MAURY USCG vessel records Sign in
← All vessels

ENSCO 74

ENSCO 74 is a 1999 mobile offshore drilling unit. The Coast Guard has recorded 35 inspections since 1999, most recently in March 2009, along with 27 deficiencies — 2 with no resolution recorded —.

Records from 1999 to 2009. Most recent: inspection, 6 March 2009.

Built
1999
Last inspected
6 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8764420 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP 9601
496099
Flag
PANAMA
—
Maury page id
psix-496099

Inspections, by type

…with no type recorded21
…past their stated due date2
Years with a record 11 calendar years (1999–2009)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it7157 - Regulatory (Subpart C or D), Gross Ton
2147 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SKS SATILLA Tank Ship · MISLE 860710 · 6 March 2009 · activity 3428886ML GROVE Offshore Supply Vessel · MISLE 455468 · 19 November 2003 · activity 1950921

Inspection history · 35

6 March 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3428886
13 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3235697
9 June 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3231863
20 May 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3212140
29 September 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3068911
22 May 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2937172
12 June 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2677531
16 June 2005 COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392376
21 April 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2348074
10 March 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2307280
25 February 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2307213
16 November 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246312
30 June 2004 COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2117013
21 January 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2004858
19 November 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1950921
3 November 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1940890
3 November 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1941267
18 June 2003 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1819872
8 April 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1770306
15 January 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731054
17 November 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731047
13 September 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731002
18 August 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1707481
16 August 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1707440
11 August 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1694038
14 July 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1707397
8 July 2002 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1641372
26 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 184212
21 June 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376688
29 June 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1369785
15 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 788036
6 June 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 806253
3 June 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1418542
25 May 1999 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 752019
18 May 1999 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 211044

Deficiency record · 27

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 June 2008 No resolution recorded
Ensure door between Galley and Pantry meets requirements of approved fire control plan.
Action required: 705 - Other - as specified
Due 12 July 2008 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 June 2008 No resolution recorded
Service latches on all fire doors to ensure proper operation.
Action required: 705 - Other - as specified
Due 12 July 2008 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions
Issued 18 June 2002 Resolved
Properly install A-60 structrual fire protection (SFP) in way of radio room and physical fitness room to include complete weld of A-0 bulkhead, and insulation where windows previously were located. LEGACY COMPONENT DESC: Bulkheads - Control Stations
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 8 July 2002
Resolution: A-60 SFP was installed betwen the radio room and fitness room, the A-0 bulkhead completely welded, and insulation installed were window had previously been. The OIM forwarded digital pictures of the corrections, as well as verified on board by ABS.
Fire Fighting › Fixed Fire Detection System
Issued 18 June 2002 Resolved
Properly mount smoke detector in room 204. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 8 July 2002
Resolution: The smoke detector was re-installed in the overhead of the crews room 204. Repair verified on board by ABS surveyor.
Construction/Loadline
Issued 21 June 2001 Resolved
Prove vessel's bilge pumping system. Unable to take suction this date. Prove suction with all 4 pumps.
Condition: Unknown
Due 19 July 2001
Resolved 10 August 2001
Lifesaving
Issued 21 June 2001 Resolved
Provide proof of weight test at fall renewal and 1.1 on releasing gear.
Condition: Unknown
Due 19 July 2001
Resolved 10 August 2001
Lifesaving
Issued 21 June 2001 Resolved
Repair releasing cable pulley for #1 lifeboat.
Condition: Unknown
Due 22 June 2001
Resolved 10 August 2001
Documentation
Issued 21 June 2001 Resolved
Provide documentation and logs to prove compliance with the requirements of46 CFR 109.213 and 89 code 14.11 and .13.
Condition: Unknown
Due 30 September 2001
Resolved 20 May 2003
Fire Fighting
Issued 29 June 2000 Resolved
REPAIR ELECTRICAL FIRE DAMPNER SYSTEM IN WAY OF 1ST DECK PASSAGEWAY.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
PROPERLY SUPPORT ARMOR SHEATHED ELECTRICAL CABLE FOR GAS DETECTOR ON STARBOARD SIDE OUTBOARD SHAKER UNIT.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
REMOVE PORTABLE ELECTRICAL FAN FROM MUD PIT ROOM, REPAIR OR REPLACE LOOSE /EXPOSED ELECTRICAL WIRING CONNECTION.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
REPLACE OR REPAIR BROKEN LIGHT FIXTURE COVERS IN WAY OF MAIN DECK CATWALK, PORT SIDE MAIN DECK ENTRANCE TO MACHINERY SPACES AND STARBOARD SIDE ENTRANCE TO DRILL FLOOR AREA.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Navigation
Issued 29 June 2000 Resolved
PROVIDE ON BOARD 2ND RADIO TELEPHONE GENERAL OPERATOR WITH VALID CERTIFICATION.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Documentation
Issued 29 June 2000 Resolved
PROVIDE ONBOARD ORIGINAL LICENSES / CERTIFICATES FOR LICENSES / DOCUMENTED PERSONNEL.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Documentation
Issued 29 June 2000 Resolved
PROVIDE ONBOARD APPROVED EMERGENCY EVACUATION PLAN.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Documentation
Issued 29 June 2000 Resolved
PROVIDE COGNIZANT OCMI WITH COPY OF VALID MODU CODE, LOADLINE, IOPP AND SAFETY RADIO CERTIFICATES.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Construction/Loadline
Issued 29 June 2000 Resolved
REWORK, REALIGN AND PROVE PROPER SEAL OF AFT MAIN HOUSE STARBOARD SIDE WTD TO MACHINERY SPACES.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Fire Fighting
Issued 29 June 2000 Resolved
SERVICE AND SEAL CO2 PORTABLE FIRE EXTINGUISHER ON PORTSIDE OF DRILLER'S FLOOR.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Unknown
Issued 29 June 2000 Resolved
SECURE ALL OUTER CONTINENTAL SHELF ACTIVITIES & OPERATIONS. SUBMIT TO U.S.COAST GUARD INSPECTION AND OBTAIN VALID LETTER OF COMPLIANCE PRIOR TO RESUMING ACTIVITIES.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
PROVE PROPER OPERATION OF LOW LUBRICATION OIL SHUTDOWNS ON NO.1,2,&4 SHIP SERVICE GENERATORS.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
PROVE PROPER OPERATION OF NO 1 THRU 4 SHIP SERVICE GENERATORS REVERSE POWERRELAYS.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Electrical
Issued 29 June 2000 Resolved
CLEAR GROUND AND PROPERLY LABEL 120/208V LIGHTING PANEL IN SCR ROOM.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Construction/Loadline
Issued 29 June 2000 Resolved
ADJUST STARBOARD SIDE WATER TIGHT DOOR TO ENGINE ROOM.
Condition: Unknown
Due 3 August 2000
Resolved 10 August 2000
Fire Fighting
Issued 3 June 1999 Resolved
COMPLETE INSTALLATION OF REQUIRED HELO DECK FIRE FIGHTING FOAM SYSTEM AS REQUIRED BY 89 IMO MODU CODE REF 9.11.2.2 OF CODE. SUBMIT TO USCG MSSO BROWNSVILLE, TX ABS REPORT OF ACCEPTANCE AND TESTING.
Condition: Unknown
Due 3 July 1999
Resolved 20 May 2003
Lifesaving
Issued 3 June 1999 Resolved
PROVIDE FLAG STATE ACCEPTANCE TO USCG MSSO BROWNSVILLE, TX FOR THE EXCLUSION OF IMMERSION SUITS WHILE UNIT OPERATES IN WARM WATERS AS ALLOWED BY 89 IMO MODU CODE 10.11.1
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Unknown
Issued 3 June 1999 Resolved
COMPLETE REVIEW AND TESTING OF ONBOARD CRANE'S BY ABS TO CERTIFY COMPLIANCEWITH THE 89 IMO MODU CODE 12.1.8 (WARNING ALARMS AND OVERLOADING OF INSTALLED CRANES). SUBMIT TO USCG MSSO BROWNSVILLE, TX ABS ACCEPTANCE.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Documentation
Issued 3 June 1999 Resolved
PROVIDE DOCUMENTATION TO USCG MSSO BROWNSVILLE, TX THAT ABS HAS COMPLETED REVIEW OF UNITS CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.