Inspection history · 177
6 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6621044
14 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6244598
26 July 2017
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6243173
30 June 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6191631
23 June 2017
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6187724
15 May 2017
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6147414
30 March 2017
Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6114418
8 February 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6084447
8 February 2017
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6084687
17 December 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6059881
30 August 2016
MTSA Verification · Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5987251
10 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5873848
24 December 2015
Damage Survey · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5786746
23 December 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5803009
15 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5743634
26 September 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5733621
23 September 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5738618
17 August 2015
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5218579
3 June 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5156539
1 June 2015
Internal Structural Exam · DAPI Audit · Drydock Exam · Administrative Inspection · COI Inspection · MARPOL Annex I Examination · MARPOL Annex IV Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5141369
18 March 2015
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5086169
25 October 2014
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5022739
8 October 2014
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5001722
4 October 2014
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4998802
22 September 2014
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4989857
20 September 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4991164
31 July 2014
Deficiency Check · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex II Examination · Ballast Water Examination · Examination of Repairs · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4936656
27 September 2013
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4724447
21 June 2013
Annual Inspection · Internal Structural Exam · DAPI Audit · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4626755
13 May 2013
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4585263
8 May 2013
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4586104
7 May 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4603808
23 April 2013
Drydock Extension
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4591944
11 April 2013
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4567036
2 April 2013
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4565701
1 April 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4570271
20 July 2012
Annual Inspection · DAPI Audit · MTSA Verification · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4384580
10 May 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4307659
11 November 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4216124
12 October 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4172897
17 August 2011
MARPOL Annex VI Survey · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex IV Survey · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4104412
21 December 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3917860
13 May 2010
Ballast Water Examination · MTSA Verification · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3737288
10 March 2010
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3693198
22 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3684043
25 November 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3642717
19 November 2009
Annual Inspection · DAPI Audit · Administrative Inspection · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3651271
30 July 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3551000
8 July 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3535670
23 February 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3418869
31 July 2008
Hull Examination · Deficiency Check · Periodic Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3284737
1 July 2008
Drydock Extension · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3270987
24 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3218729
11 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3203483
21 March 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3182167
28 February 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3155421
27 January 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3137327
7 December 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3111415
19 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3064969
5 September 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3051782
5 September 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3072141
1 August 2007
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3015310
11 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2927912
21 February 2007
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2875138
20 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874835
19 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879965
6 December 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2835235
19 September 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2782076
18 September 2006
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2784446
18 July 2006
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2716721
23 February 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2591069
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2589862
21 November 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2565048
5 August 2005
Examination of Repairs
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2452085
28 April 2005
Hull Examination · Internal Structural Exam · COI Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2344518
13 April 2005
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2332958
12 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2332214
7 April 2005
MTSA/ISPS Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2339608
4 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2347371
28 March 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2320989
18 March 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2386444
4 June 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2088639
21 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1989649
14 November 2003
Administrative Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1955082
8 September 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1899669
28 August 2003
Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1890031
28 April 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1782286
10 April 2003
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1771566
4 February 2003
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1739868
12 November 2002
Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1704124
23 October 2002
Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1695134
22 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694635
22 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694829
23 July 2002
Administrative Inspection · Annual Inspection · In-Service Inspection · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1626236
6 June 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1627076
15 February 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1493522
9 May 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1362193
19 May 2000
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399381
13 March 2000
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047612
2 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 148495
11 August 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406544
15 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 801351
26 August 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1396983
8 July 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 794520
6 April 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1396906
21 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 111764
12 August 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460103
12 March 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 151043
12 March 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455452
17 November 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447645
5 November 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 858293
2 October 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468397
18 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87338
11 July 1996
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1090717
26 September 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 880733
9 September 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181377
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188234
7 September 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 25396
28 August 1995
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181006
16 September 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177853
11 August 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 168947
5 July 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1326441
17 August 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 6800
5 August 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356378
25 June 1993
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 846771
13 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101419
8 February 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149330
14 January 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 500909
25 December 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 157814
15 October 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261865
31 July 1992
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962336
11 October 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942734
17 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248959
15 July 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937668
14 June 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044872
27 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915642
6 November 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925197
25 June 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210285
2 June 1990
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243180
2 June 1990
Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1252329
7 December 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227386
1 November 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000130
24 October 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892809
20 January 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891671
12 January 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888029
5 January 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1351206
12 December 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209480
30 November 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897113
8 March 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028585
22 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332810
18 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328738
17 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332667
5 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018119
2 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325288
16 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317111
25 November 1987
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352563
5 November 1987
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320079
8 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330725
31 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021932
30 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021935
17 March 1987
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1327020
5 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310727
29 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315615
18 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987396
31 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994388
25 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984557
25 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980396
23 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980614
5 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980856
3 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284281
18 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980726
1 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975213
27 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279500
16 August 1983
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407191
27 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271846
29 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966878
11 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275743
Engineering › Generator (propulsion/auxiliary-electric) › Conductor
Issued 14 August 2017
Resolved
Vessel #1 FWD generator is not operational. Provide technician report and repair plan to satisfaction of attending marine inspector prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 August 2017
Resolved 17 August 2017
Resolution: Technician replaced defective diode within generator. ABS conducted verification tests on board and provided report. Marine Inspector attended vessel to verify funtionality of system.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2017
Resolved
Prior to movement provide class report attesting to the proper operation of the emergency curuit, all navigational equipment, and engine room machinery using #1 generator. Provide concurrent transit plan through class for transit from Mosaic Uncle [name withheld] to repair facility, during daylight hours with escort tug of adequate horsepower and confirmation that repair facility has availability.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 May 2017
Resolved 16 May 2017
Resolution: Vessel provided satisfactory class report and transit plan adherent to requirements. All sat.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2017
Resolved
Prior to departure from LMR, provide marine surveyor report identifying root cause of fire, and class report attesting to proper repairs of generator, integrity and operation of the electrical circuit operation of #2 generator, proper installation of lagging and operation of auxiliary components. As well as full inventory of firefighting equipment on board, and replace as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2017
Resolved 24 May 2017
Resolution: Vessel provided class report meeting requirements. Generator replacement will be effected at Sector St. Pete's AOR.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 17 December 2016
Resolved
Vessel reported #1 steering electric amplifier malfunctioned during pre-arrival checks. Vessel required to have assist tug when transiting the river and prior to departure from port provide a class/tech report attesting to the repair and correct operation of the #1 steering pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2016
Resolved 18 December 2016
Resolution: Vessel was attended by technician from Sperry Marine and ABS Class surveyor. Feedback pot for the #1 steering repeat back unit was replaced, along with the coupling. Steering tests were conducted on the #1 and #2 steering units, all working satisfactory.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 May 2016
Resolved
Continuous breaker trip on aft generator main breaker. Repair to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Technician found grounded wire and repaired. Test Sat.
Engineering › Diesel Engine (auxiliary) › Block
Issued 24 December 2015
Resolved
Make repairs to forward generator to the satisfaction of attending Marine Inspector and Classification Society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Resolution: Owner rebuilt generator #1 prime mover.
Communications › Radio Communications › Satellite Communications Capability
Issued 4 October 2014
Resolved
Vessel reports that INMARSAT "C" is inop; 33CFR164.11(r)
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2014
Resolution: Recevied satisfactory test report and GMDSS maintenance license.
Fire Fighting › Fire Hydrants › Condition
Issued 31 July 2014
Resolved
Excessive leakage of all fire hydrant valve stem seals. 46 CFR 95.10-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 1 August 2014
Resolution: Some valves replaced others had the packing replaced.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 31 July 2014
Resolved
The reverse power relay on the #1 gen does not trip. Demonstrate proper operation. 46 CFR 111.12-11(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 12 August 2014
Resolution: 3rd party repair paperwork provided and rely was tested in all possible gen parallel conditions.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 April 2013
Resolved
Determine cause of power loss and make proper repair to the vessel's second steering pump.
Action required: 705 - Other - as specified
Resolved 4 April 2013
Resolution: Crew replaced a faulty 250 amp emergency tie breaker on the main switch board. Also received class report attesting to satisfactory repair completed to the steering system.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 March 2013
Resolved
Provide operational fuel shut-off valve for fuel day tank on port side of vessel (emergency valve). IAW 46CFR56.01-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2013
Resolution: Corrected.
Lifesaving › Lifebuoys › Not on Board
Issued 9 March 2013
Resolved
Provide quick release lifebuoys at port/stbd side of navigating bridge. IAW46CFR199.70(a)(1)(v).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2013
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Generator
Issued 23 July 2012
Resolved
Demonstrate proper operation of the forward generator (low lube trip, overspeed trip, and high temp alarm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2012
Resolution: Witnessed a satisfactory operational test of the forward generator. 46 CFR 1111.10-3
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 20 July 2012
Resolved
during operational testing of the port main diesel engine the low lube oil shutdown failed. Prove proper operation of low lube shutdown. 46 CFR 58.05-10
Due 13 June 2013
Resolved 3 September 2013
Resolution: Corrected.
Lifesaving › Launching Appliances › Falls
Issued 20 July 2012
Resolved
Provide certification of wire type and pull test of scuedge fitting. weight test lifeboats to 110% . Prior to sailing on an international voyage. 46 CFR 199.45(b)
Due 24 August 2012
Resolved 13 May 2013
Resolution: Witnessed lifeboat davit weight test of port and stbd davits. Added 4045 lbs of water to both boats for 10 minutes.
Electrical › Electric Generation Source (service) › Generator
Issued 20 July 2012
Resolved
Demonstrate parallel operation and reverse current power relay IRT 46 CFR 111.10-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2012
Resolution: Witnessed a satisfactory paralleling and reverse current relay test of generators
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 11 November 2011
Resolved
Properly repair Long Range Identification and Tracking System (LRIT) prior to International voyage and/or 30 days from issuing this CG-835; also provide a tech report for repairs completed to the LRIT; IAW 33 CFR 169.205.
Action required: 705 - Other - as specified
Due 11 December 2011
Resolved 15 November 2011
Resolution: Received tech service/report from Radio Holland.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 August 2011
Resolved
Renew cables for engine room fire dampers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2011
Resolution: Received email that Vessel Master [name withheld], Lic#172783, attests to the satisfactory renewal and test of fire damper cables.
Engineering › Generator (propulsion-electric) › Circuit Breaker (overload/over current protection)
Issued 17 August 2011
Resolved
Prove proper operation of Aft SSDG overspeed trip.
Due 17 September 2011
Resolved 23 August 2011
Resolution: Gaba Industrial Service repaired and satisfactorily tested overspeed trip.
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 August 2011
Resolved
Prove proper operation of hot water relief valve.
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 23 August 2011
Resolution: Master attested to satisfactory repair of relief valve.
Electrical › Electric Generation Source (service) › Panelboard
Issued 3 August 2010
Resolved
Repair or replace (5-8) alaram indictor panel lamps on the panel board located in the engine control room. 46 CFR 113.35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2010
Resolution: Alarm indicator panel tested to the satisfaction of the attending surveyor. Alarms tested allowing surveyor to witness visual and audible alarm indications.
Engineering › Sea-water System (primary cooling) › Pump
Issued 13 May 2010
Resolved
Renew as orginal the port reduction gear salt water cooling pump, iaw 46 CFR 58.10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2010
Resolution: Port reduction gear salt water cooling pump was replaced with reconditioned pump, tested at operational pressure of 15 psi for 10 minutes, pump considered satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 May 2010
Resolved
Repair or replace the stuffing tube on the aft bulkhead of the control room located starboard of the center line at the top of the bulkhead, due to not properly sealed for smoke/flame tight, iaw 46 CFR 92.07
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2010
Resolved 12 August 2010
Resolution: Received pics, from [name withheld] of the [name withheld], that showed the completion of the stuffing tube.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 November 2009
Resolved
Repair/replace high jacket water temp alarm on the emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Documentation › Markings/Placards › Warning Signs
Issued 19 November 2009
Resolved
Replace missing labels for remote fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Deck/Cargo › Holds/Tanks › Hatch
Issued 19 November 2009
Resolved
Repair starboard forward deck vent (missing dog) on bow of tug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 November 2009
Resolved
Repair Port forward deck vent (missing cover) on bow of tug.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 5 January 2010
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 19 November 2009
Resolved
Properly label and determine source for spare breaker on emergency switchboard located in the emergency generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Engineering › Fuel Oil Service System › Filter
Issued 19 November 2009
Resolved
Repair lube oil leaks on both maing propulsion engines L/O filter pods discharge valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Fire Fighting › Combustible Materials › Insulation
Issued 19 November 2009
Resolved
Replace missing A-60 insulation located in the paint locker, steering and emergency generator room.
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 19 November 2009
Resolved
Trouble shoot ground in emergency generator, breaker panel, 5# breaker for I.C. and navigation system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2009
Resolved
Replace light guard in engine room lowel level; aft of the port main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 5 January 2010
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 19 November 2009
Resolved
Properly label breaker panel in emergency generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2009
Resolved
Replace light cover guard located on the AFT main deck on the port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Fire Fighting › International Shore Connection › Bolts
Issued 19 November 2009
Resolved
Replace bolts and nuts for the international shore connection on both the port and starboard side located on the main deck; gasket missing on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 8 December 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 February 2009
Resolved
Remove all door holdback hooks on all fire boundary doors. SOLAS 74 amended Ch-II, Reg 9/4.2.2 & 2.3.4.1
Action required: 705 - Other - as specified
Due 1 September 2009
Resolved 1 September 2009
Resolution: Received confirmation from ship''''s captain that deficiency had been satisfied.
Lifesaving › Lifefloat › Serviceable
Issued 1 January 2009
Resolved
REPAIR OR REPLACE PORT LIFEBOAT WITH USCG APPROVED BOAT. IF REPAIRED PROVIDE REPAIR PROPOSAL TO COGNIZANT [name withheld] TO OPERATE ONCE A SERVICABLE SOLAS/USCG APPROVED LIFERAFT SUCCESSFULLY INSTALLED AND ACCEPTED BY COGNIZANT OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2009
Construction/Loadline › Structures › Superstructure
Issued 31 July 2008
Resolved
PROVIDE HEAT RSISTANT GASKET AROUND GALLEY "A" CLASS SLIDING WINDOW.
Due 15 October 2008
Resolved 8 November 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 31 July 2008
Resolved
ENSURE ALL BERTHING LIGHTS FOR BUNKS ARE OPERABLE.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Witnessed berthing lights were operable.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 31 July 2008
Resolved
PROVIDE SOLAS TRAINING MANUAL PER SOLAS 74/2001 CHAP III/35.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2008
Lifesaving › Rescue Boat Equipment › Painter
Issued 31 July 2008
Resolved
PROVIDE EQUIPMENT FOR RESCUE BOAT IN STBD BOAT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2008
Resolution: Witnessed rescue boat equipment placed in stbd lifeboat.
Lifesaving › Lifefloat › Retroreflective Material
Issued 31 July 2008
Resolved
PROVIDE TYPE III RETROFLECTIVE TAPE ON LIFEBOATS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2008
Personnel › Training › Launch Tender
Issued 31 July 2008
Resolved
POST LIFEBOAT LAUNCHING INSTRUCTIONS.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Witnessed launching instructions posted at stbd lifeboat.
Communications › Audible Communications › Bell
Issued 31 July 2008
Resolved
PROVIDE BELL MEETING COLREGS ANNEX III SEC 2.B.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Witnessed 12" bell provided.
Lifesaving › Lifefloat › Serviceable
Issued 31 July 2008
Resolved
PROVIDE PROOF OF IMPLEMENTATION & LIFEBOAT ANNUAL STRIPPING & CLEANING AND ISM/SMS PROCESS TO MEET 46 CFR 199190(F) FOR CREW MAINTENANCE CHECKS. PROVIDE COPY ON COMPANY CIRC.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Examined form established with monthly maintenance program to perform annual lifeboat stripping and cleaning. Boat was stripped and cleaned at the end of Nov 2008 - all sat.
Lifesaving › Lifefloat › Painter
Issued 31 July 2008
Resolved
PROVIDE 2 PAINTERS FOR LIFEBOATS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2008
Resolution: Painters provided in stbd boat. Port boat was removed at time of def check.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 31 July 2008
Resolved
PROVIDE UPDATED COMPASS DEVIATION TABLE FOLLOWING BARGE SHIPYARD.
Due 15 October 2008
Resolved 8 November 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 July 2008
Resolved
MAKE 03 DK A CLASS DOOR CLOSE AND LATCH.
Action required: 705 - Other - as specified
Resolved 8 December 2008
Resolution: Examined and tested door closure - all sat.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 31 July 2008
Resolved
PROVIDE APPROVAL LTR FOR SOPEP & ANNUAL AUDIT OF SOPEP.
Due 15 October 2008
Resolved 8 November 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 July 2008
Resolved
PROVE PROPER OPERATION OF HEAT DETECTION/FIRE SYSTEM FOR HEAT DETECTION OVER BOTH MDES. PROVIDE DOCUMENT FOR NEW INSTALL OF REPLACE IN KIND.
Due 15 October 2008
Resolved 22 January 2009
Resolution: CHENG ADVISED TWO DETECTORS RECEIVED AND INSTALLED - SYSTEM TESTED AND OPERATING PROPERLY.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 31 July 2008
Resolved
PROVE SHUTDOWN OF #1 SSDG WHEN FIXED FIRE SYSTEM ACTIVATED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 31 July 2008
Resolved
PROVIDE INSTRUCTIONS FOR MANUAL SHUTTING OF FIRE DAMPERS FOR ENGINE ROOM AT REMOTE HALON ACTIVATION BOX IN HALON ROOM AND OTHER LOCATIONS.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Witnessed signs posted at each activation position.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 31 July 2008
Resolved
MARK MOTOR CONTROLLER FOR HYDRAULIC GANGWAY PUMP.
Due 15 October 2008
Resolved 8 December 2008
Resolution: Witnessed motor controllers being marked.
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 September 2007
Resolved
Not working, air bound.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2007
Resolution: See narrative
Engineering › Pressure Vessel › Relief Valve
Issued 1 August 2007
Resolved
Provide proof of relief valve test on the wash water tank.
Due 15 August 2007
Resolved 15 August 2007
Resolution: RELIEF VALVE WAS REPLACED.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 August 2007
Resolved
Provide report attesting to proper operation of oily water separator prior to its use.
Due 7 September 2007
Resolved 7 December 2007
Resolution: Rcv''d report from TECO that OWS was serviced and calibrated and operating properly since Sep 8, 2007.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 1 August 2007
Resolved
Provide proof of vsl specific ballast water management plan which complies with 33CFR151.2035(a)(7)
Due 15 August 2007
Resolved 15 August 2007
Resolution: PLAN WAS PROVIDED.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 August 2007
Resolved
Provide evidence of VSP annual audits.
Due 15 August 2007
Resolved 15 August 2007
Resolution: VSP ANNUAL AUDIT WAS CONDUCTED.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 1 August 2007
Resolved
Provide records to document training & excercises specified by SOPEP sections 6 & 7 or perform required training/drills.
Due 15 August 2007
Resolved 15 August 2007
Resolution: TRAINING & EXCERCISES WERE PERFORMED.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 21 February 2007
Resolved
Engine failure on the Stbd MDE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 24 March 2007
Resolution: The casualty was caused by a J/W Pump failure. Renewed same. Engine and safety device tests were witnessed by ABS New Orleans Surveyor [name withheld]
Lifesaving › Launching Appliances › Davit
Issued 18 September 2006
Resolved
Starboard aft lifeboat davit arm damaged by allision with dock. Issued CG-835 to complete repairs to original manufacturers specifications and conduct weight test of davit to satisfaction of CG attending Inspector.
Condition: Damaged By Earlier Event
Due 19 September 2006
Resolved 19 September 2006
Resolution: Repairs completed, successful weight test conducted.
Lifesaving › Lifeboat Equipment › Whistle/Sound Signal
Issued 18 July 2006
Resolved
Provide a sound signal device for each lifebaot as per LSA Code 4.4.8.19.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Lifesaving › Lifeboat › Markings
Issued 18 July 2006
Resolved
Mark the lifeboat release handle with caution as per LSA code 4.4.7.6.2.2.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 18 July 2006
Resolved
Properly mark the hydro release with the expry date.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 July 2006
Resolved
Provide proof of VRP approval letter or proof of submittal.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 23 August 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 18 July 2006
Resolved
Service engine room fixed system, cylinder gauges appear to be inaccurate, some are over pressure and others are under pressure.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 18 July 2006
Resolved
Provide vessel with a MARPOL standard discharge connection.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 July 2006
Resolved
Service the OWS and provide proof of proper operation.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 23 August 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 July 2006
Resolved
Insure the operating controls for the fixed system are marked with the proper nomenclature.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 28 July 2006
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 29 August 2005
Resolved
Provide the vessel with a new compass deviation table due to the extensive amount of steel work that was completed in the recent yard period.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Engineering › Fuel Oil Service System › Piping
Issued 29 August 2005
Resolved
Repair the fuel oil leak in the piping in the overhead above the port reduction gear.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 29 August 2005
Resolved
Provide CG approved or SOLAS approved flashlights for the life boats.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 April 2005
Resolved
Update fire control plan as well as include the engine room in master copy.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Stability › Weathertight Integrity › General
Issued 28 April 2005
Resolved
Repair (2) weathertight doors, 02 deck passageway aft to weather deck, pilothouse aft door to weather deck, also repair (2) fire doors, main deck passageway to the mess deck, and main deck passageway to the stairway.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 April 2005
Resolved
Service the OWS and prove proper operation.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 28 April 2005
Resolved
Service fire detection system and prove proper operation.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Lifesaving › Launching Appliances › Davit
Issued 28 April 2005
Resolved
Weight test life boat falls.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 26 August 2005
Documentation › Certificates/Documents › Stability Letter
Issued 28 April 2005
Resolved
Prove the validity of the stability letter dated 27 May 1994 as the loading manuals have since been revised as of 20 AUG 1998 and 21 SEP 2000.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 23 October 2002
Resolved
In conjunction with the ABS report of 22Oct02, make proper and permenant repairs to the FWD genertaor and comply with the above mentioned ABS report. Currently FWD generator inop due to mechanical failure. LEGACY COMPONENT DESC: Crankshaft
Condition: Unknown
Due 23 November 2002
Resolved 12 November 2002
Engineering › Diesel Engine (auxiliary)
Issued 5 June 2002
Resolved
Make repairs to fwd service diesel generator prime mover and demonstrate proper operations to the satisfaction of cognizant [name withheld]: Block
Condition: Unknown
Due 5 July 2002
Resolved 23 July 2002
Lifesaving
Issued 9 May 2001
Resolved
IF MINIMALLY MANNED, PROVE PROPER OPERATION OF "DEAD MAN ALARM" ON THE BRIDGE. 46CFR 62.50-20(B).
Condition: Unknown
Due 9 June 2001
Resolved 18 May 2001
Engineering
Issued 9 May 2001
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL PRESSURE SHUTDOWN ON THE AFT GENERATOR. 46 CFR 111.12-1(C).
Condition: Unknown
Due 9 June 2001
Resolved 18 May 2001
Electrical
Issued 9 May 2001
Resolved
FIND AND REPAIR 120 V GROUND ON PANEL P-418.
Condition: Unknown
Due 23 May 2001
Resolved 18 May 2001
Fire Fighting
Issued 9 May 2001
Resolved
REPAIR HOLE IN THE FIRE MAIN AT THE DISCHARGE T DOWNSTREAM OF FIRE PUMP. 46CFR 56.97-40(A)(7).
Condition: Unknown
Due 23 May 2001
Resolved 18 May 2001
Unknown
Issued 9 May 2001
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 15 July 2001
Resolved 24 May 2001
Fire Fighting
Issued 9 May 2001
Resolved
IF MINIMALLY MANNED, REMOTE CONTROL OF REQUIRED FIRE PUMP MUST BE PROVIDED FROM THE BRIDGE. 46 CFR 62.50-20(D)(2). REQUIREMENT WAS NEVER ISSUE.
Condition: Unknown
Due 15 June 2001
Resolved 24 May 2001
Engineering
Issued 9 May 2001
Resolved
REPLACE COOLING WATER HOSE SERVICING AFT SSDG WITH APPROVED HOSE NO LATER THAN 09JUN01.
Condition: Unknown
Due 9 June 2001
Resolved 18 May 2001
Construction/Loadline
Issued 9 May 2001
Resolved
IF MINIMALLY MANNED, THE ECC MUST HAVE CONTROLS FOR INDEPENDENT BILGE PUMP AND INDEPENDENT BILGE SUCTION. 46 CFR 62.50-20(E)(2).
Condition: Unknown
Due 15 June 2001
Resolved 24 May 2001
Construction/Loadline
Issued 9 May 2001
Resolved
IF MINIMALLY MANNED, CONTROLS MUST BE PROVIDED TO OPERATE THE SEA INLET ANDDISCHARGE VALVES FROM THE ECC. 46 CFR 62.50-20(E)(4).
Condition: Unknown
Due 15 June 2001
Resolved 24 May 2001
Lifesaving
Issued 13 March 2000
Resolved
Make permanent repairs to port life boat to the satisfaction of attending marine inspector. Vessel must provide alternate survival craft while lifeboat repairs are being effected as per proposal from company dated 13 March 2000.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Engineering
Issued 11 August 1999
Resolved
Prove proper operation of low lube oil shut downs on #1 and #2 Ship ServiceDiesel Generators.
Condition: Unknown
Due 21 August 1999
Resolved 18 August 1999
Fire Fighting
Issued 11 August 1999
Resolved
Provide proof of hydorstatic test of fixed firefighting system halon bottles which are overdue.
Condition: Unknown
Due 13 August 1999
Resolved 13 August 1999
Electrical
Issued 5 November 1996
Resolved
DEMSONSTRATE PROPER OPERATION OF INSTALLED SHIP SERVICE DIESEL GENERATOR SOTHAT VESSEL HAS 2 ELECTRIC GENERATING SETS PER 46 CFR 111.10-3.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Engineering
Issued 2 October 1996
Resolved
DEMONSTRATE PROPER OPERATION OF LUBE OIL ALARMS AND SHUTDOWNS FOR BOTH SHIPSERVICE GENERATORS AND EMERGENCY GENERATOR (ELECTRICALLY AND MECHANICALLY).
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Electrical
Issued 2 October 1996
Resolved
REMOVE/PROPERLY SECURE EXPOSED ELECTRICAL CABLE IN WAY OF PORT STEERING GEAR MOTOR CONTROLLER.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Engineering
Issued 2 October 1996
Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPERATOR OIL CONTENT METER AND ASSOCIATED SHUTDOWNS AND ALARMS AS REQUIRED BY IOPP CERTIFICATE.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Electrical
Issued 28 August 1995
Resolved
Prove overspeed on aft ss generator.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 28 August 1995
Resolved
Renew grab lines on two ring buoys.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 28 August 1995
Resolved
Prove main engine lube oil alarms.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 5 August 1993
Resolved
ENSURE LIFERAFTS (SERVICE DATE CURRENTLY VALID) DTD 09-92 ARE SERVICED PRIOR TO 30SEP93. PROVIDE COPY OF SERVICING CERTIFICATE TO THE ATTENDING CGMARINE INSPECTOR.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Lifesaving
Issued 31 July 1992
Resolved
MAKE PERMENANT REPAIRS TO PORT LIFEBOAT TO SATISFACTION OF ATTENDING CG INSPECTOR AT APPROVED REPAIR FACILITY.
Condition: Unknown
Due 13 August 1992
Resolved 13 August 1992
Lifesaving
Issued 15 July 1991
Resolved
THE VESSEL IS PERMITTED TO SUBSTITUTE A 15 MAN INFLATABLE LIFERAFT WHILE THE STARBOARD LIFEBOAT IS ASHORE BEING SERVICED.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Lifesaving
Issued 14 June 1991
Resolved
MAKE PERMENENT REPAIRS TO PORT LIFEBOAT; OVERHAUL CORRODED AREAS ON HULL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Accommodation/Occupational Safety
Issued 6 November 1990
Resolved
PROVE PROPER OPERATION OF REMOTE SHUT DOWN FOR MACHINERY SPACE VENTILATION.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Lifesaving
Issued 2 June 1990
Resolved
MAKE PERMANENT REPAIRS TO STARBOARD LIFEBOAT WINCH AND HAVE STARBOARD LIFEBOAT WEIGHT TESTED IN THE PRESENCE OF A USCG MARINE INSPECTOR AS PER 46 CFR 94.35. PROVIDE ONE SUBSTITUTE 20-MAN INFLATABLE LIFERAFT ON STAR- BOARD SIDE UNTIL COMPLIANCE WITH THIS REQUIREMENT.
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Construction/Loadline
Issued 2 June 1990
Resolved
REPLACE FOUR (04) NON-METALLIC EXPANSION JOINTS IN BALLAST SYSTEM PIPING LOCATED IN NO. 5 BALLAST TANKS AS REQUIRED BY 46 CFR 61.15-12.
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Electrical
Issued 24 October 1989
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF BOTH GENERAL ALARM BELLS IN STEERING GEAR COMPARTMENT IN ACCORDANCE WITH 46 CFR 113.25-9(B).
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Engineering
Issued 24 October 1989
Resolved
PROVE OPERATION OF ENGINEERS ASSISTANCE NEEDED ALARM IN DINING ROOM IN ACCORDANCE WITH 46 CFR 113.27-1
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Engineering
Issued 24 October 1989
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF MACHINERY MONITOR SYSTEM LOSS OF ELECTRICAL SUPPLY ALARM IN ACCORDANCE WITH APPROVED TEST PROCEDURES.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Electrical
Issued 24 October 1989
Resolved
RENEW LIGHT FIXTURE AT THE 01 DECK LADDER LANDING.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Lifesaving
Issued 12 January 1989
Resolved
THE VESSEL IS PERMITTED TO SUBSTITUTE THE 20 MAN INFLATABLE RAFT FROM THE CF-1 FOR THE PORT LIFEBOAT WHILE IT IS ASHORE FOR MAINTENANCE. THE VESSEL IS PERMITTED ONE VOYAGE FROM DARROW, LOUISIANA TO TAMPA BAY, FLORIDAAND RETURN, WITH THE ABOVE SUBSTITUTE.
Condition: Unknown
Due 12 January 1989
Resolved 12 January 1989
Lifesaving
Issued 5 January 1989
Resolved
THE VESSEL IS PERMITTED TO SUBSTITUTE THE 20 MAN INFLATABLE RAFT FROM THE BARGE CF-1 FOR THE STARBOARD LIFEBOAT WHILE IT IS ASHORE FOR MAINTAINENCE. THE VESSEL IS PERMITTED ONE VOYAGE FROM BURNSIDE, LOUISIANA TO TAMPA BAY, FLORIDA AND RETURN, WITH THE ABOVE SUBSTITUTE.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Electrical
Issued 30 November 1988
Resolved
PROVE PROPER OPERATION OF EMERGENCY GERNERATOR LOW LUBE OIL ALARM IN ACCORDANCE WITH 46 CFR 112.50-3(H)(I).
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Engineering
Issued 30 November 1988
Resolved
PROVE PROPER OPERATION OF BOTH MAIN ENGINE LOW LUBE OIL PRESSURE ENGINE SHUTDOWN AND ALARM IN ACCORDANCE WITH 46 CFR 58.05-1.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Lifesaving
Issued 22 February 1988
Resolved
MAKE PERMANENT REPAIRS TO THE PORT LIFEBOAT. HOLED DUE TO WASTAGE PORT SIDE BOTTOM, IN ACCORDANCE WITH 46 USC 3313(A).
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 2 February 1988
Resolved
MAKE PERMANENT REPAIRS TO HOLE IN STARBOARD LIFEBOAT IN WAY OF STARBOARD BOW.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Engineering
Issued 16 December 1987
Resolved
REPLACE STBD MAIN ENGINE L.O. HIGH TEMP ALARM SENSER/CONTRACTOR AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Electrical
Issued 16 December 1987
Resolved
ABOARD FRTB CF1-#3 DIESEL/GENERATOR-TROUBLE-SHOOT FAULT IN SHUT-DOWN CIRCUIT AND PROVE SATISFACTOY OPERATION OF REVERSE POWER RELAY.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Electrical
Issued 29 January 1987
Resolved
PROVICE AND ISTALL SUITABLE LIMIT SWITCHES FOR EACH LIFEBOAT
Condition: Unknown
Due 29 January 1987
Resolved 29 January 1987
Lifesaving
Issued 31 December 1985
Resolved
THE VESSEL IS ALLOWED TO MAKE ONE VOYAGE FROM BURNSIDE, LA TO TAMPA, FL AND RETURN WHILE SUBSTITUTING ONE TWENTY (20) PERSON INFLATABLE LIFERAFT FROM THE CF-1 FOR THE STARBOARD LIFEBOAT. DURATION OF VOYAGE NOT TO EXCEED10 DAYS NOTIFY [name withheld] AND REINSTATION OF BOAT.
Condition: Unknown
Due 31 December 1985
Resolved 31 December 1985
Engineering
Issued 25 May 1985
Resolved
REPIPE AS ORIGINAL CIN WAY OF PVC PIPING. REDUCTION GEAR COOLING WATER LINES ON BOTH PORT AND STBD MAIN ENGINES.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Unknown
Issued 25 May 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL JAMIE A BAXTER DN583310
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
RENEW STBD TAILSHAFT # I. T. C. AB HT-15935 NOT LATER THAN 24NOV85. REPLACEMENT SHAFT TO BE EXAMINED BY A COAST GUARD MARINE INSPECTOR PRIOR TOINSTALLATION. PROVIDE TAILSHAFT READINGS TO ATTENDING CG INSPECTOR.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Unknown
Issued 25 May 1985
Resolved
REPIPE AS ORIGINAL, IN WAY OF PVC PIPING, COOLING WATER SUCTION, DISCHARGE AND ALL ASSOCIATED LINES ON (1) ONE SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985