Records from 1999 to 2026. Most recent: inspection, 18 August 2026.
Documentation record
Registered dimensions (L × B × D)195.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 716 / net 716
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE IN, UNITED STATES · built 1999
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it716 - Simplified, Gross Ton
716 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
18 August 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8456910
3 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8213754
20 June 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7939016
28 March 2024
Damage Survey · Internal Structural Exam · Re-Inspection · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7886915
13 October 2022
Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7579906
20 July 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011215
10 December 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6871182
28 October 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6844146
6 August 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6790298
3 June 2019
Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6702554
17 July 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6482538
30 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6297732
14 March 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6104649
29 February 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5824043
21 July 2015
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5191241
16 April 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5104490
19 May 2014
Administrative Inspection · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4862199
17 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4656315
27 April 2012
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4297005
12 April 2012
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4286160
14 May 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3737998
28 May 2009
COI Inspection · Drydock Exam · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3488372
19 May 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3212637
15 May 2007
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2931264
3 April 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2900757
28 March 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2897618
7 June 2006
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2673141
28 October 2005
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2524024
6 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2350845
27 May 2004
Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2079061
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962717
23 April 2003
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1779069
16 April 2003
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1774713
26 June 2002
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1637263
9 July 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 535663
14 June 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403434
12 June 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384477
18 February 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046102
7 September 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1411960
29 June 1999
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1429176
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 July 2020
Resolved
Any Tank Vessel equipped with an internal cobustion engien driven cargo pump shall have a remote emergency shutdown that is conspicuously marked. Vessels shutdown was not clearly marked and the paint had faded. Mark the shutdown so it is clearly and conspicuously marked meeting the regulations.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 August 2020
Resolved 22 July 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 10 December 2019
Resolved
When repairs of tank vessels become necessary such work shall be under the direction of the Officer in Charge, Marine Inspection and shall be in accordance with the regulations. A hairline crack was reported in the #1 starboard cargo tank which allowed cargo to enter starboard wing tank. Vessel shall not operate until satisfactory inspection by a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 10 December 2019
Resolved
Until an inspection has been made to determine that such operation can be undertaken with safety, no alterations, repairs, or other such operations involving welding, burning, or like fire-producing actions shall be made within or on the boundaries of cargo tanks or within spaces adjacent to such cargo tanks. Vessel shall not conduct repair or hot-work until satisfactory approval by a Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 October 2019
Resolved
Vessel must have approved Vessel Security Plan. Vessel must provide approved VSP prior to cargo operations
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2019
Resolution: 29OCT2019: Vessel representative provided MSC approval letter for VSP. MISLE activity closed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2014
Resolved
High level alarm system electrical wiring no longer "intrinsically" safe
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2014
Resolution: Verified electrician made repairs to make system intrinsically safe.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 19 May 2014
Resolved
Cargo tank P/V Valves have open plug in side
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2014
Resolution: Verified PV valves have been plugged.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 12 April 2012
Resolved
Properly demonstrate the High Level/Overfill alarms in the presence of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 12 April 2012
Resolution: The #1 High Level and Overfill alarms were backwards. Repair facility swapped alarm leads and re-tested with sat results.
Deck/Cargo › Vapor Control Systems
Issued 16 April 2003
Resolved
Prior to cargo operations, test installed overfill protection devices to the satisfaction of an attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Liquid Overfill Protection
Action required: 705 - Other - as specified
Resolved 23 April 2003
Resolution: Tested Overfill protection / alarm system as sat. Cleared outstanding CG 835.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 26 June 2002
Resolved
Threaded portion of cargo block valve closure indicator was not secured to the reachrod. In this condition, the indicator is inoperative.
Condition: Improper/Lack of Maintenance
Due 26 June 2002
Resolved 26 June 2002
Resolution: Set screws securing threaded portion of valve closure indicator to the cargo valve reachrod tightened.
Deck/Cargo
Issued 7 September 1999
Resolved
PROCEED DIRECTLY TO BATON ROUGE, LA TO OFFLOAD CSB AT A FACILITY CERTIFIEDTO HANDLE BENZENE PRODUCTS. CONTACT COGNIZANT [name withheld] OF CARGO. VSL MUST COMPLY WITH 46 CFR 197 DURING TRANSIT AND BARGE MUST BE CLEANED OF RESIDUAL BENZENE PRODUCTS PRIOR TO LOADING CARGO.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Deck/Cargo
Issued 29 June 1999
Resolved
OPERATION OF THE VAPOR RECOVERY SYSTEM IS PROHIBITED UNTIL THE SYSTEM HAS_x001C_ BEEN APPROVED AS INSTALLED. THE APPROVAL LISTED ON THE TEMPORARY COI IS_x001C_ INVALID BECAUSE THE SYSTEM WAS NOT INSTALLED IN ACCORDANCE WITH THE MARINE_x001C_SAFETY CENTER LETTER SERIAL #C2-9601841 DATED JUNE 18, 1996.
Condition: Unknown
Due 24 September 1999
Resolved 23 September 1999