Records from 1999 to 2026. Most recent: inspection, 6 July 2026.
Inspection history · 149
6 July 2026
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8426057
5 January 2026
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8289869
7 July 2025
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8177869
6 January 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8050471
8 July 2024
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7952058
22 January 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851511
17 August 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7770681
24 July 2023
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7748147
16 July 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7743566
28 January 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627275
23 January 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7625527
25 September 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7567295
8 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7527700
30 July 2022
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7519027
9 June 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7472954
3 February 2022
PSC B · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7390116
6 August 2021
Administrative Inspection · PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7274927
20 December 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7114337
3 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935067
3 February 2020
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901373
26 October 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6842521
20 October 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6837966
17 October 2019
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6836434
13 October 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6834815
7 October 2019
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6829640
24 September 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6821465
28 April 2019
ISPS II Exam · COC-CVE Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6671742
29 November 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6587003
28 October 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6635007
14 August 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6515000
26 June 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6456734
4 June 2018
COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6431982
18 May 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6438014
3 May 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404938
19 April 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6394847
18 April 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6394076
12 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6391054
13 January 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337523
11 January 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6335978
14 December 2017
Deficiency Check · ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6320047
3 December 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6316701
3 December 2017
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6316742
30 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6315393
31 October 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6301629
19 October 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6290761
11 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6285632
13 July 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6207535
10 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6171348
5 June 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6164814
15 December 2016
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6056183
3 August 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5973220
11 June 2016
COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903595
16 April 2016
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5855450
7 March 2016
ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5825685
18 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5817985
10 December 2015
ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5776085
12 November 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5769098
15 October 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5769076
12 September 2015
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5231555
20 October 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5009000
6 October 2014
Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4997520
21 August 2014
Deficiency Check · Spot Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4961146
21 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4961875
7 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4947543
12 June 2014
Ballast Water Examination · Deficiency Check · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4880236
29 May 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4929240
10 May 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4929206
17 May 2012
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4296892
19 December 2011
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4205342
28 January 2011
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3934857
20 December 2010
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912484
18 November 2010
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3900219
14 March 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4146689
25 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3790942
4 January 2010
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex VI Survey · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3657476
27 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3570488
4 January 2009
MARPOL Annex I Examination · COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3387098
20 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3356662
19 September 2008
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3328213
6 July 2008
COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3255592
15 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3241623
3 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3197796
25 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3204578
20 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3187970
22 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3169314
5 January 2008
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124630
15 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3116163
8 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3111827
17 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3100038
18 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2999153
7 July 2007
MARPOL Annex I Examination · Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2991452
4 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2982929
26 May 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2940823
17 February 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2878280
1 July 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2696920
2 February 2006
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2578163
23 October 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2520188
18 October 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2516707
7 July 2005
MARPOL Annex V Examination · COC-CVE Annual · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2418001
2 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2537140
17 June 2005
Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2393420
10 June 2005
ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2386455
4 June 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2378765
28 February 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2301119
27 January 2005
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2282010
14 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2165779
10 July 2004
Random ISPS/MTSA/PSC · COC-CVE Annual · MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2127902
3 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2119629
12 June 2004
MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2095854
24 January 2004
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1991599
1 January 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1972575
1 October 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1918573
26 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1913529
13 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1911962
2 August 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1865210
26 July 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1857546
18 July 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1850238
28 June 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1829089
12 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1772480
12 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1772483
8 February 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1741757
18 January 2003
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1732197
6 October 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1685527
14 September 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1675464
9 September 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1672778
22 August 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1664882
22 August 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1664907
22 August 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1664910
15 August 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1661747
18 July 2002
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1649028
17 May 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1617989
2 February 2002
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1483309
21 July 2001
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397684
21 April 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1362145
20 January 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361912
18 January 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 91502
14 October 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 822146
6 September 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 89603
22 July 2000
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1051831
17 June 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278946
22 April 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 817262
8 March 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1046398
22 January 2000
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372896
23 October 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361169
24 July 1999
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1395229
11 July 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096210
10 July 1999
Type not recorded
No type recorded · Activities Europe · Activity 1361016
18 June 1999
Type not recorded
No type recorded · Activities Europe · Activity 1391046
8 June 1999
Type not recorded
No type recorded · Activities Europe · Activity 1360924
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 January 2025
Resolved
Any required automatic sprinkler, fire detection and fire alarm system be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. PSCO observed high pressure water-mist Sprinkler outside of FSD 11.028 to be without fluid in the bulb.
74 SOLAS 01 II-2/12.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 January 2025
Resolution: Replaced bulb with new
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 22 January 2024
Resolved
The provisions on the prevention of accidents and protection of health in employment which may be applicable to the work of seafarers, and shall specify measurers for the prevention of accidents which are peculiar to maritime employment. PSCOs observed an overflow of luggage carts which were causing an excess of garbage leading into the garbage room. Some of these garbage bags were broken causing spillage and a large mix of hazardous and non-hazardous waste.
ILO-147/PWSA 33 USC 1223(b)1 Accident Prevention/2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2024
Resolution: Cleared on the spot
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 January 2024
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCOs observed stored items which was blocking a corridor exit on Deck 3 MVZ 6.
74 SOLAS 97 II-2/28.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2024
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 January 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCOs observed 02 Fire Screen Doors (FSD) that did not properly close and latch, being FSD A081 and FSD A080.
74 SOLAS 97 II-2/30.4.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2024
Resolution: Cleared on the spot. Door closure was adjusted to properly shut during higher ventilation pressure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 January 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCOs observed 02 Fire Screen Doors (FSD) that would not close and latch, being FSD 0001 Paint locker and FSD 0042 Photo room.
74 SOLAS 97 II-2/30.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2024
Resolution: Door pressure adjusted to properly close and latch. Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 January 2024
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCOs observed a low location photoluminescent strip approximately 0.5 m in length missing in MVZ 3 near F.S.D. 0.083.
74 SOLAS 01 II-2/41-2.4.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2024
Resolution: Cleared on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 22 January 2024
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. A ship's crew member on deck 9, starboard side, who is a part of the sea food staff did not know use of the ship's fire-extinguishing appliances.
74 SOLAS 20 II-2/15.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2024
Resolution: Training conducted and cleared on the spot.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 January 2024
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. The ship's crew members on the quick response team who were the first to enter the space where the fire drill was being conducted did so without being on air. 1) their bottle was empty under entry, and 2) the other did not have their regulator correctly attached.
74 SOLAS 20 II-2/15.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2024
Resolution: Training conducted and corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported casualty to main engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2022
Resolved
Vessel failed to meet NOA time requirements.
Action required: 15 - Rectify deficiencies by next port
Due 10 July 2022
Resolved 24 June 2022
Resolution: Vessel provided updated NOA and was issued an LOW.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 April 2019
Resolved
Where the emergency source of electrical power is a generator, it should be started automatically upon failure of the electrical supply from the main souorce of elctrical power. Emergency Diesel generator charger unit for start batteries is out of service and temporary portable battery charger installed and approved by Flag/RO as temp reapir with engineers conducting rounds every 8hrs iuntil permanent repair completed. SOLAS 74 (2004 cons)CH II-1 Reg 42.3.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: Received Lloyds class report No. 2035411 Rev 1 attesting satisfactory repair and replacement of the RPD card for the EDG emrengcy starting batteries.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 April 2019
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the electrical supply from the main source of electrical power. PSCO observed Emergency Generator fail to automatically start during simulated failure of main source of electrical power. SOLAS 74 (2005 cons) CH II-I Reg 42.3.1.1.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 29 April 2019
Resolution: Def resolved and replaced by Def #10 (issued 29APR19) with Flag/RO approved temp repair and conditions. Permanent repair to be completed in 30 days.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 April 2019
Resolved
The minumum fire intergrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed A-0 boundry/weather deck window in way of atrium was broken. SOLAS 74 (1997 cons) CH II-2 Reg. 26.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2019
Resolved 10 June 2019
Resolution: Received Llyods Class report attesting to satisfatory installation of approved A-0 glass. Llyods report# 2037310.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 April 2019
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed life raft davit #3 parted an electrical wire while deploying life raft. SOLAS 74 (1997 cons) CH III Reg. 19.2.
Action required: 10 - Deficiency Rectified
Due 28 April 2019
Resolved 28 April 2019
Resolution: SHip electrician repaired electrical cable and demonstrated satisfactory operation to the PSCO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 April 2019
Resolved
Illustrations and instructions shall be posted in passenger cabins and be conspicously displayed at muster stations and other passenger spaces to inform passengers of thier muster station. PSCO observed camp ocean, spa, pizzaria, radiance resuraunt, stage (all exits port/stbd), comedy club, arcade, and all spaces that were recently modified lacked adequate signage. (This list is NOT all inclusive) SOLAS 74 (2004 cons) CH III Reg. 8.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2019
Resolved 29 April 2019
Resolution: Ships crew installed new signage to the satisfaction of Flag/RO.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 April 2019
Resolved
COntrol handles shall be provided at each side of the bulkhead, THe direction of movement of the handles in opening and closing of the door shall be in the direction of door movement and shall be clearly indicated. PSCO did not observe instructions on watertight door located in Deck zero-MVZ 1. SOLAS 74 (2014 cons) CH II-1 Reg 13.7.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 29 April 2019
Resolution: Ship installed proper door operating instructions to satisfaction of Flag/RO.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2019
Resolved
IN addition to complying with the specific provisions for fire intergrity of bulkheads and decks, the minimum fire integrity of all bulkheads adn decks shall be as described in table 26.1 to 26.4. AC station 6.1.15 is being used as an office space. SOLAS 74 (1997 cons) CH II-2 Reg. 26
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 29 April 2019
Resolution: Office equipment removed from AC space to satisfacion of Flag/RO.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 April 2019
Resolved
Except for hatches between cargo, special category store adn baggage spaces and between such spaces adn weather decks. Openings shall be at least as effective for resisiting fire as the divisions in which they are fitted. PSCO observed the rolling shutters in the pizzareia and crab and lobster resuraunt did not completely close. SOLAS 74 (2014 cons) CH II-2 Reg. 4.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 29 April 2019
Resolution: Completed to satisfaction of Flag/RO and witnessed by CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 April 2019
Resolved
The construction of doors in "A" class divisions shall provide resistance to fire as well as to the passing of smoke and flame equivalent to that of the bulkhead in which the doors as situated. PSCO observed fire screen doors in spa, comedy cllub, stage area, showroom, dressing room, deck 4 going to lifeboat deck port & STBD were missing the door handle mechanism hardware. SOLAS 74 (1997 cons) CH II-2 Reg 9.4.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 29 April 2019
Resolution: Door handle mechanism installed to satisfaction of Flag/RO and witnessed by CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 April 2019
Resolved
All doors shall be capable of automatic release from a position at both sides of the door. PSCO observed FSD 3008 switch to be broken. SOLAS 74 (1997 cons) CH II-2 Reg. 30.4.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 29 April 2019
Resolution: FSD 3008 switch repaired to satisfaction of FLag/RO and witnessed by CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2018
Resolved
07105-(Fire doors/openings in fire-resisting divisions)The following Fire Protection Systems shall be kept in good working order so as to ensure their required performance if a fire occurs, PSCO noticed Fire Screen Door 05-045 (Game Room Escape) not working as designed.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 29 November 2018
Resolved 29 November 2018
Resolution: Corrected on the spot.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 4 June 2018
Resolved
0899- Other - Portions of the handrails in the port and starboard steering gear room were missing.
-74 SOLAS (2004 CONS) II-1/29.13.2
10c
Action required: 10 - Deficiency Rectified
Due 5 June 2018
Resolved 5 June 2018
Resolution: Vessel made repairs in presence of PSCO
Engineering › Steering Gear System › Power Unit
Issued 4 June 2018
Resolved
9800 - other - Port adn starboard steergin gear room motor control lights were nonoperational.
-74 SOLAS (2004 CONS) II-1/30.1
-10c
Action required: 10 - Deficiency Rectified
Due 5 June 2018
Resolved 5 June 2018
Resolution: repairs were made prior to PSCO departing
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 June 2018
Resolved
0799 - other - PSCO found several sliding air actuated fire screen doors that continued 2 feet after being contacted by an object and retracted to the full open position (past 1 meter).
-74 SOLAS (1997 CONS) II-2/30.4.
-16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 July 2018
Resolution: Recieved class report from LR attesting to the repairs.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 4 June 2018
Resolved
1581 - Rudder angle indicator - When helmsman calls for 35 degrees port or starboard, the rudder stock goesto 38 degrees and the rudder angle indicator on the bridge shows 40 degrees.
-74 SOLAS (2004 CONS) II-1/29.3.2
-16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 26 June 2018
Resolution: PSC NOLA RECIEVED A CLASS REPORT SATISFYING THE REQUIREMENT.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 4 June 2018
Resolved
1720 - Control of oil - vessel's engineering crew could not provide documentation of hydrostatic pressure test of bunker lines.
33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Due 5 June 2018
Resolved 8 June 2018
Resolution: Receive, received and accepted documentation from the master stating the hydro test had been conducted at 1.5 MAWP
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 3 May 2018
Resolved
1410- Propulsion Main engine - The condition of the ship shall be maintained fit to proceed to sea without danger to the ship or persons on board. Vessel reported a reduction in propulsion power due to possible malfunction of the fuel delivery system. Vessel is only capable of achieving 55% output with 5 generators on line. Prior to departure provide technician report attesting that the 6 generator is operating as designed and tested under load. In addition, provide documentation from technician of the likelihood of continued degradation of the fuel system
components on remaining generators to take place during the
voyage .74 SOLAS 2014cons I/ll 17 a,c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2018
Resolved 3 May 2018
Resolution: Received report from LR clearing this deficiency. (see narrative)
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 3 December 2017
Resolved
1499-Conditions of ship shall be maintained to proceed to sea without danger to the ship or persons onboard. Vessel's port manin engine shaft CCP system has been altered to maintain fixed position of propellor blades as a terporary repair until next drydock May 2018. Class to survey temporary repair testing under full load while in transit from Mobile Bay Sea Buoy to SouthWest Head of Passes LA. Request Sector NOLA clear this deficiency upon satisfactory test results and issuance of interim certificate with the condition of class.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 14 December 2017
Resolved 14 December 2017
Resolution: Received attestation from Class Society to satisfactory ahead operation of #2 CPP, & limited astern operation. Condition of Class imposed to expire March 2018 for CPP to be dealt with by drydock in May 2018.
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 19 October 2017
Resolved
01-1720-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL HAS AN HFO FUEL LEAK COMPROMISING THE BALLAST SYSTEM.-74SOLAS (01 CONS) I/11. 50AC
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 19 October 2017
Resolution: Received class report for the corrective actions taken by the vessel to further prevent the HFO contaiminated ballast tanks from contaiminating the rest of the ballast system. Refer to LR class report dated 19OCT2017 in documents Act #6290761
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Discharge Outlets
Issued 13 July 2017
Resolved
0725-Fixed Fire Ext Installation-Passenger ships carrying >36 passengers shall be equipped with an automatic sprinkler system. Vessel reported 50% failed nozzles in 10 of 62 sections, & is conducting total replacement of sprinkler nozzles. PSCOs examined sat testing of sections #60 & #61 IAW basic testing requirements of MSC.1/Circ.1516. Deficiency to be met at expiration of PSSC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 11 October 2017
Resolution: Received class report fixing the automatic sprinkler.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 June 2017
Resolved
0745-Fire Dampers-When a ventilation duct passes through a MVZ, a fail-safe automatic closing fire damper shall be fitted adjacent to the division. PSCO observed that the FO purifier room and fwd auxiliary machinery room fire dampers local panel showed open,closed and fault locally when the fire damper was open. 74SOLAS(01) II-2/32.1.1 16a
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Fire Fighting › Ventilation Systems › Ducts
Issued 5 June 2017
Resolved
9900-Other Haz- The duct between the divison and the damper shall be of steel or other equivalent material and if necessary, insulated to comply w/ the requirements of reg 18.1.1. PSCO observed that the ventilation supply duct from the machinery space to the laundry room has a large hole in it. 74SOLAS(01) II-2/32.1.1 16a
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 June 2016
Resolved
1270 - Doors - The doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degree closure, and shall have an approximate uniform rate of closure of not more than 40 secs and no less that 10 secs with the ship in the upright position PSCO observed 50+ fire screen doors with closure time less than 10 seconds. SOLAS(97)II-2/30.4.1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 June 2016
Resolved 16 June 2016
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. PSCO re-checked doors on 16JUN2016 and determined that 45 of 51 doors were corrected. Remaining doors will be tested at PSSC survey in July 2016.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 11 June 2016
Resolved
2110-Oil/oily mixtures machinery spaces-The condition of the ship and its equipment shall be maintained with the provisions of the present regulations to ensure that the ship respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed starboard side CPP w/ substantial internal leak.Oil was collected, purified, & returnd to power pack.SOLAS I/11. 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 June 2016
Resolved 16 June 2016
Resolution: A class report from [name withheld] stating that the oil leak on the oil distribution box was inspected by the manufacturer's technician and considered the leak to not have any negative effect to operation, oil pollution, or safety to the vessel.
Fire Fighting › Fire Hoses › Condition
Issued 11 June 2016
Resolved
0720-Fire fighting equipment-Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed that the door latch for fire station #33 was inoperable and the fire station was inaccessible for immediate use. SOLAS(97)II-2/21 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 11 June 2016
Resolution: Vessels crew was able to unblock the fire station prior to the end of the exam.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 March 2016
Resolved
Double leaf doors equiped with a latch nesessary to thier fire integrity shall have a latch that is automatically activated by the opperation of the doors when released by the system. fire screen foors: 4.025, 4.040, 4.038, and 4.029 do not function as designed. 74SOLAS(97)CH 11-2 reg 30.4.5
Condition: Improper Installation
Due 6 April 2016
Resolved 16 April 2016
Resolution: PSC NOLA received Passenger Ship Safety Certificate from LR satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 March 2016
Resolved
The doors shall be self-closing and be capable of clossing with an approxmately uniform rate of closure of no more than 40s and no less than 10s with the ship in upright position. Fire screen doors: 2.019, 2.020, 2.030, 3.067 and 4.017 close too fast. 74 SOLAS (97) CH II-2 Reg 30.4.1
Condition: Improper Installation
Due 6 April 2016
Resolved 16 April 2016
Resolution: PSC NOLA received Passenger Ship Safety Certificate from LR satisfying the requirement.
Electrical › Electric Generation Source (emergency) › Generator
Issued 18 February 2016
Resolved
0950 - Electric Equipment in General - Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the electrical supply from the main power source of electrical power. The EDG does not start due to a power failure from the main bus due to a malfunctioning component. - 74 SOLAS (97) II-1/42.3.1.2 - 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 February 2016
Resolved 22 February 2016
Resolution: witnessed satisfactory operation of EDG.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 December 2015
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including protection of openings and penetrations in these divisions. Remote-released sliding door 5.025 does not reopen a satisfactory distance to permit the passage of a person contacted by the door during closing, a minimum of .75 meters.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2015
Resolved 14 December 2015
Resolution: Door repaired to the satisfaction of attending Class Surveyor and USCG Examiner.
Lifesaving › Inflatable Liferafts › Float Free
Issued 21 August 2014
Resolved
0628-On passenger ships every liferaft shall be float free and if inflatable, inflates automatically when the ship sinks. PSCO observed inflatable liferaft under catwalk on port and starboard side on deck 4 appear to not be float free. 74SOLAS(97) III/23-16.a.c.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 21 August 2014
Resolution: Recieved satisfactory class report attesting to proper working design and re-marking of liferaft installation. See report in "document section"
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 June 2014
Resolved
Vessel's #2 sewage tranfer pump was found to have a leaking seal resulting in standing sewage water. Make proper repair to mechanical seal within 14 days (33 CFR 159)
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 16 June 2014
Resolution: Vsl replaced mechanical seal. No leak observed. Def cleared.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 June 2014
Resolved
Vessel's #4 sewage treatment plant piping elbow was found to have a pinhole leak. Make proper repair to piping within 14 days. (33 CFR 159)
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 16 June 2014
Resolution: Vsl replaced piping elbow. No leak observed. Def cleared.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 July 2007
Resolved
Bilge Pumps were tested and the sump level was raised to alarm height, however the pump could not create suction to lower the level to resume normal condition.
Action required: 705 - Other - as specified
Due 14 July 2007
Resolved 21 July 2007
Resolution: Def cleared. Class issued certificate # MMI-700230 attesting that bilge system thoroughly examined and found all bilge pumps working effectively.
//s// [name withheld] J Suffern
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 27 January 2005
Resolved
Rome lounge contains multiple and excessive power strips for band equipment, make permanant and separate means for equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 March 2005
Resolution: Excess power strip removed, strip were separated and permanent.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 27 January 2005
Resolved
Test fire screen doors to the satisfation of U.S. Coast Guard Marine Inspector. Fire Screen doors # 5-051, 3-038, 4-057, 5-048, 50-24, 4-046.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 March 2005
Resolution: Witnessed operational test of all listed doors.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 January 2005
Resolved
Rome loundge orchestra lift pit, contains hydrolic leaks and excessive garbage debris understage. Clean Hydrolic oil from under stage and repair hydrolic leaks.
Condition: Improper/Lack of Maintenance
Due 28 February 2005
Resolved 28 March 2005
Resolution: Vessel received 2 new rams and were in the process of install them. All debris and oil were removed/clean from deck.
Construction/Loadline › Structures › Door
Issued 27 January 2005
Resolved
Identify purpose of space in Rome Lounge near stage. Ensure it meets category requirements.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 March 2005
Resolution: The storage bins were removed and room was cleaned.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 January 2005
Resolved
Identify material composite of Rome Lounge stage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 March 2005
Fire Fighting › Means of Escape
Issued 18 January 2003
Resolved
Have Flag State address dead-ended corridor on deck 1 fwd- access to chain locker and bos'n stores IWO FSD 1,001 IAW 74 SOLAS II-2/28.4. LEGACY COMPONENT DESC: Corridors
Condition: Unknown
Due 3 February 2003
Resolved 8 February 2003
Resolution: 8FEB03 [name withheld] boarded vsl to verifiy dead end corridor egress issue had been corrected; deck 1 fwd. Lloyds Register surveyor [name withheld] concluded that suitable notices are to be posted to door in question, marked for crew access and locked.
Fire Fighting
Issued 21 July 2001
Resolved
Have class address the spacing of heat detectors in the galley areas, IAW SOLAS II-2/13.2.5 & Solas II-2/41-2.2.
Condition: Unknown
Due 21 July 2001
Resolved 1 August 2001
Construction/Loadline
Issued 20 January 2001
Resolved
Make permanent and proper repairs to the satisfaction of Class to the crackin the #7 starboard void space. Temporary repairs have been made and Condition of Class has been issued. All reports in vessel file.
Condition: Unknown
Due 31 July 2002
Resolved 15 August 2002
Resolution: LR Class report recieved showing condition of class now imposed on vessel to make permanent repairs upon arrival dry dock this October.
Engineering
Issued 23 October 1999
Resolved
Perform satisfactory test of OWS in presence of USCG Marine Inspector, prior to use of the OWS.
Condition: Unknown
Due 23 October 1999
Resolved 10 November 1999
Engineering
Issued 23 October 1999
Resolved
Have Class. address adequecy and performing standard of 15PPM OWS without the use of the additional WT1-1206 Filtering System, IAW MARPOL 73/78 Reg I/16, prior to use of the OWS.
Condition: Unknown
Due 23 October 1999
Resolved 10 November 1999
Engineering
Issued 23 October 1999
Resolved
Retain all oily waste on board and discharge only to an approved shoreside facility, IAW 33 CFR 155, prior to the use of the OWS.
Condition: Unknown
Due 23 October 1999
Resolved 10 November 1999