Records from 1981 to 2007. Most recent: inspection, 7 December 2007.
Inspection history · 300
7 December 2007
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3113643
26 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3007897
14 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2872098
24 October 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2808150
20 October 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804548
13 October 2006
Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2799676
6 October 2006
Excursion Permit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2795512
25 September 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2786364
25 July 2006
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2725321
19 July 2006
Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2717956
14 July 2006
Administrative Inspection · Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2712485
5 July 2006
MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2701877
23 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2693537
16 June 2006
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2681511
27 May 2006
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2672034
25 May 2006
Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2658809
24 January 2006
MTSA Verification · Drydock Extension · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2572363
27 October 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2523063
9 October 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2510960
21 September 2005
Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2497225
16 August 2005
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2465140
5 July 2005
MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2415669
20 June 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2396805
8 March 2005
MTSA Verification · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2296650
27 January 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2281779
4 January 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2268504
15 November 2004
Periodic Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2241039
11 October 2004
Examination of Repairs
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2218868
29 August 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2180893
9 August 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2160909
9 August 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2162009
2 August 2004
Periodic Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2153218
1 June 2004
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2085199
10 May 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2077906
4 May 2004
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2060451
26 April 2004
Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2055113
2 February 2004
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1983433
17 October 2003
Excursion Permit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1931591
4 September 2003
Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1897444
22 April 2003
Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1779322
24 January 2003
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1731374
25 October 2002
Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1699012
8 August 2002
Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1676236
5 July 2002
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1643388
31 May 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1650585
17 April 2002
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1605915
19 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 495319
1 August 2001
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1070716
12 July 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1466785
16 April 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445792
2 April 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059876
7 March 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1060272
28 February 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059672
5 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 52237
26 January 2001
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462168
18 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373291
30 October 2000
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1413816
25 September 2000
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1054525
23 September 2000
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 824792
21 September 2000
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 821983
20 September 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 96048
19 July 2000
Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1444378
19 April 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365709
9 March 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816745
11 February 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 814165
24 January 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391193
15 November 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808578
25 October 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1393265
15 October 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 810087
30 September 1999
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 64625
22 July 1999
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1460337
27 April 1999
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 793387
16 April 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408289
18 February 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 802977
31 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1125139
30 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 80645
20 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 123088
20 January 1999
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472621
29 October 1998
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 804839
6 October 1998
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1444062
24 August 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1132091
1 August 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1131129
20 July 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1130554
18 July 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1411712
7 July 1998
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1128472
6 July 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 137155
24 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1129730
16 June 1998
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 792205
15 June 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 24123
16 April 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372225
3 April 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 122914
12 February 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 776319
1 February 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 26166
28 January 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107754
12 January 1998
COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433299
15 December 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451251
13 November 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392799
23 October 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1400664
9 October 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 149995
5 October 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 183777
23 September 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1113841
14 August 1997
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1118943
4 August 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1431833
15 July 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1117064
1 July 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777591
18 June 1997
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1112121
14 June 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 152062
23 April 1997
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1096699
13 April 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364068
9 April 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364054
27 March 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435863
27 February 1997
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1095147
27 January 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1106894
23 January 1997
COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434510
19 October 1996
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1172217
10 October 1996
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1396616
22 September 1996
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 486089
16 September 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1145096
13 August 1996
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 496507
5 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1089705
29 July 1996
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1089039
26 July 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1089815
26 July 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1090790
24 July 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1087415
23 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086366
12 July 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1421171
2 July 1996
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1087119
24 June 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1090872
11 June 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1186983
30 May 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086237
17 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455374
30 April 1996
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1082430
29 April 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 96477
18 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417929
2 April 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078190
21 March 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078063
15 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451047
9 March 1996
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428600
16 February 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1191333
19 January 1996
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452109
22 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424171
29 October 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 108128
25 October 1995
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 884177
10 October 1995
Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 886063
6 October 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 875839
24 August 1995
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 493544
25 July 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 88487
21 July 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457283
19 July 1995
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 877071
19 July 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1187834
16 June 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878472
22 May 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 870657
12 May 1995
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1419441
6 May 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 870252
5 May 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340534
4 May 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 97055
18 April 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425583
29 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 832416
24 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 183374
24 March 1995
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141763
17 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835459
24 February 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850609
15 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456246
14 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21254
10 February 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374208
9 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 64057
6 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 643574
30 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829030
23 January 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374179
7 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 3010
16 December 1994
Sanitary Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 844294
4 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401949
3 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420922
28 October 1994
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870384
14 October 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1179075
27 September 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 866701
22 September 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460752
21 September 1994
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 83449
11 September 1994
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 163603
11 September 1994
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1176521
1 September 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 862222
18 August 1994
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1180437
10 August 1994
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1173740
19 July 1994
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1172482
24 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385207
27 May 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 861238
22 April 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387509
26 January 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444783
12 November 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141832
29 October 1993
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 106768
29 October 1993
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 836513
26 October 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 665697
22 October 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 847590
8 October 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835736
19 August 1993
Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 845234
23 July 1993
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 826510
14 May 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387332
19 April 1993
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1150390
12 April 1993
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358042
11 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 140931
25 January 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829941
20 January 1993
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1144438
24 October 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1247806
14 October 1992
Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 953116
8 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 941481
21 September 1992
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1419050
18 September 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 140673
20 August 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 147102
28 July 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1257429
24 April 1992
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 943744
5 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314868
7 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956508
27 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665698
25 January 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263574
13 December 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 948622
28 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248827
13 August 1991
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 933997
28 June 1991
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1251944
24 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213938
10 May 1991
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1234566
8 May 1991
Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 922580
7 May 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 903580
7 May 1991
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 919610
17 April 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220206
19 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230905
19 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1231536
19 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232885
19 March 1991
Plan Review "T" Boat
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240405
4 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923660
19 February 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901077
4 February 1991
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997130
28 December 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918170
24 December 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225027
7 December 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1242466
30 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917481
9 August 1990
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1213963
8 June 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904884
27 April 1990
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1233294
13 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900822
19 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931561
18 March 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924418
25 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225674
1 December 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241899
27 November 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1231967
10 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899927
8 September 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206957
7 September 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890014
1 September 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042045
2 June 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197826
17 May 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1351618
28 April 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890738
24 February 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198684
23 February 1989
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042193
16 February 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345733
23 December 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039735
2 December 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896728
22 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206261
30 September 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1198627
21 September 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350880
2 September 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350455
4 July 1988
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894394
3 June 1988
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 888413
20 May 1988
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1044305
11 February 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316885
30 November 1987
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335345
13 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309534
13 November 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337506
23 July 1987
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1335829
1 May 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030036
13 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020007
29 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001819
28 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320561
14 November 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326598
7 November 1986
Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329404
17 October 1986
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1009483
10 October 1986
Re-Inspection
Physical examination · MSO CINCINNATI · Activity 1007324
23 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1312072
12 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1001643
22 August 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1028480
15 August 1986
Re-Inspection
Physical examination · MSO CINCINNATI · Activity 1293959
28 March 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998938
24 December 1985
Damage Survey · Permit to Proceed
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298718
22 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294415
13 September 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296086
6 September 1985
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1297223
19 August 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 985404
14 August 1985
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 986080
7 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287706
14 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289135
10 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282084
10 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281457
24 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974161
10 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279115
2 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279637
27 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972427
28 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277181
20 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968614
7 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967927
22 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273714
17 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970312
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 October 2006
Resolved
Vessel is to comply with the operations outlined in the action plan reviewed by the Food and Drug Administration until such time as cleared by the cognizant Officer in Charge, Marine Inspection.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 7 November 2006
Resolution: Received notice from FDA that vessel has met all cleaning and sanitation requirements under the approved action plan.
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 October 2006
Resolved
Vessel master is to notify immediately the cognizant Officer in Charge, Marine Inspection if more than 12 persons on board develop symptoms prior to 31-OCT-2006.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 27 October 2006
Resolution: Vessel reported that 13 personnel on board had developed symptoms consistent with the illness previously reported on board. After contacting vessel and FDA, additional personel were still developing symptoms. Vessel halted currently scheduled cruise.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 24 October 2006
Resolved
Due to concerns affecting the safety of passengers and the vessel's fitness for service, vessel is hereby restricted from getting underway or engaging in further passenger operations until approved by the Officer in Charge, Marine Inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2006
Resolved 28 October 2006
Resolution: CG-835 modified to allow vessel to get underway. Consulted FDA personnel and they recommended allowing vessel to proceed, without passengers, to a location with better decon/cleaning support facilities.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 24 October 2006
Resolved
Due to concerns affecting the safety of passengers and the vessel's fitness for service, vessel is hereby restricted from engaging in further passenger operations until approved by the Officer in Charge, Marine Inspection.
Action required: 705 - Other - as specified
Due 8 November 2006
Resolved 8 November 2006
Resolution: Vessel found to be in compliance with all FDA requirements and appears safe for continued passenger service.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2006
Resolved
Clean main galley ovens to prevent grease fires in ovens and clean deck to prevent slip hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 4 August 2006
Resolution: Ovens cleaned.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2006
Resolved
Clean crew galley ovens to prevent grease fires in ovens and clean deck to prevent slip hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 4 August 2006
Resolution: Ovens and deck cleaned.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2006
Resolved
Clean decks and drains in all bars onboard to prevent slips trips and falls.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 4 August 2006
Resolution: Deck and drains cleaned.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 July 2006
Resolved
Properly install loose wire in crews galley oven by drip pan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2006
Resolved 25 July 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 July 2006
Resolved
Properly repair emergency light in EDG room.
Condition: Improper/Lack of Maintenance
Due 26 July 2006
Resolved 19 July 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 July 2006
Resolved
Properly repair emergency lighting in lower E/R and boiler room.
Condition: Improper/Lack of Maintenance
Due 26 July 2006
Resolved 19 July 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 July 2006
Resolved
Provide bracket for CO2 extinguisher in engine room.
Condition: Improper/Lack of Maintenance
Due 19 August 2006
Resolved 19 July 2006
Fire Fighting › Ventilation Systems › Fans
Issued 19 July 2006
Resolved
Prove proper operation of E/R and chiller room emergency ventilation shutdown.
Condition: Improper/Lack of Maintenance
Due 26 July 2006
Resolved 19 July 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 July 2006
Resolved
Prove inspection of semi-portable extingusiher in boiler.
Condition: Improper/Lack of Maintenance
Due 26 July 2006
Resolved 19 July 2006
Electrical › Electric Generation Source (emergency) › Generator
Issued 19 July 2006
Resolved
Prove proper operation of emergency diesel generator prior to getting underway.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2006
Resolved 20 July 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 19 July 2006
Resolved
Provide captain's original license onboard the vessel prior to getting underway.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2006
Resolved 20 July 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 July 2006
Resolved
Prove proper operation of fire scren doors #49 and #34.
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 14 July 2006
No resolution recorded
Vessel has a 20"x5/8" fracture in the forepeak tank. Currently vessel under a D/D extension until 30Nov06. Fracture at keel in forepeak ballast tank to be repaired IAW NVIC 7-68. The following to be completed until repairs completed. 1. Forepeak secured during any transit. 2. Sound forepeak and log every 6 hours. 3. Examine underwater hull with the use of divers on a monthly schedule.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2006 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 5 July 2006
Resolved
Vessel is prohibited from departing the port of St. Louis until written proof of a valid Certificate of Financial Responsibility is provided to Sector Upper Mississippi River (USCG).
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2006
Resolved 5 July 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 June 2006
Resolved
Sector LMR, issued CG 835 for the following. 1. Make permanent repairs to starboard fuel settling tank by 30 jun06. 2. Strip port fuel settling tank every day and record it in log book. 3. If repairs are not made by 30 jun06 vsl can not carry passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 23 June 2006
Resolution: Tank was drained and cleaned. A steam valve was leaking and repairs made. 80 psi held for over 20 minutes. 835 cleared.
Construction/Loadline › Hull › Hull Plating
Issued 27 May 2006
Resolved
- Ensure fore peak is secured during transit
- Make rounds, sound, and log soundings of fore peak tnk, NLT every 6 hrs, during transit
- Make permanent repairs to hull fracture at keel, between frms 136-137, in fore peak/ballast tnk., reference NVIC 6-68, during next DD and NLT 31JUL06 (referenced, current DD extension).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 14 July 2006
Resolution: This requirement cleared. Another requirement was issued to reflect the dry-dock extension that was granted on 13Jul06. The new dry-dock due date is now 30NOV06. All above requirements were re-issued.
Construction/Loadline › Hull › Bottom Plating
Issued 25 May 2006
Resolved
Vessel allowed to transit to Nashville, TN to complete temporary repairs.
Action required: 705 - Other - as specified
Resolved 27 May 2006
Resolution: Temporary repairs made to satisfaction of attending MI, as required by MSU PADUCAH (MI).
Engineering › Pressure Vessel › Relief Valve
Issued 22 April 2006
No resolution recorded
Conduct test of pressure relief valve for DC heater and make pressure vessel ready for internal inspection at next dry-dock.
Action required: 705 - Other - as specified
Due 31 July 2006 — due date passed with no resolution recorded
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 22 April 2006
Resolved
Provide new flash hoods for all members of fire party.
Action required: 705 - Other - as specified
Due 7 May 2006
Resolved 24 May 2006
Resolution: Examined new flash hoods
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 April 2006
Resolved
Provide switch covers for FSD'S 31, 47, and 49 switches.
Action required: 705 - Other - as specified
Due 7 May 2006
Resolved 24 May 2006
Resolution: Observed switch covers on FSD.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 April 2006
Resolved
Prove proper operation of remote control for FSD 47. The following individuals will secure doors from local remote: (1) [name withheld] 3130, (2) [name withheld] 9466 for drills or emergencies.
Action required: 705 - Other - as specified
Due 7 May 2006
Resolved 24 May 2006
Resolution: Observed satisfactory remote operation of FSD 47.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 September 2005
Resolved
Provide proof of fire extinguisher service, tag missing from extinguisher.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 21 September 2005
Resolution: Proof provided for annual service.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 September 2005
Resolved
Provide proof of service, tag missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 21 September 2005
Resolution: Proof provided for annual service.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 September 2005
Resolved
Remove trash from fuel vent containment.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2005
Resolved 21 September 2005
Resolution: Trash removed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 21 September 2005
Resolved
Remove trash from behind starboard bar under machinery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2005
Resolved 21 September 2005
Resolution: Trash removed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 June 2005
Resolved
Replace port side pilot house door, fanroon/elevator access door, conex storage space door, and electric access door.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 29 June 2005
Resolution: Port side pilot house door, fan room/elevator access door, conex storage space door, and electic access door replaced.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 20 June 2005
Resolved
Replace damaged stbd #1 liferaft due to damage sustained during docking in Baton Rouge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: Stbd #1 liferaft replaced.
Construction/Loadline › Structures › Door
Issued 20 June 2005
Resolved
Replace glass on stbd side pilot house door with re-enforced glass.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 29 June 2005
Resolution: Glass (re-enforced) on stbd side pilot house door
Lifesaving › Rescue Boat › Propulsion Engine
Issued 7 March 2005
Resolved
The outboard on the rescue boat failed to start. Uncertain as to the cause of its failure. Vessel required to prove proper operation of the outboard prior to the loading passengers on 08 MAR 2005.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2005
Resolved 8 March 2005
Resolution: A new outboard engine was purchased for the rescue boat.
Stability › Watertight Integrity › General
Issued 7 March 2005
Resolved
No. 2 sliding water tight door controller disconnect switch was inoperable. This does not allow the door to be tested locally, simulating 'no-power' to the door and using the stored energy in the accumulator to operate the door. Required to demonstrate the proper operation of No. 2 sliding water tight door controller disconnect switch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2005
Resolved 8 March 2005
Resolution: Proved proper operation of No. 2 sliding water tight door controller disconnect switch.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 March 2005
Resolved
Install proper labeling and prove proper manual operation of all fire dampners.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2005
Resolved 8 March 2005
Resolution: Vessel created an improved Fire Control Plan that properly labels all existing fire dampners and maintains a master list of all fire dampners operated manually or by fusible link. Fire dampners are labeled on location.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 7 March 2005
Resolved
Fire Screen Doors 35, 36, 37, 38, 41 and 49 failed to properly latch and close following activation. Required to prove proper operation of all Fire Screen Doors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2005
Resolved 8 March 2005
Resolution: Proved proper operation of all Fire Screen Doors.
Engineering › Steam Boiler (propulsion) › Screen Tube
Issued 11 October 2004
Resolved
Permanently repair port boiler tubes IWO temporary repairs upon returning to New Orleans , LA, but not later than 16NOV2004. Temporary window repairs were completed on 11OCT2004 to the following tubes: Screen Tubes - Nr. 12, 15, 16, 19, 29, 30, 31, 32 & 40 along with Wall Tube - Nr. 25. In addition the following Screen Tubes were plugged Nr. 20, 23, 28 & 34.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2004
Resolved 7 March 2005
Resolution: Retubed boiler, conducted hydrostatic test with satisfactory result.
Engineering › Steam Boiler (propulsion)
Issued 4 May 2004
Resolved
Conduct ultrasonic test on port main propulsion boiler screen tubes, test should be completed on at least 20% of total tubes. Make permanent repairs to effected screen tubes. LEGACY COMPONENT DESC: Firewall Tube
Condition: Unknown
Due 4 June 2004
Resolved 1 June 2004
Resolution: Reviewed ultrasonic report of tubes found sat.
Engineering › Steam Boiler (propulsion)
Issued 25 October 2002
Resolved
Make permanent repairs to stbd boiler tubes #15, 17, 18, 19, 22, & 23 that were temporarily repaired during port call in Louisville, KY on 25OCT02. Repairs and hydrostatic testing shall be to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Rear Wall/Side Wall Tubes
Condition: Unknown
Due 31 January 2003
Resolved 13 January 2003
Resolution: CG-835 issued by LOUMS, cleared by NEWMS on 1/13/03 by a [name withheld] (sic). The discrep was never cleared in MISLE. This discrep will be administratively cleared by this activity.
Lifesaving
Issued 12 July 2001
Resolved
PROPERLY REPAIR #4 LIFE RAFT CRADLE.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Fire Fighting
Issued 12 July 2001
Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOORS #34, 36, 40, 41, 43, AND 45.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Electrical
Issued 7 March 2001
Resolved
UPDATE ELECTRICAL PANEL DIRECTORIES WITH LISTING AND AMPERAGE.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Fire Fighting
Issued 7 March 2001
Resolved
REPAIR/REPLACE LATCHES ON DOORS AS NEEDED. (NUMEROUS PASSAGE DOORS FROM INTERIOR TO EXTERIOR ARE MISSING LATCHES OR LATCHES DO NOT WORK).
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Fire Fighting
Issued 26 January 2001
Resolved
REPAIR/REPLACE LATCHES ON DOORS AS NEEDED. (NUMEROUS PASSAGE DOORS FROM INTERIOR TO EXTERIOR ARE MISSING LATCHES OR LATCHES DO NOT WORK)
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Electrical
Issued 26 January 2001
Resolved
SECURE WIRING RUN IN DECK LOCKER PROMENADE DECK AFT, REPLACE STUFFING TUBES
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Electrical
Issued 26 January 2001
Resolved
UPDATE ELECTRICAL PANEL DIRECTORIES WITH LISTING AND AMPERAGE.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Fire Fighting
Issued 26 January 2001
Resolved
REPAIR/ADJUST FIRE SCREEN DOORS NR 6, 11, 29, 40, 41 AND 48.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Construction/Loadline
Issued 21 September 2000
Resolved
The #1 port ballast tank is fractured 2" and 18" forward of frame 108. The first is approximately 2" long; the second is approximately 18" long. Make temporary repairs to the satisfaction of the cognizant Officer in Charege, Marine Inspection.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Construction/Loadline
Issued 21 September 2000
Resolved
The #1 port ballast tank is fractured 2" and 18" forward of frame 108. The first is approximately 2" long; the second is approximately 18" long. Makepermanent repairs to the satisfaction of the cognizant Officer in Charege, Marine Inspection.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Fire Fighting
Issued 19 July 2000
Resolved
ENSURE PROPER OPERATION OF FIRE SCREEN DOORS (NUMBERS 15, 34, 38 AND 41).
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Accommodation/Occupational Safety
Issued 19 July 2000
Resolved
PROPERLY CLEAN CREW'S GALLEY AND MESS AREA.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 24 January 2000
Resolved
REPLACE FIRE SCREEN DOORS NR 48 AND 49.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Accommodation/Occupational Safety
Issued 24 January 2000
Resolved
CLEAN AIR HANDLER SPACES 04, 05, 06 AND 15 (LENT AND FLAMMABLES).
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000
Resolved
PROVIDE APPROVED PLANS FOR FIXED FIRE EXTINGUISHING SYSTEM IN MAIN AND CREWGALLEYS.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 25 October 1999
Resolved
PROPERLY REPAIR OR ADJUST F/S DOOR #4, 8, 21, 37, 39, 40, 49.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Construction/Loadline
Issued 25 October 1999
Resolved
INVESTIGATE CAUSE OF FRACTURE IN OVERHEAD LOCATED IN PADDLE ROOM BAR.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Lifesaving
Issued 16 April 1999
Resolved
REPLACE RESCUE BOAT WINCH CABLE.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Unknown
Issued 16 April 1999
Resolved
REPLACE FLEXIBLE HOSE ON AIR COMPRESSOR BY STEERING STATION.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Electrical
Issued 31 January 1999
Resolved
Prior to releasing tug escort during underway periods, provide alternative generator power source. Prove proper operation and installation of replacement starboard generator to the satisfaction of the attending marineinspector.
Condition: Unknown
Due 31 January 1999
Resolved 31 January 1999
Electrical
Issued 20 January 1999
Resolved
REPAIR EMERGENCY LIGHTS AS NECESSARY. CURRENT LIGHTS AT PADDLEWHEEL LOUNGE PORT ENTRY, TEXAS FWD EXIT, & OUTSIDE CREW CABIN 010 ARE OUT.
Condition: Unknown
Due 22 January 1999
Resolved 1 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
INSULATE PORTION OF DECK OVER STATEROOM IN LOCKER 36.
Condition: Unknown
Due 20 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999
Resolved
REMOVE EXTENSION CORD FROM LIGHT ON TEXAS DECK AT ICE SERVICE AREA.
Condition: Unknown
Due 22 January 1999
Resolved 1 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
FREE DAMPER AT RESCUE BOAT.
Condition: Unknown
Due 22 January 1999
Resolved 1 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
REPAIR FIRE SCREEN DOORS #'S 8(HOLD), 7, 42, 43, 29, 49, 35, 6, 8, 48, 49, 40 & 41 AND OTHERS AS NECESSARY. 22MAR99: ALL CLEARED EXCEPT 40 & 41.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Electrical
Issued 20 January 1999
Resolved
MOUNT ELECTRICAL JUNCTION BOX AT FRAME 95, STBD. PROVIDE COVER PLATE IN STATEROOM 106.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Fire Fighting
Issued 20 January 1999
Resolved
PROPERLY INSULATE DECK IN ENGINEER'S OFFICE.
Condition: Unknown
Due 20 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
REPLACE DOORS IN HOLD DECK MIDSHIP STAIRTOWER/PASSAGEWAY AREA W/APPROVED DOORS.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Fire Fighting
Issued 20 January 1999
Resolved
INSULATE DECK AT STEPPED MVZ ON OBSERVATION DECK AT LIBRARY.
Condition: Unknown
Due 20 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
REPAIR PENETRATIONS IN FIRE ROOM FORWARD BULKHEAD.
Condition: Unknown
Due 20 March 1999
Resolved 23 March 1999
Fire Fighting
Issued 20 January 1999
Resolved
REPLACE UNAPPROVED CEILING PANELS AS NECESSARY THROUGHOUT VESSEL.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Fire Fighting
Issued 20 January 1999
Resolved
REPAIR FIRE DAMPERS AT PROMENADE SPACE PER EDQUIST REPORT.
Condition: Unknown
Due 22 January 1999
Resolved 1 February 1999
Construction/Loadline
Issued 6 October 1998
Resolved
Replace or repair missing valve handle to bilge manifold, main machinery space.
Condition: Unknown
Due 7 October 1998
Resolved 26 October 1998
Fire Fighting
Issued 6 October 1998
Resolved
Repair fire door located midship starboard side to completely close upon release.
Condition: Unknown
Due 7 October 1998
Resolved 26 October 1998
Fire Fighting
Issued 6 October 1998
Resolved
Repair fire damper to close for machinery space located on the aft portsideand midship starboard side.
Condition: Unknown
Due 7 October 1998
Resolved 26 October 1998
Accommodation/Occupational Safety
Issued 6 October 1998
Resolved
Repair electrical plugs for crew's cloths dryer in crew berthing area.
Condition: Unknown
Due 7 October 1998
Resolved 26 October 1998
Electrical
Issued 6 October 1998
Resolved
Repair emergency lighting lamp in crew's berthing and 02 deck, midship, portside.
Condition: Unknown
Due 7 October 1998
Resolved 26 October 1998
Electrical
Issued 18 July 1998
Resolved
Install numbers on breakers in panel #3 located in the fireroom.
Condition: Unknown
Due 18 July 1998
Resolved 18 July 1998
Construction/Loadline
Issued 18 July 1998
Resolved
Adjust latch on paint locker door in engine room, ensure door closes properly.
Condition: Unknown
Due 18 July 1998
Resolved 18 July 1998
Electrical
Issued 18 July 1998
Resolved
Prove proper operation of battery E-light, 3rd deck, atrium, grand staircase, port side.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Electrical
Issued 18 July 1998
Resolved
Prove proper operation of EDG emergency stop.
Condition: Unknown
Due 18 July 1998
Resolved 18 July 1998
Construction/Loadline
Issued 16 June 1998
Resolved
MAKE PERMANENT REPAIRS TO 6" FRACTURE AT FRAME 19, PORT BILGE KNUCKLE. ENSURE TEMPORARY REAPIRS ARE EFFECTIVE BY HOURLY ROUNDS OF SPACE.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Electrical
Issued 12 January 1998
Resolved
PROPERLY BAND ELECTRICAL/COAXIAL CABLE IN PROJECTION ROOM. CABLE SHOULD BEBANDED IN ACCORDANCE WITH IEEE STD 45.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF THE LOW FUEL TEMP ALARM FOR THE BOILERS.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVIDE CG INSPECTOR WITH CG APPROVED COPY OF AUTOMATION TEST PROCEDURES.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF HAND LIFTING GEAR ON ALL BOILER SAFETIES.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Electrical
Issued 12 January 1998
Resolved
REMOVE DEAD END WIRE ON BULKHEAD ABOVE BATTERY CHARGER IN E-GEN ROOM.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
PRIOR TO SAILING. REPAIR BOILER SAFETY VALVE ON STBD BOILER.
Condition: Unknown
Due 12 January 1998
Resolved 21 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF HIGH WATER ALARMS ON BOTH BOILERS.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Construction/Loadline
Issued 12 January 1998
Resolved
REPLACE WEATHERTIGHT DOOR, MAIN DECK FWD LEADING TO LOWER CREW SPACES.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Fire Fighting
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF ALL ACCOMADATION SPACE REMOTE VENTILATION SHUTDOWNS FROM ALL STATIONS.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Electrical
Issued 12 January 1998
Resolved
INSTALL PROPER JUNCTION BOXES FOR CONNECTIONS IN BOTH BOILER LOCAL GUAGE PANELS.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Lifesaving
Issued 12 January 1998
Resolved
REMOVE EXCESS LIQUOR FROM LIQUOR LOCKER.
Condition: Unknown
Due 12 February 1998
Resolved 22 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF LOW OIL ALARM FOR PORT BOILER.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Accommodation/Occupational Safety
Issued 12 January 1998
Resolved
REPLACE DRYER VENT DUCT IN FWD CREWS SPACE.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Engineering
Issued 12 January 1998
Resolved
INSTALL A HIGH STEAM PRESSURE ALARM ON BOTH BOILERS OR SUBMIT CHANGE TO AUTOMATION TEST PROCEDURES FOR CG APPROVAL.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Construction/Loadline
Issued 12 January 1998
Resolved
REPLACE/REPAIR DOGS ON STBD BOW THRUSTER ROOM WATERTIGHT HATCH. PROVE TO BE WATERTIGHT.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Electrical
Issued 12 January 1998
Resolved
RENEW BROKEN CABLE FOR STBD STEAM ENGINE HIGH BEARING TEMP ALARM.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Electrical
Issued 12 January 1998
Resolved
PROPERLY SECURE THE BATTERIES FOR ENGINE ROOM/FIRE ROOM PANELS LOCATED IN THE E-GEN ROOM.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Lifesaving
Issued 12 January 1998
Resolved
REPLACE MISSING PIPE INSULATION ON LINE ABOVE PORT GENERATOR GOVERNOR.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Lifesaving
Issued 12 January 1998
Resolved
CLEAN DIRT/OIL OUT OF E-GEN ROOM FIRE DAMPER.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Fire Fighting
Issued 12 January 1998
Resolved
REPAIR LOOSE FIRE DAMPER IN PASSAGEWAY JUST AFT OF E-GEN ROOM.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
PROVE PROPER OPERATION OF THE LOW ATOMIZING AIR ALARM FOR PORT BOILER.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Electrical
Issued 12 January 1998
Resolved
REPAIR GOVERNOR SURGE ON EMERGENCY GENERATOR.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Lifesaving
Issued 12 January 1998
Resolved
REMOVE ALL SUPPLIES FROM ELECTRICAL PANEL IN BOILER ROOM BEHIND BOILER CONTROL PANEL.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Lifesaving
Issued 12 January 1998
Resolved
REMOVE WOODEN DECK PLANK FROM IN FRONT OF THE ELECTRICAL PANEL IN BOILER ROOM. INSTALL PERMANENT DECK PLATE OR GRATING.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Engineering
Issued 12 January 1998
Resolved
REPLACE MISSING LAMP COVERS ON PORT BOILER LOW/LOW WATER AND STBD BOILER FLAME FAILURE ALARMS.
Condition: Unknown
Due 12 February 1998
Resolved 23 January 1998
Accommodation/Occupational Safety
Issued 15 December 1997
Resolved
SUBMIT A PROPOSAL TO OCMI FOR CORRECTION OF VENTILATION BOUNDARY PENETRATIONS IDENTIFIED IN THE AS CONSTRUCTED STRUCTURAL FIRE PROTECTION DRAWINGS AND VENTILATION DRAWINGS.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 15 December 1997
Resolved
SUBMIT A PROPOSAL TO THE OCMI FOR CORRECTION OF OUTSTANDING STRUCTURAL FIREPROTECTION ISSUES IDENTIFIED DURING PREVIOUS INSPECTIONS AND DURING SURVEY FOR AS CONSTRUCTED STRUCTURAL FIRE PROTECTION DRAWINGS.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 15 December 1997
Resolved
PROVIDE AN ACCURATE SET OF AS CONSTRUCTED STRUCTURAL FIRE PROTECTION DRAWINGS TO OCMI FOR VERIFICATION.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 15 December 1997
Resolved
DEMONSTRATE PROPER INSTALLATION AND OPERATION OF FIRE DAMPER IN LOCKER 5 HOLD DECK PRIOR TO USE AS A TYPE 9 STOREROOM.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Accommodation/Occupational Safety
Issued 15 December 1997
Resolved
PROVIDE A COPY OF AS CONSTRUCTED VENTILATION DRAWINGS TO OCMI.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Electrical
Issued 15 December 1997
Resolved
REMOVE OR PROPERLY BAND COAXIAL CABLE IN TEXAS DECK, PORT SIDE, AFT CORRIDOR OVERHEAD IN WAY OF CABIN 354. BANDING SHOULD BE IN ACCORDANCE WITH IEEE STANDARD.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Electrical
Issued 15 December 1997
Resolved
REMOVE OR BAND COAXIAL CABLE IN PILOT'S CORRIDOR OVERHEAD. BANDING SHOULD BE IN ACCORDANCE WITH IEEE STANDARD.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Accommodation/Occupational Safety
Issued 23 October 1997
Resolved
Properly clean all ventilation ducts and filters in main galley.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Construction/Loadline
Issued 23 October 1997
Resolved
Repair/adust dogs on escape hatch in chiller space stbd side.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Deck/Cargo
Issued 23 October 1997
Resolved
Hydro test or remove oil transfer hose.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Fire Fighting
Issued 23 October 1997
Resolved
Make all smoke detectors operable in all spaces.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Fire Fighting
Issued 23 October 1997
Resolved
Install sign for deep fat fryer fire supression system.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Electrical
Issued 23 October 1997
Resolved
Repair F/O leaks on emergency diesel generator F/O supply return hoses.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Fire Fighting
Issued 4 August 1997
Resolved
Properly secure the portable fire extinguishers that are in the vicinity ofthe Conex storage container on the sun deck.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 4 August 1997
Resolved
Properly stencil and identify the new manual fire dampers including A-H-14 and 15 on the promenade deck.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 9 April 1997
Resolved
REMOVE COMBUSTIBLE TRIM AND/OR NON-FIRE RESISTANT FURNISHINGS FROM EXCERCISE ROOM, CAPTAINS CABIN, EXECUTIVE DIRECTORS CABIN, CABIN 437, CABIN439, HOTEL OFFICE, AND MASTER'S OFFICE OR UPGRADE SPACES TO TYPE "6".
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Documentation
Issued 9 April 1997
Resolved
REMOVE TEMPORARY CONNEX BOX FROM SUN DECK AFT OF 47 OR SUBMIT PROPOSAL FOR PERMANENT INSTALLATION. PROPOSAL SHOULD ADDRESS STRUCTURAL FIRE PROTECTIONAND STABILITY ISSUES.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Fire Fighting
Issued 9 April 1997
Resolved
REMOVE EXCESS LIQUOR FROM DAY LOCKER 44 AND PROVIDE DAILY INVENTORY SHEET TO BE POSTED INSIDE LOCKER.
Condition: Unknown
Due 9 May 1997
Resolved 15 April 1997
Fire Fighting
Issued 9 April 1997
Resolved
INSULATE BULKHEADS OF LKRS 38 AND 37 THAT ARE ADJACENT TO PASSAGEWAY AND ELEVATOR SHAFTS TO A-60 IAW 46 CFR 72.05-10(D), OR REMOVE COMBUSTIBLES.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Fire Fighting
Issued 9 April 1997
Resolved
PROVE PROPER OPERATION OF VENTILATION REMOTE SHUTDOWNS IN ENGINE ROOM.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Fire Fighting
Issued 9 April 1997
Resolved
INSULATE BULKHEAD BOUNDARIES BETWEEN LKR 47 AND ELEVATOR ENCLOSURES TO A-60IAW 46 CFR TABLE 72.05-10(E) OR REMOVE COMBUSTIBLES.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Engineering
Issued 9 April 1997
Resolved
INSTALL REMOTE SHUTDOWN FOR L.O.P. INSTALLED JAN97.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
PROVIDE INSULATION TO FIRE ROOM OVERHEAD ABOVE FEEDWATER PUMPS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE LAGGING FOR P & S BOILER UPTAKES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR 150 PSI REDUCING STATION FOR F/O HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR P & S FEEDWATER REGULATING PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
COMPLETE REPAIRS TO CABINS 58 AND PILOTS ROOM. CREW MAY NOT BE BERTHED IN THESE COMPARTMENTS UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE FLANGE SHIELDING FOR F/O HEATER PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR - VSL WILL NOT DISCHARGE BILGE SLOPS THRU OWS UNTIL OPERATION IS SATISFACTORY TO A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
DEMONSTRATE SFP IN DINING ROOM OVERHEAD IS INSTALLED IAW APPROVED SFP PLANS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
PROVIDE COVER FOR LIGHT SWITCH BOX PORT SIDE UPPER PADDLEWHEEL BAR.
Condition: Unknown
Due 27 January 1997
Resolved 28 January 1997
Lifesaving
Issued 23 January 1997
Resolved
DEMONSTRATE CIRCUIT BREAKER DIRECTORIES ARE LABELED PROPERLY.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
ENSURE TELEPHONE SYSTEM TRANSFORMER IN PHONE ROOM IS PROPERLY GROUNDED.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
REPAIR LIGHTING SWITCHES AND DIMMERS IN CLOSET BY FSD 49 UPPER PADDLEWHEEL BAR.
Condition: Unknown
Due 23 February 1997
Resolved 28 January 1997
Lifesaving
Issued 23 January 1997
Resolved
INSURE MCI WIRING IN PURSERS OFFICE IS INSTALLED IAW IEEE STANDARD 45 OR REMOVE.
Condition: Unknown
Due 27 January 1997
Resolved 28 January 1997
Lifesaving
Issued 23 January 1997
Resolved
PROVIDE EVIDENCE THAT BATTERY INSTALLATION FOR WATERCOM SYSTEM IN LOCKER #42 IS IAW 46 CFR SUBCHAPTER J.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
REPLACE INSULATION IN ENG ROOM OVERHEAD BY STM SUPPLY LINE TO HP CYLINDER (PORT SIDE)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Electrical
Issued 23 January 1997
Resolved
PROPERLY SECURE MAIN ENGINE ALARM WIRES (P & S)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
LABEL PORT SIDE MANUAL FIRE DAMPERS FOR FIRE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
HARD PIPE DISCHARGE LINE FOR WASHING MACHINE IN ENG ROOM TO SLOP TANK (NOT OVERBOARD)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
PROVIDE COVERS FOR THE FOLLOWING GAUGES 1. VAC GAUGE ON SEWAGE TANK 2. TWO FOR F/O HEATER PSI GAUGES 3. ELECTRO UV WATER PURIFIER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR AIR ATOMIZATION PIPING IN FIRE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE INSULATING COVERS FOR MUD DRUM ACCESS HOLES (P & S)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR FEED WTR PIPING TO DC HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
INSURE HEATING COILS IN VENTILATION SYSTEM IN 400 SERIES CABIN SUITES ARE IAW 46 CFR 111.87-3 (UL 1096/1996). HEATERS MUST BE DISCONNECTED UNTIL REPLACED.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
INSULATE DECK BENEATH LKR 26 TO A-30 IAW APPROVED SFP PLAN.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
DEMONSTRATE CREW LAUNDRY/DAYROOM/OFFICE BOUNDARIES IN THE HOLD DECK ARE IAWAPPROVED SFP PLAN. LAUNDRY SERVICE MUST BE DISCONNECTED UNTIL CORRECTED.
Condition: Unknown
Due 27 January 1997
Resolved 28 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR STEAM LINES TO HOT WATER HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR STEAM DRAINS ON HOT WTR HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR SUPERHEATER SOOT BLOWER (PORT)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR MAIN STEAM CROSSOVER FROM BOILER STOP VALVE (P & S)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR PORT BOILER BOTTOM BLOW PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR MAIN STEAM LINE ESCAPE PIPING ABOVE PORT BOILER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE PIPE INSULATION FOR SUPERHEATER VENT (PORT)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
REPLACE INSULATION ABOVE SEWAGE TANK IN THE FIRE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
PROVIDE INSULATION ABOVE PORT BOILER STEAM DRUM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
REPLACE INSULATION IN ENG ROOM OVERHEAD BY MAIN SWBD AND ABOVE BOTH GENERATORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
PROVIDE APPROVAL OR REMOVE WALL COVERING IN THEATER SPACE BEHIND FIRE RESISTANT CURTAINS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
PROVIDE FLANGE SHIELDING FOR STBD AIR EJECTOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
INSURE GIFT SHOP AND SURROUNDING AREA FIRE BOUNDARIES ARE IAW APPROVED SFP PLAN.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
INSTALL CASTABLE FOR P & S BOILER SAFETY VALVE ESCAPE PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 23 January 1997
Resolved
SUBMIT UPDATED FIRE SAFETY PLAN WITH CHANGES TO FIRE DAMPERS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
DEMONSTRATE LOCKERS 16, 23, AND 25 ARE IAW APPROVED SFP PLANS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
DEMONSTRATE LOCKERS 8 AND 9 BEHIND THE THEATRE HOLD DECK ARE INSULATED IAW APPROVED SFP PLAN (INCLUDES BOUNDARIES). COMBUSTIBLE STORES MAY NOT BE STORED WITHIN THESE SPACES UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
INSTALL A-60 BOUNDARY AT FRAME 80 HOLD DECK BETWEEN LKR 4 AND STAIRWELL. COMBUSTABLE STORES MAY NOT BE STORED IN THIS SPACE UNTIL CORRECTED.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
DEMONSTRATE LIQUER LOCKER BOUNDARIES ARE IAW APPROVED SFP PLAN TO INCLUDE DAMPERS AND INSULATION. NO LIQUER OR OTHER FLAMMABLES ARE TO BE STRORED INSPACE UNTIL CORRECTED.
Condition: Unknown
Due 27 January 1997
Resolved 28 January 1997
Lifesaving
Issued 23 January 1997
Resolved
PROVIDE APPROVED PLANS/CORRESPONDANCE FOR STAGE AREA DIMMER PACK INSTALLATION.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
SUBMIT PLAN TO CORRECT SFP DISCREPANCIES LISTED IN ITEMS 001,003,004,005,006 AND 007 TO [name withheld] ADDRESSED INCLUDE SPACE DESIGNATIONS, FIRE LOAD CALCULATIONS, FURNISHINGS AND EXISTING BOUNDARIES.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Navigation
Issued 10 October 1996
Resolved
SECOND ELEMENT OF STBD NAVIGATION LIGHT INOPERATIVE.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Navigation
Issued 10 October 1996
Resolved
SECOND ELEMENT OF FWD NAVIGATION LIGHT INOPERATIVE.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Accommodation/Occupational Safety
Issued 10 October 1996
Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUT-DOWN FOR FWD VENTILATION SYSTEM.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Electrical
Issued 10 October 1996
Resolved
REPLACE FRAYED ELECTRICAL CABLE TO LIGHT #23, "O" DECK DANCE FLOOR.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Electrical
Issued 10 October 1996
Resolved
REMOVE ALL EXTENSION CORDS TO LIGHTING ABOVE STAGE IN GRAND SALOON.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Navigation
Issued 10 October 1996
Resolved
COPRRECT/UPDATE NAVIGATIONAL CHARTS IN WHEEL HOUSE.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Navigation
Issued 10 October 1996
Resolved
POST "KEY CLOCK" CHART IN WHEEL HOUSE.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Lifesaving
Issued 10 October 1996
Resolved
REPLACE MISSING SEALING BAND, #4 LIFERAFT.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Electrical
Issued 10 October 1996
Resolved
REPLACE CHARRED POWER SUPPLY CABLE IN SUNDECK FANROOM, FR 4.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Engineering
Issued 10 October 1996
Resolved
REPLACE STEAM PRESSURE GAUGE ON AFT, SUNDECL CALLIOPE.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Accommodation/Occupational Safety
Issued 5 August 1996
Resolved
REMOVE WALLCOVERING LABELED AS "WC-3" FROM ALL TYPE 5 ACCOMMODATION SPACES PRIOR TO COMPLETION OF LAYUP PERIOD IN JANUARY 1997.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Fire Fighting
Issued 12 July 1996
Resolved
Adjust and prove proper operation of FSD,s #35, #36 & #41.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996
Resolved
Prove proper operation of Main engine jacket steam relief valve.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996
Resolved
Secure antenna and remove deadend wires from STBD EDG compt on weather deck.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Service all fire station valves and prove proper operation of same. (FS valves #4, #31, #33 & #42 operating improperly)
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996
Resolved
Install covers on light switces in bowthruster space.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996
Resolved
Repair louver on STBD side vent, aft of pilothouse.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Repair vent handle IWO manual fire dampers, main deck, port side and service (clean) vents on port and stbd side so they operate properly.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Properly label paint locker CO2 activation station with instructions.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996
Resolved
Re-configure area in vicinity of emergency escape hatch IWO E/R, STBD side.Allowing escape hatch to open completly.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 12 July 1996
Resolved
Clean knife edge IWO emergency escape hatch, STBD side, E/R.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996
Resolved
Prove proper operation of E/R exhaust/supply vents. (Louvers were hard wired open.)
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 12 July 1996
Resolved
Properly lable start/stop switch for bilge pump in L/L E/R.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996
Resolved
Properly clean and stow all loose gear in bowthruster space.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996
Resolved
Replace all plastic trash cans with trash cans that are approved IAW 46 CFRPart 72.05-55 (4)(b).
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Remove oxy/acetylene outfit from vicinity of paint locker CO2 activation station and properly secure the same.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Prove proper operation of FSD's #15 and 17.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 12 July 1996
Resolved
Properly lable all water tight doors manual hand crank stations.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996
Resolved
Clean air supply vent to machine shop.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996
Resolved
Install closure device on electrical panal door #6 in bowthruster space.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996
Resolved
Proper stow/secure all loose oxy /acetylene bottles in fwd E/R.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Fire Fighting
Issued 12 July 1996
Resolved
Install screws in fire damper flange IWO stbd side FWD E/R.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 30 April 1996
Resolved
PROVIDE PLANS FOR TEMP. REPAIRS AND TIME LINE FOR PERMANENT REPAIRS. NO PASSENGERS FWR OF POOL AREA ON SUNDECK.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
PROVIDE KEYS TO ALL SPACES TO MATE ON WATCH; THIS REQUIREMENT INCLUDES HOTEL AREAS SUCH AS BAR, GIFT SHOP, & PURSER STORAGE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Accommodation/Occupational Safety
Issued 18 April 1996
Resolved
CLEAR EMERGENCY EXIT FOR EASY PASSAGE IN LAUNDRY ROOM; POST "EXIT" SIGNS ONBOTH SIDES OF THE EXIT DOORS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Accommodation/Occupational Safety
Issued 18 April 1996
Resolved
REMOVE COMBUSTIBLE WOODEN SHELF FROM ROOM 007. ENSURE CREW CABINS DO NOT CONTAIN COMBUSTIBLE MATERIALS SUCH AS SHELVING, CHAIRS, OR CABINETS MADE OFWOOD.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Electrical
Issued 18 April 1996
Resolved
PROVIDE SUITABLE BLANKS IN ALL ELECTRICAL PANELS, CONTROL PANELS AND SWITCHBOARDS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 15 March 1996
Resolved
REPAIR/REPLACE OR RENEW ALL MISSING, DAMAGED, DISTORTED INSULATION INCLUDING INSULATION THAT DOES NOT MEET THE APPROPRIATE SFP REQUIREMENTS THROUGHOUT ALL AREAS IN THE BOILER ROOM.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 19 January 1996
Resolved
REPAIR/REPLACE AND PROVE PROPER OPERATION OF THE FUEL OIL (SERVICE PUMPS)RELIEF VALVES
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 19 January 1996
Resolved
PROVIDE CURRENT UPDATED STABILITY LETTER
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 19 January 1996
Resolved
PROVIDE EVIDENCE TO THIS OFFICE WITHIN THIRTY DAYS, THAT ALL NEW WALL COVERINGS MEET THE REQUIREMENTS OF 46 CFR 164.012. NOTE THAT THE MAXIMUM PERMITTED THICKNESS IS 0.75 INCHES.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
PROVIDE EVIDENCE TO THIS OFFICE WITHIN THIRTY DAYS THAT THE CARPETS INSTALLED IN THE TYPE 5 ACCOMMODATION SPACES ARE FIRE RESISTANT.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
SUBMIT FIRELOAD CALCULATIONS FOR THE AFFECTED SPACES TO THE MARINE SAFETY CENTER WITHIN THIRTY DAYS.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
REPAIR/REPLACE OR RENEW ALL MISSING; DAMAGED AND DISTORTED LAGGING AND INSULATION IN BOILER ROOM
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
WITHIN SIX MONTHS, EITHER REMOVE COMBUSTIBLE TRIM, MOLDING, AND OTHER COMBUSTIBLE INTERIOR FINISHES NOT MEETING THE REQUIREMENTS OF 46CFR164.012 OR APPROVED BY THIS OFFICE FORM THE TYPE 5 ACCOMODATIONS SPACES, OR DEMONTSRATE THE SPACE COMPLIES WITH THE SFP REQURIEMENTS OF TYPE 6 SPACE.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Lifesaving
Issued 19 January 1996
Resolved
SUBMIT UPDATED AS IS FIRE AND SAFETY PLAN TO LOCAL OCMI TO REFLECT CONDITIONS ON BOARD.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Electrical
Issued 19 January 1996
Resolved
UPDATE AND PROVIDE A COPY OF THE EMERGENCY LIGHTING CIRCUIT THROUGHOUT THE VESSEL.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 19 January 1996
Resolved
SUBMIT SPECIFICATIONS FOR ALL NEW CARPET, WALL COVERINGS, MATTRESSES TO MSC.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 19 January 1996
Resolved
INSTALL GENERAL ALARM BELL IN BOW THRUSTER ROOM
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 19 January 1996
Resolved
PROVIDE CONTAINMENT (STOWAGE) FOR ALL BOTTLES (GLASS) IN LIQUOR ROOM AS DISCUSSED ON 19JAN96
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 19 January 1996
Resolved
PROVIDE EVIDENCE TO THIS OFFICE WITHIN THIRTY DAYS THAT THE TOTAL CUMULATIVE WEIGHT CHANGE TO THE VESSEL HAS NOT EXCEEDED 2% OF THE LIGHTSHIPDISPLACEMENT OR OBTAIN A NEW STABILITY LETTER FROM THE MARINE SAFETY CENTER.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 19 January 1996
Resolved
SUBMIT TO MARINE SAFETY CENTER FOR EQUIVALENCY DETERMINATION PROVING BULKHEAD BETWEEN PADDLEWHEEL LOUNGE AND STAIRTOWER MEETS A-60 REQUIREMENTS.
Condition: Unknown
Due 14 February 1996
Resolved 15 February 1996
Electrical
Issued 19 January 1996
Resolved
REPAIR/REPLACE INSTALL AND MARK EMERGENCY LIGHTS IAW RESULTS OF E-LIGHT SURVEY HELD PM 18JAN96
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
SUBMIT A DETAILED SCHEDULE FOR THE COMPLETION OF REQUIREMENTS (1) AND (2) OF LETTER FROM [name withheld] 22JAN96 TO THIS OFFICE WITHIN THIRTY DAYS.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 19 January 1996
Resolved
(CONTINUED) AREA AND INCLUDING THE ACTUAL THICKNESS OF ALL THE COMBUSTIBLE INTERIOR FINISHES (INCLUDING THOSE MEETING THE REQUIREMENTS OF 46 CFR 164.012).
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 19 January 1996
Resolved
AS AN INTERIM MEASURE ONLY, PRIOR TO THE CARRIAGE OF PASSENGERS, YOU WILL BE REQUIRED TO INSTALL BATTERY OPERATED SMOKE DETECTORS IN EVERY AFFECTED ACCOMMODATION SPACE. FURTHER YOU SHALL ENSURE THAT TRASH CANS AND ASH TRAYS ARE EMPTIED TWICE PER DAY.
Condition: Unknown
Due 23 January 1996
Resolved 25 January 1996
Fire Fighting
Issued 19 January 1996
Resolved
TOTAL COMBUSTIBLE FINISH VOLUMES MUST BE REDUCED TO THE EQUIVALENT OF 1/10 OF AN INCH FOR ALL TYPE 6 ACCOMMODATION SPACES WITHIN SIX MONTHS. TO DEMONSTRATE COMPLIANCE WITH THIS REQUIREMENT YOU MUST RESUBMIT TO THIS OFFICE YOUR VOLUME COMBUSTIBILITY ANALYSES OMITTING THE CEILING (CONTINUED)
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Lifesaving
Issued 19 January 1996
Resolved
PROVIDE PLAN TO OCMI TO COMPLY WITH MARINE SAFETY CENTER LETTER OF 18JAN96 AND [name withheld] LETTER. PLAN MUST PROVIDE FOR CORRECTION OF ALL ITEMSWITHIN SIX MONTHS (19JULY96)
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 19 January 1996
Resolved
PROVIDE SUITABLE CLOSURES AND LATCHES FOR EXTERIOR DOORS.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Engineering
Issued 25 October 1995
Resolved
FREE-UP THE STICKING HAND RELIEVING GEAR FOR THE PORT MAIN BOILER SAFETY VALVES, PROVE PROPER OPERATION.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Unknown
Issued 25 October 1995
Resolved
REMOVE COMBUSTIBLE AEROSOLS FROM BOILER ROOM (WERE STOWED NEXT TO STBD BOILER).
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Construction/Loadline
Issued 25 October 1995
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF AFT STEERING SPACE PORT BILGE ALARM.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Lifesaving
Issued 21 July 1995
Resolved
PROVIDE LIFE JACKET DONNING INSTRUCTIONS FOR ALL WEATHER DECK STOWAGE LOCATIONS.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Engineering
Issued 21 July 1995
Resolved
LABEL EMERGENCY FUEL SHUTOFF FOR EMERGENCY DIESEL GENERATOR ON THE SUNDECK.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Documentation
Issued 21 July 1995
Resolved
PROVIDE A COPY OF THE STABILITY LETTER ON BOARD THE VESSEL.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Construction/Loadline
Issued 21 July 1995
Resolved
DETERMINE AND ELIMINATE CAUSE FOR EXCESSIVE VIBRATION ON NUMBER 1 AND NUMBER 3 WTD'S. (9AUG95-DEF-CHK REVEALS #3WTD STILL OPERATING WITH EXCESSIVE VIBRATION, VSL WILL CONTACT NEAREST PORT UPON REPAIR COMPLETION)
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Construction/Loadline
Issued 21 July 1995
Resolved
REMOVE PAINT FROM GASKET AND KNIFE EDGE ON NUMBER 4 WTD.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 6 May 1995
Resolved
VESSEL TO HAVE ASSIST TUG OF NOT LESS THAN 1500HP ALONGSIDE UNTIL TEMPORARYREPAIRS COMPLETED AND SATISFACTORY HYDROSTATIC TEST CONDUCTED ON ALL REPAIRED BOILER TUBING TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 May 1995
Resolved 6 May 1995
Engineering
Issued 6 May 1995
Resolved
MAKE PERMANENT REPAIRS TO SEVERAL BOILER TUBES WHICH WERE TEMPORARILY REPAIRED THIS DATE. REPAIRS TO BE MADE DURING THE NEXT SCHEDULED LAY-UP PERIOD. REPAIRS AND HYSTROSTATIC TESTING MUST BE CONDUCTED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 May 1995
Resolved 6 May 1995
Engineering
Issued 18 April 1995
Resolved
REPAIR AND PROVE PROPER OPERATION OF DIESEL FUEL SERVICE COLD START PUMP.
Condition: Unknown
Due 19 May 1995
Resolved 22 May 1995
Electrical
Issued 18 April 1995
Resolved
DETERMINE AND LABEL ALL EMERGENCY LIGHTS. ENSURE THAT ALL EMERGENCY LIGHTING WITH DIMMER OR LIGHT SWITCHES OPERATE INDEPENDANTLY OFF THE EMERGENCY BUS.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 18 April 1995
Resolved
EITHER NUMBER PORTABLE FIRE EXTINGUISHERS & CORRESPONDING STATIONS OR PROVIDE ONLY ONE TYPE AND SIZE OF EXTINGUISHER AS PER 46 CFR 78.47-30.
Condition: Unknown
Due 19 May 1995
Resolved 22 May 1995
Navigation
Issued 18 April 1995
Resolved
REPAIR AND PROVE PROPER OPERATION OF VESSEL'S STEERING/RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 18 April 1995
Resolved
CLEAN PHOTO ROOM, STORE CHEMICALS IN APPROPRIATE LOCKERS, DETERMINE WHY EXISTING EXHAUST AND SUPPLY AIR DOES NOT APPEAR TO BE WORKING.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Documentation
Issued 18 April 1995
Resolved
LOCATE COPY OF APPROVED STRUCTURAL FIRE PROTECTION PLAN FOR VESSEL AND MAKEAVAILABLE FOR REVIEW BY ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Electrical
Issued 23 January 1995
Resolved
PROVIDE PROPER JUCTION BOXES AND COVERS BEHINDTHE FIRE ROOM OPERATING PANELAND IN THE BURNER MANAGEMENT CIRCUITRY PORT AND STARBOARD.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Engineering
Issued 23 January 1995
Resolved
REPAIR/REPLACE PORT SIDE SAFETY VALVE RELIEF ESCAPE PIPING.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Electrical
Issued 23 January 1995
Resolved
REPLACE ELECTRICAL OUTLET/SWITCH ON STATBOARD FORWARD BULKHEAD WITH AN ADEQUATE MARINE OUTLET (WATER PROOF).
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Engineering
Issued 23 January 1995
Resolved
PROVIDE/REPAIR BOILER FLUE GAS PERISCOPES PORT AND STARBOARD AND PROVE PROPER OPERATION TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Engineering
Issued 23 January 1995
Resolved
PROVIDE ADEQUATE AND APPROPRIATE LENSES WITH LABELS ON PORT AND STARBOARD ALARM CONSOLES.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Navigation
Issued 23 January 1995
Resolved
PROVIDE OPERATIONAL TEST OF VESSEL'S STARBOARD STEERING PUMP DEMONSTRATING THE ABILITY TO GO FROM 35 DEGREES PORT TO 35 DEGREES STARBOARD RUDDER IN THE PRESENCE OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Electrical
Issued 23 January 1995
Resolved
REPAIR/REPLACE EMERGENCY GENERATOR JACKET WATER TEMPERATER ALARM/SHUT DOWN TO WITHIN MANUFACTURERS RECOMMENDED 209 DEGREES.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Engineering
Issued 23 January 1995
Resolved
MAKE PERMANENT REPAIRS TO BOILER GAUGE GLASS SHUT OFF VALVES AND PROVE PROPER OPERATION TO ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Engineering
Issued 23 January 1995
Resolved
REPAIR/REPLACE NUMBER 1 FEED PUMP AND PROVE PROPER OPERATION TO A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Navigation
Issued 23 January 1995
Resolved
MAKE PERMANENT REPAIRS TO VESSEL'S PORT RADAR AND PROVIDE OPERATIONAL TEST TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Engineering
Issued 23 January 1995
Resolved
PROVIDE OPERATIONAL TEST OF THE VESSEL'S BOW THRUSTER TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Engineering
Issued 28 October 1994
Resolved
REPLACE PORT BOILER STEAM GENERATING TUBES THAT UNDERWENT TEMPORARY REPAIRSAT ST LOUIS ON 28 OCTOBER 1994.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994
Resolved
CONTACT MSO NEW ORLEANS TO DISCUSS TUBE REPLACEMENT OF PORT BOILER DURING WINTER LAYUP, AND ADDITIONAL ACTIONS TO PREVENT FUTURE OCCURANCES OF TUBE FAILURES.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 27 September 1994
Resolved
REPLACE THREE (3) TEMPORARY REPAIRED BOILER SCREEN TUBES DURING WINTER LAY-UP. TUBES IN QUESTION ARE ON OUTBOARD SIDE OF PORT BOILER, NUMBERING FROM FIREWALL, THE 21ST, 22ND, AND 27TH SCREEN TUBE.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Engineering
Issued 22 September 1994
Resolved
Replace all four repaired water wall tubes, 3-inboard, 1-outboard, in way of the port boiler affected by the 21 Sep 94 boiler casualty.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Accommodation/Occupational Safety
Issued 19 July 1994
Resolved
REPAIR EMERGENCY LIGHT IN PASSAGEWAY BY #64 FIRE STATION.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Fire Fighting
Issued 19 July 1994
Resolved
REPAIR GENERAL ALARM (BELL) IN OFFICER'S MESS.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Fire Fighting
Issued 19 July 1994
Resolved
REPAIR GENERAL ALARM BELL IN STBD SIDE FIRE ROOM.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Accommodation/Occupational Safety
Issued 22 April 1994
Resolved
PROVE PROPER OPERATION FORWARD AND AFT ACCOMMODATION VENTILATION REMOTE SHUTDOWNS AT STARBOARD MIDSHIP STATION MAIN DECK.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Construction/Loadline
Issued 26 January 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF FIRE ROOM HIGH BILGE ALARM.
Condition: Unknown
Due 26 February 1994
Resolved 27 January 1994
Engineering
Issued 29 October 1993
Resolved
A PERMANENT REPLACEMENT OF THE MOVABLE STACK ON THE STARBOARD SIDE, AND THEFIXED STACK (ITEM 1 OF JEFFBOAT PRINT#B6224-ECONOMISER &FIXEDE STACK) ON THE STARBOARD SIDE SHALL BE COMPLETED PRIOR TO 28JAN94._x001C_ _x001C_
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Engineering
Issued 29 October 1993
Resolved
PASSENGERS ARE PROHIBITED FROM THE SUN DECK UNTIL TEMPORARY REPAIRS ARE COMPLETED ON THE STARBOARD STACK.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Engineering
Issued 29 October 1993
Resolved
A TEMPORARY REPAIR TO THE STARBOARD STACK SHALL BE COMPLETED PRIOR TO 15NOV93. THIS REPAIR SHALL INCLUDE THE REMOVAL OF ALL PORTIONS OF THE STARBOARD MOVABLE STACK AND EXTENSION OF THE FIXED STACK TO NOT LESS THAN 9FEET ABOVE THE SUN DECK LEVEL.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Fire Fighting
Issued 8 October 1993
Resolved
PROVE PROPER OPERATION OF FSD # 4, 5, 7, 14, 36, 37, 38, 40, 48 AND 29.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Documentation
Issued 8 October 1993
Resolved
PROVIDE MARINE DOCUMENT WITH CURRENT RENEWAL STICKER ATTACHED.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Navigation
Issued 12 April 1993
Resolved
RENEW STEERING REACH ROD AND VERIFY STEERING RAM TO STOP DISTANCES. NEW STEERING REACH ROD TO BE APPROVED BY ABS
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Fire Fighting
Issued 24 October 1992
Resolved
EMERGENCY FIRE PUMP SUCTION DUPLEX STRAINER WOULD NOT SHIFT.
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Fire Fighting
Issued 24 October 1992
Resolved
FSD #14 AND #36 WOULD NOT SHUT WHEN CONTROLS WERE ACTIVATED.
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Engineering
Issued 21 September 1992
Resolved
Pemanently repair exhaust leaks to stbd boiler uptake and casing.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Engineering
Issued 21 September 1992
Resolved
Submit for approval to MSO New Orleans, proposed plans for permanent repairs to stbd boiler uptake and casting.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Engineering
Issued 25 January 1992
Resolved
General condition of machinery spaces indicate lack of good housekeeping habits. Oil and grease has been allowed to accumulate in, on, and around engine room equipment. Wireways also have biult up oily residue. All excess oil, grease and dirt is to be cleaned and spaces will be maintained.
Condition: Unknown
Due 25 February 1992
Resolved 10 February 1992
Electrical
Issued 25 January 1992
Resolved
Maintain temporary start and control batteries for emergency generator. NiCad batteries to be tested & replaced as necessary. Emergency generator control system to be separated from Ni Cad system. New control system to be submitted for approval.
Condition: Unknown
Due 25 January 1992
Resolved 25 January 1992
Engineering
Issued 25 January 1992
Resolved
Repair or remove high steam pressure alarms on port and starbd boilers. Ifremoved or used for other purposes, automated test procedure is to be modified and submitted to OCMI for approval.
Condition: Unknown
Due 25 February 1992
Resolved 10 February 1992
Electrical
Issued 28 October 1991
Resolved
INSTALL A GRAND FAULT PROTECTION DEVICE NEAR THE SAUNAS ELECTRIC HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Electrical
Issued 28 October 1991
Resolved
INSTALL A FUSED DISCONNECT SWITCH IMMEDIATELY ADJACENT TO THE SAUNA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Navigation
Issued 28 June 1991
Resolved
MAKE AND MAINTAIN TEMPORARY COMMUNICATIONS BETWEEN PILOT HOUSE AND ENGINE ROOM DURING TRANSIT FROM GREENVILLE, MS TO MEMPHIS, TN. REPAIRS TO ENGINE ORDER TELEGRAPH TO BE COMPLETED IN MEMPHIS, TN PRIOR TO FURTHER SAILING ANDNOT LATER THEN 01JUL91. REPAIRS TO THE SATISFACTION OF THE MARINE INSPCTR.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Fire Fighting
Issued 10 May 1991
Resolved
Make repairs to closing mechanisim of fire door closures on doors #49, 7 & 6.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Fire Fighting
Issued 10 May 1991
Resolved
Install latch hardware on fire doors to crew's mess._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Lifesaving
Issued 10 May 1991
Resolved
make repairs to rescue boat gun'l port side in way of oarlock.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Documentation
Issued 4 February 1991
Resolved
SUBMIT FIRE CONTROL PLAN FOR REVIEW AND APPROVAL. PLAN IS TO BE SUBMITTED TO COMDT (G-MSC) VIA [name withheld]. A RED LINED PLAN IS TO BE MAINTAINEDIN THE WHEELHOUSE UNTIL THIS ITEM IS COMPLETED._x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
REMOVE PLASTIC WIRE TIES FROM WIREWAYS IN CHEMICAL STORAGE AREA AND CALLIOPE BAR OVERHEAD. PROVIDE METAL BANDING AS REQUIRED BY IEEE45._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH PORT AND STBD FWD SUPPLY FANS IN MACHINERY SPACE. REMOVE TEMPORARY HEATER WIRED IN TO STBD FWD VENT FAN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991
Resolved
FABRICATE AND INSTALL GUARD TO PREVENT DAMAGE TO FLAME SCANNER AND SMOKE INDICATORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991
Resolved
PROVIDE A COPY OF THE ABS REPORT DETAILING REPAIRS COMPLETED ON THE PORT PITTMAN ARM, TO INCLUDE REPAIR AND STRESS RELIEVING DETAILS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Fire Fighting
Issued 4 February 1991
Resolved
SUBMIT FIRE LOAD CALCULATION FOR PADDLEWHEEL BAR AREA AND MAKE SAME AVAILABLE FOR INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
PROVIDE SAUNA HEATING ELEMENT DETAILS INCLUDING NAMEPLATE DATA SUCH AS UL APPROVAL AND SPACE SIZE RESTRICTIONS FOR REVIEW AND APPROVAL. SAUNA IS NOT TO BE USED UNTIL THIS ITEM IS COMPLETED AND APPROVED._x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
PROVIDE PROPOSAL FOR REDUCING CALCULATED FIRE LOAD IN GRAND SALOON. PROPOSAL TO BE SUBMITTED TO [name withheld] AT THE ABOVE CAPTIONED ADDRESS._x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
MAKE PERMANENT REPAIRS TO SINK DRAIN LINE WHERE SOFT PATCHED BELOW SINK IN GOLDEN ANTLER BAR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
CLEAN UP WIRING IN WAY OF NEW BEER BOX INSTALLATION PORT SIDE PADDLEWHEEL BAR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
REMOVE JURY RIGGED WIRING AND PROPERLY WIRE SODA MACHINE IN CREWS MESS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
RENEW DOOR HANDLE ON DOOR JUST AFT OF WTD #3._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
PROVIDE RECEPTACLE COVERS AND/OR JUNCTION BOX COVERS FOR OPEN BOXES IN GOLDEN ANTLER BAR, LIQUER STORAGE ROOM, AND HOTEL OFFICE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
REMOVE PERMANENT EXTENSION CORD BELOW SINK IN GOLDEN ANTLER BAR AND MAKE PERMANENT WIRING CONNECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
MAKE ALTERATIONS TO GRAND SALOON TO REDUCE CALCULATED FIRE LOAD BELOW REGULATORY REQUIREMENTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Documentation
Issued 4 February 1991
Resolved
IN LIEU OF WITNESSED SEA TRIALS, MAKE DECK AND ENGINEERS LOG AVAILABLE FOR INSPECTION AT NEXT NEW ORLEANS PORT CALL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Documentation
Issued 4 February 1991
Resolved
PROVIDE WASTE DISPOSAL PLAN WHICH ADDRESSES DISPOSAL OF SOLID WET AND DRY WASTES. INCLUDE PIPING PLAN IF GARBAGE DISPOSAL IS TO BE UTILIZED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Fire Fighting
Issued 4 February 1991
Resolved
AQDJUST AND PROVE OPERATION OF FIRE SCREEN DOORS #36 AND 39._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
REPAIR AND PROVE OPERATION OF GENERAL ALARM BELLS IN WAY OF STATEROOMS 130,228, 393, 404, ONE NEAR GAZEBO ON OB DECK, HOTEL SERVICES DESK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Construction/Loadline
Issued 4 February 1991
Resolved
REPAIR LEAKING HAND HYDRAULIC PUMPS FOR #1 WTD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
REMOVE PLASTIC WIRE TIES AND PROVIDE METAL BANDING FOR CABLES IN OVERHEAD OF VIDEO ROOM. PROVIDE COVER FOR EXPOSED JUNCTION BOX._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
REPAIR DRAIN AND CLEAN CREWS WASHING MACHINE ROOM NEAR CREWS MESS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991
Resolved
PROVIDE DRAWINGS, STRESS CALCULATIONS, AND REPAIR PROCEDURES FOR MODIFICATIONS AND REPAIRS OF THE PADDLEWHEEL. 46 CFR 71.55-1 & 46 CFR _x001C_ 71.65-15._x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991
Resolved
SUBMIT PLANS TO COMDT (G-MSC) VIA [name withheld] FOR APPROVAL OF THE BOILER CONTROL AND COMBUSTION MANAGEMENT CONTROL. 46 CFR 62.20-1_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991
Resolved
PREPARE AND SUBMIT TO COMDT (G-MTH) VIA [name withheld] BOILER CONTROL AND MANAGEMENTTEST PROCEDURES FOR MODIFIED SYSTEM, TO INCLUDE INFORMATION REQUIRED BY 46 CFR 61.40._x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
LABEL SWITCHES IN EMERGENCY SWITCHBOARD NO. 1 LOCATED IN EMERGENCY DIESEL GENERATOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991
Resolved
IDENTIFY AND MARK EMERGENCY LIGHTS THROUGHOUT VESSEL IN VARIOUS LOCATIONS. DEMONSTRATE OPERATION OF ALL EMERGENCY LIGHTS TO A CG INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Navigation
Issued 7 December 1990
Resolved
REPAIR AND PROVE OPERATION OF STEERING GEAR POWER FAILURE ALARM INDICATOR LIGHT. 46 CFR 113.43_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1990
Resolved 7 December 1990
Electrical
Issued 7 December 1990
Resolved
REMOVE PLASTIC WIRE TIES AND PROVIDE METAL BANDING FOR CABLES IN THE OVERHEAD; STARBOARD PROMENADE DECK. 46 CFR SUBCHAPTER J AND IEEE 45._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1990
Resolved 7 December 1990
Fire Fighting
Issued 7 December 1990
Resolved
REMOVE FIRE SCREEN DOOR HOLD BACK HOOKS, PROVIDE DOOR CLOSURES, PROVIDE DOOR LATCHES (LOCKSETS), AS REQUIRED AND PROVE OPERATION OF ALL FIRE SCREENDOORS. 46 CFR 72.05-25_x001C_ _x001C_
Condition: Unknown
Due 7 December 1990
Resolved 7 December 1990
Fire Fighting
Issued 7 December 1990
Resolved
PROVIDE FIRE CONTROL PLAN THAT REFLECTS CURRENT CONFIGURATION OF THE VESSEL. 46CFR 78.45_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1990
Resolved 7 December 1990
Accommodation/Occupational Safety
Issued 13 April 1990
Resolved
PROVIDE EVIDENCE THAT THE INSTALLED CEILING FANS MET THE REQUIREMENTS OF 46 CFR SUBCHAPTER "J". THIS IS TO BE SUBMITTED TO MSO NEW ORLEANS, LA. (46CFR 111-105)
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Fire Fighting
Issued 13 April 1990
Resolved
REPAIR OR REPLACE FIRE SCREEN DOOR #34 & #36 THAT MEET THE CLEARANCES SPECIFIED IN 46 CFR SUBCHAPTER "H". ALL OTHER FIRE SCREEN DOOR ARE TO BE EXAMINED AND REPAIRED OR REPLACED AS NECESSARY.( 46CFR72.05-25 )
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Engineering
Issued 13 April 1990
Resolved
MAKE REPAIRS TO PORT AND STBD BOILER BURNER CONE OPENINGS AND BURNER FRONT REFRACTORIES AS PER BOLIER MANUFACTURERS SPECIFICATIONS OR PROVIDE EVIDENCETHAT THE EXISTING CONFIGURATION IS ACCEPTABLE. (46 CFR 61.01)
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Engineering
Issued 19 March 1990
Resolved
Conduct proper preventative maintenance to minimize clinker formation in boiler fireboxes, promulgate, and post instructions in the fire room for crew to use regarding frequency of clinker removal and cleaning of burner nozzle and when firemen should call for advice from a licensed engineer.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990
Resolved
Otain configuration of burner throat from boiler manufacturer and verify that shape of port boiler burner throat is correct to the satisfaction of the attending Coast Guard inspector.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Accommodation/Occupational Safety
Issued 25 January 1990
Resolved
SUBMIT MATERIAL SPECIFICATIONS FOR NEW FURNITURE INSTALLATION IN THE GRAND SALON, INCLUDING ALL NEW WICKER FURNITURE. SUBMIT MATERIAL SPECIFICATION FOR ALL NEW DRAPERY INSTALLATIONS. SPECIFICATIONS TO BE SUBMITED TO [name withheld] AT THE ABOVE CAPTIONED ADDRESS. 46 CFR 72.05-55
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Construction/Loadline
Issued 25 January 1990
Resolved
SHOW APPROVED PLANS FOR BULKHEAD INSTALLATION, UPPER PADDLEWHEEL BAR AND THEATRE AREA. 46 CFR 72.05-10
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Fire Fighting
Issued 25 January 1990
Resolved
SUBMIT FOR REVIEW AND APPROVAL PLANS FOR NEW INSTALLATION OF FIXED FIRE FIGHTING SYSTEM INSTALLED IN MAIN GALLEY. PLANS SHOULD INCLUDE SYSTEM SPECIFICATIONS, CONTROL LOCATIONS, INSTRUCTIONS, ELECTRICAL DIAGRAM. 46 CFR 76.05-20
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Engineering
Issued 27 November 1989
Resolved
RENEW STEM PACKING FOR FEED WATER REGULATOR VALVE, INBOARD OF PORT BOILER.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Electrical
Issued 27 November 1989
Resolved
REPAIR AND PROVE OPERATION OF THE STARBOARD SHIP SERVICE GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Electrical
Issued 1 September 1989
Resolved
MAKE REPAIRS TO AND DEMONSTRATE PROPER OPERATION OF VOLTAGE REGULATION SYSTEM ON VSL PORT SS TURBO GENERATOR. TEST OVERSPEED TRIP, LOW LUBE OIL TRIP, LOW LUBE OIL ALARM, ON VSL SS STBD. GENERATOR. DEMONSTRATE PROPER OPERATION OF # 1 AND 2 REVERSE POWER RELAYS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Accommodation/Occupational Safety
Issued 1 September 1989
Resolved
REMOVE WOODEN TRASH RECEPTACLES FROM VESSEL.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 17 May 1989
Resolved
PERMANANTLY MOUNT WIRING FOR SPEAKER IN ITEM D-6. 46 CFR77.05
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Electrical
Issued 17 May 1989
Resolved
REPAIR AND PROVE PROPER OPERATION OF SPEAKER, PORT SIDE, MAIN DECK, BOW AREA. 46CFR77.05
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Accommodation/Occupational Safety
Issued 17 May 1989
Resolved
RENEW INSULATION OF PIPES IN OVERHEAD ADJACENT TO FIRESTATION #62. UNTIL SUCH TIME THIS IS REPAIRED, MOP UP DRIPPING CONDENSATION WHICH ACCUMULATES ON DECK. 46CFR76.10-15
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
REPLACE BROKEN TIP RETAINER CHAIN FOR FIRE NOZZEL AT STATION #62. 46CFR76.10-10.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
FIX OR REPAIR NOZZLE TIP OF FIRE NOZZEL AT STATION #55. 46 CFR 76.10-10
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Electrical
Issued 17 May 1989
Resolved
REPAIR/REPLACE A BROKEN AUTOMATIC DOOR CLOSER FOR DOOR ADJACENT TO THE BEAUTY SHOP. 46 CFR 72.05-25
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Accommodation/Occupational Safety
Issued 17 May 1989
Resolved
REPAIR/REPLACE THE DAMAGED INSULATION OF A "HOBART" FOOD STORAGE UNIT IN THE GALLEY. 46 CFR 71.30-10.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Electrical
Issued 16 February 1989
Resolved
REPAIR OR REPLACE SWITCHBOARD FREQUENCY METER. 46 CFR 111.30-25 (E) (2).
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Accommodation/Occupational Safety
Issued 2 December 1988
Resolved
REPAIR LATCH AND KNOB MECHANISM TO HEAD, IN PILOTHOUSE, OR DISABLE SO AS TOPREVENT SOMEONE FROM LOCKING THEMSELF IN. 46CFR71.30-5
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Electrical
Issued 2 December 1988
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR AUTOMATIC CIRCUIT BREAKER. (EMERGENCY DOES START AUTOMATICALLY, BUT THE CIRCUIT BREAKER MUST BE CLOSEDMANUALLY.
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Navigation
Issued 2 December 1988
Resolved
REPAIR TELEGRAPH FAILURE ALARM ON BRIDGE. (RESET BUTTON STUCK; HORN NOT MOUNTED; ELECTRIC UNIT NOT PROPERLY MOUNTED; AND BULB BURNED OUT AND/OR WIRING MALFUNCTION) 46CFR77.05
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Documentation
Issued 2 December 1988
Resolved
PROVIDE COPY OF CCGD8 (MMT) APPROVAL LETTER OF 9 FEB. 84 WHICH APPROVES TRIM AND STABILITY BOOK REVISION OF 27 JAN 84 (WHICH SUPERCEEDS BOOKLET OF 23 JULY 76) 46CFR PART 170 SUBPART C AND D
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Navigation
Issued 22 November 1988
Resolved
DUE TO A STEERING CASUALTY ON 22NOV88, SUBMIT A PROPOSAL TO THE COGNIZANT OCMI THAT WOULD PRECLUDE THE HAPPENING OF A SIMILAR CASUALTY OF THE STEERING SYSTEM. 46CFR71.40-1
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Fire Fighting
Issued 2 September 1988
Resolved
REMOVE OR HYDRO OXYGEN BOTTLE IN EMERGENCY EQUIPMENT LOCKER #1.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Engineering
Issued 2 September 1988
Resolved
REPLACE RELIEF VALVE TO FWD (FIRE ROOM) AIR RECEIVER.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Electrical
Issued 2 September 1988
Resolved
PROVIDE COVER TO PORT CHILLER CONTROL COVER.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Fire Fighting
Issued 2 September 1988
Resolved
REMOVE FLAME SAFETY LAMPS AND REPLACE WITH OXYGEN 1 COMBUSTIBLE GAS INDICATORS NVIC 12-86.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Electrical
Issued 2 September 1988
Resolved
REMOUNT PA SPEAKER IN FORWARD CREW QUARTERS.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Documentation
Issued 2 September 1988
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION ON BOARD VESSEL.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Fire Fighting
Issued 2 September 1988
Resolved
REPACK THE FOLLOWING VALVES: #35 AND #46 FIREMAIN, AND STAND BY FIRE PUMP VALVE.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Engineering
Issued 2 September 1988
Resolved
REPACK/REPAIR INBOARD RIVER WATER SERVICE PUMP.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Electrical
Issued 2 September 1988
Resolved
LABEL GALLEY LIGHTING DISTRIBUTION PANELS.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Fire Fighting
Issued 2 September 1988
Resolved
REPLACE FIRE INSULATION INWAY OF AFT FIRE ROOM BLK (LOWER HALF).
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Engineering
Issued 2 September 1988
Resolved
REPLACE/REPAIR LAGGING IN FIRE ROOM AS NEEDED.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Documentation
Issued 20 May 1988
Resolved
PROVIDE 46 CFR PARTS 41-69, PARTS 70-89, AND PARTS 90-139.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Accommodation/Occupational Safety
Issued 20 May 1988
Resolved
CAPTAIN TO MAKE SANITATION INSPECTIONS AS REQUIRED BY 46 CFR 71.45, AND LOG SAME IN THE VESSEL'S DECK LOG.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Accommodation/Occupational Safety
Issued 20 May 1988
Resolved
HAVE GALLEY, SERVING PANTRIES, FOOD STORAGE SPACES AND BAR AREAS, AVAILABLE FOR SANITATION INSPECTION.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Lifesaving
Issued 20 May 1988
Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIRS TO RESCUE BOAT.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Fire Fighting
Issued 20 May 1988
Resolved
CONDUCT 12-YEAR HYDROSTATIC TEST ON CO2 BOTTLES FOR GALLEY'S FIXED CO2 SYSTEM.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Engineering
Issued 20 May 1988
Resolved
PROVE HIGH WATER AND LOW WATER TRIPS FOR STARBOARD BOILER.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Construction/Loadline
Issued 13 November 1987
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE VSL'S NO #3 (AFT) WATER TIGHT SLIDING DOOR
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Construction/Loadline
Issued 13 November 1987
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF THE VESSELS NUMBER 3 (AFT) WATERTIGHT SLIDING DOOR.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Accommodation/Occupational Safety
Issued 1 May 1987
Resolved
FIX SUPPLY FAN FOR ENGINEERING WORKSHOP SO THAT IT WILL SHUT OFF WITH REMOTE STOP FOR ENGINE ROOM VENTILLATION.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Electrical
Issued 1 May 1987
Resolved
PROVIDE COVER FOR ELECTRICAL PANEL IN PURSERS OFFICE.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Fire Fighting
Issued 1 May 1987
Resolved
PROVE AUTOMATIC OPERATION OF FIRE SAFETY SOOR #37. DOOR PRESENTLY OPERABLEBUT IT HANGS UP.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Accommodation/Occupational Safety
Issued 1 May 1987
Resolved
INSTALL CLOSING DEVICES FOR VENTS TO BOILER ROOM WHERE NOT INSTALLED. REPAIR AND PROVE PROPER OPERATION OF CLOSING DEVICES WHERE THEY ARE INSTALLES.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Unknown
Issued 10 October 1986
Resolved
REMOVE OR PROPERLY MOUNT THE GUAGE ON THE CHILLED WATER UNIT IN THE AFT SPACE LOWER LEVEL.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Fire Fighting
Issued 10 October 1986
Resolved
PROVIDE PROPER BRACKETS FOR ALL ON BOARD FIRE EXTINGUISHERS AS NEEDED AT DIFFERENT FIRE STATIONS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Construction/Loadline
Issued 10 October 1986
Resolved
PROVIDE PROPER SAFETY CHAINS ON THE OPEN SPACE IN THE RAIL ON THE MAIN DECKPORT SIDE AMIDSHIPS.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Electrical
Issued 10 October 1986
Resolved
PROPERLY SECURE THE STACKED DRYERS IN THE CREWS LUANDRY TO PREVENT THEIR MOVEMENT AND FALLING.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Electrical
Issued 10 October 1986
Resolved
PROPERLY ATTACH THE ARMORED CABLE TO THE ELECTRIC HEATERS IN THE FIRE ROOM.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Electrical
Issued 10 October 1986
Resolved
REMOVE THE DEAD END CABLE IN THE CREWS GALLY TO ITS SOURCE OF POWER OR PROPERLY TERMINATE IN A JUNCTION BOX.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 10 October 1986
Resolved
PLACE THE LUBE OIL STORED ON THE MAIN DECK FORWARD PORT SIDE IN A PROPER AREA.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Navigation
Issued 22 August 1986
Resolved
REPLACE REDUCER IN HYDRAULIC LINE TO RELIEF VALVE IN THE PORT STEERING SYS-TEM.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Fire Fighting
Issued 15 August 1986
Resolved
CONDUCT TESTS (OR PROVIDE EVIDENCE OF SUCH TESTING) TO ENSURE THAT THE FIREPUMPS DO NOT REQUIRE RELIEF VALVES AS SET FORTH IN 46 CFR 76.10-5(D).
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Documentation
Issued 15 August 1986
Resolved
PROVIDE ON BOARD THE VESSEL A SIGNED STABILITY LETTER OR CERTIFIED COPY OF SUCH LETTER.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
CHANGE THE STATION BILLS TO REFLECT THE REMOVAL OF NO. 2 RESCUE BOAT.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986
Resolved
REMOVE THE HOLD BACK HOOKS FROM THE DOORS ON ALL A AND B BULKHEADS.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
MAKE CHANGES TO THE MOUNTED FIRE AND SAFETY PLANS TO REFLECT ALL BULKHEADS ON THE VESSEL.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986
Resolved
PROVIDE A PROPER FILLER MATERIAL FOR THE EXPLOSION PROFF "Y" FITTING IN THELIGHTING CIRCUT IN THE PAINT LOCKER.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Lifesaving
Issued 15 August 1986
Resolved
PROPERLY ATTACH THE WEAK LINK FOR NO. 2 INFLATABLE LIFE RAFT STBD SIDE.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986
Resolved
REPAIR OR REPLACE THE RETURN SPRINGS ON THE FUEL OIL TANK SOUNDING TUBES TO FACILITATE AUTOMATIC CLOSING OF THE GATE VALVES.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Fire Fighting
Issued 15 August 1986
Resolved
PROPERLY ADJUST THE AUTOMATIC CLOSURES ON FIRE DOORS NO. 22 & 26.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986
Resolved
PROVIDE PROPER LIGHT IN THE LIQUOR LOCKER.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 28 March 1986
Resolved
DEMONSTRATE PROPER OPERATION OF WRONG DIRECTION ALARM.
Condition: Unknown
Due 28 March 1986
Resolved 28 March 1986
Documentation
Issued 22 November 1985
Resolved
PROVIDE VESSEL DOCUMENTATION FOR COAST GUARD EXAMNATION.
Condition: Unknown
Due 22 November 1985
Resolved 22 November 1985
Construction/Loadline
Issued 22 November 1985
Resolved
REPAIR AND PROVE PROPER OPERATION OF NUMBER ONE WATERTIGHT DOOR.
Condition: Unknown
Due 22 November 1985
Resolved 22 November 1985
Navigation
Issued 22 November 1985
Resolved
REPLACE EXTERNAL SEAL ON STARBOARD STEERING HYDRALIC RAM.
Condition: Unknown
Due 22 November 1985
Resolved 22 November 1985
Unknown
Issued 19 August 1985
Resolved
REMOVE THE COMBUSTIBLES STOWED IN THE FIRE ROOM.
Condition: Unknown
Due 19 August 1985
Resolved 19 August 1985
Fire Fighting
Issued 19 August 1985
Resolved
PROVIDE KICKOUT PANELS ON THE DOORS OF BOTH CO2 STORAGE SPACES FOR THE FIXED CO2 SYSTEM OR MAKE MODIFICATIONS AS NECESSARY TO FACILITATE THE DOORSOPENING OUT RATHER THAN IN.
Condition: Unknown
Due 19 August 1985
Resolved 19 August 1985
Fire Fighting
Issued 19 August 1985
Resolved
REMOVE THE HOLD BACK HOOKS FROM ALL FIRE SAFETY DOORS AND DOOR STOPS.
Condition: Unknown
Due 19 August 1985
Resolved 19 August 1985
Unknown
Issued 19 August 1985
Resolved
PROPERLY STOW THE MATERIALS IN THE CLOSET LOCATED UNDER THE STAIRWELL OFF THE PASSAGEWAY IN THE VICINITY OF CREWS QUARTERS PORTSIDE AFT.
Condition: Unknown
Due 19 August 1985
Resolved 19 August 1985
Fire Fighting
Issued 19 August 1985
Resolved
PROVIDE A METHOD OF SECURING SHUT THE HOSE PORTS ON ALL THE FIRE DOORS THATHAVE HOSE PORTS PROVIDED.
Condition: Unknown
Due 19 August 1985
Resolved 19 August 1985
Fire Fighting
Issued 14 August 1985
Resolved
MAKE PERMANENT REPAIRS TO THE ELECTRIC CLOSING MECHANISM FOR THE SLIDING FIRE DOOR ON THE OBSERVATION DECK, STARBOARD GALLERY. UNTIL SUCH REPAIRS ARE MADE, THE MASTER SHALL ENSURE THAT A CREWMEMBER IS ASSIGNED TO CLOSE THAT DOOR AT ALL FIRE DRILLS.
Condition: Unknown
Due 14 August 1985
Resolved 14 August 1985
Fire Fighting
Issued 14 February 1985
Resolved
INSTALL MOTOR OPERATED COVERS AT RADIATOR THAT CLOSE AUTOMATICALLY UPON RELEASE OF CO2 INTO EMERGENCY ROOM TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO 29 APRIL 1985.
Condition: Unknown
Due 14 February 1985
Resolved 14 February 1985
Unknown
Issued 14 February 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, MISSISSIPPI QUEEN, DN574200
Condition: Unknown
Due 14 February 1985
Resolved 14 February 1985
Electrical
Issued 10 August 1984
Resolved
(CONT. E1) OR ANCHORED AT THE DISCRATION OF THE MASTER UNTIL A TUG OF SUFFICIENT HORSE POWER IS NEAREST PORT FOR REPAIRS. THE ABOVE REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGIZANT OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984
Resolved
THE FOLLOWING DEFICIENCIES PRETAIN TO THE VESSEL MISSISSIPPI QUEEN, 574200 AND ARE TO BE COMPLIED BY 15AUG84
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Electrical
Issued 10 August 1984
Resolved
MAKE PERMANENT REPAIRS TO VESSEL STARBOARD SHIP SERVICE GENERATOR REPAIRS TO BE COMPLETED UPON RETURN TO NEW ORLEANS, LA. AND BEFORE DEPARTURE BUT INNO CASE LATER THAN 15AUG84 IF VESSEL PORT SHIP SERVICE GENERATIOROR THE EMERGENCY GENERATOR BECOMES INOPERABLE VESSEL SHALL BE NOSED IN TO THE BANK
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 24 April 1984
Resolved
EXAMINED & TESTED TEMP REPAIRS TO RUDDER LINK ALL EXAM & TESTS SAT. NOTIFI-ED NEWMI OF ARRIVAL TIME PERM. REPAIRS TO BE COMPLETED
Condition: Unknown
Due 24 April 1984
Resolved 24 April 1984
Electrical
Issued 7 May 1982
Resolved
REPLACE LIGHT BULBS IN BOILER (FIRE) ROOM LIGHTING FIXTURES.
Condition: Unknown
Due 21 May 1982
Resolved 7 May 1982
Engineering
Issued 7 May 1982
Resolved
DEMONSTRATE PROPER OPERATION OF THE FWD DRUM SAFETY AND THE SUPERHEATER SAFETY VALVES ON THE PORT MAIN BOILER.
Condition: Unknown
Due 21 May 1982
Resolved 7 May 1982