MAURY USCG vessel records
← All vessels

KIRBY 23730B

Built
1977
Last inspected
28 June 2011
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 28 June 2011
…with no type recorded21
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1985–2011)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-49192

Documentation record

Tonnage as PSIX records it1521 - Regulatory (Subpart C or D), Gross Ton
1521 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 76 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 11 other vessels inspected with it; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 76

28 June 2011 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4125056
9 April 2010 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3712838
4 January 2010 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3658269
28 May 2009 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3488564
2 May 2009 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3466083
16 October 2008 Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3646749
7 October 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3340089
28 April 2008 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3194041
28 April 2008 Permit to Proceed
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3194304
8 April 2008 Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3178856
24 March 2008 Examination of Repairs · Cargo Tank Internal · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3166700
31 October 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3109856
18 May 2007 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2933991
4 May 2007 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2922488
29 March 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2897769
7 December 2006 COI Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2835709
13 June 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2678413
11 April 2006 Damage Survey · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2622411
23 March 2006 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2606049
9 January 2006 Damage Survey · Permit to Proceed
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2563408
27 May 2005 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2369831
25 April 2005 Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2340574
29 December 2004 Internal Structural Exam · Hull Examination · MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2262985
29 March 2004 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2033379
12 February 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005175
11 February 2004 Drydock Extension
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2004409
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1985762
27 February 2003 Periodic Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1750165
13 January 2003 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1729572
17 December 2001 COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1474040
8 February 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369996
8 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 76387
16 June 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 110117
16 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 493885
30 December 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 812398
21 December 1999 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 809621
23 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 800348
4 January 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 129873
20 March 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464084
4 December 1996 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1458356
20 June 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 479439
29 January 1996 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1193310
26 July 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 501673
10 May 1995 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 901546
17 March 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1136868
17 March 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1139078
15 March 1995 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1416092
12 August 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174764
28 April 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859113
2 February 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396023
30 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 472939
22 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417501
2 April 1993 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1146720
26 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 465125
8 June 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261770
15 March 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 480457
20 May 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 916425
20 April 1991 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 917628
12 April 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224564
16 March 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 504046
17 April 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213431
22 June 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896505
12 May 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349259
30 November 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 491225
19 September 1988 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350150
18 May 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1043495
20 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 473428
25 August 1987 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1031212
2 June 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1031703
22 May 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010348
20 May 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 484243
27 January 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 525476
24 November 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 470226
6 November 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009069
16 May 1986 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 991853
12 December 1985 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 995072

Deficiency record · 28

Construction/Loadline › Hull › Hull Plating
Issued 4 January 2010 No resolution recorded
12 '' fracture in the stern void, port side corner knuckle, applied epoxy patch inside and out
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2010 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 May 2009 Resolved
There is a pin hole leak in the #2 cargo tank at the walking deck, into the #3 wing void.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 May 2009
Resolution: Conducted repair check. Examined welds and witnessed satisfactory air test of 18"''x18"x3/8"section of cargo tank side shell in way of #3 port wing void.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 28 April 2008 Resolved
Effect permanent repairs to 27 pin holes located across the cargo tank tops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2008
Resolution: Conducted repair check. Examined welds and witnessed satisfactory air tested welds of 17''x159''x5/16" of tank top on #1,#2,#3 Portcargo tank. 14.5''x 47.5''x5/16" of tank top on #3 port cargo tank. 25''x82.5''x5/16" of tank top on #3 and #4 port cargo t
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 24 March 2008 Resolved
3/4" and 1" hole in tank top of #4 port cargo tank, approximately 2" from centerline
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2008
Resolved 28 March 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 June 2006 Resolved
Provide satisfactory documentation to [name withheld]/Galveston that this vessel has operated in fresh water service at least 6 of the last 12 months. If the vessel has not been operated in fresh water service at least 6 of the last 12 months or satisfactory documentation cannot be provided, the vessel will be required to be inspected IAW the salt water intervals prescribed in 46 CFR 31.10-21(a)(1)
Action required: 705 - Other - as specified
Due 16 July 2006
Resolved 19 June 2006
Resolution: Fresh service verified for 6 of the last 12 months of service.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 June 2006 Resolved
COASTAL 2310 operated during a three month period after the COI expired before obtaining a new one.
Action required: 705 - Other - as specified
Resolved 13 June 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 June 2006 Resolved
COASTAL 2310 failed to have an annual exam conducted between 29 DEC 04 and 13 JUN 06
Action required: 705 - Other - as specified
Resolved 13 June 2006
Construction/Loadline › Hull › Hull Plating
Issued 11 April 2006 Resolved
Make temporary repairs to pinhole leak on the locking pin in the stbd stern void. Proceed to Houston Fuel Oil to off load cargo. Proceed to Channel View Shipyard to make permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2006
Resolution: Witnessed repairs.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 9 January 2006 Resolved
Issued PTP to allow vessel to transit directly to Southwest Shipyard in Texas for repair. Vessel has holes located in the tops of cargo tanks #1 p/s & #2 p/s in way of centerline. Permanent repairs to be made prior to conducting cargo operations. Vessel void spaces shall be monitored hourly and notification made to the cognizant OCMI if any changes to vessel conditions occur.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 23 March 2006
Resolution: Satisfactory repairs were made to the #1 and #2 p/s cargo tanks in way of centerline.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 27 May 2005 Resolved
Pinhole located in cargo tank bottom plate in way of #3 p/s cargo tanks at centerline.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2005
Resolution: 4'' x 4'' x 3/8" insert.
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2004 Resolved
Bottom plate wasted and holed in way of #5 stbd wing void.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2004
Resolution: 3'' x 10'' x 1/2" insert.
Construction/Loadline
Issued 8 February 2001 Resolved
REWELD BROKEN WELD ON TRUSS IN THE STERN VOID IN WAY OF THE PORT HATCH.
Condition: Unknown
Due 7 March 2001
Resolved 9 February 2001
Construction/Loadline
Issued 8 February 2001 Resolved
#4 PORT WING VOID HAD THE 3RD AND 4TH LONGITUDINAL TRIPPED.
Condition: Unknown
Due 7 March 2001
Resolved 9 February 2001
Construction/Loadline
Issued 8 February 2001 Resolved
REWELD CRACK ON TRUSS IN THE #2 PORT WING VOID IN WAY OF HATCH.
Condition: Unknown
Due 7 March 2001
Resolved 9 February 2001
Deck/Cargo
Issued 8 February 2001 Resolved
REPLACE ALL GATE, GLOBE AND ANGLE VALVES WITH THE RISING STEM TYPE EXCEPT VALVES IN TANKS AND IN ACCESSIBLE SPACES WHERE OPEN/CLOSED INDICATORS ARE PROVIDED AT THE REMOTE OPERATING STATION. ALL NON RISING STEM AND LEVER OPERATED VALVES SHALL BE FITTED WITH OPEN/CLOSED INDICATORS._x001C_
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Unknown
Issued 23 February 1999 Resolved
BARGE IS PROHIBITED FROM LOADING CARGO UNTIL AN INTERNAL STRUCTURAL EXAM ISCOMPLETED.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Fire Fighting
Issued 15 March 1995 Resolved
HAVE CO2 BOTTLE INSPECTED AND SERVICED PRIOR TO CONDUCTING CARGO DISCHARGE OPERATIONS.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Electrical
Issued 15 March 1995 Resolved
REMOVE OR PROPERLY SECURE DEAD END WIRES FROM CIRCUIT PANEL LOCATED IN THERMAL FLUID HEATER ROOM.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Deck/Cargo
Issued 15 March 1995 Resolved
CONDUCT THERMAL FLUID HEATER TEST PROCEDURES. PROCEDURES TO BE WITNESED BY MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Engineering
Issued 2 April 1993 Resolved
INSTALL FLAME GUARDS ON BOTTOM OF GENERATOR RACOR FUEL FILTERS.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Unknown
Issued 2 April 1993 Resolved
SHOW COMPLIANCE WITH NVIC 7-92, I.E., VESSEL RESPONSE PLAN.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Deck/Cargo
Issued 2 April 1993 Resolved
PRESENT THERMAL FLUID HEATER FOR INTERNAL INSPECTION.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Deck/Cargo
Issued 2 April 1993 Resolved
REPAIR INOPERATIVE THERMAL FLUID HEATER VISUAL ALARM INDICATOR, (ROTATING BEACON).
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Construction/Loadline
Issued 20 April 1991 Resolved
Make permanent repairs to the 6' by 3" crack along the STBD corner plate inway of the stern box. While in transit the stern box shall be examined every six (6) hours for water accumulation.
Condition: Unknown
Due 20 April 1991
Resolved 20 April 1991
Construction/Loadline
Issued 22 May 1987 Resolved
WELD INSIDE OF HOLE IN STERN SHELL PLATE TO OVERLAPPING DECK WRAPPER AND RENEW ONE CORNER BRACKET ON STBD SIDE IN THE BOW BOX VOID.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Deck/Cargo
Issued 22 May 1987 Resolved
CONDUCT OPERATIONAL TESTING OF ALL SAFETY DEVICES FOR THERMAL FLUID HEATER IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Construction/Loadline
Issued 22 May 1987 Resolved
CROP OUT RENEW ONE OVERHEAD TRANSVERSE CHANNEL ON TRUSS FRAME IN NO. 4 PORTAND IN NO. 4 STBD WIND VOIDS, AS MARKED.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Engineering
Issued 6 November 1986 Resolved
OPERATE THERMAL FLUID HEATER AND TEST ALL SAFETY DEVICES IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986

Recorded names · 1

COASTAL 2310-B (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record