emergency fuel shut-off.
Stability › Watertight Integrity › General
Issued 15 May 2007
Resolved
Provide plug for the ballast discharge bleeder valve and for the fuel sounding valves.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 July 2007
Resolution: Prvided plugs for ballast and fuel oil.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 15 May 2007
Resolved
Provide current load line document.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 July 2007
Resolution: Provided current load line document.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 May 2007
Resolved
Paint draft marks.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 July 2007
Resolution: Painted draft marks.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 6 April 2006
Resolved
Conduct structural repairs to vessel as noted on worklist issued during course of inspection as noted in the narrative portion of this activity on 06 April 2006.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 20 April 2006
Resolution: All deficiencies noted during Internal Structure Examination have been completed to the satisfaction of the attending marine inspector.
Documentation › Markings/Placards › Warning Signs
Issued 27 April 2005
Resolved
Properly label emergency fuel shut off for ballast pump prime mover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 April 2005
Resolved
Crop & renew entire stair way ( step) in ballast room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 20 May 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 April 2005
Resolved
Provide and install lagging on ballast pump prime mover exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2005
Resolved
Provide and install guards over alternator on ballast pump prime mover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 20 May 2005
Deck/Cargo › Ballast › Piping
Issued 27 April 2005
Resolved
Make repairs to leak in ballast pump discharge line in ballast pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 20 May 2005
Engineering › Fuel Oil Service System
Issued 7 April 2003
Resolved
Replace missing closure device on diesel fuel oil tank vent pipe as per 46 CFR 56.50-85 (7). LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 May 2003
Resolved 7 April 2003
Resolution: Replace missing closure device on diesel fuel oil tank vent pipe as per 46 CFR 56.50-85 (7) with a new hinged closure device.
Stability › Watertight Integrity
Issued 19 April 2002
Resolved
Adjust all dogs on watertight hatches such that the dogs are free to move. Ensure dogs are securely fastened to the vessel. Found Found dogs on 1S & 1P with wasted clips. LEGACY COMPONENT DESC: Hatches
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2002
Resolved 19 April 2002
Resolution: Inspected all hatches. Dogs are all greased and able to move.
Stability › Watertight Integrity
Issued 19 April 2002
Resolved
Adjust gasket on center forward hatch leading to forward rake. Gasket is falling out of the hatch. LEGACY COMPONENT DESC: Gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2002
Resolved 19 April 2002
Resolution: Inspected gasket. Gasket is adequately affixed to the hatch.
Deck/Cargo › Towing
Issued 19 April 2002
Resolved
Adjust emergency towing messenger wire mounted on the starboard aft deck board as necessary such that the wire is free to move. The wire is rusted in place. LEGACY COMPONENT DESC: Towline
Due 31 May 2002
Resolved 24 May 2002
Resolution: Emergency towing messenger wire was replaced and remounted.
Construction/Loadline › Hull
Issued 19 April 2002
Resolved
Repair/renew as needed hole in the starboard skeg, outboard along weld seam. LEGACY COMPONENT DESC: Skeg
Due 19 May 2002
Resolved 24 May 2002
Resolution: Hole in starboard skeg was cropped out and renewed. Repair satisfactory.
Construction/Loadline › Structures
Issued 19 April 2002
Resolved
Replace bracket securing the forward ventilation trunk located in the ballast pump room. The bracket have completely wasted away. LEGACY COMPONENT DESC: Trunk
Due 19 May 2002
Resolved 24 May 2002
Resolution: Brackets were replaced and are satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 April 2002
Resolved
Renew fire-extinguishing bracket at the bottom of the aft entrance to the ballast pump room such that the bracket can be easily operated to remove fire extinguisher. Bracket cannot be opened without mechanical means. LEGACY COMPONENT DESC: Mounting Bracket
Due 3 May 2002
Resolved 24 May 2002
Resolution: Brackets are well greased and operational
Electrical › Electric Supply System (service)
Issued 19 April 2002
Resolved
Install wood strips battery boxes located in ballst pump room and all three on main deck to prevent movement of batteries. LEGACY COMPONENT DESC: Battery Installation
Due 19 May 2002
Resolved 24 May 2002
Resolution: Wood strips installed in battery boxes.
Electrical › Electric Supply System (service)
Issued 19 April 2002
Resolved
Replace liners in all abattery boxes per 46 CFR 111.15-10(g). Current liners are insufficient to protect battery boxes from corrosion. LEGACY COMPONENT DESC: Battery Installation
Due 19 May 2002
Resolved 24 May 2002
Resolution: Liners have been replaced.
Electrical › Electric Supply System (service)
Issued 19 April 2002
Resolved
Replace/renew wires as necessary for solar panels leading to battery such that connections/splices are watertight. Add lock washers to wing nuts on batteries or replace with nylon-threaded nuts. LEGACY COMPONENT DESC: Battery Installation
Due 19 May 2002
Resolved 24 May 2002
Resolution: Connections inspected and found satisfactory.
Deck/Cargo › Ballast
Issued 19 April 2002
Resolved
Remove hose from ballast pump used to remove water from the ballast pump room
Due 3 May 2002
Resolved 24 May 2002
Resolution: Hose removed from ballast pump.
Engineering › Fuel Oil Service System
Issued 19 April 2002
Resolved
Provide shut off valves for fuel oil system near pump engine. 46 CFR 56.50-75(a)(4) LEGACY COMPONENT DESC: Valve
Due 19 May 2002
Resolved 24 May 2002
Resolution: Shut off valve installed on fuel oil pipes.
Engineering › Fuel Oil Service System
Issued 19 April 2002
Resolved
Provide non-metallic hoses for fuel supply system in accordance with 46CFR56.60-25(b). Hoses must be approved with "SAE J-1942". Fittings for hoses must be approved "SAE J-1475" per 46 CFR 56.60-25(b)(5). LEGACY COMPONENT DESC: Hose
Due 19 May 2002
Resolved 24 May 2002
Resolution: Non-metallic hoses inspected and found satisfactory.
Electrical › Electrical Distribution System (service)
Issued 19 April 2002
Resolved
Remove dead end cables and wires in ballast pump room and on engine. Found dead end cables on battery box, on the vertical stanchion inboard and aft of the ballast pump, and on the engine. LEGACY COMPONENT DESC: Wiring
Due 19 May 2002
Resolved 24 May 2002
Resolution: Dead end cables removed.
Engineering › Fuel Oil Service System
Issued 19 April 2002
Resolved
Secure stainless steel fuel supply pipe to prevent excess movement. LEGACY COMPONENT DESC: Piping
Due 19 May 2002
Resolved 24 May 2002
Resolution: Brackets where installed to hold supply pipe
Engineering › Fuel Oil Storage/Transfer System
Issued 19 April 2002
Resolved
All fitting for pipe connections on the diesel oil fuel tank must be brazed or welded to the tank. There can be no opening in the bottom, top, or sides of the tank except for the fuel supply piping, a threaded opening for tank cleaning, and liquid gauging. 46 CFR 58.50-10(a)(4) LEGACY COMPONENT DESC: Tank
Due 19 May 2002
Resolved 24 May 2002
Resolution: Diesel fuel oil tank fittings are satisfactory.
Engineering › Fuel Oil Service System
Issued 19 April 2002
Resolved
Provide a means to close the fuel supply valve located near the tank from a remote, readily accessible locatoin outside the space. LEGACY COMPONENT DESC: Valve
Due 19 May 2002
Resolved 24 May 2002
Resolution: Fuel supply shutoff valve installed and found to be satifactory.
Engineering › Diesel Engine (auxiliary)
Issued 19 April 2002
Resolved
Mount the wire for the alternator on the ballast pump engine such that it is not sitting in the retaining sump below the engine. 46 CFR 91.27-10 LEGACY COMPONENT DESC: Wiring
Due 3 May 2002
Resolved 24 May 2002
Resolution: Wire was removed from the retaining sump and mounted to prevent from falling into sump.
Electrical
Issued 18 April 2001
Resolved
REMOVE DEAD END CABLES AT BALLAST PUMP ENGINE.
Condition: Unknown
Due 8 June 2001
Resolved 12 December 2001
Deck/Cargo
Issued 18 April 2001
Resolved
REMOVE INOPERATIVE (OBSOLETE) PRESSURE/VACUUM GAUGES.
Condition: Unknown
Due 8 June 2001
Resolved 12 December 2001
Navigation
Issued 18 April 2001
Resolved
REPAINT NAV LIGHT SHIELDS IAW W/ COLREGS (MATTE/FLAT BLACK).
Condition: Unknown
Due 8 June 2001
Resolved 12 December 2001
Navigation
Issued 18 April 2001
Resolved
REPAINT TOWING DAYSHAPE MATTE/FLAT BLACK.
Condition: Unknown
Due 8 June 2001
Resolved 12 December 2001
Electrical
Issued 18 April 2001
Resolved
REMOVE OBSOLETE LIGHT SWITCH NEAR BALLAST PUMP ENGINE.
Condition: Unknown
Due 8 June 2001
Resolved 12 December 2001
Construction/Loadline › Structures
Issued 18 April 2001
Resolved
Gouge and reweld those fractured welds noted in the following tanks: #5S, #4S, #3S,#1S, #1P, #6P, and #2P
Action required: 705 - Other - as specified
Due 18 April 2001
Resolved 18 April 2001
Resolution: All repairs were examined and found satisfactory
Deck/Cargo › Holds/Tanks › Coaming
Issued 18 April 2001
Resolved
Renew hatch coamings and gaskets to all void /ballast tank openings.
Action required: 705 - Other - as specified
Due 18 April 2001
Resolved 18 April 2001
Resolution: Examined and found satisfactory repair of tank opening coamings and renewal of gaskets. All tank openings were proven watertight upon completion of repairs and/or renewal.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 April 2001
Resolved
Conduct gaugings to the following suspect transverse bulkheads: #5S tank aft centerline bulkhead in way of bottom shell connection and #1P tank behind entrance ladder in way of side shell connection.
Action required: 705 - Other - as specified
Due 18 April 2001
Resolved 18 April 2001
Resolution: All suspected areas were gauged and found satisfactory. Gauging report was submitted and reviewed. All gauge readings were within acceptable corrosion allowances. Gauging report was placed in vessel file.
Construction/Loadline
Issued 21 July 2000
Resolved
REPAIR OR REPLACE THE HATCH COVERS TO THE FOLLOWING VOIDS: #2 STBD AFT, #5 STBD AFT, #6 STBD FWD AND AFT, #4 PORT AFT, #2 PORT FWD AND AFT, #5 PORT FWD.
Condition: Unknown
Due 21 August 2000
Resolved 28 August 2000
Construction/Loadline
Issued 26 August 1999
Resolved
REPAINT DECK REFERENCE LINE.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Construction/Loadline
Issued 26 August 1999
Resolved
SECURE ALL LOOSE HATCH GASKETS.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Construction/Loadline
Issued 26 August 1999
Resolved
REPAIR AND SATISFACTORILY CHALK TEST #5 STARBOARD VOID TANK HATCH.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL TO HAUL OUT, DRYDOCK AND NOTIFY THE OCMI MOBILE, ALABAMA TO CONDUCT CREDIT DRYDOCK EXAMINATION IAW 46 CFR 91.40(C).
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Navigation
Issued 13 June 1997
Resolved
PAINT THE VESSEL'S NAVIGATIONAL SIDELIGHT SCREENS WITH A MAT BLACK COLOR IAW 33 CFR 84.09(A).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Accommodation/Occupational Safety
Issued 13 June 1997
Resolved
RENEW/REPAIR THE DETERIORATED GUARD RAILS THROUGHOUT THE VESSEL'S WEATHER DECK IAW 46 CFR 42.15-75(B)(1)&(C).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Engineering
Issued 13 June 1997
Resolved
PERFORM A HYDROSTATIC TEST ON THE VESSEL'S FUEL TANK IN WAY OF THE BALLAST PUMP ROOM AS PER 46 CFR 50.20-35.
Condition: Unknown
Due 13 June 1997
Resolved 1 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL TO PERFORM STRUCTURAL AND FRACTURE SURVEY OF ALL INTERNAL SPACES ANDPROVIDE A REPAIR PROPOSAL TO THE OCMI MOBILE, ALABAMA.
Condition: Unknown
Due 13 June 1997
Resolved 1 July 1997
Documentation
Issued 13 June 1997
Resolved
VESSEL TO NOTIFY COAST GUARD MSO MOBILE TO COMPLETE INTERAL STRUCTURAL EXAMINATION IN THE #6 PORT AND STARBOARD BALLAST TANKS UPON ARRIVAL TO PORTOF MOBILE, ALABAMA AND IN NO CASE LATER THAN 11MAR97 AS PER 46 CFR 91.40- 3(A)(1).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL TO REPAIR OR REPLACE AS NEEDED WEATHER DECK HATCH COVERS TO ENSURE AWEATHERTIGHT SEAL IN ALL SEA CONDITIONS AS PER 46 CFR 42.15-30(C).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Electrical
Issued 13 June 1997
Resolved
RENEW/REPAIR THE DETERIORATED BATTERY BOXES THROUGHOUT THE VESSEL. ENSURE ALL BOXES ARE PROPERLY LINED WITH A WATERTIGHT LEAD PAN, VENTED AND IS WEATHERTIGHT TO PREVENT ENTRANCE OF SPRAY OR RAIN IAW 46 CFR 111.15-10(D).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL TO HAVE INSTALLED NON-METALLIC FLEXIBLE HOSE IN BALLAST PUMP SALT WATER SUPPLY LINE AS PER 46 CFR 56.60-25 (C)(3).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL IS REQUIRED TO REMOVE WAFER TYPE VALVES FROM SEA CHEST CONNECTION AND REPLACE WITH AN APPROVED TYPE VALVE IAW ABS RULES.
Condition: Unknown
Due 13 June 1997
Resolved 1 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
VESSEL TO HAVE INSTALLED VENTILATORS TO BALLAST PUMP ROOM A MINIMUM OF 30" ABOVE DECK AND SHALL HAVE SUITABLE WEATHERTIGHT COVERS PERMANANTLY ATTACHEDAS PER 46 CFR 42.15-45(D).
Condition: Unknown
Due 13 June 1997
Resolved 1 July 1997
Electrical
Issued 13 June 1997
Resolved
PROVIDE PROTECTION COVERS TO ALL EXPOSED ELECTRICAL WIRING ON THE BALLAST PUMP ENGINE AND FOR THE BATTERY DISCONNET SWITCH TO THE ENGINE IAW 46 CFR 111.05.-15.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE A SAFETY COVER TO THE EXPOSED MOVING PARTS ON THE BALLAST PUMP PRIME MOVER IAW 46 CFR 58.01-20.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Unknown
Issued 24 July 1996
Resolved
REPLACE OR REPAIR ALL HATCH DOG EARS AND FREE MOVEMENT ON HATCHES THRU OUT VESSEL.
Condition: Unknown
Due 15 August 1996
Resolved 28 August 1996
Navigation
Issued 24 July 1996
Resolved
REPLACE OR CLEAN STERN LIGHT LENS COVER.
Condition: Unknown
Due 15 August 1996
Resolved 28 August 1996
Unknown
Issued 24 July 1996
Resolved
REPAIR HAND RAIL ON PORT AFT RAIL TO DECK.
Condition: Unknown
Due 15 August 1996
Resolved 28 August 1996
Unknown
Issued 24 July 1996
Resolved
REPLACE OR REPAIR STEPS GOING DOWN TO BILGE PUMP ROOM. ALSO REPAIR DECK GRADING IN WALK WAY IN PUMP ROOM.
Condition: Unknown
Due 15 August 1996
Resolved 28 August 1996
Navigation
Issued 24 July 1996
Resolved
PAINT PORT NAV. LIGHT SHIELD GUARDS. FLAT BLACK.
Condition: Unknown
Due 15 August 1996
Resolved 28 August 1996
Documentation
Issued 2 July 1996
Resolved
SPECIFIC CITE: 49 C.F.R. 176.30(B) THE DCM WAS MISSING THE PREPARERS STATEMENT, DATING AND SIGNITURE CERTIFYING THAT THE INFO WAS ACCURATE TO THE BEST OF HIS/HER KNOWLEDGE._x001C_ _x001C_
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Documentation
Issued 2 July 1996
Resolved
SPECIFIC CITE: 49 C.F.R. 176.30(A)(3) IDENTIFICATION # LISTED FOR (4) RAILCARS CARRYING HAZARDOUS WASTE (UN1993) WAS INCORRECT. (UN1993) IS THE I.D.# FOR FLAMM LIQ N.O.S._x001C_ _x001C_
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Documentation
Issued 2 July 1996
Resolved
SPECIFIC CITE: 49 C.F.R. 176.30(A)(3) EMERGENCY #'S LISTED WERE INVALID. DCM USED CHEMTRECS 1-[phone withheld] #. EMERGENCY RESPONDERS CALLED CHEMTREC FOR FIRST RESPONSE INFORMATION. CHEMTREC STATED THEY HAD NO CONTRACT W/ COMPANY TO PROVIDE SUCH INFO.
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Documentation
Issued 2 July 1996
Resolved
SPECIFIC CITE: 49 C.F.R. 176.30(A)(3) DCM LIST (6) RAILCARS CARRYING BULK HAZMAT W/ THE IMPROPER SHIPPING NAMES. (4) READ HAZARDOUS WASTE VICE_x001C_ HAZARDOUS WASTE LIQ, N.O.S., (1) READ HYDROCHLORIC ACID, VICE HYDROCHLORIC ACID, SOLUTION, (1) READ METHYLENE CHLORIDE VICE DICHLORO METHANOL.
Condition: Unknown
Due 12 August 1996
Resolved 12 August 1996
Construction/Loadline
Issued 8 July 1994
Resolved
DEMONSTRATE OPERATION OF BALLAST PUMP ENGINE, REMOVE EXTRA ELECTRICAL STARTBATTERY FROM INBOARD OF ENGINE.
Condition: Unknown
Due 15 July 1994
Resolved 20 July 1994
Construction/Loadline
Issued 8 July 1994
Resolved
REPAIR OR RENEW STBD AFTER 4" BALLAST VENT, WASTED AT THE THRU HULL PIPING/DECK CONNECTION. IF RENEWED MINIMUM HEIGHT OF 30" REQUIRED.
Condition: Unknown
Due 15 July 1994
Resolved 20 July 1994
Construction/Loadline
Issued 8 July 1994
Resolved
MARK VESSELS NAME AND HAILING PORT ON STERN.
Condition: Unknown
Due 15 July 1994
Resolved 20 July 1994
Navigation
Issued 8 July 1994
Resolved
RENEW STERN LIGHT LENSES (WATERTIGHT) AND REPLACE ACTIVATION SWITCH PRIOR TO DEPARTURE PORT OF MOBILE.
Condition: Unknown
Due 15 July 1994
Resolved 20 July 1994
Engineering
Issued 8 July 1994
Resolved
REMOVE FUEL FROM THE BILGE OF THE BALLAST PUMP VOID, TO BE DISPOSED OF IN APROPER METHODS PRIOR TO DEPARTURE.
Condition: Unknown
Due 17 July 1994
Resolved 20 July 1994
Construction/Loadline
Issued 14 February 1994
Resolved
MAKE PERMANNENT REPAIRS TO PORT BOW RAKE,#1-3 VOIDS AND PORT STERN RAKE AT NEXT DRY DOCKING AND/OR NOT LATER THAN 15 APR94.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Construction/Loadline
Issued 27 July 1990
Resolved
REPLACE VENT CLOSURE ON NUMBER -4- STARBOARD VOID.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Electrical
Issued 22 August 1989
Resolved
INSTALL LEAD LINERS IN ALL THREE NAV-LIGHT BATTERY BOXES.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Navigation
Issued 22 August 1989
Resolved
PERMANENTY MARK PLIMSEL MARKING ON VESSEL'S STARBOARD SIDE.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989