Inspection history · 43
16 February 2007
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2879460
15 September 2000
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 824769
23 September 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347610
20 August 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395015
23 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 179828
14 October 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 522584
26 August 1997
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1451223
23 November 1996
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 875163
8 November 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443772
19 September 1995
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1419497
13 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 470857
5 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 203787
5 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 752185
11 August 1994
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 865490
16 July 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 440976
12 February 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 459480
1 November 1993
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 443728
1 October 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 498718
14 September 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 834628
21 July 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 453307
2 July 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 107284
21 February 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 510332
19 November 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 492357
7 October 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 489362
19 August 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1269628
1 November 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 936442
7 September 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907451
24 August 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 905412
12 August 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 519599
24 January 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 521886
4 August 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1207142
7 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 487537
16 April 1989
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 477322
20 October 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 887337
19 October 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886636
20 September 1988
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1042243
26 August 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1349077
29 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 440125
27 August 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342434
27 January 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1011437
29 September 1986
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1005284
2 December 1985
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 985771
20 August 1985
COI Inspection · Credit Drydock
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 985754
Construction/Loadline
Issued 23 September 1999
No resolution recorded
PRESENT VESSEL FOR COMPLETE ISE, CTI AND HULL EXAM TO INCLUDE COMPLETE GAUGINGS OF DECK, SIDES AND BOTTOM PRIOR TO ANY OPERATION INVOLVING THE LOADING, DISCHARGING OR TRANSPORT OF ANY CARGO.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Deck/Cargo
Issued 23 September 1999
No resolution recorded
VESSEL TO UNDERGO COMPLETE TOPSIDE RE-EXAM INCLUDING P/V's, THERMAL FLUID HEATER AND CARGO PUMP ENGINES PRIOR TO RESUMING OPERATIONS INVOLVING THE LOADING, DISCHARGING OR TRANSPORTING OF CARGO.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Deck/Cargo
Issued 26 August 1997
Resolved
Repair low fuel oil pressure alarm switch on Thermal Fluid Heater and proveproper operation of alarm.
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Deck/Cargo
Issued 26 August 1997
Resolved
Clean debris from containment area at the forward rake.
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Electrical
Issued 26 August 1997
Resolved
Repair junction box cover in the area of the forward rake.
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Electrical
Issued 26 August 1997
Resolved
Install blanks in the open areas of the electrical distribution panal.
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 26 August 1997
Resolved
Replace hatch gaskets on No.1, 4 & 6 wing voids starboard side and No.2, No.4 gaskets on port wing voids.
Condition: Unknown
Due 26 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 8 November 1996
Resolved
FRACTURED WELDS IWO FWD BULKHEAD OF BOW BOX FAMES.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Documentation
Issued 8 November 1996
Resolved
CARGO TRANSFER PROCEDURES IN POOR CONDITION (WORN) AND MISSING INDEX.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 24 August 1990
Resolved
CONDUCT INTERNAL STRUCTURE EXAMINATION PRIOR TO NEXT LOADING OR NOT LATER THAN 10SEP90.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Engineering
Issued 4 August 1989
Resolved
CONDUCT AN OPERATIONAL TEST OF THE THERMAL FLUID HEATER IN THE PRESENCE OF A CG MARINE INSPECTOR WITH THE FIXED CO2 SYSTEM RECONNECTED.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Engineering
Issued 4 August 1989
Resolved
MAKE AVAILIABLE APPROVED HEATER INSTRUCTIONS/PROCEDURES BOOKLET OR CG STAM-PED APPROVED TEST PROCEDURES (CHECKLIST) TO THE ATTENDING CG MARINE INSPEC-TOR PRIOR TO THE OPERATION OF THE THERMAL FLUID HEATER. REF: 46 CFR 61.30-20.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Electrical
Issued 26 August 1988
Resolved
PLACE BLANK IN DISTRIBUTION PANEL IN GENERATOR HOUSE.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Deck/Cargo
Issued 26 August 1988
Resolved
MAKE TWO STRIPPING TANK ULLAGE FLAME SCREENS VAPOR TIGHT AROUND EDGES.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Electrical
Issued 26 August 1988
Resolved
RENEW WIRING TO GENERATOR ALARM LIGHT OUTSIDE OF GENERATOR HOUSE.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988