Records from 1993 to 2026. Most recent: inspection, 14 January 2026.
Documentation record
Registered dimensions (L × B × D)61.8 ft × 26.0 ft × 8.3 ft
Registered tonnagegross 134 / net 91
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN GULF SHIPBUILDIN · LAROSE, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it134 - Regulatory (Subpart C or D), Gross Ton
91 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
14 January 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8296525
6 August 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8203703
15 December 2023
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7822171
13 October 2023
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7813438
6 February 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7632946
23 January 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6881652
20 June 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6724417
14 January 2019
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6606483
19 September 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6544235
21 May 2014
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4864727
21 May 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4874450
3 August 2011
Industry Initiated Exam · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4105820
12 June 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3504448
10 January 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3128011
15 May 2007
MTSA Verification · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2930418
11 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2927912
11 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2927998
6 May 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2937493
22 June 2006
Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2691765
23 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2609200
23 March 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2628240
18 July 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2430579
19 May 2005
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2377914
25 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2332487
5 September 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2200039
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976885
12 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1875900
26 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1475566
10 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 640779
2 July 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 189956
18 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 656848
13 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180654
31 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84480
11 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 693646
9 October 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 43351
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2020
Resolved
Witnessed crew use diesel fuel in the air starter line which created an unsafe condition. Replace starter in kind starboard MDE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 January 2020
Resolved 24 January 2020
Resolution: Replaced starter on SMDE.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 January 2020
Resolved
While conducting the general alarm test with generators running the audible alarm was barely audible on the stern of the vessel. Install bell or PA speaker within vicinity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2020
Resolved 24 January 2020
Resolution: Bell installed on stern.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 January 2020
Resolved
Inspector witnessed the port side fuel tank fuel line did not have a quick closing valve directly outside the fuel supply tank. Vessel rep to cap off the port side fuel supply line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2020
Resolved 23 January 2020
Resolution: Supply fuel line capped off.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 21 May 2014
Resolved
Vessel suffered major fire throughout entirety of vessel. Marine surveyor estimated 400k worth of damage.
Action required: 705 - Other - as specified
Resolved 14 January 2019
Resolution: Conducted thorough COI inspection 14JAN2019, vessel complies with 46 CFR Subchapter M.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 May 2007
Resolved
Fire extinguishers were expired.
Action required: 705 - Other - as specified
Resolved 15 May 2007
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 11 May 2007
Resolved
Vessel was using a portable pump to transfer fuel from tank to tank as well as transferring bilge water/oil to vessel's slop tank.
Action required: 705 - Other - as specified
Resolved 15 May 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 11 May 2007
Resolved
Excessive water leaking from both main shafts. Vessel needs to tighten rudder packing.
Action required: 705 - Other - as specified
Resolved 15 May 2007
Engineering › Steering Gear System › Rudder
Issued 11 May 2007
Resolved
Water leaking from port rudder post.
Action required: 705 - Other - as specified
Resolved 15 May 2007
Fire Fighting › Semiportable CO2 Fire Extinguishers › Pressure
Issued 22 June 2006
Resolved
BV extinguisher had little to no pressure, it had been serviced recently and appeared to have had a leak. Instructed vsl rep. to recharge/replace BV extinguisher
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 22 June 2006
Resolution: New extinguisher installed.
Communications › Alarms/Indicators › General Alarm
Issued 22 June 2006
Resolved
General alarm flashing red light and sign needed in the engine room as per 46 CFR 27.205
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 22 June 2006
Resolution: Installed as per MI''s instructions.
26 December 2001Routine · role: Involved in a Marine Casualty · activity 1475566
5 September 2004Routine · role: Involved in a Marine Casualty · activity 2200039
25 March 2005Routine · role: Involved in a Marine Casualty · at BAYOU BLUE BRIDGE · activity 2332487 19 May 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2377914
18 July 2005Routine · role: Involved in a Marine Casualty · activity 2430579
23 March 2006Routine · role: Involved in a Marine Casualty · activity 2628240
11 May 2007Routine · role: Involved in a Marine Casualty · activity 2927912
10 January 2008Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3128011
12 June 2009Routine · role: Involved in a Marine Casualty · activity 3504448
21 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4874450
20 June 2019Routine · role: Transiting Vicinity of Primary Subject · activity 6724417
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.